Object: To determine whether moderate bone loss in revision total knee arthroplasty can be corrected using an
Aim: To determine whether moderate bone loss in revision total knee arthroplasty can be corrected using an
Infection after total hip arthroplasty is a severe complication. Controversies still exist as to the use of cemented or uncemented implants in the revision of infected THAs. Based on the data in the Norwegian Arthroplasty Register (NAR) we have studied this topic. During the period 2002–2008 45.724 primary THAs were reported to NAR. Out of these 459 were revised due to infection (1,0%). The survival of the revisions with uncemented prostheses were compared to revisions with cemented prostheses with antibiotic loaded cement and to cemented prostheses with plain cement. Only prostheses with the same fixation both in acetabulum and in femur were included in the study. Cox-estimated survival and relative revision risks were calculated with adjustments for differences among groups in gender, type of surgical procedure, type of prosthesis, and age at revision.Introduction
Material and Methods
The aim of this study was to develop a single-layer hybrid organic-inorganic sol-gel coating that is capable of a controlled antibiotic release for cementless hydroxyapatite (HA)-coated titanium orthopaedic prostheses. Coatings containing gentamicin at a concentration of 1.25% weight/volume (wt/vol), similar to that found in commercially available antibiotic-loaded bone cement, were prepared and tested in the laboratory for: kinetics of antibiotic release; activity against planktonic and biofilm bacterial cultures; biocompatibility with cultured mammalian cells; and physical bonding to the material (n = 3 in all tests). The sol-gel coatings and controls were then tested in vivo in a small animal healing model (four materials tested; n = 6 per material), and applied to the surface of commercially pure HA-coated titanium rods.Aims
Methods
Total hip arthroplasty (THA) is the only successful treatment for patients in whom the hip joint is destroyed by inflammatory arthritis. Due to the effects of both the disease and its treatment elevated rates of complications and of aseptic loosening have been described. Whether with modern uncemented hip prostheses the results can be improved is not fully known. Therefore, we decided to carry out a prospective study.
At the introduction of a new press-fit acetabular component a prospective study on the results of uncemented THA was started. From 1995 to 1999 85 primary THAs were carried out in 72 patients (57 women, 15 men) suffering from inflammatory arthritis. Diagnosis: RA 76, adult-onset Still 4, JIA 3, miscellaneous 2. Mean age at operation was 60 years (SD 15. 9). Clinically, the Harris Hip Score was used for evaluation. Radiographically, the Larsen classification was used and at follow-up radiolucencies and signs of migration were registered. The implants used in this study were the EPF-PLUS® acetabular component and the SL-PLUS® femoral component (PLUS Endoprothetik AG, Rotkreuz-CH). The EPF-PLUS® acetabular component is a novel modular press-fit cup. Its shell has a triple radius profile on cross-section, thereby creating a gradual lowering of the polar part of the cup. This produces a small gap of about 2 mm. between the acetabulum and the pole of the cup. Therefore, forces are mainly transmitted to the peripheral part of the acetabulum, leading to an enhanced primary stability. Originally, the shell had a gritblasted surface for osseointegration. Since 1996, the outer surface of the cup has been coated with a ground layer of pure titanium and a superficial layer of a crystalline hydroxyapatite (Ti-HA). The gritblasted version was used in 14 hips (1995–1996), the Ti-HA coated version in 71 hips. In 68 hips the cup was implanted by press-fit fixation, in 17 screws were added.
Larsen classification was as follows: 0-1: 6; 3: 17; 4: 60; 5: 2. At follow-up, 5 patients (6 THAs) were deceased. Deep infection required revision in one hip. Another revision was carried out for recurrent dislocations. One grit-blasted cup developed late subsidence and was revised almost 4 years postoperatively. One Ti-HA coated cup failed early due to severe acetabular bone loss. Finally, one femoral component developed a varus tilt and became symptomatic 2 years after implantation, requiring revision. In all 62 patients with 74 THAs in follow-up cup and stem are functioning well, both clinically and radiographically. Harris Hip Score increased from 36. 6 (SD 17. 7) to 87. 9 (SD 11. 8).
The medium-term results of the EPF®-PLUS cup show that its primary stability is good and that, as the polar gap rapidly disappears, osseointegration is secure. Only severe acetabular deficiency appears to be a contra-indication for this implant. Also, the SL-PLUS® stem performs well in inflammatory arthritis.
Aims. The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following femoral neck fracture. Methods. Data collection was performed using the German Arthroplasty Registry (EPRD). In HA and THA following femoral neck fracture, fixation method was divided into cemented and uncemented prostheses and paired according to age, sex, BMI, and the Elixhauser Comorbidity Index using Mahalanobis distance matching. Results. Overall in 13,612 cases of intracapsular femoral neck fracture, 9,110 (66.9%) HAs and 4,502 (33.1%) THAs were analyzed. Infection rate in HA was significantly reduced in cases with use of antibiotic-loaded cement compared with
To compare complications, survivorship and results in 2 groups of Furlong-HAP Active, one with ceramic-ceramic and the other with metal-XLPE friction pair. Prospective, non-randomized, comparison of 2 series of JRI
Radiostereometric analysis (RSA) is a technique that can be used to measure in-vivo micro-motion of the components of hip arthroplasty. 86 patients received a titanium custom-made prosthesis. The average age was 64 year (20y –84y). During the study 30 patients out of 86 received a cementless femoral stem. The choice of stem fixation is determined by the quality of the bone. In all cases a 36 mm cobalt chromium head is used. Spherical tantalum markers, chosen because of the proven biocompatibility, were inserted into stable locations in the femoral bone during surgery using a specialized insertion tool, according to the protocol. Evaluation was done 1, 6, 12, 24, 52 weeks after surgery. Overall subsidence follows a parallel pattern for the cemented and
Background: Measurement of quality of life (QOL) and functional status provides important additional information for priority setting in health policy formulation and resource allocation. Our aim was to define the differences in the health-related quality of life between hip artroplasties with cementation and without cementation. The last objective was to reunite evidences on the advantages and disadvantages of both systems of hip arthroplasty fixation. Methods: We analyzed a random sample of patients in surgical waiting list of total hip arthroplasty, between 65 and 75 years, divided in two groups of 40 patients who received a cemented or uncemented THA, respectively. We compared the pre-operative characteristics and at a year after operation changes in the Nottingham Health Profile (NHP) and SF-12 self-administered questionnaires. We also performed the specific Harris hip score. To make the different scoring systems comparable, all scores were transformed to a 0-to 100-point scale, with 100 points indicating best health. Differences among these groups were compared using the Mann-Whitney U test. Results: All patients increased their QOL scores. Both groups had similar QOL scores before surgery. At 1 year, patients with the
Introduction: We studied the survival of primary total hip arthroplasty (THA) in patients undergoing surgery because of rheumatoid arthritis (RA) and compared our results to the survival of primary THA in patients undergoing surgery because of osteoarthritis (OA). Furthermore, we evaluated the effect of primary THA-survival in RA-patients concerning multiple confounders such as age, gender, comorbidity, and cemented/
Aims: Infection of total hip replacement still is considered a devastating complication. One stage revision, meaning removal of implant and debris together with insertion of a new prosthesis during the same operation, reduces rehabilitation time and costs. To overcome the disadvantages of using cement, uncemented techniques seem to be favourable. Methods: After removal of the implants debridement is performed as in conventional septic surgery. After thorough cleaning and rinsing, bone voids are filled with bone graft using an impaction technique. We use cancellous bone that is free from antigenic material but intact structures concerning collagen and mineral content. The bone is impregnated with high loads of antibiotic, using a proprietory incubation technique. There are two options of antibiotic impregnation: vancomycin or tobramycin. The impregnation procedure guarantees high levels of antibiotics at the grafting site for several weeks during which the antibiotic is released into the surrounding. Systemic drug levels usually are undetectable. Consequently an
This study aimed to investigate the optimal sagittal positioning of the uncemented femoral component in total knee arthroplasty to minimize the risk of aseptic loosening and periprosthetic fracture. Ten different sagittal placements of the femoral component, ranging from -5 mm (causing anterior notch) to +4 mm (causing anterior gap), were analyzed using finite element analysis. Both gait and squat loading conditions were simulated, and Von Mises stress and interface micromotion were evaluated to assess fracture and loosening risk.Aims
Methods
Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following total hip arthroplasty (THA) in the presence of a well-fixed acetabular shell. The liner can be fixed either with the original locking mechanism or by being cemented within the acetabular component. Whether the method used for fixation of the HXLPE liner has any bearing on the long-term outcomes is still unclear. Data were retrieved for all patients who underwent isolated acetabular component liner exchange surgery with a HXLPE component in our institute between August 2000 and January 2015. Patients were classified according to the fixation method used (original locking mechanism (n = 36) or cemented (n = 50)). Survival and revision rates were compared. A total of 86 revisions were performed and the mean duration of follow-up was 13 years.Aims
Methods
Introduction. Titanium nitride (TiN) coatings are used in total hip arthroplasty to reduce friction of bearing couples or to decrease the allergic potential of orthopaedic alloys. Little is known about performance of currently manufactured implants, since only few retrieval studies were performed, furthermore they included a small number of implants manufactured over 15 years ago. Aim of study. To examine wear and degradation of retrieved TiN coated femoral heads articulating with ultra-high molecular weight polyethylene (UHMWPE). Methods. We included eight femoral heads with a made od TiAl6V4 alloy and coated with TiN using Physical Vapour Deposition (PVD). All heads (28 and 32 mm) were retrieved after at least 12 months of use (range 12–56). The reason for revision was aseptic loosening in 6 cases, septic loosening in one case and recurrent dislocations (five episodes) in one
Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An
Introduction. Cemented hemiarthroplasty for neck of femur fractures has been advocated over uncemented hemiarthroplasty due to better post-operative recovery and patient satisfaction. However, studies have shown adverse effects of bone cement on the cardio-respiratory system which may lead to higher morbidity and mortality. Therefore, in some institutes, the use of an
Displaced fractures of the neck of femur are routinely treated in the elderly by either cemented hemiarthoplasty, in the fit, or uncemented hemiarthroplasty, in the less fit. In Scotland the Scottish Intercollegiate Guidelines Network (SIGN) guidelines are followed to identify which patients should have a cemented prosthesis. This is based on cardiovascular status, and the age and fragility of the patient. An
Purpose of study:. The purpose of the study is to evaluate the changes in peri-prosthetic bone mineral density following cemented and cementless total hip arthroplasty over a follow up period of 1 year. Description of methods:. Ethics approval was sought and granted by the South African Medical Association Research Ethics Committee (SAMAREC). Patient consent for participation was obtained. Recruitment of the cohort took place over 2 years. Patients received an uncemented (Synergy) or cemented (Spectron) prosthesis as clinically appropriate. Functional status according to the University of California Los Angeles activity scale (UCLA scale) and bone mineral density as measured by Dual Energy X-ray Absorptiometry (DEXA) was assessed pre-operatively and at 3 months, 6 months and 12 months post-operatively. An independent Contract Research Organisation was used to monitor the site. Summary of results:. As at August 2010, 59 unique patients had undergone 59 hip replacements, and 7 patients (8.5%) were still due their 12 month evaluation. The mean UCLA scored showed a marked and steady improvement post-operatively, with most of the gain demonstrated by 3 months. When evaluating all patients, the mean pre-operative values for Gruen Zones 2, 4, and Net were significantly lower than the mean 12 month values. When evaluating patients who received the
The ABG total hip prosthesis had been studied to prevent any kind of stress shielding and to allow the localization of the loads in the metaphiseal region of the femur. The aim of this study was to analize the effective behaviour of the loads in long-term implants and the possible correlations of those findings with the clinical situation of the patients. We considered 87 total hip arthroplasty implants executed from 1989 to 1995 and performed by using Anatomique Benoist Girard I
Introduction: The distorted anatomy in Developmental Dysplasia of the Hip (DDH) makes a total hip arthroplasty (THA) a challenging procedure. The purpose of the current study is to report the midterm results after uncemented primary hip arthroplasty using S ROM prosthesis in a prospective series of patients with hip dysplasia. Methods: We performed 22 uncemented total hip replacements using S ROM prosthesis in 21 (12 female and 9 male) patients with hip dysplasia. The means age at the time of hip surgery was 41.8 (22 to 64) years. The mean follow-up was 6.3 (3.8 to 9.6) years. In 9 (40.9%) patients the operative treatment of DDH was performed during the early childhood (femoral osteotomy in 6 and pelvic osteotomy in 3). All patients were evaluated clinically and radiologically. The femoral head displacement prior to THA surgery was classified according to Crowe at al. classification (4 hips were type1, 2 type2, 10 type3 and 6 type 4). Results: The average Harris Hip Score improved from 29.48 to 72.76 (44 to 99) and the average Oxford hip score is 31.22 (12 to 47). The range of flexion is 60°–120° (average 83.23) and abduction is 10°–40°(average 22.94). None of the hips has dislocated. Radiolucent lines were noted around the femoral stem in one case. None of the cases have developed osteolysis around femoral prosthesis. In one patient (4.5%), revision hip surgery was done for aseptic loosening of cemented acetabular cup. Discussion: The midterm results of total hip replacement in DDH using S ROM