Advertisement for orthosearch.org.uk
Results 1 - 20 of 4822
Results per page:
Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 18 - 18
1 Jan 2022
Singhal A Jayaraju U Kaur K Clewer G
Full Access

Abstract. Background. With the increasingly accepted method of suprapatellar tibial nailing for tibial shaft fractures, we aimed to compare intraoperative and postoperative outcomes of infrapatellar (IP) vs suprapatellar (SP) tibial nails. Methods. A retrospective cohort analysis of 58 patients. 34 SP tibial nails over 3 years versus 24 IP tibial nails over a similar time frame. We compared; radiation exposure, patient positioning time (PPT), non-union rate and follow-up time. Knee pain in the SP group was evaluated, utilising the Hospital for Special Surgery (HSS) Knee injury and Osteoarthritis outcome score (KOOS). Results. 58 patients with a mean age of 43 years were included. Mean intraoperative radiation dose for SP nails was 61.78cGy (range 11.60 to 156.01cGy) vs 121.09cGy (range 58.01 to 18.03cGy) for IP nails (p < 0.05). Mean PPT for SP nails was 10 minutes vs 18 minutes for IP nails (p < 0.05). All fractures united in the SP group vs one non-union in the IP group. Mean follow-up was 5.5 months vs 11 months in the SP and IP group respectively. Mean KOOS was 7 (range 0 to 22) at 6 months for the SP group. Conclusion. The semi extended position (SP group) leads to reduced radiation exposure because of ease of imaging. All Patients in the SP group showed improved outcomes, with shorter follow-up and fracture union. The KOOS revealed SP nail patients had minimal pain and good knee function. This study establishes a management and PROMs baseline for ongoing evaluation of SP nails


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 57 - 57
17 Apr 2023
Bae T Baek H Kwak D
Full Access

It is still difficult to determine an appropriate hinge position to prevent fracture in the lateral cortex of tibia in the process of making an open wedge during biplane open wedge high tibial osteotomy. The objective of this study was to present a biomechanical basis for determining the hinge position as varus deformity. T Three-dimensional lower extremity models were constructed using Mimics. The tibial wedge started at 40 mm distal to the medial tibial plateau, and osteotomy for three hinge positions was performed toward the head of the fibula, 5 mm proximal from the head of the fibula, and 5 mm distal from the head of the fibula. The three tibial models were made with varus deformity of 5, 10, 15 degrees with heterogeneous material properties. These properties were set to heterogeneous material properties which converted from Hounsfield's unit to Young's modulus by applying empirical equation in existing studies. For a loading condition, displacement at the posterior cut plane was applied referring to Hernigou's table considering varus deformity angle. All computational analyses were performed to calculate von-mises stresses on the tibial wedges. The maximum stress increased to an average of 213±9% when the varus angle was 10 degrees compared to 5 degrees and increased to an average of 154±8.9% when the varus angle was 15 degrees compared to 10 degrees. In addition, the maximum stress of the distal position was 19 times higher than that of the mid position and 5 times higher than that of the proximal position on average. Conclusion:. For varus deformity angles, the maximum stress of the tibial wedge tended to increase as the varus deformity angle increased. For hinge position of tibial wedge, maximum stress was the lowest in the mid position, while the highest in the distal position. *This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (NRF-2022R1A2C1009995)


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 47 - 47
1 Apr 2022
Myatt D Stringer H Mason L Fischer B
Full Access

Introduction. Diaphyseal tibial fractures account for approximately 1.9% of adult fractures. Several studies demonstrate a high proportion of diaphyseal tibial fractures have ipsilateral occult posterior malleolus fractures, this ranges from 22–92.3%. Materials and Methods. A retrospective review of a prospectively collected database was performed at Liverpool University Hospitals NHS Foundation Trust between 1/1/2013 and 9/11/2020. The inclusion criteria were patients over 16, with a diaphyseal tibial fracture and who underwent a CT. The articular fracture extension was categorised into either posterior malleolar (PM) or other fracture. Results. 764 fractures were analysed, 300 had a CT. There were 127 intra-articular fractures. 83 (65.4%) cases were PM and 44 were other fractures. On univariate analysis for PM fractures, fibular spiral (p=.016) fractures, no fibular fracture(p=.003), lateral direction of the tibial fracture (p=.04), female gender (p=.002), AO 42B1 (p=.033) and an increasing angle of tibial fracture. On multivariate regression analysis a high angle of tibia fracture was significant. Other fracture extensions were associated with no fibular fracture (p=.002), medial direction of tibia fracture (p=.004), female gender (p=.000), and AO 42A1 (p=.004), 42A2 (p=.029), 42B3 (p=.035) and 42C2 (p=.032). On multivariate analysis, the lateral direction of tibia fracture, and AO classification 42A1 and 42A2 were significant. Conclusions. Articular extension happened in 42.3%. A number of factors were associated with the extension, however multivariate analysis did not create a suitable prediction model. Nevertheless, rotational tibia fractures with a high angle of fracture should have further investigation with a CT


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 58 - 58
23 Feb 2023
Rahardja R Love H Clatworthy M Young S
Full Access

The optimal method of tibial fixation when using a hamstring tendon autograft in anterior cruciate ligament (ACL) reconstruction is unclear. This study aimed to compare the risk of revision ACL reconstruction between suspensory and interference devices on the tibial side. Prospective data on primary ACL reconstructions recorded in the New Zealand ACL Registry between April 2014 and December 2019 were analyzed. Only patients with a hamstring tendon autograft fixed with a suspensory device on the femoral side were included. The rate of revision ACL reconstruction was compared between suspensory and interference devices on the tibial side. Univariate Chi-Square test and multivariate Cox regression was performed to compute hazard ratios (HR) and 95% confidence intervals (CI) with adjustment for age, gender, time-to-surgery, activity at the time of injury, number of graft strands and graft diameter. 6145 cases were analyzed, of which 59.6% were fixed with a suspensory device on the tibial side (n = 3662), 17.6% fixed with an interference screw with a sheath (n = 1079) and 22.8% fixed with an interference screw without a sheath (n = 1404). When compared to suspensory devices (revision rate = 3.4%), a higher risk of revision was observed when using an interference screw with a sheath (revision rate = 6.2%, adjusted HR = 2.05, 95% CI 1.20 – 3.52, p = 0.009) and without a sheath (revision rate = 4.6%, adjusted HR = 1.81, 95% CI 1.02 – 3.23, p = 0.044). The number of graft strands and a graft diameter of ≥8 mm did not influence the risk of revision. When reconstructing the ACL with a hamstring tendon autograft, the use of an interference screw, with or without a sheath, on the tibial side has a higher risk of revision when compared to a suspensory device


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 56 - 56
7 Aug 2023
Nicholls K Wilcocks K Shean K Anderson J Matthews A Vachtsevanos L
Full Access

Abstract. Introduction. Compared to the standard Tomofix plate, the anatomical Tomofix medial high tibial (MHT) plate has been shown to improve anatomical fit and post correction tibial contour, following high tibial osteotomy (HTO). Clinical data on surgical complications, osteotomy union rates and survivorship with the anatomical Tomofix MHT plate however remain limited. This study reports mid-term results of HTO surgery, using the anatomical Tomofix MHT plate. Methods. All patients undergoing HTO surgery using the anatomical Tomofix MHT plate between 2017 and 2022 were included in the study. Data on complications, osteotomy union rates and survivorship were collected prospectively and retrospectively analysed. Results. 78 HTO procedures were performed using the anatomical Tomofix plate in 68 patients. Follow-up ranged between 6 weeks and 5 years. Postoperative complications included 5 hinge fractures that united without further intervention, 1 deep vein thrombus and 1 subclinical pulmonary embolism. There were no wound problems and no returns to theatre, other than for planned removal of metalwork at 1 year. All osteotomies united with no loss of correction. Only 1 HTO was successfully revised to a partial medial knee replacement 2.5 years following osteotomy. The 5-year survivorship was 98.7%. Conclusion. The anatomical Tomofix MHT plate achieves excellent biomechanical stability and union rates in HTO surgery, with minimal complications and excellent mid-term HTO survivorship


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 22 - 22
1 Nov 2021
Belvedere C Leardini A Gill R Ruggeri M Fabbro GD Grassi A Durante S Zaffagnini S
Full Access

Introduction and Objective. Medial Knee Osteoarthritis (MKO) is associated with abnormal knee varism, this resulting in altered locomotion and abnormal loading at tibio-femoral condylar contacts. To prevent end-stage MKO, medial compartment decompression is selectively considered and, when required, executed via High Tibial Osteotomy (HTO). This is expected to restore normal knee alignment, load distribution and locomotion. In biomechanics, HTO efficacy may be investigated by a thorough analysis of the ground reaction forces (GRF), whose orientation with respect to patient-specific knee morphology should reflect knee misalignment. Although multi-instrumental assessments are feasible, a customized combination of medical imaging and gait analysis (GA), including GRF data, rarely is considered. The aim of this study was to report an original methodology merging Computed-Tomography (CT) with GA and GFR data in order to depict a realistic patient-specific representation of the knee loading status during motion before and after HTO. Materials and Methods. 25 MKO-affected patients were selected for HTO. All patients received pre-operative clinical scoring, and radiological/instrumental assessments; so far, these were also executed post-operatively at 6-month follow-up on 7 of these patients. State-of-the-art GA was performed during walking and more demanding motor tasks, like squatting, stair-climbing/descending, and chair-rising/sitting. An 8-camera motion capture system, combined with wireless electromyography, and force platforms for GRF tracking, was used together with an own established protocol. This marker-set was enlarged with 4 additional skin-based non-collinear markers, attached around the tibial-plateau rim. While still wearing these markers, all analyzed patients received full lower-limb X-ray in standing posture a CT scan of the knee in weight-bearing Subsequently, relevant DICOMs were segmented to reconstruct the morphological models of the proximal tibia and the additional reference markers, for a robust anatomical reference frame to be defined on the tibia. These marker trajectories during motion were then registered to the corresponding from CT-based 3D reconstruction. Relevant registration matrices then were used to report GRF data on the reconstructed tibial model. Intersection paths of GRF vectors with respect to the tibial-plateau plane were calculated, together with their centroids. Results. Pre-operative clinical and radiological scoring confirmed MKO and associated abnormal varism. The morphological characterization of GRF was successfully achieved pre- and post- HTO on patient-specific tibial plateau. Pre-operative GFR patterns and peaks, including those related to knee joint moments, were observed medially on the knee, as expected. In post-HTO, these resulted lateralized and much closer to the tibial plateau spine, as desired. In detail, when post- is compared to pre-op, the difference of the centroids were, on average, 54.6±18.1 mm (min÷max: 36.7÷72.8 mm) more lateral during walking and 52.5±28.5 mm (24.7÷87.6 mm) during stair climbing. When reported in % of the tibial plateau width, these values became 69.2±20.1 (46.1÷81.4) and 78.1±30.1 (43.4÷98.0), respectively. Post-op also clinical scores and GA revealed a considerable overall improvement, especially in functional performances. Conclusions. The reported novel approach allows a combination of motion data, including GFR, and tibial-plateau morphology. Relevant pre- and post-operative routine application offer a quantification of the effect of the original deformity and executed joint realignment, and an assistance for surgical planning in case of HTO as well as ideally in other orthopedic treatments


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 16 - 16
7 Aug 2023
Arthur L Amin A Rahman A Tu SJ Mellon S Murray D
Full Access

Abstract. Introduction. Anecdotal reports suggest some cementless Oxford Unicompartmental Knee Replacements (OUKRs) have painful early subsidence of the tibial component with valgus rotation and/or posterior tilting. The incidence of subsidence and its association with pain is poorly understood. This radiographic study aimed to evaluate the incidence of tibial subsidence and five-year patient reported outcome measures (PROMs) of a cementless OUKR cohort. Methodology. Cementless OUKRs from a high-volume centre with acceptable post-operative and five-year radiographs were included. Subsidence was determined by measuring the angle of the tibial tray/tibial axis angle and distance between the tibial tray axis and fibula head on anteroposterior and lateral radiographs using a custom MATLAB program. Analysis of 5-year PROMs assessed the relationship between subsidence and pain. Radiographs indicating tibial subsidence were validated by two observers. Results. Radiographs of 94 cementless OUKRs were analysed of which five tibial components had subsided (incidence=5%) with an average of 1.92° varus rotation and 2.97° posterior tilt. Subsidence appeared to occur within the first post-operative year with all tibial components fixed securely at 5 years. Two subsiders had moderate pain (ICOAP=20.5,15.9, AKSS Pain=20,45) and lower Oxford Knee Scores (OKS=26,31) compared to the cohort means (ICOAP=3.91, AKSS Pain=45.9, OKS = 43.6). These two subsiders had BMIs greater than 30. Conclusion. This study found 5% of cementless OUKRs in the cohort underwent tibial subsidence. Subsidence with moderate pain occurred in 2% of cases, and pain may be associated with obesity. A larger study is needed to study subsidence in greater detail


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 45 - 45
1 Feb 2020
Delgadillo L Jones H Noble PC
Full Access

Background. Cementless Total Knee Arthroplasty has been developed to reduce the incidence of failure secondary to aseptic loosening, osteolysis and stress-induced osteopenia, especially in younger and more active patients. However, failures are still more common compared to cemented components, especially those involving the tibia. It is hypothesized that this is caused by incomplete contact between the tibial tray and the underlying bony surface due to: (i) inadequate flatness of the tibial osteotomy, or (ii) failure of implantation to spread the area of contact over the exposed cancellous surface. In the present study we compare the contact area developed during implantation of a cementless tray as a function of the initial flatness of the tibial osteotomy. Method. Eight joint replacement surgeons prepared 14 cadaveric knees for cementless TKR using a standard instrumentation set (ZimmerBiomet Inc). The tibial osteotomy was created using an oscillating bone saw and a 1.27mm blade (Stryker Inc) directed by a slotted cutting guide mounted on an extramedullary rod and fixed to the tibia with pins and screws. The topography of the exposed cancellous surface was captured with a commercial laser scanner (Faro Inc, Halifax, approx. 33,000 surface points). 3D computer models of each tibial surface were generated in a CAD environment (Rapidform, Inuus). After scanning, a cementless tibial tray was implanted on the prepared tibial surface using a manual impactor. The tray-tibia constructs were dissected free of soft tissue, embedded in mounting resin, and sectioned with a diamond wafering saw. Points of bone-tray contact and interface separation were identified by stereomicroscopy and incorporated in the 3D computer models. Maps were generated depicting contacting and non-contacting areas Each model was subdivided into 7 zones for characterizing the distribution of interface contact in terms of anatomic location. Results. The flatness for the tibial osteotomies averaged 1.1±0.35 mm (range: 0.56–1.81mm). After impaction, 79.8±0.3% of the tibial surface had plastically deformed to establish a contacting interface with the implant. 15.1% of the bony surface was within 0.2mm of the tray and 17.6% was within 0.3mm. Gaps large enough to impede ingrowth only occupied 2.6% of the exposed tibial These non-contacting areas were typically located centrally at the ACL, PCL and canal zones. There was an inverse linear relationship between the initial flatness of the tibial osteotomy and the percentage of tray-bone contact. Conclusions. The amount of direct contact between the bone and implant is critical for the development of stability in cementless fixation. We found a relationship between ultimate bony contact and initial flatness. However, we also found that during impaction of the implant, bony contact increased through deformation of the most prominent peaks of the cancellous surface. Interface gaps were consistently observed in central areas of the tibia surface located above the medullary canal which may be reduced through selection of trays with distal keels. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 32 - 32
7 Aug 2023
Nicholls K Petsiou D Wilcocks K Shean K Anderson J Vachtsevanos L
Full Access

Abstract. Introduction. Surgery in patients with high body mass index (BMI) is more technically challenging and associated with increased complications post-operatively. Inferior clinical and functional mid-term results for high BMI patients undergoing high tibial osteotomy (HTO) relative to normal weight patients have been reported. This study discusses the clinical, radiological and functional outcomes of HTO surgery in patients with a high BMI. Method. This is a retrospective study on patients undergoing HTO surgery using the Tomofix anatomical MHT plate between 2017 and 2022, with follow-up period of up to 5 years. The cohort was divided: non-obese (BMI <30 kg/m2) and obese (BMI>30 kg/m2). Pre and post operative functional scores were collected: Oxford Knee Score (OKS), EuroQol-5D and Tegner. Complications, plate survivorship and Mikulicz point recorded. Results. 32 HTO procedures; 19 patients BMI <30 (average 27.0) and 14 patients BMI >30 (average 36.1). In BMI<30 cohort, one readmission for investigation of venous thromboembolism, doppler negative; two complications: hinge fracture and stitch abscess. The five year survivorship of the plate was 100%. In BMI>30 cohort, one readmission for pulmonary embolism; one complication: hinge fracture. The 5 year survivorship of the plate was 93%, 1 conversion to unicompartmental knee replacement. The average OKS improvement was 17 and 18 for BMI <30 and >30 respectively. Mikulicz point change was identical. Conclusion. The Tomofix anatomical MHT plate achieves good outcomes and minimal complications irrespective of BMI. Reduced plate survivorship, thus earlier conversion may be required in the obese, however higher cohort numbers are needed to confirm this


Bone & Joint Open
Vol. 3, Issue 6 | Pages 495 - 501
14 Jun 2022
Keohane D Sheridan GA Masterson E

Aims. Total knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component. Methods. A retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option). Results. Between 2013 and 2016, 352 NexGen TKAs were carried out on 331 patients. A total of 62 TKAs have been revised to date, giving an all-cause revision rate of 17.6% at a minimum of five years. Three of these revisions were due to infection. Overall, 59 of the revisions were performed for aseptic loosening (16.7%) of the tibial component. The tibial component was removed intraoperatively without instrumentation due to significant tibial debonding between the implant-cement interface. Conclusion. While overall, we believe that early aseptic loosening is multi-factorial in nature, the significantly high aseptic revision rate, as seen by an experienced fellowship-trained arthroplasty surgeon, has led us to believe that there is a fundamental issue with this NexGen implant design. Continued implant surveillance and rigorous review across all regions using this particular implant is warranted based on the concerning findings described here. Cite this article: Bone Jt Open 2022;3(6):495–501


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 119 - 119
2 Jan 2024
Arthur L Min X Tu S Campi S Mellon S Murray D
Full Access

Tibial periprosthetic fracture is an important complication of the Oxford Unicompartmental Knee Replacement (OUKR). Primary fixation of cementless OUKR tibial components relies on the interference-fit of the ‘keel’ and a slot in the proximal tibia. Clinically used double blade keel saws (DKS) create slots with two grooves, generating stress concentrations where fractures may initiate. This study aimed to investigate slot factors that may influence incidence of tibial periprosthetic fractures. Slots were made in PCF20 polyurethane foam using the DKS plus/minus adjuvant rasping, single blade keel saw (SKS), and rasp-only. Round and square slots were machined with milling cutters. Compact tensile tests were conducted per ASTM E399 to determine tensile load to fracture (TLTF) and results were validated using bovine tibia. Cementless OUKR components were implanted into slots in custom polyurethane blocks and compressed to failure to determine anatomical load to fracture (ALTF). A custom MATLAB program calculated slot roundness from cross-sectional images. Round slots had higher TLTF (29.5N, SD=2.7) than square (25.2N, SD=1.7, p<0.05) and DKS slots (23.3N, SD=2.7, p<0.0001). Fractures occurred at the round slot apices, square slot corners, and deepest DKS slot grooves. ALTF was not significantly different between square and round slots. Adjuvant rasping made DKS slots significantly rounder, resulting in significantly higher TLTF, but rasping did not increase ALTF. ALTF was significantly higher for SKS (850N, SD=133, p<0.01) and rasp-only (912N, SD=100, p<0.001) slots compared to standard DKS slots (703N, SD=81). Round keel slots minimise stress concentrations and increase TLTF but do not increase ALTF. The SKS and rasp-only slots retain material at slot ends and have significantly higher ALTF. Future studies should assess saw blades that retain material and round slot ends to evaluate if their use may significantly reduce the incidence of tibial periprosthetic fracture


Bone & Joint Research
Vol. 10, Issue 8 | Pages 467 - 473
2 Aug 2021
Rodríguez-Collell JR Mifsut D Ruiz-Sauri A Rodríguez-Pino L González-Soler EM Valverde-Navarro AA

Aims. The main objective of this study is to analyze the penetration of bone cement in four different full cementation techniques of the tibial tray. Methods. In order to determine the best tibial tray cementation technique, we applied cement to 40 cryopreserved donor tibiae by four different techniques: 1) double-layer cementation of the tibial component and tibial bone with bone restrictor; 2) metallic cementation of the tibial component without bone restrictor; 3) bone cementation of the tibia with bone restrictor; and 4) superficial bone cementation of the tibia and metallic keel cementation of the tibial component without bone restrictor. We performed CT exams of all 40 subjects, and measured cement layer thickness at both levels of the resected surface of the epiphysis and the endomedular metaphyseal level. Results. At the epiphyseal level, Technique 2 gave the greatest depth compared to the other investigated techniques. At the endomedular metaphyseal level, Technique 1 showed greater cement penetration than the other techniques. Conclusion. The best metaphyseal cementation technique of the tibial component is bone cementation with cement restrictor. Additionally, if full tibial component cementation is to be done, the cement volume used should be about 40 g of cement, and not the usual 20 g. Cite this article: Bone Joint Res 2021;10(8):467–473


Bone & Joint Open
Vol. 5, Issue 1 | Pages 46 - 52
19 Jan 2024
Assink N ten Duis K de Vries JPM Witjes MJH Kraeima J Doornberg JN IJpma FFA

Aims. Proper preoperative planning benefits fracture reduction, fixation, and stability in tibial plateau fracture surgery. We developed and clinically implemented a novel workflow for 3D surgical planning including patient-specific drilling guides in tibial plateau fracture surgery. Methods. A prospective feasibility study was performed in which consecutive tibial plateau fracture patients were treated with 3D surgical planning, including patient-specific drilling guides applied to standard off-the-shelf plates. A postoperative CT scan was obtained to assess whether the screw directions, screw lengths, and plate position were performed according the preoperative planning. Quality of the fracture reduction was assessed by measuring residual intra-articular incongruence (maximum gap and step-off) and compared to a historical matched control group. Results. A total of 15 patients were treated with 3D surgical planning in which 83 screws were placed by using drilling guides. The median deviation of the achieved screw trajectory from the planned trajectory was 3.4° (interquartile range (IQR) 2.5 to 5.4) and the difference in entry points (i.e. plate position) was 3.0 mm (IQR 2.0 to 5.5) compared to the 3D preoperative planning. The length of 72 screws (86.7%) were according to the planning. Compared to the historical cohort, 3D-guided surgery showed an improved surgical reduction in terms of median gap (3.1 vs 4.7 mm; p = 0.126) and step-off (2.9 vs 4.0 mm; p = 0.026). Conclusion. The use of 3D surgical planning including drilling guides was feasible, and facilitated accurate screw directions, screw lengths, and plate positioning. Moreover, the personalized approach improved fracture reduction as compared to a historical cohort. Cite this article: Bone Jt Open 2024;5(1):46–52


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 48 - 48
4 Apr 2023
Yang Y Li Y Pan Q Wang H Bai S Pan X Ling K Li G
Full Access

Treatment for delayed wound healing resulting from peripheral vascular diseases and diabetic foot ulcers remain a challenge. A novel surgical technique named Tibial Cortex Transverse Transport has been developed for treating peripheral ischaemia, with encouraging clinical effects. However, its underlying mechanisms remain unclear. In present study, we aimed to explore the wound healing effects after undergoing this novel technique via multiple ways. A novel rat model of Tibial Cortex Transverse Transport was established with a designed external fixator and effects on wound healing were investigated. All rats were randomized into 3 groups, with 12 rats per group: sham group (negative control), fixator group (positive control) and Tibial Cortex Transverse Transport group. Laser speckle perfusion imaging, vessel perfusion, histology and immunohistochemistry were used to evaluate the wound healing processes. Gross and histological examinations showed that Tibial Cortex Transverse Transport technique accelerated wound closure and enhanced the quality of the newly formed skin tissues. In Tibial Cortex Transverse Transport group, HE staining demonstrated a better epidermis and dermis recovery, while immune-histochemical staining showed that Tibial Cortex Transverse Transport technique promoted local collagen deposition. Tibial Cortex Transverse Transport technique also benefited to angiogenesis and immunomodulation. In Tibial Cortex Transverse Transport group, blood flow in the wound area was higher than that ofother groups according to laser speckle imaging with more blood vessels observed. Enhanced neovascularization was seen in the Tibial Cortex Transverse Transport group with double immune-labelling of CD31 and α-SMA. The M2 macrophages at the wound site in the Tibial Cortex Transverse Transport group was also increased. Tibial cortex transverse transport technique accelerated wound healing through enhanced angiogenesis and immunomodulation


Bone & Joint Open
Vol. 5, Issue 1 | Pages 20 - 27
17 Jan 2024
Turgeon TR Vasarhelyi E Howard J Teeter M Righolt CH Gascoyne T Bohm E

Aims. A novel enhanced cement fixation (EF) tibial implant with deeper cement pockets and a more roughened bonding surface was released to market for an existing total knee arthroplasty (TKA) system.This randomized controlled trial assessed fixation of the both the EF (ATTUNE S+) and standard (Std; ATTUNE S) using radiostereometric analysis. Methods. Overall, 50 subjects were randomized (21 EF-TKA and 23 Std-TKA in the final analysis), and had follow-up visits at six weeks, and six, 12, and 24 months to assess migration of the tibial component. Low viscosity bone cement with tobramycin was used in a standardized fashion for all subjects. Patient-reported outcome measure data was captured at preoperative and all postoperative visits. Results. The patient cohort mean age was 66 years (SD seven years), 59% were female, and the mean BMI was 32 kg/m. 2. (SD 6 kg/m. 2. ). Mean two-year subsidence of the EF-TKA was 0.056 mm (95% confidence interval (CI) 0.025 to 0.086) versus 0.006 mm (95% CI -0.029 to 0.040) for the Std-TKA, and the two-year maximum total point motion (MTPM) was 0.285 mm (95% upper confidence limit (UCL) ≤ 0.363) versus 0.346 mm (95% UCL ≤ 0.432), respectively, for a mean difference of -0.061 mm (95% CI -0.196 to 0.074). Inducible displacement also did not differ between groups. The MTPMs between 12 and 24 months for each group was below the published threshold of 0.2 mm for predicting early aseptic loosening (p < 0.001 and p = 0.001, respectively). Conclusion. Both the enhanced fixation and the standard tibial implant design showed fixation with a predicted low risk of long-term aseptic loosening. Cite this article: Bone Jt Open 2024;5(1):20–27


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 143 - 143
4 Apr 2023
Kröger I Pätzold R Brand A Wackerle H Klöpfer-Krämer I Augat P
Full Access

Tibial shaft fractures require surgical stabilization preferably by intramedullary nailing. However, patients often report functional limitations even years after the injury. This study investigates the influence of the surgical approach (transpatellar vs. parapatellar) on gait performance and patient reported outcome six months after surgery. Twenty-two patients with tibial shaft fractures treated by intramedullary nailing through a transpatellar approach (TP: n=15, age 41±15, BMI 24±3) or a parapatellar approach (PP: n=7, age 34±15, BMI 23±2) and healthy, matched controls (n=22, age 39±13, BMI 24±2) were assessed by instrumented motion analysis six months after intramedullary nailing. Short musculoskeletal function assessment questionnaire (SMFA) as well as kinematic and kinetic gait data were collected during level walking. Comparisons among approach methods and control group were performed by analysis of variance and Mann-Whitney test. Six months after surgery, knee kinetics in both groups differed significantly compared to controls (p <.04). The approach method affected gait speed (TP: p = .002; PP: p = .08) and knee kinematics in the early stance phase (TP: p = .011; PP: p = .082), with the parapatellar approach showing a more favorable outcome. However, the difference between patient groups was not significant for any of the assessed gait parameters (p > .2). Also, no differences could be found in the bother index (BI) or function index (FI) of SMFA between surgical approach methods (BI: TP: Mdn = 7.2, PP: Mdn = 9.4; FI: TP: Mdn = 10.3, PP: Mdn = 9.2, p > .7). Our study demonstrates, that six months after surgery for tibial shaft fractures functional limitations remain. These limitations appear not to be different for either a trans- or a parapatellar approach for the insertion of the intramedullary nail. The findings of this study are limited by the relatively short follow up time period and small number of patients. Future studies should investigate the source of the functional limitation after intramedullary nailing of tibial shaft fractures


Bone & Joint Research
Vol. 11, Issue 4 | Pages 229 - 238
11 Apr 2022
Jaeger S Eissler M Schwarze M Schonhoff M Kretzer JP Bitsch RG

Aims. One of the main causes of tibial revision surgery for total knee arthroplasty is aseptic loosening. Therefore, stable fixation between the tibial component and the cement, and between the tibial component and the bone, is essential. A factor that could influence the implant stability is the implant design, with its different variations. In an existing implant system, the tibial component was modified by adding cement pockets. The aim of this experimental in vitro study was to investigate whether additional cement pockets on the underside of the tibial component could improve implant stability. The relative motion between implant and bone, the maximum pull-out force, the tibial cement mantle, and a possible path from the bone marrow to the metal-cement interface were determined. Methods. A tibial component with (group S: Attune S+) and without (group A: Attune) additional cement pockets was implanted in 15 fresh-frozen human leg pairs. The relative motion was determined under dynamic loading (extension-flexion 20° to 50°, load-level 1,200 to 2,100 N) with subsequent determination of the maximum pull-out force. In addition, the cement mantle was analyzed radiologically for possible defects, the tibia base cement adhesion, and preoperative bone mineral density (BMD). Results. The BMD showed no statistically significant difference between both groups. Group A showed for all load levels significantly higher maximum relative motion compared to group S for 20° and 50° flexion. Group S improved the maximum failure load significantly compared to group A without additional cement pockets. Group S showed a significantly increased cement adhesion compared to group A. The cement penetration and cement mantle defect analysis showed no significant differences between both groups. Conclusion. From a biomechanical point of view, the additional cement pockets of the component have improved the fixation performance of the implant. Cite this article: Bone Joint Res 2022;11(4):229–238


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_II | Pages 186 - 186
1 Feb 2004
Manolarakis G Papakostidis C Xanthis A Paxinos G Chrysovitsinos I
Full Access

Introduction: The results of high tibial osteotomy tend to deteriorate over time. Consequently, a certain percentage of these patients will ultimately undergo TKR for the symptomatic treatment of the osteoarthritis of their knees. High tibial osteotomy, on the other hand, produces anatomic alterations around ipsilateral knee joint, that might bring about technical difficulties during the performance of TKR procedure. One of these difficulties has to do with the alteration of relationship between tibial anatomic axis and ipsilateral plateau. Aim: The radiographic evaluation of the alteration of the relative position of the tibial medullary canal with respect to the ipsilateral plateau, after high tibial, closed-wedge osteotomy, with stable fixation. Material – Method: For this aim, we studied 49 knees (in 45 patients), that had undergone high tibial valgus osteotomy, between 1990 and 1997, in our Department. The relative change of tibial anatomic axis was determined by calculating the index of “tibial condylar offset” in the AP view of each knee during three follow up examinations done at the direct post operative period, three months post operatively and at least one year post operatively. Results: There was a definite tendency of medialization of the tibial anatomic axis post operatively (and, consequently, of the tibial medullary canal) with respect to the centre of the ipsilateral plateau. This was in direct proportion to the degree of valgus correction. The mean percentage of post operative alteration of “tibial condylar offset”, in comparison to its preoperative value, was 19%. Conclusions: The insertion of a stemmed tibial implant, in a knee that has previously undergone high tibial osteotomy, through the centre of the tibial plateau runs a certain risk of abutment on the lateral cortex, due to the medialization of the tibial medullary canal with respect to the centre of tibial plateau. The above observations show the importance of a thorough pre-op plan of every TKR procedure that has been preceded by high tibial osteotomy


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 37 - 37
23 Feb 2023
van der Gaast N Huitema J Brouwers L Edwards M Hermans E Doornberg J Jaarsma R
Full Access

Classification systems for tibial plateau fractures suffer from poor interobserver agreement, and their value in preoperative assessment to guide surgical fixation strategies is limited. For tibial plateau fractures four major characteristics are identified: lateral split fragment, posteromedial fragment, anterior tubercle fragment, and central zone of comminution. These fracture characteristics support preoperative assessment of fractures and guide surgical decision-making as each specific component requires a respective fixation strategy. We aimed to evaluate the additional value of 3D-printed models for the identification of tibial plateau fracture characteristics in terms of the interobserver agreement on different fracture characteristics. Preoperative images of 40 patients were randomly selected. Nine trauma surgeons, eight senior and eight junior registrars indicated the presence or absence of four fracture characteristics with and without 3D-printed models. The Fleiss kappa was used to determine interobserver agreement for fracture classification and for interpretation, the Landis and Koch criteria were used. 3D-printed models lead to a categorical improvement in interobserver agreement for three of four fracture characteristics: lateral split (Kconv = 0.445 versus K3Dprint = 0.620; P < 0.001), anterior tubercle fragment (Kconv = 0.288 versus K3Dprint = 0.449; P < 0.001) and zone of comminution (Kconv = 0.535 versus K3Dprint = 0.652; P < 0.001). The overall interobserver agreement improved for three of four fracture characteristics after the addition of 3D printed models. For two fracture characteristics, lateral split and zone of comminution, a substantial interobserver agreement was achieved. Fracture characteristics seem to be a more reliable way to assess tibial plateau fractures and one should consider including these in the preoperative assessment of tibial plateau fractures compared to the commonly used classification systems


Bone & Joint Open
Vol. 5, Issue 5 | Pages 385 - 393
13 May 2024
Jamshidi K Toloue Ghamari B Ammar W Mirzaei A

Aims. Ilium is the most common site of pelvic Ewing’s sarcoma (ES). Resection of the ilium and iliosacral joint causes pelvic disruption. However, the outcomes of resection and reconstruction are not well described. In this study, we report patients’ outcomes after resection of the ilium and iliosacral ES and reconstruction with a tibial strut allograft. Methods. Medical files of 43 patients with ilium and iliosacral ES who underwent surgical resection and reconstruction with a tibial strut allograft between January 2010 and October 2021 were reviewed. The lesions were classified into four resection zones: I. 1. , I. 2. , I. 3. , and I. 4. , based on the extent of resection. Functional outcomes, oncological outcomes, and surgical complications for each resection zone were of interest. Functional outcomes were assessed using a Musculoskeletal Tumor Society (MSTS) score and Toronto Extremity Salvage Score (TESS). Results. The mean age of the patients was 17 years (SD 9.1). At a mean follow-up of 70.8 months (SD 50), the mean functional outcomes were 24.2 points (SD 6.3) for MSTS and 81 points (SD 11) for TESS. The mean MSTS and TESS scores were associated with the iliac resection zone (< 0.001). Nine patients (20.9%) had local recurrence. The recurrence was not associated with the zone of iliac resection (p = 0.324). The two-year disease-free survival of the patients was 69.4%. The mean time to graft union was longer in patients with the I. 4. resection zone (p < 0.001). The complication rate was 34.9%, and nerve palsy (11.6%) was the most common. The rate of surgical complications was not associated with the resection zone. Conclusion. Reconstruction using tibial strut allograft is an efficient procedure after the resection of the ilium and iliosacral ES. Functional outcomes and complications of iliac ES depend on the resection zone, and inferior outcomes could be generally expected when more segments of the pelvic ring are resected, even if it is reconstructed. Cite this article: Bone Jt Open 2024;5(5):385–393