Background. The
Purpose: We report preliminary results after treatment of humeral fracturs with a
Objective: Osteoporotic fractures of the distal forearm are demanding in terms of operative therapy and implants used. Volar fixed angle plating has become a standard procedure for these fractures. Recently intra-medullary nailing was introduced in clinical practice for the use in distal radial fractures. This randomized multi-center study compares both fixation techniques in terms of clinical and radiological outcome as well as quality of life score. Material and Methods: Up to now a total of 85 patients with extra- and intraarticular unstable fractures of the distal radius were included. 53 patients (Targon DR®, B. Braun-Aesculap: n=24; 2.4 mm plate, Synthes: n=29) completed the 6 months follow-up. Follow up examinations included an osteodensitometry using pQCT, X-ray analysis and a detailed clinical function examination. In addition the SF36 questionaire for quality of life assessment was carried out. Results: The operation time for volar plating was significantly longer than for intramedullary nailing (50.3±20.2 min versus 40.2±13.4 min), as was the time in hospital (5.4±1.8 days versus 2.2±0.6 days) (MW±SD; p<
0.05; Student-t-Test, post hoc: Bonferonni). The Gartland an Werley function score averaged 2.7±1.1 versus 1.9±0.8 for volar plating in comparision to treatment with the
Background: The purpose of this study was to compare the stability of the 2.4 mm palmar locking compression plate (LCP) and a new intramedullary nail-plate-hybrid
Purpose of the study: To compare the DHS plate fixation with the
Background: Reverse obliquity and transverse fractures of the proximal femur represent a distinct fracture pattern in which the mechanical forces displace the femur medially thus increasing the risk of fixation failure. There is a paucity of published literature in this area of trauma. This study constitutes the largest series of such fractures. Methods: Using the hip fracture registry at this institution 101 reverse obliquity and transverse fracture patterns were identified from 3336 consecutive hip fractures. All surviving patients were followed up for 1 year. Results: Of 100 patients treated operatively, 59 were treated with 1350 sliding hip screws (SHS), 22 were treated with 1350 sliding hip screw devices designed to resist medialization (3 sliding hip screws with trochanteric plate and 19 Medoff plates), and 19 were treated with intramedullary sliding hip screw devices (1 short Gamma nail, 9 long Gamma nails, 6 Reconstruction nails, 6 long
In Displaced Intracapsular Hip Fractures (ICHF) in young active patients, preservation of the femoral head and its blood supply are of high importance and urgent surgical treatment with anatomic reduction and internal fixation is the preferred intervention. Due to the strong varus displacement shear forces exerted across the hip, there are relatively high complication rates after fixation. There is no consensus regarding the optimal fixation device or technique. This retrospective study compared closed reduction internal fixation method using cannulated cancellous screw (CCS) with the
Fractures of the proximal femur at the level of the lesser trochanter (reversed and transverse fracture lines, Evans classification type II, AO classification A3 fractures) are known to have an increased risk of fixation failure. 58 patients with such a fracture were randomised to have the fracture fixed with either an intramedullary nail (220 mm
Fractures of the proximal femur at the level of the lesser trochanter (reversed and transverse fracture lines, Evans classification type II, AO classification 31. A3 fractures) are known to have an increased risk of fixation failure. 53 patients with such a fracture were randomised to have the fracture fixed with either an intramedullary nail (220 mm
400 patients with a trochanteric hip fracture were randomised to fixation with either a 220mm long
The
Distal radius fractures are typical and frequent fracture of elderly woman with reduced bone density. Thus implant fixation is more difficult. Dorsal and radial comminution are frequent in these patients and so reduction and angle stable osteosynthesis needed. The angle stable plate, often also multidirectional is today the most common stabilisation device. Because of the introduction of bulky and bended implants as the Micronail or
The Sliding Hip Screw (SHS) is currently the treatment of choice for all trochanteric hip fractures. An alternative treatment is the short femoral nail. Earlier designs of these nails were associated with an increased fracture healing complication rate in comparison to the sliding hip screw. The new designs of nails (third generation nails) may however be as good as or even superior to sliding hip screw fixation. We conducted a large randomised trial to compare the
The
Plating displaced proximal humeral fractures is associated with a high rate of screw perforation. Dynamization of the proximal screws might prevent these complications. The aim of this study was to develop and evaluate a new gliding screw concept for plating proximal humeral fractures biomechanically. Eight pairs of three-part humeral fractures were randomly assigned for pairwise instrumentation using either a prototype gliding plate or a standard PHILOS plate, and four pairs were fixed using the gliding plate with bone cement augmentation of its proximal screws. The specimens were cyclically tested under progressively increasing loading until perforation of a screw. Telescoping of a screw, varus tilting and screw migration were recorded using optical motion tracking.Aims
Methods
The June 2012 Trauma Roundup360 looks at: nerve injuries of warfare; the medical complications of earthquakes; the measuring of tissue pressures in compartment syndrome; the risk of plunging through the bone when drilling; bony nonunion and negative pressure therapy; surgery for the posteriorly dislocated hip; whether to use the sliding screw or intramedullary nail for the trochanteric fracture; antegrade interlocking nailing for the distal femoral fracture; and gunshot wounds to the pancreas.