Aims. United Classification System (UCS) B2 and B3 periprosthetic fractures in total hip arthroplasties (THAs) have been commonly managed with modular
Periprosthetic femoral fractures (PFFs) remain a major concern following cementless total hip arthroplasty (THA). This study aimed to evaluate the association between different types of cementless
Objectives. Favourable results for collarless polished
Aims. The aims of this study were to evaluate the incidence of reoperation (all cause and specifically for periprosthetic femoral fracture (PFF)) and mortality, and associated risk factors, following a hemiarthroplasty incorporating a cemented collarless polished
Aims. The aim of this study was to evaluate the suitability of the
Aims. When performing revision total hip arthroplasty using diaphyseal-engaging titanium
Introduction. Neck and cup impingement resulted in producing larger amount of wear and risk for dislocation after total hip arthroplasty. DDH had more complex to adjust combined cup and femoral neck anteversion during surgery. Dislocation is the second most prevalent complication in total hip replacement with a 2–4% incidence. These resulted in significant financial burden to health care system. Sixteen million US dollars or more cost had in Japanese health insurance system every year. Purpose of this study was to evaluate neck-cup impingement with neck changeable M/L
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMD. 119 patients were randomized to receive either a proximally coated dual
Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual
Background. A stem sitting proud (SP) or that above the final rasp position remains in some patients who undergo hip replacement using proximally coated
Introduction. We have investigated the long-term (minimum follow-up period; 10 years) clinical results of the total hip arthroplasty (THA) using K-MAX HS-3
Tapered fluted grit-blasted modular stems have now become established as a successful method of femoral revision. The success of these stems is predicated on obtaining axial stability by milling the femur to a cone and then inserting the tapered prosthesis into that cone. Torsional stability is gained by flutes that cut into the diaphysis. By having modular proximal segments of different lengths, the leg length, offset, and anteversion can be adjusted after the distal stem is fixed. This maximises the chance for the stem to be driven into the canal to whatever level provides maximum stem stability. Modular fluted
Aim of this study was to identify reoperation rates in patients with short oblique and transverse fractures around a well fixed cemented polished
Introduction. The origins of the uncemented tapered wedge hip stem design currently offered by several orthopaedic device companies can be linked back to the cemented Straight Mueller type stem design first used in 1977. The design, a wedge shape with a taper angle of 6 degrees, maintains a single medial curvature for all sizes and increases laterally in the width to accommodate different size femurs. Although evolutionary improvements have been made over the years the basic body geometry of the stem has stayed mainly unchanged with excellent clinical survivorship. Over the past decade, the demographics of hip replacement have changed, with a large increase in younger male patients in the age range of 40 to 60 years. In this study the femoral fit of a novel
The purpose of this study was to investigate the influence of surgical approach on femoral stem version in THA. This was a retrospective database review of 830 THAs in 830 patients that had both preoperative and postoperative CT scans. All patients underwent staged bilateral THAs and received CT-based 3D planning on both sides. Stem version was measured in the second CT-scan and compared to the native neck axis measured in the first CT-scan, using the posterior condyles as the reference for both. Cases were performed by 104 surgeons using either a direct anterior (DAA, n=303) or posterior (PA, n=527) approach and one of four stem designs: quadrangular taper, calcar-guided short
Clinical success of prostheses in joint arthroplasty is ultimately determined by survivorship and patient satisfaction. The purpose of this study was to compare (non-inferiority) a new morphometric designed stem for total hip arthroplasty (THA) against an established comparator. A prospective randomised multi-centre study of 144 primary cementless THA performed by nine experienced orthopaedic surgeons was completed (70 received a fully coated collarless
Clinical success of prostheses in joint arthroplasty is ultimately determined by survivorship and patient satisfaction. The purpose of this study was to compare (non-inferiority) a new morphometric designed stem for total hip arthroplasty (THA) against an established comparator. A prospective randomised multi-centre study of 144 primary cementless THA performed by nine experienced orthopaedic surgeons was completed (70 received a fully coated collarless
Periprosthetic fractures (PPF) of the femur following total hip arthroplasty represent a significant complication with a rising incidence. The commonest subtype is Vancouver B2 type, for which revision to a long uncemented
Dual mobility (DM) is most often used by surgeons to reduce instability in high risk patients. NJR data on DM has not demonstrated a reduction in all cause revision and has reported an increase in revision for peri-prosthetic fracture (PPF). The aim of our study was:. Report outcome of DM used in high-risk patients including non-revision re-operations (dislocation & PPF). Comparison with conventional bearing THA (cTHA) with local, national and NJR benchmarking data. Retrospective cohort assessment of falls risk for patients receiving DM. Prospective F/U of a DM implant since 2016 and enrolled into Beyond Compliance (BC). Primary outcome measure all-cause revision with secondary outcome including any re-operation and Oxford Hip Score (OHS). All patients were risk stratified and considered high risk for instability. Complications were identified via hospital records, clinical coding linkage, NJR and BC. Benchmarking data for comparison was obtained from same data sources we also considered all B type PPF that occurred with cemented polished
Dual mobility (DM) is an established bearing option in Total Hip Arthroplasty (THA). The traditional mono-block DM designs have limited ability for additional fixation, whereas the modular DM designs allow additional screw fixation but limit internal diameter and have the potential to generate metal debris. We report the early results of a CoCrMo alloy mono-block implant manufactured by additive technology with a highly porous ingrowth surface to enhance primary fixation and osseointegration. Prospective follow-up of the Duplex. TM. implant first inserted in March 2016 enrolled into Beyond Compliance (BC). Primary outcome measure was all-cause revision and secondary outcomes dislocation, peri-prosthetic fracture (PPF) and Oxford Hip Score (OHS). Patients were risk stratified and all considered to be high risk for instability. Complications were identified via hospital records, clinical coding linkage using national database and via BC website. 159 implants in 154 patients with a mean age 74.0 years and a maximum F/U of 7 years. Survivorship for all-cause revision 99.4% (95% CI 96.2–99.8). One femoral only revision. Mean gain in OHS 27.4. Dislocation rate 0.6% with a single event. Patients with a cemented Polished