Introduction. Tip apex distance (TAD) is reported as a predictor for cut outs of lag screws in the treatment of intertrochanteric fractures, and surgeons are adviced to strive for
Aims. Proximal femur fractures treatment can involve anterograde nailing with a single or double cephalic screw. An undesirable failure for this fixation is screw cut-out. In a single-screw nail, a tip-apex distance (TAD) greater than 25 mm has been associated with an increased risk of cut-out. The aim of the study was to examine the role of
Background. Dynamic Hip Screw (DHS) is the most frequently used implant in management of intertrochanteric femoral fractures. There is a known statistical relationship between a tip-apex distance (TAD) >25mm and higher rate of implant failure. Our aim was to analyse all DHS procedures performed in our trust from seventeen months and compare their
Tip-apex distance (TAD) has long been discussed as a metric for determining risk of failure in fixation of peritrochanteric hip fractures. This study seeks to investigate risk factors including
Lag screw cut-out is a serious complication of dynamic hip screw fixation in trochanteric hip fractures. Lag screw position is recognised as a crucial factor influencing the occurrence of lag screw cut-out. We propose a modification of the Tip Apex Distance (TAD) and hypothesize that it could enhance the reliability of predicting lag screw cut-out in these injuries. A retrospective study of hip fracture cases was conducted from January 2018 to July 2022. A total of 109 patients were eligible for the final analysis. The modified
Objectives. Different criteria for assessing the reduction quality of trochanteric fractures have been reported. The Baumgaertner reduction quality criteria (BRQC) are relatively common and the Chang reduction quality criteria (CRQC) are relatively new. The objectives of the current study were to compare the reliability of the BRQC and CRQC in predicting mechanical complications and to investigate the clinical implications of the CRQC. Methods. A total of 168 patients were assessed in a retrospective observational study. Clinical information including age, sex, fracture side, American Society of Anesthesiologists (ASA) classification, tip-apex distance (TAD), fracture classification, reduction quality, blade position, BRQC, CRQC, bone quality, and the occurrence of mechanical complications were used in the statistical analysis. Results. A total of 127 patients were included in the full analysis, and mechanical complications were observed in 26 patients. The
Aims. To develop a core outcome set of measurements from postoperative radiographs that can be used to assess technical skill in performing dynamic hip screw (DHS) and hemiarthroplasty, and to validate these against Van der Vleuten’s criteria for effective assessment. Methods. A Delphi exercise was undertaken at a regional major trauma centre to identify candidate measurement items. The feasibility of taking these measurements was tested by two of the authors (HKJ, GTRP). Validity and reliability were examined using the radiographs of operations performed by orthopaedic resident participants (n = 28) of a multicentre randomized controlled educational trial (ISRCTN20431944). Trainees were divided into novice and intermediate groups, defined as having performed < ten or ≥ ten cases each for DHS and hemiarthroplasty at baseline. The procedure-based assessment (PBA) global rating score was assumed as the gold standard assessment for the purposes of concurrent validity. Intra- and inter-rater reliability testing were performed on a random subset of 25 cases. Results. In total, 327 DHS and 248 hemiarthroplasty procedures were performed by 28 postgraduate year (PGY) 3 to 5 orthopaedic trainees during the 2014 to 2015 surgical training year at nine NHS hospitals in the West Midlands, UK. Overall, 109 PBAs were completed for DHS and 80 for hemiarthroplasty. Expert consensus identified four ‘final product analysis’ (FPA) radiological parameters of technical success for DHS: tip-apex distance (TAD); lag screw position in the femoral head; flushness of the plate against the lateral femoral cortex; and eight-cortex hold of the plate screws. Three parameters were identified for hemiarthroplasty: leg length discrepancy; femoral stem alignment; and femoral offset. Face validity, content validity, and feasibility were excellent. For all measurements, performance was better in the intermediate compared with the novice group, and this was statistically significant for
Introduction. The vast majority of intertrochanteric fractures treated with cephalomedullary nails (CMN) will heal. Occasionally even though bony union occurs excessive lag screw sliding can cause persistent pain and soft tissue irritation and return to surgery for hardware removal. The purpose of this study was to evaluate if fracture stability, lag screw tip-apex distance (TAD), and quality of reduction have any impact excessive lag screw sliding and potential cutout. Methods. As part of our level one trauma center's institutional hip fracture registry, a retrospective analysis identified 199 intertrochanteric fractures fixed with CMN between 2009 and 2015 with follow up to union or a minimum of three months. The mean follow-up was 22 months (3 to 94 months). Mean patient age was 75 years (50 to 97 years) and 72% were women. Postoperative radiographs were used to measure the
Introduction: Hip fractures are a massive problem in an ageing population with 7–21 million predicted world-wide by 2025. The stabilization of intertrochanteric fractures reduces morbidity, mortality and allows mobilization. The treatment of these fractures has evolved over the past 50 years to the Sliding hip screw and plate, and intramedullary devices Current evidence suggests that the SHS systems are superior in stable fracture patterns and intramedullary devices are superior in unstable fracture patterns such as reverse oblique fractures or subtrochanteric fractures. Accurate implant positioning will prevent failure and the associated morbidity and mortality. The most frequent failure is due to cut out of the screw through the femoral head due to poor positioning. Cut out is directly correlated with tip apex distance (TAD). A
Awareness that minimising tip apex distance (TAD) when inserting a sliding hip screw reduces the risk of screw cut out is important for orthopaedic trainees. The advent of the Picture Archive and Communication System (PACS) has made the accurate measurement of
It is widely accepted that a tip apex distance of greater than 25mm is associated with dynamic hip screw (DHS) failure and cut-out. The aim was to devise an accurate and easy method for calculation of DHS tip apex distance (TAD) from intraoperative imaging using the tools available on Kodac Picture Archiving and Communications System. This method was applied to all patients treated with a DHS for intertrochanteric hip fracture during a six month period. Any subsequent radiographs were assessed for evidence of failure within 18 months. The
This multicentre audit assessed the total Tip Apex Distance (TAD) of sliding hip screws for intertrochanteric hip fractures in the 3 fracture hospitals in Northern Ireland (Ulster Hospital, Royal Victoria Hospital &
Altnagelvin Hospital). Patient demographics and anaesthetic information was also reviewed. A sample of 140 patients with adequate screening films (39 UHD, 50 RVH &
51 Altnagelvin) were selected. The
Intertrochanteric fractures are common, accounting for nearly 30% of all fracture related admissions. Some have suggested that these fractures should be treated in community hospitals so as not to tax the resources of Level One trauma centers. Since many factors predictive of fixation failure are related to technical aspects of the surgery, the purpose of this study was to compare radiographic parameters after fixation comparing trauma fellowship trained surgeons to non-fellowship trained community surgeons to see if these fractures can be treated successfully in either setting. Using our hospital system's trauma database, we identified 100 consecutive patients treated with cephalomedullary nails by traumatologists, and 100 consecutive patients treated by community surgeons. Quality of reduction, neck shaft angle (NSA), tip-to apex distance (TAD) were compared. The mean
A tip-apex distance (TAD) greater than 25 mm is a strong predictor of screw cut-out in patients with intertrochanteric femoral fracture treated with a dynamic hip screw (DHS). We aim to show you a simple and reliable way to check this. By calculating the sum of the distance from the tip of the screw to the apex of the femoral head on anteroposterior and lateral views the
Intra-operative Tip-Apex Distance (TAD) estimation optimises dynamic hip screw (DHS) placement during hip fracture fixation, reducing risk of cut-out. Thread-width of a standard DHS screw measures approximately 12.5 millimetres. We assessed the effect of introducing screw thread-width as an intra-operative distance reference to surgeons. The null hypothesis was that there were no differences between hip fracture fixation before and after this intervention. Primary outcome measure was
Purpose: Purpose of the study is to compare the changing Tip Apex Distance (TAD) and therefore the cut out development risk during fracture healing in two different types of implant. Materials and Methods: 166 patients with intertrochanteric femur fracture were operated with proximal femoral nail between the years 1999 and 2006 in our clinic. 117 patients with avaible radiological data were studied. Group I defined as PFN, had 90 patients. Median age was 74.2 (25–93) years, 44 female and 46 male. Grup II defined as PFN-A had 27 patients. Median age was 75 (33–88) years, 18 females, 9 males. The mean of following time of patients was 48 months (12–84 months). We measured in AP radiograph the tip-apex distance (TAD) both of early postop and fracture healing time. Results: In group I change in
Failure of cephalomedullary fixation for proximal femur fractures is an uncommon event associated with significant morbidity to the patient and cost to the healthcare system. This institution changed nailing system from the PFNA (DePuy Synthes) to InterTan (Smith and Nephew) in February 2020. To assess for non-inferiority, a retrospective review was performed on 247 patients treated for unstable proximal femur fractures (AO 31 A2; A3). Patients were identified through manual review of fluoroscopic images. Stable fracture patterns were excluded (AO 31 A1). Pre/post operative imaging, demographic data, operative time and ASA scores assessed. Internal/external imaging and national joint registry data were reviewed for follow up. No significant difference was found in overall failure rate of PFNA vs InterTan (4.84% vs 3.23%; p = 0.748). Overall, short nails were more likely to fail by cut-out than long nails (7.5% vs 1.2%; p = 0.015). Nails which failed by varus cut-out had a higher tip/apex distance (TAD) (26.2mm vs 17.0mm; p < 0.001). Of concern, varus cut-out occurred in two InterTan nails with
Subtrochanteric femoral fractures are a subset of hip fractures generally treated with cephalomedullary nail fixation\[1\]. Single lag screw devices are most commonly-used, but integrated dual screw constructs have become increasingly popular\[2,3\]. The aim of this study was to compare outcomes of fixation of subtrochanteric femoral fractures using a single lag screw (Gamma3 nail, GN) with a dual screw device (InterTAN nail, IN). The primary outcome was mechanical failure, defined as lag screw cut-out, back-out, nail breakage or peri-implant fracture. Consecutive adult patients (18yrs) with subtrochanteric femoral fracture treated in a single centre were retrospectively identified using electronic records. Patients that underwent surgical fixation using either a long GN (2010–2017) or IN (2017–2022) were included. Medical records and radiographs were reviewed to identify complications of fixation. Cox regression analysis was used to determine the risk of mechanical failure and secondary outcomes by implant design. Multivariable regression models were used to identify predictors of mechanical failure. The study included 622 patients, 354 in the GN group (median age 82yrs, 72% female) and 268 in the IN group (median age 82yrs, 69% female). The risk of any mechanical failure was increased two-fold in the GN group (HR 2.44 \[95%CI 1.13 to 5.26\]; _p=0.024_). Mechanical failure comprising screw cut-out (_p=0.032_), back-out (_p=0.032_) and nail breakage (_p=0.26_) was only observed in the GN group. Technical predictors of failure included varus >5° for cut-out (OR 19.98 \[2.06 to 193.88\]; _p=0.01_),
Background. Hip fractures cause significant morbidity and mortality, affecting 70,000 people in the UK each year. The dynamic hip screw (DHS) is used for the osteosynthesis of extracapsular neck of femur fractures, a procedure that requires complex psychomotor skills to achieve optimal lag screw positioning. The tip-apex distance (TAD) is a measure of the position of the lag screw from the apex of the femoral head, and is the most comprehensive predictor of cut-out (failure of the DHS construct). To develop these skills, trainees need exposure to the procedure, however with the European Working Time Directive, this is becoming harder to achieve. Simulation can be used as an adjunct to theatre learning, however it is limited. FluoroSim is a digital fluoroscopy simulator that can be used in conjunction with workshop bones to simulate the first step of the DHS procedure (guide-wire insertion) using image guidance. This study assessed the construct validity of FluoroSim. The null hypothesis stated that there would be no difference in the objective metrics recorded from FluoroSim between users with different exposure to the DHS procedure. Methods. This multicentre study recruited twenty-six orthopaedic doctors. They were categorised into three groups based on the number of DHS procedures they had completed as the primary surgeon (novice <10, intermediate 10≤x<40 and experienced ≥40). Twenty-six participants completed a single DHS guide-wire attempt into a workshop bone using FluoroSim. The
Introduction Intertrochanteric fractures are common and represent a major source of morbidity and mortality. As with all orthopaedic implants a DHS can fail. One of the most important predictors of failure has been shown to be the Tip-Apex Distance (TAD). An audit was carried to assess the following:. What was our rate of cut out and implant failure?. Where we achieving an acceptable screw position and