Ligament reconstruction following multi-ligamentous knee injuries involves graft fixation in bone tunnels using interference screws (IS) or cortical suspensory systems. Risks of IS fixation include graft laceration, cortical fractures, prominent hardware, and inability to adjust tensioning once secured. Closed loop
Acromioclavicular joint is an integral component of Shoulder Complex and common site of injury particularly for athletes involved in sports such as Football, Cricket, Rugby and Shotput. Acromioclavicular Injuries are often neglected and goes untreated especially in low demand patients. Classic surgical techniques are associated with high complication rates. This is a prospective study from 2015–2017 wherein 32 patients with Acute grade 3, 4, 5, 6 Acromioclavicular joint dislocations, were operated with Minimally Invasive Double Tunnel Anatomical Coraco-clavicular Ligament Reconstruction (DT-ACCLR) with Tightrope
Objectives. To compare the effect of femoral bone tunnel configuration on tendon-bone healing in an anterior cruciate ligament (ACL) reconstruction animal model. Methods. Anterior cruciate ligament reconstruction using the plantaris tendon as graft material was performed on both knees of 24 rabbits (48 knees) to mimic ACL reconstruction by two different
We evaluated the mechanical strength of two cortical suspension devices by reproducing clinical situation for ACL reconstruction. A most important factor affecting the displacement during cyclic load was the length of the tendon rather than the length of the device. A definite consensus for the optimal graft fixation technique to the femur in an anterior cruciate ligament (ACL) reconstruction has not been reached, although there have been several fixation techniques such as cortical suspension devices, transfixation devices, and interference screws. The purpose of this study was to evaluate the mechanical strength of two cortical suspension devices by reproducing actual clinical situation for ACL reconstruction in order to compare the TightRopeTM as a new adjustable-length loop device and the EndoButtonTM as a well-known fixed-length loop device under the consistent conditions.Summary Statement
Introduction
The optimal method of tibial fixation when using a hamstring tendon autograft in anterior cruciate ligament (ACL) reconstruction is unclear. This study aimed to compare the risk of revision ACL reconstruction between suspensory and interference devices on the tibial side. Prospective data on primary ACL reconstructions recorded in the New Zealand ACL Registry between April 2014 and December 2019 were analyzed. Only patients with a hamstring tendon autograft fixed with a suspensory device on the femoral side were included. The rate of revision ACL reconstruction was compared between suspensory and interference devices on the tibial side. Univariate Chi-Square test and multivariate Cox regression was performed to compute hazard ratios (HR) and 95% confidence intervals (CI) with adjustment for age, gender, time-to-surgery, activity at the time of injury, number of graft strands and graft diameter. 6145 cases were analyzed, of which 59.6% were fixed with a suspensory device on the tibial side (n = 3662), 17.6% fixed with an interference screw with a sheath (n = 1079) and 22.8% fixed with an interference screw without a sheath (n = 1404). When compared to suspensory devices (revision rate = 3.4%), a higher risk of revision was observed when using an interference screw with a sheath (revision rate = 6.2%, adjusted HR = 2.05, 95% CI 1.20 – 3.52, p = 0.009) and without a sheath (revision rate = 4.6%, adjusted HR = 1.81, 95% CI 1.02 – 3.23, p = 0.044). The number of graft strands and a graft diameter of ≥8 mm did not influence the risk of revision. When reconstructing the ACL with a hamstring tendon autograft, the use of an interference screw, with or without a sheath, on the tibial side has a higher risk of revision when compared to a suspensory device.
This prospective, randomized, controlled trial compares patient outcome after non-operative care versus open reduction and tunneled suspension device fixation (ORTSD) for grade III or IV acromioclavicular joint disruptions. Sixty patients aged between sixteen and thirty-five years with an acute grade III or IV AC joint disruption were randomized to receive ORTSD fixation or non-operative treatment. Functional assessment was conducted at six weeks, three months, six months, and one year using the Disabilities of the Arm, Shoulder and Hands (DASH), Oxford Shoulder Scores (OSS) and Short Form (SF-12). Reduction was evaluated using radiographs. Complications were recorded, and an economic evaluation performed. There was no significant difference in DASH or OSS at one year between non-operative and ORTSD groups (DASH score, 4.67 versus 5.63; OSS, 45.72 versus 45.63). Patients undergoing surgery had inferior DASH scores at 6 weeks (p<0.01). Five patients who failed non-operative management subsequently received surgery. Overall cost of treatment was significantly greater after ORTSD fixation (£796.22 vs £3359.73 (p<0.01)). ORTSD fixation confers no functional benefit over non-operative treatment at one year. While patients managed non-operatively generally recover faster, a significant group remain dissatisfied following non-operative treatment requiring delayed surgical reconstruction.
Aims. To evaluate graft healing of decellularized porcine superflexor tendon (pSFT) xenograft in an ovine anterior cruciate ligament (ACL) reconstruction model using two femoral fixation devices. Also, to determine if pSFT allows functional recovery of gait as compared with the preoperative measurements. Methods. A total of 12 sheep underwent unilateral single-bundle ACL reconstruction using pSFT. Two femoral fixation devices were investigated: Group 1 (n = 6) used cortical
Poor availability of allografts in South Africa has led to an increased use of synthetic augmentation to stabilize knee joints in the treatment of knee dislocations. This study aims to evaluate multiligament knee injuries treated with a posterior cruciate ligament internal brace. The study included patients with knee dislocations who were treated with a PCL internal brace. The internal brace involved the insertion of a synthetic suture tape, which was drilled into the femoral and tibial footprint. Chronic injuries were excluded. Patient-reported outcome scores (PROMs), range of motion, stress X-Rays, and MRI scans were reviewed to assess outcomes. Acceptable outcomes were defined as a Lysholm score of 84 or more, with grade II laxity in no more than one ligament and a range of motion from full extension to 90° or more. The study included eight patients, with a median age of 42, of which five were female. None of the patients had knee flexion less than 90° or an extension deficit of more than 20°. PROMs indicated acceptable outcomes (EQ5D, Tegner Lysholm). Stress radiographs showed less than 7mm (Grade I) of posterior translation laxity in all patients. Four patients underwent MRI scans 1–2 years after the initial surgery, which revealed healing of the PCL in all patients. However, increased signal in a continuous ligament suggested only partial healing in two patients. Tunnel widening of 200% and 250% was noted around the tibial and femoral PCL footprints, respectively. All patients demonstrated stable knees and acceptable PROMs. Tunnel widening was observed in all patients who had MRI scans. Factors such as
Introduction: After adopting a new low suspensory bio-absorbable femoral fixation technique for single bundle, four strand, hamstring Anterior Crutiate Ligament (ACL) in conjunction with a rapid rehabilitation program, we observed at routine follow up that there was no evidence of femoral tunnel widening, as often observed with conventional high
Introduction: The aim of this study was to compare two methods of femoral fixation for four strand Hamstring (4SH) primary ACL reconstruction: namely a recently introduced
The purpose of this study was to describe our experience of the Calaxo Osteoconductive interference screw (Smith &
Nephew) when used for both femoral and tibial graft fixation in Double Bundle ACL reconstruction. Since May 2006, all patients with an ACL deficient knee were reconstructed using the Double Bundle technique. All were followed prospectively and outcome data collected. Evidence of fixation failure was established subjectively by clinical examination (Lachman, Anterior Draw, Pivot Shift) and objectively via KT-1000 arthrometer. Following ethical approval, post-operative CT scans (immediate and 1 year) were performed on our first 10 patients allowing assessment of tunnel dimensions/fill. Thirty two patients (29 male, 3 female) with a mean age of 30 (range 18-46) were included. At last follow-up, no evidence of graft/fixation failure was found; KT-1000 mean side-side difference 1.4mm (range −3 to +6). All patients had a positive pivot shift preoperatively which was abolished postoperatively. One patient had a postoperative infection with no other complications reported. Radiologically the screws did not show complete resorption but areas of new bone were identified. We have shown satisfactory results with use of the Calaxo screw when used in Double Bundle Reconstruction. We have not had any cases of the adverse local soft tissue reaction, which has led to this screw being withdrawn from clinical use. Even when using a total of four screws in each knee. A previous study published by Seibold (2007) has shown tunnel widening and communication when
Introduction: The purpose of this study was to describe our experience of the Calaxo Osteoconductive interference screw (Smith &
Nephew) when used for both femoral and tibial graft fixation in Double Bundle ACL reconstruction. Methods: Since May 2006, all patients with an ACL deficient knee were reconstructed using the Double Bundle technique. All were followed prospectively and outcome data collected. Evidence of fixation failure was established subjectively by clinical examination (Lachman, Anterior Draw, Pivot Shift) and objectively via KT-1000 arthrometer. Following ethical approval, post-operative CT scans (immediate and 1 year) were performed on our first 10 patients allowing assessment of tunnel dimensions/fill. Results: Thirty two patients (29 male, 3 female) with a mean age of 30 (range 18–46) were included. At last follow-up, no evidence of graft/fixation failure was found; KT-1000 mean side-side difference 1.4mm (range −3 to +6). All patients had a positive pivot shift preoperatively which was abolished postoperatively. One patient had a postoperative infection with no other complications reported. Radiologically the screws did not show complete resorption but areas of new bone were identified. Discussion: We have shown satisfactory results with use of the Calaxo screw when used in Double Bundle Reconstruction. We have not had any cases of the adverse local soft tissue reaction, which has led to this screw being withdrawn from clinical use. Even when using a total of four screws in each knee. A previous study published by Seibold (2007) has shown tunnel widening and communication when
Cite this article:
MRI has been suggested as an objective method of assessing anterior crucate ligament (ACL) graft “ligamentization” after reconstruction. It has been proposed that the MRI appearances could be used as an indicator of graft maturity and used as part of a return-to-sport assessment. The aim of this study was to evaluate the correlation between MRI graft signal and postoperative functional scores, anterior knee laxity, and patient age at operation. A consecutive cohort of 149 patients who had undergone semitendinosus autograft ACL reconstruction, using femoral and tibial adjustable loop fixations, were evaluated retrospectively postoperatively at two years. All underwent MRI analysis of the ACL graft, performed using signal-to-noise quotient (SNQ) and the Howell score. Functional outcome scores (Lysholm, Tegner, International Knee Documentation Committee (IKDC) subjective, and IKDC objective) were obtained and all patients underwent instrumented side-to-side anterior laxity differential laxity testing.Aims
Methods
The August 2012 Knee Roundup360 looks at: meniscal defects and a polyurethane scaffold; which is best between a single or double bundle; OA of the knee; how to resolve anterior knee pain; whether yoga can be bad for your menisci; metal ions in the serum; whether ACI is any good; the ACL; whether hyaluronic acid delays collagen degradation; and hyaluronan and patellar tendinopathy.