Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 238 - 238
1 Jun 2012
Tamaki T
Full Access

Background. We have often experienced a change of the tone of the hammering sound during the press-fit implantation of cementless acetabular components in total hip arthroplasty (THA). The tone of the impact sound before the press-fit of acetabular components seems to differ from the tone after the press-fit. This change of tone may depend on the accuracy of the fit of the acetabular component, or it may simply be a subjective perception. The aim of this study is to evaluate the impact sounds in the press-fit implantation of cementless acetabular components. Methods. The hammering sounds in press-fit implantation of acetabular components were studied intraoperatively in 22 patients (28 hips) who underwent primary THA for treatment of advanced osteoarthritis. All operations were performed via the direct anterior approach in a supine position. The hemispherical titanium-alloy acetabular component (TriAD; stryker) was implanted in all patients. A sound level meter (NA-28; RION) was used to record and analyze the sounds. The hammering sounds of the first three hits and last three hits were recorded as the “before press-fit” and “after press-fit” sound samples, respectively. A frequency analysis was then performed at the point of peak sound pressure in each sample. Results. The dominant frequency of the impact sounds was equal to or lower than 1 kHz in 20% of the before press-fit samples and 76% of the after press-fit samples, and equal to or higher than 4 kHz in 69% of the before press-fit samples and 21% of the after press-fit samples. The frequency of the impact sounds changed significantly (p<0.01) during the press-fit implantation. Conclusion. The frequency of the impact sound changed significantly during the press-fit implantation of cementless acetabular components. We conclude that an intraoperative evaluation of the impact sound might help to improve accuracy when implanting the acetabular component


Bone & Joint Open
Vol. 5, Issue 3 | Pages 154 - 161
1 Mar 2024
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims

It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA.

Methods

In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 154 - 161
28 Mar 2023
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims

It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA.

Methods

In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound.