Introduction: There has been an introduction of short femoral stems with the aim of conserving bone. We present the short term results of short metaphyseal cement-less stem(Proxima. ®. , Depuy). Material and methods: 25 patients in age group (25–40yrs), 15 males,10 females were implanted with a
25 patients in age group (25–40yrs), 15 males, 10 females were implanted with a
Interestingly, recent studies have shown promising outcomes in elderly. To the best of our knowledge there are no reports available assessing sequential bone remodelling around DCPD (dicalcium phosphate dehydrate) coated
Purpose. Traditional total knee arthoplasty techniques have involved implantation of diaphyseal stems to aid in fixation expecially when using constrained polyethylene inserts. While the debate over cemented vs uncemented stems continues, the actual use of stems is considered routine. The authors' experience with cemented stemmed knee revisions in older patients with osteoporotic bone has been favorable. Our younger patients with press-fit stems from varying manufacturers have been plagued with a relatively high incidence of component loosening and stem tip pain in the tibia and occasionally thigh. We report the early results of the first 20 total knee revisions using press-fit metaphyseal filling sleeved stemless implants with constrained bearings. Methods. Twenty three patients with failed primary or revision total knees were assigned to receive stemless sleeved revision knee designs using the DePuy MBT/TC3 system. Reasons for revision included loosening, implant fracture, stiffness, instability, and stem pain. Twenty patients (ages ranging from 42–73) were successfully reconstructed without stems. Six knees with significant uncontained cavitary defects were included. Three patients with unexpectedly osteoporotic metaphyseal bone were revised with cemented stemmed implants and excluded. All cases used cement for initial fixation on the cut bone surface and fully constrained mobile bearing inserts. Results. Follow up ranged from six months to three years. All patients had radiographic evidence of well fixed stable implants on most recent examination. All four cases of revision for “end of stem pain” had complete resolution of symptoms within two weeks of revision surgery. Long leg anterior posterior mechanical alignment x-rays measured within two degrees of neutral in all cases. Knee Society Scores improved an average of 34 points. Clinical results for revision for stiffness had the lowest final scores post operatively. Conclusion. Stemmed total knee arthroplasty revision implants with or without cement are considered the standard for most revision reconstructions. Recently, primary total hip replacements using newer
Aims: determine risk factors associated with component loosening so that measures can be implemented to improve component durability. Methods: The þrst 300 patients with Wright Medical Conserve Plusª metal-on-metal hip resurfacings were analyzed radiographically for radiolucencies and failed components were analyzed histologically after the components were sectioned. The group average age was 48 years, 75% were male, and most were operated for OA. At an average of 3 years, 7 hips required revision for femoral loosening, none for acetabular loosening. These included 4 of the þrst 100 cases, 1 in the 2nd 100, 2 in the 3rd 100. Radiographic lucencies were found in 9 of the 1st 100, and 3 in each of the of the 2nd and third 100. Results: The etiology of femoral loosening was found to be multifac-torial and risk factors included: substandard bone preparation, presence of large cysts or bone defects, cement technique, and patient activity. The
The purpose of the present study was to identify risk factors for femoral loosening and neck fracture for Conserve+ metal-on-metal hybrid surface atrhroplasty. The first 500 hips (of over 700 implanted by the senior author) in 436 patients were reviewed. Mean age was 48.6 with 74% of males patients. 16 hips were converted to THR secondary to aseptic failure on the femoral side (11 femoral component loosenings and 5 femoral neck fractures). 14 hips showed radiolucencies around the