Bone & Joint Open
Vol. 5, Issue 10 | Pages 898 - 903
17 Oct 2024
Mazaheri S Poorolajal J Mazaheri A

Aims. The sensitivity and specificity of electrodiagnostic parameters in diagnosing carpal tunnel syndrome (CTS) have been reported differently, and this study aims to address this gap. Methods. This case-control study was conducted on 57 cases with CTS and 58 controls without complaints, such as pain or paresthesia on the median nerve. The main assessed electrodiagnostic parameters were terminal latency index (TLI), residual latency (RL), median ulnar F-wave latency difference (FdifMU), and median sensory latency-ulnar motor latency difference (MSUMLD). Results. The mean age in cases and controls were 50.7 years (SD 9.9) and 47.9 years (SD 12.1), respectively. The CTS severity was mild in 20 patients (34.4%), moderate in 19 patients (32.8%), and severe in 19 patients (32.8%). The sensitivity and specificity of the electrodiagnostic parameters in diagnosing CTS were as follows: TLI 75.4% and 87.8%; RL 85.9% and 82.5%; FdifMU 87.9% and 82.9%; and MSUMLD 94.8% and 60.0%, respectively. Conclusion. Our findings indicated that electrodiagnostic parameters are significantly associated with the clinical manifestation of CTS, and are associated with high diagnostic accuracy in CTS diagnosis. However, further studies are required to highlight the role of electrodiagnostic parameters and their combination in CTS detection. Cite this article: Bone Jt Open 2024;5(10):898–903


Bone & Joint Open
Vol. 2, Issue 10 | Pages 796 - 805
1 Oct 2021
Plumarom Y Wilkinson BG Willey MC An Q Marsh L Karam MD

Aims. The modified Radiological Union Scale for Tibia (mRUST) fractures score was developed in order to assess progress to union and define a numerical assessment of fracture healing of metadiaphyseal fractures. This score has been shown to be valuable in predicting radiological union; however, there is no information on the sensitivity, specificity, and accuracy of this index for various cut-off scores. The aim of this study is to evaluate sensitivity, specificity, accuracy, and cut-off points of the mRUST score for the diagnosis of metadiaphyseal fractures healing. Methods. A cohort of 146 distal femur fractures were retrospectively identified at our institution. After excluding AO/OTA type B fractures, nonunions, follow-up less than 12 weeks, and patients aged less than 16 years, 104 sets of radiographs were included for analysis. Anteroposterior and lateral femur radiographs at six weeks, 12 weeks, 24 weeks, and final follow-up were separately scored by three surgeons using the mRUST score. The sensitivity and specificity of mean mRUST score were calculated using clinical and further radiological findings as a gold standard for ultimate fracture healing. A receiver operating characteristic curve was also performed to determine the cut-off points at each time point. Results. The mean mRUST score of ten at 24 weeks revealed a 91.9% sensitivity, 100% specificity, and 92.6% accuracy of predicting ultimate fracture healing. A cut-off point of 13 points revealed 41.9% sensitivity, 100% specificity, and 46.9% accuracy at the same time point. Conclusion. The mRUST score of ten points at 24 weeks can be used as a viable screening method with the highest sensitivity, specificity, and accuracy for healing of metadiaphyseal femur fractures. However, the cut-off point of 13 increases the specificity to 100%, but decreases sensitivity. Furthermore, the mRUST score should not be used at six weeks, as results show an inability to accurately predict eventual fracture healing at this time point. Cite this article: Bone Jt Open 2021;2(10):796–805


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 72 - 72
22 Nov 2024
Zouitni A van Oldenrijk J Bos K Croughs PD Yusuf E Veltman W
Full Access

Aim. Periprosthetic joint infection (PJI) is a serious complication after joint arthroplasty. Diagnosing PJI can be challenging as preoperative screening and conventional cultures may be inconclusive. Sonication fluid culturing stands out as a valuable adjunct technique to improve microbiological PJI diagnosis. This study aims to determine the clinical relevance of routinely using sonication for all septic and aseptic revisions. Method. All patients who underwent (partial) hip or knee revision arthroplasty for all causes between 2012 and 2021 at our institution were retrospectively reviewed. Based on the European Bone and Joint Society PJI criteria, we categorized them into three groups: infection confirmed, infection likely, and infection unlikely. We analyzed the clinical, laboratory, and radiological screening that could confirm or refute suspicion of PJI. We analyzed microbiology cultures and the most frequently detected microorganisms. Sensitivity and specificity were calculated for synovial fluid cultures (preoperative), tissue cultures, and sonication fluid cultures. We determined the clinical relevance of sonication as the percentage of patients for whom sonication confirmed (microbiological) PJI diagnosis. Results. 429 patients who underwent (partial) revision of hip (246 patients) or knee (183 patients) arthroplasty were included. Sensitivity and specificity were 69% and 99% for preoperative synovial fluid cultures, 76% and 92% for intraoperative tissue cultures, and 80% and 89% for sonication fluid cultures, respectively. Sonication fluid cultures improved tissue culture sensitivity and specificity to 83% and 99%, respectively. In 12 (11%) out of 110 PJIs, sonication fluid cultures were decisive for confirming the causative pathogen. This was applicable to acute and chronic infections. In 29 (9%) out of 319 aseptic cases, a negative sonication fluid culture could confirm contamination of tissue cultures. Conclusions. Routine sonication fluid cultures enhanced the sensitivity and specificity of PJI diagnostics. In 11% of PJI cases, causative pathogens were confirmed by sonication fluid culture results. Routine sonication may be helpful in confirming contamination of synovial fluid cultures and tissue cultures. Routine sonication fluid culture should be performed in all revision arthroplasties


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 73 - 73
22 Nov 2024
Erbeznik A Smrdel KS Kišek TC Cvitković-Špik V Triglav T Vodicar PM
Full Access

Aim. The aim of this study was to develop an in-house multiplex PCR real-time assay on the LightCycler 480 system (Roche, Basel, Switzerland) with the aim of rapid detection of common pathogens in prosthetic joint infections (PJI), followed by validation on clinical samples (sonication fluid and tissue biopsies) routinely collected for PJI diagnosis. Methods. Using the PrimerQuest and CLC WorkBench tool, we designed six primer sets with specific fluorescently labelled TaqMan probes for the nuc gene in different Staphylococcus species (S. aureus, S. epidermidis, S. capitis, S. lugdunensis, S. hominis, S. haemolyticus). In addition, primers previously developed by Renz et al. (2022) for C. acnes were integrated into our assay with internal control of isolation, leading to the development of specific mPCR assay with seven included targets. Analytical sensitivity and specificity were evaluated using reference bacterial strains. To determine the assay's limit of detection (LOD), we conducted serial dilutions of eluates containing known concentrations of bacterial DNA copies/µl. The overall LOD in spiked clinical samples, including sample preparation and DNA isolation on MagnaPure24, was measured through 10-fold serial dilutions (from 10. 9. to 10. -1. CFU/ml) including additional dilutions of 5000, 500, 50 and 5 CFU/ml. Results. The results with LOD in serial dilutions of eluates and spiked clinical samples, together with analytical sensitivity and specificity, are shown in Table 1. Conclusion. The mPCR assay showed excellent analytical sensitivity and specificity, but with considerably lower LOD after sample preparation and further DNA isolation in spiked clinical samples. Although still promising in diagnostics of acute infections, the use of mPCR could be challenging in chronic, low-grade infections with lower microbial burden. Nevertheless, PCR offers significant advantages in terms of speed and can shorten the time to result, especially for C. acnes infections. Additionally, it represents a promising complementary approach in patients with suspected PJI on antibiotic therapy with negative culture results. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_18 | Pages 60 - 60
14 Nov 2024
Asgari A Shaker F Fallahy MTP Soleimani M Shafiei SH Fallah Y
Full Access

Introduction. Shoulder arthroplasty (SA) has been performed with different types of implants, each requiring different replacement systems. However, data on previously utilized implant types are not always available before revision surgery, which is paramount to determining the appropriate equipment and procedure. Therefore, this meta-analysis aimed to evaluate the accuracy of the AI models in classifying SA implant types. Methods. This systematic review was conducted in Pubmed, Embase, SCOPUS, and Web of Science from inception to December 2023, according to PRISMA guidelines. Peer-reviewed research evaluating the accuracy of AI-based tools on upper-limb X-rays for recognizing and categorizing SA implants was included. In addition to the overall meta-analysis, subgroup analysis was performed according to the type of AI model applied (CNN (Convolutional neural network), non-CNN, or Combination of both) and the similarity of utilized datasets between studies. Results. 13 articles were eligible for inclusion in this meta-analysis (including 138 different tests assessing models’ efficacy). Our meta-analysis demonstrated an overall sensitivity and specificity of 0.891 (95% CI:0.866-0.912) and 0.549 (95% CI:0.532,0.566) for classifying implants in SA, respectively. The results of our subgroup analyses were as follows: CNN-subgroup: a sensitivity of 0.898 (95% CI:0.873-0.919) and a specificity of 0.554 (95% CI:0.537,0.570), Non-CNN subgroup: a sensitivity of 0.809 (95% CI:0.665-0.900) and specificity of 0.522 (95% CI:0.440,0.603), combined subgroup: a sensitivity of 0.891 (95% CI:0.752-0.957) and a specificity of 0.547 (95% CI:0.463,0.629). Studies using the same dataset demonstrated an overall sensitivity and specificity of 0.881 (95% CI:0.856-0.903) and 0.542 (95% CI:0.53,0.554), respectively. Studies that used other datasets showed an overall sensitivity and specificity of 0.995 (95% CI:969,0.999) and 0.678 (95% CI:0.234, 0.936), respectively. Conclusion. AI-based classification of shoulder implant types can be considered a sensitive method. Our study showed the potential role of using CNN-based models and different datasets to enhance accuracy, which could be investigated in future studies


Bone & Joint Research
Vol. 11, Issue 6 | Pages 398 - 408
22 Jun 2022
Xu T Zeng Y Yang X Liu G Lv T Yang H Jiang F Chen Y

Aims. We aimed to evaluate the utility of . 68. Ga-citrate positron emission tomography (PET)/CT in the differentiation of periprosthetic joint infection (PJI) and aseptic loosening (AL), and compare it with . 99m. Tc-methylene bisphosphonates (. 99m. Tc-MDP) bone scan. Methods. We studied 39 patients with suspected PJI or AL. These patients underwent . 68. Ga-citrate PET/CT, . 99m. Tc-MDP three-phase bone scan and single-photon emission CT (SPECT)/CT. PET/CT was performed at ten minutes and 60 minutes after injection, respectively. Images were evaluated by three nuclear medicine doctors based on: 1) visual analysis of the three methods based on tracer uptake model, and PET images attenuation-corrected with CT and those not attenuation-corrected with CT were analyzed, respectively; and 2) semi-quantitative analysis of PET/CT: maximum standardized uptake value (SUVmax) of lesions, SUVmax of the lesion/SUVmean of the normal bone, and SUVmax of the lesion/SUVmean of the normal muscle. The final diagnosis was based on the clinical and intraoperative findings, and histopathological and microbiological examinations. Results. Overall, 23 and 16 patients were diagnosed with PJI and AL, respectively. The sensitivity and specificity of three-phase bone scan and SPECT/CT were 100% and 62.5%, 82.6%, and 100%, respectively. Attenuation correction (AC) at 60 minutes and non-AC at 60 minutes of PET/CT had the same highest sensitivity and specificity (91.3% and 100%), and AC at 60 minutes combined with SPECT/CT could improve the diagnostic efficiency (sensitivity = 95.7%). Diagnostic efficacy of the SUVmax was low (area under the curve (AUC) of ten minutes and 60 minutes was 0.814 and 0.806, respectively), and SUVmax of the lesion/SUVmean of the normal bone at 60 minutes was the best semi-quantitative parameter (AUC = 0.969). Conclusion. 68. Ga-citrate showed the potential to differentiate PJI from AL, and visual analysis based on uptake pattern of tracer was reliable. The visual analysis method of AC at 60 minutes, combined with . 99m. Tc-MDP SPECT/CT, could improve the sensitivity from 91.3% to 95.7%. In addition, a major limitation of our study was that it had a limited sample size, and more detailed studies with a larger sample size are warranted. Cite this article: Bone Joint Res 2022;11(6):398–408


Bone & Joint Open
Vol. 4, Issue 11 | Pages 881 - 888
21 Nov 2023
Denyer S Eikani C Sheth M Schmitt D Brown N

Aims. The diagnosis of periprosthetic joint infection (PJI) can be challenging as the symptoms are similar to other conditions, and the markers used for diagnosis have limited sensitivity and specificity. Recent research has suggested using blood cell ratios, such as platelet-to-volume ratio (PVR) and platelet-to-lymphocyte ratio (PLR), to improve diagnostic accuracy. The aim of the study was to further validate the effectiveness of PVR and PLR in diagnosing PJI. Methods. A retrospective review was conducted to assess the accuracy of different marker combinations for diagnosing chronic PJI. A total of 573 patients were included in the study, of which 124 knees and 122 hips had a diagnosis of chronic PJI. Complete blood count and synovial fluid analysis were collected. Recently published blood cell ratio cut-off points were applied to receiver operating characteristic curves for all markers and combinations. The area under the curve (AUC), sensitivity, specificity, and positive and negative predictive values were calculated. Results. The results of the analysis showed that the combination of ESR, CRP, synovial white blood cell count (Syn. WBC), and polymorphonuclear neutrophil percentage (PMN%) with PVR had the highest AUC of 0.99 for knees, with sensitivity of 97.73% and specificity of 100%. Similarly, for hips, this combination had an AUC of 0.98, sensitivity of 96.15%, and specificity of 100.00%. Conclusion. This study supports the use of PVR calculated from readily available complete blood counts, combined with established markers, to improve the accuracy in diagnosing chronic PJI in both total hip and knee arthroplasties. Cite this article: Bone Jt Open 2023;4(11):881–888


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 41 - 41
22 Nov 2024
Copier B Visser D van Oldenrijk J Bos K Veltman W
Full Access

Aim. Periprosthetic joint infection (PJI) is a devasting complication after total hip arthroplasty. Joint aspiration and preoperative biopsy can be helpful diagnostics for PJI. The aim of this study is to evaluate the diagnostic value of preoperative biopsies after inconclusive or dry tap aspiration of the hip in patients undergoing revision hip arthroplasty. Secondarily we will evaluate the diagnostic value of synovial fluid aspiration cultures and peroperative tissue cultures for diagnosing or ruling out PJI. Methods. Patients who underwent diagnostic aspiration and subsequent preoperative biopsy and/or revision surgery between January 2015 and January 2024 were included in the study. Synovial fluid aspirations and tissue samples obtained from biopsy and revision surgery were interpreted using the European Bone and Joint Infection Society criteria for PJI and in close consultation with the microbiologist. Results. 207 Patients were included with 231 synovial fluid aspirations. Sensitivity and specificity of synovial fluid aspiration cultures were 76% and 98%. In 62 patients tissue biopsies were performed, of which 40 after a dry tap. The tissue biopsies after a dry tap aspiration had a sensitivity of 50.0% and a specificity of 95.8%. In 21% tissue biopsies led to the confirmation of PJI in patient with a high suspicion of PJI after dry tap aspiration. In patients with an inconclusive synovial fluid aspiration result the addition of tissue biopsies led to a change in treatment in 14%. In 212 cases revision surgery was performed, intraoperative tissue cultures had a sensitivity and specificity of 83.3% and 99.3%. Conclusions. Diagnosing PJI can be troublesome, especially if synovial fluid aspiration provides a dry tap. Tissue biopsy cultures in patients with a high suspicion of PJI after dry tap aspiration is a feasible way to confirm PJI, in 21% of patients PJI could be confirmed after dry tap aspiration. Ruling out PJI by means of a biopsy after a dry tap aspiration is less successful due to its low sensitivity. Tissue biopsies after an inconclusive aspiration leads to clinically important treatment changes


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 80 - 80
1 Oct 2022
Morovic P Karbysheva S Meller S Kirschbaum S Perka C Conen A Trampuz A
Full Access

Aim. Synovial fluid D-lactate may be useful for diagnosing septic arthritis (SA) as this biomarker is almost exclusively produced by bacteria. We evaluated the performance of synovial fluid D-lactate and determined its optimal cut-off value for diagnosing SA. Method. Consecutive patients with suspicion of septic arthritis were prospectively included. They underwent joint aspiration and synovial fluid was collected for culture, leukocyte count and D-lactate concentration (by spectrophotometry). Youden's J statistic was used for determining optimal D-lactate cut-off value on the receiver operating characteristic (ROC) curve by maximizing sensitivity and specificity. Results. A total of 155 patients were included. Using institutional criteria, 21 patients (14%) were diagnosed with SA and 134 (86%) patients with aseptic arthropathy, out of which 43 (27%) had osteoarthrosis, 80 (52%) had rheumatic arthropathy and 11 (7%) reactive arthritis. The optimal cut-off of synovial fluid D-lactate to differentiate SA from aseptic cases was 0,035 mmol/l. Synovial fluid D-lactate had a sensitivity 90% (95% CI: 70–99%) and specificity 87% (95% CI: 80–92%) compared to leukocyte count with sensitivity 81% (95% CI: 60–95%) and specificity 83% (95% CI: 76–90%). Culture was positive in only 17 (80%) out of 21 patients with SA. Conclusions. The synovial fluid D-lactate showed high sensitivity and specificity for diagnosis of SA which was higher than the current gold standard of diagnosis (culture and leukocyte count). The high sensitivity makes this biomarker useful as a point-of-care screening test for SA


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 20 - 20
1 Dec 2021
Schwarze J Theil C Gosheger G Lampe L Schneider KN Ackmann T Moellenbeck B Schmidt-Braekliing T Puetzler J
Full Access

Aim. Diagnosis and isolation of a causative organism is imperative for successful treatment of periprosthetic joint infections (PJI). While there are several diagnostic algorithms using microbiology, serum and synovial markers, the preoperative diagnosis of a low-grade infection remains a challenge, particularly in patients with unsuccessful aspiration. An incisional biopsy may be used in these cases as additional diagnostic tool. In this retrospective study we evaluated microbiological findings, sensitivity, and specificity of open synovial biopsies in cases of inconclusive preoperative diagnostics. Methods. In a retrospective databank analysis (2010–2018), we identified 80 TKAs that underwent an open biopsy because of inconclusive results after applying the CDC Criteria (2010) or the MSIS (2011–2018) for PJI. Infection makers in the serum (C-reactive protein [CRP], leucocytes count and interleukin-6 [IL-6]) and in the synovial aspirate (leucocyte count, percentage of neutrophiles) prior to the biopsy were analyzed. All biopsies were performed by suprapatellar mini-arthrotomy. If a subsequent revision surgery was performed, the isolated organisms in the open biopsy were compared to the results in the revision surgery and sensitivity and specificity were calculated. Serum markers were checked for correlation with a positive result in the open biopsy using Cramer-V and Chi. 2. -Test. Results. A positive result in the open biopsy occurred in 32 cases (40%) while 48 cases (60%) showed no growth of microorganisms. A preoperative elevated serum CRP (≥1mg/dl) showed a significant correlation for a positive biopsy (p=0.04). The odds ratio for a positive biopsy was 2.57 (95% CI 1.02–6.46) with elevated serum CRP. A revision surgery of the TKA with additional tissue sampling was performed in 27 (84%) cases with a positive biopsy and in 32 (67%) cases with a negative biopsy. The intraoperative tissue samples from the revision surgery showed microbial growth in only 52% of cases that were believed to be culture positive from the biopsy results, while positive cultures occurred in 41% of the cases with an initially negative biopsy. Patients with ≥ two cultures of the same microorganism in the biopsy presented a positive result in 73% of their revision surgeries. The open biopsy showed a sensitivity of 48% with a specificity of 62% in our collective if revision surgery was performed. Conclusion. Open biopsy may be considered with inconclusive preoperative serum and synovial fluid diagnostics for PJI, but sensitivity and specificity were rather low in this special collective. Further studies with bigger collectives should be performed to determine potential markers with a higher sensitivity


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_15 | Pages 18 - 18
1 Dec 2021
Warren J Anis H Bowers K Villa J Pannu T Klika AK Piuzzi N Colon-Franco J Higuera-Rueda C
Full Access

Aim. Several options to standardize the definition of periprosthetic joint infection (PJI) have been created including the 2013 Musculoskeletal Infection Society (MSIS), 2018 Intentional Consensus Meeting (ICM), and the 2019 proposed European Bone and Joint Infection Society (EBJIS) criteria. Synovial fluid biomarkers have been investigated in an effort to simplify and improve the diagnosis of PJI. The aim of this study was to test the sensitivity, specificity, positive, and negative predicted values (PPV and NPV, respectively) of a calprotectin point of care (POC) test for diagnosing PJI in revision total knee arthroplasty (TKA) patients comparing different sets of criteria (2013 MSIS, 2018 ICM, and 2019 EBJIS criteria) used to define patients as with or without infection. Method. From October 2018 to January 2020 and under IRB approval 123 intraoperative samples of synovial fluid were prospectively collected at two academic hospitals in the same institution from revision TKA patients. All patients underwent standard clinical and laboratory evaluation for PJI at our institution, allowing for categorization using the 3 criteria. Patients were adjudicated by 2 blinded and independent reviewers for the 3 sets of criteria. The 3 criteria agreed 91.8% of the time. Four likely cases by the 2019 proposed EBJIS were considered unlikely and 1 inconclusive case by the 2018 ICM was considered not infected for the purposes of analysis. Calprotectin POC testing followed manufacturer's instructions using a threshold of >50 mg/L to indicate PJI. Sensitivities, specificities, PPV, NPV, and areas under the curve (AUC) were calculated for the 3 sets of criteria. Results. Using 2013 MSIS criteria the calprotectin POC test demonstrated a sensitivity, specificity, PPV, NPV AUC of 98.1%, 95.7%, 94.5%, 98.5%, and 0.969, respectively. Using 2018 ICM the POC test demonstrated a sensitivity, specificity, PPV, NPV and (AUC) of 98.2%, 98.5%, 98.2%, 98.5%, and 0.984, respectively. Using the 2019 proposed EBJIS criteria the POC test demonstrated a sensitivity, specificity, PPV, NPV and area under the curve (AUC) of 93.2%, 100.0%, 100.0%, 94.2%, and 0.966, respectively. Conclusions. The calprotectin lateral flow POC test has an excellent sensitivity and specificity regardless of the set of criteria used to define PJI. These results are promising and suggest that the calprotectin lateral flow test may be used as a rule out test in a cost-conscious health care model or when conventional diagnostic tools may not be available. Further investigations of the calprotectin PCO test must be completed to validate these results


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 67 - 67
24 Nov 2023
Gardete-Hartmann S Simon S Frank BJ Sebastian S Loew M Sommer I Hofstaetter J
Full Access

Aim. Synovial calprotectin point-of-care test (POC) has shown promising clinical value in diagnosing periprosthetic joint infections (PJIs). However, limited data are available in unclear cases. Moreover, cut-off values for calprotectin lateral flow assay (LFA) and enzyme-linked immunosorbent assay (ELISA) need to be adapted. The aim of this study was to evaluate the performance of an upgraded and more sensitive version of a synovial calprotectin LFA along with ELISA immunoassay in patients with septic, aseptic, and unclear cases. Methods. Overall, 206 prospectively collected periprosthetic synovial fluid samples from 169 patients (106f/63m; 38 hip/131 knee) who underwent revision surgeries were retrospectively evaluated for calprotectin concentration. The following groups were analyzed: unexpected negative cultures (UNC; 32/206), unexpected positive cultures (UPC; 28/206), and unclear cases (65/206) with conflicting clinical results. In addition, we added a true aseptic (40/206), and true septic (41/206) control groups according to the international consensus meeting (ICM) 2018 PJI classification. Calprotectin concentration was determined by a rapid quantitative LFA (n=206) (Lyfstone®, Norway), and compared to calprotectin ELISA immunoassay (171/206). For the determination of a new calprotectin cut-off value, analysis of the area under the curve (AUC) followed by Youden's J statistic were performed using the calproctectin values from clear septic and aseptic cases. Sensitivity and specificity for calprotectin were calculated. All statistical analyses were performed using IBM-SPSS® version 25 (Armonk, NY, USA). Results. An absolute calprotectin value of 43 mg/ml, and 40.15 mg/ml was determined to be the optimal cut-off for PJI diagnosis using the new version of the LFA and ELISA, respectively. With this cut-off, the sensitivity and specificity of synovial calprotectin concentration for PJI were 88.1% (95% CI 77.8 to 94.7) and 76.6% (95% CI 61.9 to 87.7) for LFA, and 97.06% (95% CI 89.8 to 99.64) and 93.6% (95% CI 82.5 to 98.66) for ELISA, respectively. Of the evaluated groups, UNC 30/32 (93.8%) vs 26/27 (96.3%), UPC 6/28 (21.4%) vs 4/21 (19%), and unclear samples 45/65 (69.2%) vs 30/56 (53.6%) displayed a high likelihood of infection by using LFA, and ELISA, respectively. Conclusion. The upgraded version of the calprotectin quantitative LFA with a new suggested cut-off for infected samples showed additional clinical value in identifying cases at high risk of infection in unclear PJI revisions. Additionally, calprotectin ELISA immunoassay had a better performance than LFA. Further large sample-size validation studies are warranted


Bone & Joint Research
Vol. 12, Issue 9 | Pages 590 - 597
20 Sep 2023
Uemura K Otake Y Takashima K Hamada H Imagama T Takao M Sakai T Sato Y Okada S Sugano N

Aims. This study aimed to develop and validate a fully automated system that quantifies proximal femoral bone mineral density (BMD) from CT images. Methods. The study analyzed 978 pairs of hip CT and dual-energy X-ray absorptiometry (DXA) measurements of the proximal femur (DXA-BMD) collected from three institutions. From the CT images, the femur and a calibration phantom were automatically segmented using previously trained deep-learning models. The Hounsfield units of each voxel were converted into density (mg/cm. 3. ). Then, a deep-learning model trained by manual landmark selection of 315 cases was developed to select the landmarks at the proximal femur to rotate the CT volume to the neutral position. Finally, the CT volume of the femur was projected onto the coronal plane, and the areal BMD of the proximal femur (CT-aBMD) was quantified. CT-aBMD correlated to DXA-BMD, and a receiver operating characteristic (ROC) analysis quantified the accuracy in diagnosing osteoporosis. Results. CT-aBMD was successfully measured in 976/978 hips (99.8%). A significant correlation was found between CT-aBMD and DXA-BMD (r = 0.941; p < 0.001). In the ROC analysis, the area under the curve to diagnose osteoporosis was 0.976. The diagnostic sensitivity and specificity were 88.9% and 96%, respectively, with the cutoff set at 0.625 g/cm. 2. . Conclusion. Accurate DXA-BMD measurements and diagnosis of osteoporosis were performed from CT images using the system developed herein. As the models are open-source, clinicians can use the proposed system to screen osteoporosis and determine the surgical strategy for hip surgery. Cite this article: Bone Joint Res 2023;12(9):590–597


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 71 - 71
22 Nov 2024
Cobra H Mozella A Leal AC
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the most frequent and devastating complications of total knee arthroplasty (TKA). Accurate diagnosis and proper treatment are essential to prevent functional loss and progression to systemic infection. However, the correct diagnosis of PJI is still a challenge since there is no accurate diagnostic method and the existing diagnostic criteria are based on serological, histological and microbiological tests that are imprecise and time-consuming. Recently, it was demonstrated that cell-free DNA is increased in the synovial fluid of patients with PJI. Therefore, this study aims to evaluate a new point-of-care methodology for quantifying free DNA in synovial fluid. Method. A prospective study was carried out with patients undergoing TKA revision surgery, from whom it was possible to collect synovial fluid (SF) during the surgical procedure. Cell-free DNA quantification was performed directly from the SF, using a portable fluorimeter. Sensitivity, specificity and receiver operating characteristic (ROC) curve were calculated. Results. Fifty-four patients were included in the study, of which 25 were diagnosed with PJI. Cell-free DNA levels measured immediately after collection were increased in the synovial fluid of patients with PJI (26.3 ± 14.8) in comparison with the uninfected group (4.6 ng/ml ± 3.8, p< 0.0001). The area under the receiver operating characteristic curve (AUC ROC) was 0.981 (95% CI 0.914 to 0.999). Conclusions. From the results presented, we can conclude that the quantification of free DNA with a portable fluorimeter proved to be a test with high sensitivity and specificity for the diagnosis of PJI


Bone & Joint Research
Vol. 9, Issue 8 | Pages 450 - 456
1 Aug 2020
Zhang Z Cai Y Bai G Zhang C Li W Yang B Zhang W

Aims. This study aimed to evaluate calprotectin in synovial fluid for diagnosing chronic prosthetic joint infection (PJI) . Methods. A total of 63 patients who were suspected of PJI were enrolled. The synovial fluid calprotectin was tested by an enzyme-linked immunosorbent assay (ELISA). Laboratory test data, such as ESR, CRP, synovial fluid white blood cells (SF-WBCs), and synovial fluid polymorphonuclear cells (SF-PMNs), were documented. Chi-squared tests were used to compare the sensitivity and specificity of calprotectin and laboratory tests. The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was calculated to determine diagnostic efficacy. Results. The median calprotectin level was 776 μg/ml (interquartile range (IQR) 536.5 to 1132) in the PJI group and 54.5 μg/ml (IQR, 38.75 to 78.25) in the aseptic failure (AF) group (p < 0.05). Using a threshold of 173 ug/ml, the sensitivity was 95.2%, with a 97.6% specificity, and the AUC was 0.993. The sensitivity of calprotectin of the antibiotic-treated PJI group was 100% versus 90.9% of the non-antibiotic-treated PJI group. Although 47.6% (ten cases) of the patients in the PJI group received antibiotics before aspiration, the diagnostic efficacy of calprotectin was not affected. The sensitivity and specificity of ESR, CRP, SF-WBCs, and SF-PMNs ranged from 76.2% to 90.5% and 64.3% to 85.7%, respectively. Conclusion. Calprotectin in synovial fluid has great diagnostic efficacy for PJI diagnosisand outperformed ESR, CRP, SF-WBCs, and SF-PMNs. Cite this article: Bone Joint Res 2020;9(8):450–456


Bone & Joint Open
Vol. 4, Issue 1 | Pages 3 - 12
4 Jan 2023
Hardwick-Morris M Twiggs J Miles B Al-Dirini RMA Taylor M Balakumar J Walter WL

Aims. Iliopsoas impingement occurs in 4% to 30% of patients after undergoing total hip arthroplasty (THA). Despite a relatively high incidence, there are few attempts at modelling impingement between the iliopsoas and acetabular component, and no attempts at modelling this in a representative cohort of subjects. The purpose of this study was to develop a novel computational model for quantifying the impingement between the iliopsoas and acetabular component and validate its utility in a case-controlled investigation. Methods. This was a retrospective cohort study of patients who underwent THA surgery that included 23 symptomatic patients diagnosed with iliopsoas tendonitis, and 23 patients not diagnosed with iliopsoas tendonitis. All patients received postoperative CT imaging, postoperative standing radiography, and had minimum six months’ follow-up. 3D models of each patient’s prosthetic and bony anatomy were generated, landmarked, and simulated in a novel iliopsoas impingement detection model in supine and standing pelvic positions. Logistic regression models were implemented to determine if the probability of pain could be significantly predicted. Receiver operating characteristic curves were generated to determine the model’s sensitivity, specificity, and area under the curve (AUC). Results. Highly significant differences between the symptomatic and asymptomatic cohorts were observed for iliopsoas impingement. Logistic regression models determined that the impingement values significantly predicted the probability of groin pain. The simulation had a sensitivity of 74%, specificity of 100%, and an AUC of 0.86. Conclusion. We developed a computational model that can quantify iliopsoas impingement and verified its accuracy in a case-controlled investigation. This tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis. Cite this article: Bone Jt Open 2023;4(1):3–12


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 66 - 66
24 Nov 2023
d'Epenoux Louise R Robert M Caillon H Crenn V Dejoie T Lecomte R Tessier E Corvec S Bemer P
Full Access

Background. The diagnosis of periprosthetic joint infection (PJI) remains a challenge in clinical practice and the analysis of synovial fluid (SF) is a useful diagnostic tool. Recently, two synovial biomarkers (leukocyte esterase (LE) strip test, alpha-defensin (AD)) have been introduced into the MSIS (MusculoSkeletal Infection Society) algorithm for the diagnosis of PJI. AD, although promising with high sensitivity and specificity, remains expensive. Calprotectin is another protein released upon activation of articular neutrophils. The determination of calprotectin and joint CRP is feasible in a routine laboratory practice with low cost. Purpose. Our objective was to evaluate different synovial biomarkers (calprotectin, LE, CRP) for the diagnosis of PJI. Methods. In this monocentric study, we collected SF from hip, knee, ankle and shoulder joints of 42 patients who underwent revision or puncture for diagnostic purposes. Exclusion criteria included a joint surgery in the previous 3 months and a diagnosis of a systemic inflammatory disease. PJI was diagnosed in a multidisciplinary consultation meeting (RCP) of the Reference Centers for Osteoarticular Infections of the Great West (CRIOGO). SF was analysed for LE, CRP and calprotectin. The cut-off values used were 50 mg/L for calprotectin, 8.8 mg/L for CRP and 125 WBC/µL for LE. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for these different synovial markers. Results. Of the 42 patients included, 28 were considered as infected and 14 uninfected. The statistical parameters are presented in Table 1. Conclusion. The present study shows that the synovial calprotectin assay has an excellent sensitivity and a 100% NPV for the diagnosis of PJI, suggesting that a result < 50 mg/L could exclude PJI. This promising study suggests that calprotectin should be included with synovial CRP in a new decision algorithm for the diagnosis of PJI. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 43 - 43
22 Nov 2024
Bekkers W Zwart V Swietoslawki A Oost IK Nijs A Emmen J Van Geenen R
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the main reasons for revision surgery after primary unicompartmental knee arthroplasty (UKA), total knee arthroplasty (TKA) or total hip arthroplasty (THA). Currently the MSIS and EBJIS criteria sets are considered to be the gold standards in determining PJI. These criteria sets are complex and contain tests that are time-consuming and many are rather costly. Therefore, further research is indicated to find a simpler but equally reliable diagnostic test. In this study we evaluated the additional value of calprotectine measurement in synovial fluid in patients undergoing hip and knee (revision) arthroplasty following routine work-up. Method. In a retrospective cohort study, we analyzed 182 synovial fluid samples from 143 patients with suspected PJI after UKA, TKA, THA or revision arthroplasty. Twenty-six of those cases were classified as PJI according to the MSIS and EBJIS criteria. Subsequently, synovial calprotectin was determined, using a lateral flow assay and two cut-off thresholds of ≥14 mg/L and ≥50 mg/L. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of synovial calprotectin was determined. Results. When applying the MSIS and EBJIS criteria and a calprotectin level ≥14 mg/L, synovial calprotectin revealed an area under the curve of 0.96 (95% CI 0.90-1.00), with 92.3% sensitivity and 100% specificity. The PPV and NPV were 100% and 92.9% respectively. When applying the MSIS and EBJIS criteria and a calprotectin level ≥ 50 mg/L, synovial calprotectin revealed an area under the curve of 0.94 (95% CI 0.87-1.00), with 88.5% sensitivity and 100% specificity. The PPV and NPV were 100% and 89.7% respectively. Conclusions. The value of calprotectin in synovial fluid gives valuable information with a single test result, resulting in high predictive value in the diagnosis of PJI after hip or knee arthroplasty and should seriously be considered as part of PJI diagnostics in an outpatient clinical setting. The high specificity can help rule in patients that are suspected of PJI. Therefor this test can be helpful in a preop diagnostic work-up to avoid unnecessary revisions in patients with well-placed and well-fixed arthroplasties with a suspected PJI. These conclusions are independent of which criteria set was used as a gold standard


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 71 - 71
24 Nov 2023
Heesterbeek P Pruijn N Boks S van Bokhoven S Dorrestijn O Schreurs W Telgt D
Full Access

Aim. Diagnosis of periprosthetic shoulder infections (PSI) is difficult as they are mostly caused by low-virulent bacteria and patients do not show typical infection signs, such as elevated blood markers, wound leakage, or red and swollen skin. Ultrasound-guided biopsies for culture may therefore be an alternative for mini-open biopsies as less costly and invasive method. The aim of this study was to determine the diagnostic value and reliability of ultrasound-guided biopsies for cultures alone and in combination polymerase chain reaction (PCR), and/or synovial markers for preoperative diagnosis of PSI in patients undergoing revision shoulder surgery. Method. A prospective explorative diagnostic cohort study was performed including patients undergoing revision shoulder replacement surgery. A shoulder puncture was taken preoperatively before incision to collect synovial fluid for interleukin-6 (IL-6), calprotectin, WBC, polymorphonuclear cells determination. Prior to revision surgery, six ultrasound-guided synovial tissue biopsies were collected for culture and two additional for PCR analysis. Six routine care tissue biopsies were taken during revision surgery and served as reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV; primary outcome measure), and accuracy were calculated for ultrasound-guided biopsies, and synovial markers, and combinations of these. Results. Fifty-five patients were included. In 24 patients, routine tissue cultures were positive for infection. Cultures from ultrasound-guided biopsies diagnosed an infection in 7 of these patients, yielding a sensitivity, specificity, PPV, NPV, and accuracy of 29.2%, 93.5%, 77.8%, 63.0%, and 65.6%, respectively. Ultrasound-guided biopsies in combination with synovial WBC increased the NPV to 76.7% and accuracy to 73.8%. When synovial WBC and calprotectin were combined with ultrasound-guided biopsies, it resulted in a better diagnostic value: sensitivity 69.2%, specificity 80.0%, PPV 69.2%, NPV 80.0%, and accuracy 75.8%. Ultrasound-guided biopsies in combination with calprotectin and ESR yielded a sensitivity of 50.0%, specificity of 93.8%, PPV of 80.0%, NPV of 78.9%, and accuracy of 79.2%. Synovial fluid was obtained in 42 patients. Sensitivities of WBC, PMN, IL-6, and calprotectin were between 25.0% and 35.7%, specificities between 89.5% and 95.0%, PPVs between 60.0% and 83.3%, NPVs between 65.4% and 69.4%, and accuracies between 64.5% and 70.6%. Conclusions. In this prospective study we showed that ultrasound-guided biopsies for cultures alone and in combination with PCR and/or synovial markers are not reliable enough to use in clinical practice for the preoperative diagnosis of low grade PSI


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 8 - 8
1 Feb 2021
Pour AE Patel K Anjaria M Schwarzkopf R Dorr L Lazennec J
Full Access

Introduction. Sagittal pelvic tilt (SPT) can change with spinal pathologies and fusion. Change in the SPT can result in impingement and hip instability. Our aim was to determine the magnitude of the SPT change for hip instability to test the hypothesis that the magnitude of SPT change for hip instability is less than 10° and it is not similar for different hip motions. Methods. Hip implant motions were simulated in standing, sitting, sit-to-stand, bending forward, squatting and pivoting in Matlab software. When prosthetic head and liner are parallel, femoral head dome (FHD) faces the center of the liner. FHD moves toward the edge of the liner with hip motions. The maximum distance between the FHD and the center in each motion was calculated and analyzed. To make the results more reliable and to consider the possibility of bony impingement, when the FHD approached 90% of the distance between the liner-center and liner-edge, we considered the hip “in danger for dislocation”. The implant orientations and SPT were modified by 1-degree increments and we used linear regression with receiver operating characteristic (ROC) curve and area under the curve (AUC) to determine the magnitude of SPT change that could cause instability. Results. SPT modification as low as 7° could result in dislocation during pivoting (AUC: 87.5; sensitivity: 87.9; specificity 79.8; p=0.0001). This was as low as 10° for squatting (AUC: 91.5; sensitivity: 100; specificity 75.9; p=0.0001) and as low as 13° for sit-to-stand (AUC: 94.6; sensitivity: 98; specificity 83; p=0.0001). SPT modification affects hip stability more in pivoting than sit-to-stand and squatting. Discussion. Our results show the importance of close collaboration between the hip and spine surgeons in treating patients who undergo THA and spinal fusion. The postoperative SPT modification should be considered for preoperative computer simulation for determining the implant safe zone