Reports of improved functional outcome of Metal on Metal Hip
Purpose. This study was performed to evaluate clinical and radiographic outcomes of Hip
Humeral resurfacing arthroplasty has been advocated as an alternative to stemmed humeral component designs given its ability to preserve proximal bone stock. Further, these implants have become more attractive given the possibility of stem-related complications including humeral fracture, stress shielding, and osteolysis; complications that may necessitate fixation, revision to long stem components, or reverse total shoulder arthroplasty. As more total shoulder arthroplasties are performed in younger patient populations, the likelihood of increased revision procedures is inevitable. Maintaining proximal bone stock in these cases with use of a resurfacing arthroplasty not only facilitates explant during revision arthroplasty, but preservation of proximal metaphyseal bone facilitates reimplantation of components. Clinical results of these resurfacing components have demonstrated favorable results similar to stemmed designs. Unfortunately, resurfacing arthroplasty may not be as ideal as was hoped with regard to recreating native humeral anatomy. Further, resurfacing arthroplasty may increase the risk of peri-prosthetic humeral fracture, and lack of a formal humeral head cut makes glenoid exposure more difficult, which may be associated with a higher degree of neurovascular injury. Stemless humeral components are designed for strong metaphyseal fixation and avoid the difficulty with glenoid exposure seen in resurfacing designs, as these components require a formal humeral head cut. Early clinical outcomes of a single stemless design demonstrated significant improvements in clinical outcome scores, without evidence of component migration, subsidence or loosening. The only mid-term clinical results of stemless design implants are seen with the Arthrex Eclipse system (Arthrex, Naples, FL). In a prospective study involving 78 patients at 5-year follow-up, significant improvements were observed in clinical outcome scores. While there was evidence of proximal stress shielding in an older population, this did not influence shoulder function. The overall revision rate was 9% at 5 years, with no component necessitating revision as a result of humeral component loosening.
Aim: The aim of this study was to assess the role of Hip Arthroscopy in the patient with a symptomatic
Introduction: The suitability of third generation metal-on-metal hip resurfacing for patients with a primary diagnosis of osteonecrosis (ON) has been debated. The preservation of femoral head bone stock for femoral prosthetic support is essential for long term stability of the implant. We hypothesized that the Kaplan-Meier survival estimates for resurfacing patients with a primary diagnosis of ON would be significantly lower than the survival estimates for resurfacing patients with a primary diagnosis of osteoarthritis (OA). Methods: One thousand one hundred and forty-eight patients were implanted with a modern hip resurfacing system as part of a United States multi-center investigational device exemption (IDE) study. Of these, 116 subjects had a preoperative diagnosis of ON. A multivariate analysis of variance was performed to identify risk factors for component revision for any reason. Results: A diagnosis other than OA was found to be one significant risk factor for revision. However, the survival estimates were not significantly different (95.9% and 95.8% at 24 months for OA and ON, respectively, p=0.46) when comparing the OA group to the ON group. Comparing only the Ficat stage III and IV to the OA population also did not show a significant difference in implant survival (95.9% OA and 96.1% ON III/IV at 24 months, p=0.57). Discussion:
The Birmingham
Introduction:
Purpose: A multicenter prospective evaluation of the Conserve Plus resurfacing implant (Wright Medical Technology) was undertaken to assess clinical and radiographic outcomes as well as ion levels. This study focuses on the serum, erythrocyte and urinary levels of cobalt and chromium in those patients undergoing hip resurfacing arthroplasty. Methods: A subset of patients enrolled in a multicenter trial to assess hip resurfacing arthroplasty had serum, erythrocyte and urinary cobalt and chromium levels measured. Levels were assessed preoperatively, then at three months, six months then yearly thereafter. Clinical outcome measurements were performed with WOMAC and Rand questionnaires. Results: Fifty-four out of 124 patients enrolled in the overall study had cobalt and chromium ion assessments performed. During the first year there was an increase in serum cobalt levels from 1.4 ug/l at 3 months to 2.4 ug/l at one year. Serum chromium levels increased from 1.4 ug/l at 3 months to 3.5 ug/l at one year. Erythrocyte cobalt levels increased from 0.8 ug/l at 3 months to 1.4 ug/l at one year. Erythrocyte chromium levels decreased from 1.5 ug/l at 3 months to 1.4 ug/l at one year. Urinary levels for cobalt increased from 12.7 ug/l at 3 months to 13.8 ug/l at one year. Urinary chromium levels rose from 4.0 ug/l at 3 months to 5.1 ug/l at one year. Conclusions: Increasing ion levels were seen during the first year post hip resurfacing arthroplasty. Clinical outcomes demonstrate predictable improvements in pain and function consistent with hip replacement surgery.
Purpose of study: We report the results of a prospective case series of 10 patients who developed tumour-like masses following resurfacing arthroplasty. Method: Ten subjects were referred to the tumour service at the Nuffield Orthopaedic Centre with symptomatic masses around the hip, all had previously received a resurfacing arthroplasty. We report the clinical, radiographic and histologic features of these cases. Results: MRI and ultrasound scanning was preformed, which demonstrated masses with solid and cystic components. Biopsy was performed and subsequent histological examination revealed a profound plasma-cell lymphocytic response associated with metal wear debris. There were no infections in this series. Three subjects required revision surgery. Conclusion: Over 50,000 resurfacing arthroplasties have been implanted worldwide over the past ten years. Although the early clinical results are encouraging little is known about the long term consequences of large head metal on metal bearing surfaces. Despite this, these devices are being widely marketed and are often implanted in younger patients.
Aim: We present the outcome of Birmingham Hip
Introduction. Hip
Introduction. There is no consensus on the ideal management of young, active patients with disabling coxarthrosis. Within this group, patients with femoral head defects secondary to cysts or avascular necrosis pose particular challenges.
Aims:
Purpose:
A ceramic-on-ceramic hip resurfacing implant (cHRA) was developed and introduced in an MHRA-approved clinical investigation to provide a non metallic alternative hip resurfacing product. This study aimed to examine function and physical activity levels of patients with a cHRA implant using subjective and objective measures both before and 12 months following surgery in comparison with age and gender matched healthy controls. Eighty-two unilateral cHRA patients consented to this study as part of a larger prospective, non-randomised, clinical investigation. In addition to their patient reported outcome measures (PROMs), self- reported measures of physical activity levels and gait analysis were undertaken both pre- operatively (1.5 weeks) and post operatively (52 weeks). This data was then compared to data from a group of 43 age gender and BMI matched group of healthy controls. Kinetics and kinematics were recorded using an instrumented treadmill and 3D Motion Capture. Statistical parametric mapping was used for analysis. cHRA improved the median Harris Hip Score from 63 to 100, Oxford Hip score from 27 to 48 and the MET from 5.7 to 10.3. cHRA improved top walking speed (5.75km vs 7.27km/hr), achieved a more symmetrical ground reaction force profile, (Symmetry Index value: 10.6% vs 0.9%) and increased hip range of motion (ROM) (31.7° vs 45.9°). Postoperative data was not statistically distinguishable from the healthy controls in any domain. This gait study sought to document the function of a novel ceramic hip resurfacing, using those features of gait commonly used to describe the shortcomings of hip arthroplasty. These features were captured before and 12 months following surgery. Preoperatively the gait patterns were typical for OA patients, while at 1 year postoperatively, this selected group of patients had gait patterns that were hard to distinguish from healthy controls despite an extended posterior approach. Applications for regulatory approval have been submitted.
Introduction: Preliminary results of the Birmingham Hip
In 1997 the Birmingham Hip Resurfacing was introduced to address the needs of young active patients. Alternative designs were introduced to try and improve wear performance. The aim of this study was a comparative cohort study of two types of metal-on-metal bearing to determine the mechanism of failure at 15 years. The study reviewed 91 Brimingham Hip Resurfacings (BHR) (Smith and Nephew) and 715 DUROM hip resurfacing (Zimmer) procedures in prior to 2009. Failure was defined as revision of either component for any reason. Kaplan-Meyer survivorship analysis performed. Routine follow-up with serum metal ion levels and radiographs. Mean follow-up was 17.9 years (range 15.2 – 25.1). The mean age at operation was 51.6 years (SD 8.6, range 20.7 to 70.2), including 299 women (37.1%). The Birmingham resurfacing demonstrated 92.3% survivorship at 15 years (SE 2.8, 95% CI 3.9 – 7.8) and 90.0% at latest follow-up (SE 3.5, 95% CI 4.9 to 9.4). By comparison, the DUROM survivorship at 15 years was 89.1% at 15 years (SE 1.2, 95% CI 2.0 to 2.5) and 87.4% (SE 1.3, 95% CI 2.5 to 2.3) at latest follow-up. There was no statistically significant difference in survivorship between groups (p= 0.32). Survival in male patients was 92.7% compared to 80.0% in females. The reported failures occurred from Adverse Reaction to Metal Debris (32 patients), periprosthetic femoral neck fracture (6) and aseptic loosening (41), PJI (12) and undiagnosed pain (6). The mean cobalt and chromium levels at last follow-up were 33.4 nmol/L and 36.5 nmol/L respectively. This study demonstrates two differently designed metal-on-metal hip resurfacing provided a durable alternative to total hip replacement, particularly in younger male patients with osteoarthritis. Differences in design did determine the reason for revision with acetabular fixation being one of the principal failure mechanisms for the DUROM compared to elevated ion levels.
Iliopsoas tendonitis occurs in up to 30% of patients after hip resurfacing arthroplasty (HRA) and is a common reason for revision. The primary purpose of this study was to validate our novel computational model for quantifying iliopsoas impingement in HRA patients using a case-controlled investigation. Secondary purpose was to compare these results with previously measured THA patients. We conducted a retrospective search in an experienced surgeon's database for HRA patients with iliopsoas tendonitis, confirmed via the active hip flexion test in supine, and control patients without iliopsoas tendonitis, resulting in two cohorts of 12 patients. The CT scans were segmented, landmarked, and used to simulate the iliopsoas impingement in supine and standing pelvic positions. Three discrete impingement values were output for each pelvic position, and the mean and maximum of these values were reported. Cup prominence was measured using a novel, nearest-neighbour algorithm. The mean cup prominence for the symptomatic cohort was 10.7mm and 5.1mm for the asymptomatic cohort (p << 0.01). The average standing mean impingement for the symptomatic cohort was 0.1mm and 0.0mm for the asymptomatic cohort (p << 0.01). The average standing maximum impingement for the symptomatic cohort was 0.2mm and 0.0mm for the asymptomatic cohort (p << 0.01). Impingement significantly predicted the probability of pain in logistic regression models and the simulation had a sensitivity of 92%, specificity of 91%, and an AUC ROC curve of 0.95. Using a case-controlled investigation, we demonstrated that our novel simulation could detect iliopsoas impingement and differentiate between the symptomatic and asymptomatic cohorts. Interestingly, the HRA patients demonstrated less impingement than the THA patients, despite greater cup prominence. In conclusion, this tool has the potential to be used preoperatively, to guide decisions about optimal cup placement, and postoperatively, to assist in the diagnosis of iliopsoas tendonitis.
Although hip replacement and resurfacing procedures both aim to restore mobility, improve joint function, and relieve pain, it is unclear how each differ in terms of gait mechanics and if they are affected by varying walking speeds. We compared limb symmetry and ground reaction force (GRF) profiles between bilateral total hip arthroplasty patients (THA), bilateral hip resurfacing arthroplasty patients (HRA), and healthy control participants (CON) during level-treadmill walking at different speeds. Bilateral THA and bilateral HRA patients (nTHA = 15; nHRA = 15; postoperative 12–18 months), and age-, mass-, and height-matched CON participants (nCON = 20) underwent gait analysis on an instrumented treadmill. Walking trials started at 4 km/h and increased in 0.5 km/h increments until top walking speed (TWS) was achieved. Gait symmetry index (SI = 0% for symmetry) was assessed between limbs during weight-acceptance, mid-stance and push-off phases of gait; and vertical GRFs were captured for the normalised stance phase using statistical parametric mapping (SPM; CI = 95%).Abstract
Objectives
Methods