Introduction. The mobile-bearing (MB) total knee arthroplasty (TKA) design was introduced with the aim of reducing polyethylene wear and component loosening seen in the fixed-bearing (FB) design. A recent joint
The aim of this study was to compare the relative performance of total hip replacement constructs and discern if there is substantial variability in performance in currently commonly used prostheses. All patients who underwent a primary total hip replacement (THR) registered in the NZJR between 1st January 1999 to June 2020 were identified. Using a noninferiority analysis, the performance of hip prostheses were compared with the best performing contemporary construct. Construct failure was estimated using the 1-Kaplan Meier survival function method to estimate net failure. The difference in failure between the contemporary benchmark and other constructs was examined. In total 135 432 THR were recorded comprising 1 035 different THR constructs. Notably 328 constructs were used just once. 48 constructs (62 251 THR) had >500 procedures at risk at 3 years post-primary of which 28 were inferior by at least 20% relative risk of which, 10 were inferior by at least 100% relative risk. 16 constructs were identified with >500 procedures at risk at 10 years with 9 inferior by at least 20%, of which one was inferior by >100% relative risk. There were fewer constructs noninferior to the best practice benchmark when we performed analysis by gender. In females at 10 years, from 5 constructs with >500 constructs at risk, 2 were inferior at the 20% margin. In males at 10 years, there were only 2 eligible constructs of which one was inferior at the 20% margin. We discerned that there is substantial variability in construct performance and at most time points, just over half of constructs are inferior to the best performing construct by at least 20%. These results can facilitate informed decision-making when considering THR surgery.
Multiple joint registries have reported better implant survival for patients aged >75 years undergoing total hip arthroplasty (THA) with cemented implant combinations when compared to hybrid or uncemented implant combinations. However, there is considerable variation within these broad implant categories, and it has therefore been suggested that specific implant combinations should be compared. We analysed the most common contemporary uncemented (Corail/Pinnacle), hybrid (Exeter V40/Trident) and cemented (Exeter V40/Exeter X3) implant combinations in the New Zealand Joint Registry (NZJR) for patients aged >75 years. All THAs performed using the selected implants in the NZJR for patients aged >75 years between 1999 and 2018 were included. Demographic data, implant type, and outcome data including implant survival, reason for revision, and post-operative Oxford Hip Scores were obtained from the NZJR, and detailed survival analyses were performed. Primary outcome was revision for any reason. Reason for revision, including femoral or acetabular failure, and time to revision were recorded. 5427 THAs were included. There were 1105 implantations in the uncemented implant combination group, 3040 in the hybrid implant combination group and 1282 in the cemented implant combination group. Patient reported outcomes were comparable across all groups. Revision rates were comparable between the cemented implant combination (0.31 revisions/100 component years) and the hybrid implant combination (0.40 revisions/100 component years) but were statistically significantly higher in the uncemented implant combination (0.80/100 component years). Femoral-sided revisions were significantly greater in the uncemented implant combination group. The cemented implant and hybrid implant combinations provide equivalent survival and functional outcomes in patients aged over 75 years. Caution is advised if considering use of the uncemented implant combination in this age group, predominantly due to a higher risk of femoral sided revisions. The authors recommend comparison of individual implants rather than broad categories of implants.
Post-operative periprosthetic femoral fractures (PFF) are a devastating complication associated with high mortality and are costly. Few risk factors are modifiable apart from implant choice. The design features governing risk of PFF are unknown. We estimated the 90-day risk of revision for PFF associated with design features of cementless femoral stems and to investigate the effect of a collar on early PFF risk using a biomechanical in-vitro model. 337 647 primary THAs from the National Joint Registry (UK) were included in a multivariable survival and regression analysis to identify the adjusted hazard of PFF revision following primary THA using cementless stems. The effect of a collar in cementless THA on early PFF was evaluated in an in-vitro model using paired fresh frozen cadaveric femora.Background
Patients, materials and methods
A long surgical procedure length has been well associated with worse clinical outcomes, also in an economic climate where in the theatre, time is money, surgical procedures are done very rapidly. Few studies have documented the clinical outcomes of procedure speed. Using the New Zealand Registry we reviewed the operation time of 41,560 primary knee joint replacements. These were split into groups of time slots for the surgery from less than 40 minutes, 40–59, 60–89, 90–119, 120–179 and greater than 180mins. This was referenced to the oxford knee scores obtained and the revision rate. For operations done in less than 40 or greater than 180 minutes, the oxford knee score was lower by 5 years. The revision rate was also increased in these same groups. Operations done in greater than 180 minutes are generally the more complex non-osteoarthrtic and tumour cases and have a higher revision rate reflecting their complexity. Procedures done less than 40 minutes are more straight forward, but there is a relationship shown between this speed and revision rate and poorer outcome. The cause is likely multifactorial, but begs the question, does speed kill?
Aims. Body exhaust suits or surgical helmet systems (colloquially, ‘space suits’) are frequently used in many forms of arthroplasty, with the aim of providing personal protection to surgeons and, perhaps, reducing periprosthetic joint infections, although this has not consistently been borne out in systematic reviews and
Aims. The aim of this study was to perform a systematic review and bias evaluation of the current literature to create an overview of risk factors for re-revision following revision total knee arthroplasty (rTKA). Methods. A systematic search of MEDLINE and Embase was completed in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. The studies were required to include a population of index rTKAs. Primary or secondary outcomes had to be re-revision. The association between preoperative factors and the effect on the risk for re-revision was also required to be reported by the studies. Results. The search yielded 4,847 studies, of which 15 were included. A majority of the studies were retrospective cohorts or
Obesity is a known risk factor for hip osteoarthritis. The aim of this study was to compare the incidence of obesity in Australians undergoing hip replacements (HR) for osteoarthritis to the general population. A cohort study was conducted comparing data from the Australian Bureau of Statistics and the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) from 2017-18. Body mass index (BMI) data for patients undergoing primary total hip replacement and resurfacing for osteoarthritis were obtained from the AOANJRR. The distribution of HR patients by BMI category was compared to the general population, in age and sex sub-groups. During the study period, 32,495 primary HR were performed for osteoarthritis in Australia. Compared to the general population, there was a higher incidence of Class I, II, and III obesity in patients undergoing HR in both sexes aged 35 to 74 years old. Class III obese females and males undergoing HR were on average 6 to 7 years younger than their normal weight counterparts. Class III obese females and males aged 55-64 years old were 2.9 and 1.7 times more likely to undergo HR, respectively (p<0.001). There is a strong association between increased BMI and relative risk of undergoing HR. Similar findings have been noted in the United States of America, Canada, United Kingdom, Sweden and Spain. A New Zealand
Aims. The aim of this study was to report patient and clinical outcomes following robotic-assisted total knee arthroplasty (RA-TKA) at multiple institutions with a minimum two-year follow-up. Methods. This was a multicentre
Aim. To date, the value of culture results after a debridement, antibiotics and implant retention (DAIR) for early (suspected) prosthetic joint infection (PJI) as risk indicators in terms of prosthesis retention is not clear. At one year follow-up, the relative risk of prosthesis removal was determined for culture-positive and culture-negative DAIRs after primary total hip or knee arthroplasty. The secondary aim was to explore differences in patient characteristics, infection characteristics and outcomes between these two groups. Methods. A retrospective regional
The benefit of using acetabular screws in primary total hip arthroplasty (THA) has been questioned in recent years. The disadvantages of using screws include increased operative time, risk of injury to surrounding neurovascular structures and metal ware breakage. Recent large
Aims. Early detection of developmental dysplasia of the hip (DDH) is associated with improved outcomes of conservative treatment. Therefore, we aimed to evaluate a novel screening programme that included both the primary risk factors of breech presentation and family history, and the secondary risk factors of oligohydramnios and foot deformities. Methods. A five-year prospective
Recent registry data from around the world has strongly suggested that using cemented hip hemiarthroplasty has lower revision rates compared to cementless hip hemiarthroplasty for acute femoral neck hip fractures. The adoption of using cemented hemiarthroplasty for hip fracture has been slow as many surgeons continue to use uncemented stems. One of the reasons is that surgeons feel more comfortable with uncemented hemiarthroplasty as they have used it routinely. The purpose of this study is to compare the difference in revision rates of cemented and cementless hemiarthroplasty and stratify the risk by surgeon experience. By using a surgeons annual volume of Total Hip Replacements performed as an indicator for surgeon experience. The Canadian Joint Replacement Registry Database was used to collect and compare the outcomes to report on the revision rates based on surgeon volume. This is a large Canadian
Recent registry data from around the world has strongly suggested that using cemented hip hemiarthroplasty has lower revision rates compared to cementless hip hemiarthroplasty for acute femoral neck hip fractures. The adoption of using cemented hemiarthroplasty for hip fracture has been slow as many surgeons continue to use uncemented stems. One of the reasons is that surgeons feel more comfortable with uncemented hemiarthroplasty as they have used it routinely. The purpose of this study is to compare the difference in revision rates of cemented and cementless hemiarthroplasty and stratify the risk by surgeon experience. By using a surgeons annual volume of Total Hip Replacements performed as an indicator for surgeon experience. The Canadian Joint Replacement Registry Database was used to collect and compare the outcomes to report on the revision rates based on surgeon volume. This is a large Canadian
Aims. The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid total hip arthroplasties (THAs). Methods. We undertook a
Special acetabular polyethylene (PE) liners are intended to increase the stability of the artificial hip joint, yet
Aims. To investigate the effect of polyethylene manufacturing characteristics and irradiation dose on the survival of cemented and reverse hybrid total hip arthroplasties (THAs). Methods. In this
Background. The acknowledged benefit of the direct anterior (DA) approach is early functional return. Most surgeons in the U.S. use cementless femoral replacement given the negative track record of some cemented designs. However, delayed osseointegration of a femoral stem typically seen in older patients with poor bone quality will delay recovery, diminishing the benefits of the DA approach.
Background. The purpose of this study was to report functional outcome scores following arthroscopic acetabular chondral procedures using the U.K. Non-Arthroplasty Hip Registry (NAHR). Methods. Data on adult patients who underwent hip arthroscopy between January 2012 and December 2018 was extracted from the NAHR. Patients who underwent femoral sided chondral procedures were excluded. Patients who underwent osteophyte excision or a concurrent extra-articular procedure were also excluded. Cases were then classified according to the acetabular chondral procedure performed – ‘chondroplasty’, ‘microfracture’ or ‘none’ (no chondral procedure recorded). Outcomes comprised EuroQol-5 Dimensions (EQ-5D) index and the International Hip Outcome Tool 12 (iHOT-12), preoperatively and at 6 and 12 months. Results. A total of 4,978 arthroscopies were identified (chondroplasty 26.4%, microfracture 5.4%, none 68.2%). Patients who underwent microfracture were significantly older (37.9y vs 37.3y) and of higher BMI (26.4 vs 25.8 kg/m2) than patients who underwent chondroplasty. Pre-operative, 6 and 12-month follow-up were available for 77%, 42% and 38% of cases respectively. This
Cemented acetabular components commonly have a long posterior wall (LPW). Alternative components have a hooded or offset reorientating geometry, theoretically to reduce the risk of THR instability. We aimed to determine if cemented acetabular component geometry influences the risk of revision surgery for instability or loosening. The National Joint Registry for England, Wales and Northern Ireland (NJR) dataset was analysed for primary THAs performed between 2003 – 2017. A cohort of 224,874 cemented acetabular components were identified. The effect of acetabular component geometry on the risk of revision for instability or for loosening was investigated using binomial regression adjusting for age, gender, ASA grade, diagnosis, side, institution type, operating surgeon grade, surgical approach, polyethylene crosslinking and head size. A competing risk survival analysis was performed with the competing risks being revision for other indications or death. Among the cohort of subjects included, the distribution of acetabular component geometries was: LPW – 81.2%, hooded – 18.7% and offset reorientating – 0.1%. There were 3,313 (1.47%) revision THAs performed, of which 815 (0.36%) were for instability and 838 (0.37%) were for loosening. Compared to the LPW group, the adjusted subhazard ratio of revision for instability in the hooded group was 2.29 (p<0.001) and 4.12 (p=0.047) in the offset reorientating group. Likewise, the subhazard ratio of revision for loosening was 2.43 (p<0.001) in the hooded group and 11.47 (p<0.001) in the offset reorientating group. A time-varying subhazard ratio of revision for instability (hooded vs LPW) was found, being greatest within the first 6 months. This