The attitudes of orthopaedic surgeons regarding
Aims. Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused highly cross-linked polyethylene (VEPE) promises strong wear resistance, high oxidative stability, and superior mechanical strength. Although VEPE monoblock cups have shown good mid-term performance and excellent wear patterns, long-term results remain unclear. This study evaluated migration and wear patterns and clinical and
Imaging can provide valuable information about the function of tissues and organs. The capacity for detecting and measuring imaging biomarkers of biological activities, allows for a better understanding of the pathophysiology of any process in the human body, including the musculoskeletal system. This is of particular importance in oncologic, metabolic and rheumatologic diseases, but not limited to these. In the domain of the musculoskeletal system, functional imaging also means to be able to address biomechanical evaluations. Weight-bearing imaging and dynamic studies have a prominent role. All imaging techniques (X-rays, CT, MR, ultrasound) are in demand, and offer different applications, specific equipment and novel methods for addressing this. Functional imaging is also essential to drive minimally invasive treatments – i.e. interventional
Aims. Although the short stem concept in hip arthroplasty procedure shows acceptable clinical performance, we sometimes get unexplainable
Aims. To assess the incidence of
Aims. The first metatarsal pronation deformity of hallux valgus feet is widely recognized. However, its assessment relies mostly on 3D standing CT scans. Two
Aims. Hip dysplasia (HD) leads to premature osteoarthritis. Timely detection and correction of HD has been shown to improve pain, functional status, and hip longevity. Several time-consuming
Cartilage lesions vary in the spectrum from benign enchondromas to highly malignant dedifferentiated chondrosarcomas. From the treatment perspective, enchondromas are observed, Grade 1 chondrosarcomas are curetted like aggressive benign tumors, and rest are resected like other sarcomas. Although biopsy for tissue diagnosis is the gold standard for diagnosis and grade determination in chondrosarcoma, tumor heterogeneity limits the grading in patients following a biopsy. In the absence of definite pre-treatment grading, a surgeon is therefore often in a dilemma when deciding the best treatment option.
Aims. Dead-space management, following dead bone resection, is an important element of successful chronic osteomyelitis treatment. This study compared two different biodegradable antibiotic carriers used for dead-space management, and reviewed clinical and
Aims. Limb salvage in bone tumour patients replaces the bone with massive segmental prostheses where achieving bone integration at the shoulder of the implant through extracortical bone growth has been shown to prevent loosening. This study investigates the effect of multidrug chemotherapy on extracortical bone growth and early
Aims. The diversity of femoral morphology renders femoral component sizing in total hip arthroplasty (THA) challenging. We aimed to determine whether femoral morphology and femoral component filling influence early clinical and
This systematic review aims to identify 3D predictors derived from biplanar reconstruction, and to describe current methods for improving curve prediction in patients with mild adolescent idiopathic scoliosis. A comprehensive search was conducted by three independent investigators on MEDLINE, PubMed, Web of Science, and Cochrane Library. Search terms included “adolescent idiopathic scoliosis”,“3D”, and “progression”. The inclusion and exclusion criteria were carefully defined to include clinical studies. Risk of bias was assessed with the Quality in Prognostic Studies tool (QUIPS) and Appraisal tool for Cross-Sectional Studies (AXIS), and level of evidence for each predictor was rated with the Grading of Recommendations, Assessment, Development, and Evaluations (GRADE) approach. In all, 915 publications were identified, with 377 articles subjected to full-text screening; overall, 31 articles were included.Aims
Methods
Background. Accurate and reproducible
Introduction. Surgical planning for Patient Specific Instrumentation (PSI) in total knee arthroplasty (TKA) is based on static non-functional imaging (CT or MRI). Component alignment is determined prior to any assessment of clinical soft tissue laxity. This leads to surgical planning where assumptions of correctability of preoperative deformity are false and a need for intraoperative variation or abandonment of the PSI blocks occurs. The aim of this study is to determine whether functional
Background. Patellar instability is a complex, multi-factorial disorder. Radiological assessment is regarded as an important part of the management of this population. The purpose of this study was to determine the intra- and inter-rater reliability of common
Introduction. Cup malposition in hip arthroplasty and hip resurfacing is associated with instability, accelerated wear, and the need for revision. The current study assesses the validity of intraoperative assessment using a specialized software to analyze intraoperative radiographs. Methods. Cup orientation as measured on intraoperative radiography using the RadLink Galileo Positioning System was assessed in 10 patients. These radiographs were measured by personnel trained to support the system. The results were compared to cup orientation measured by CT. Cup orientation on CT was measured by first identifying the Anterior Pelvic Plane Coordinate system landmarks on a 3D surface model. A multiplanar reconstruction module then allowed for the creation of a plane parallel with the opening plane of the acetabulum. The orientation of the cup opening plane in the AP Plane coordinate space was then calculated. The same definition of cup orientation was used for both methodologies. Results. As compared to direct measurement using CT, the intraoperative radiograph system underestimated anteversion by an average of 8.0 degrees and overestimated cup inclination by 2.9 degrees. The radiographic measurement error in anteversion ranged from −27.4 to +4.0. degrees and for inclination ranged from −2.0 to +5.3 degrees. Conclusion. The use of an intraoperative
Classification of osteoarthritis of the hip is fraught with difficulty Although different patterns of disease are recognised, there is no accepted classification or grading system. We aim to develop a classification system that reflects both the
Purpose: The role of hip aspiration as a preoperative investigation for the painful hip remains controversial. Since 1999, we have performed hip aspiration under local anaesthetics in the X-ray department. This paper reviews our experience with this technique. Results: Hip aspirations were carried out subsequently on 182 patients from November 1999 to November 2002. Out of 68 patients that underwent revision hip surgery, 63 were included in the study. Three of the five patients excluded had received antibiotics at induction prior to obtaining the operative samples and two did not have any operative samples taken at the time of surgery. Fifteen (23.8%) of the 63 hips were found to be infected based on operative tissue cultures. The sensitivity and specificity of the test were 80% and 87.5%, respectively. Positive and negative predictive values were 66.6% and 93.3% respectively and the accuracy was 85.7%. Conclusion: Hip aspiration in the
Purpose. The majority (73%) of orthopaedic surgeons in Canada prefer using semitendinosus-gracilis (STG) autograft for ACL reconstruction. However, there is large variation in tendon size between individuals which makes pre-operative estimation of graft size unpredictable. Inadequate graft size may require an alternative source of graft tissue that should be planned prior to surgery. The purpose of this study is to determine if clinical anthropometric data and MRI measurements of STG tendons can be used to predict hamstring graft size. Method. One-hundred and fourteen patients with ACL deficiency awaiting reconstruction using hamstring autograft were retrospectively evaluated. The following information was obtained from patient charts: height, weight, body mass index (BMI), age, and gender. Cross-sectional area (CSA) of gracilis (G) and semitendinosus (ST) tendons were determined from pre-operative MRI scans using NIH ImageJ analysis software. Actual STG graft diameters were obtained from operative reports. Correlations between patient height, weight, BMI, age, gender, ST-CSA, G-CSA, STG-CSA and intraoperative graft size were calculated to determine the association between these variables. Multiple stepwise regression was performed to assess the predictive value of these variables to intraoperative graft diameter. In addition, three investigators with no