The management of proximal femoral bone loss is a significant challenge in revision hip arthroplasty. A possible solution is the use of a modular proximal femur endoprosthesis (EPR). Although the survivorship and functional outcome of megaprostheses used in tumour surgery has been well described, outcome of EPRs used in revision hip surgery has received less attention. The aim of this study was to determine the 5-year outcome following proximal femur EPR and determine factors that influence it. This was a retrospective consecutive case series of all EPRs (n=80) performed for non-neoplastic indications, by 6 surgeons, in our tertiary referral centre, between 2005–2014. Patient demographics and relevant clinical details were determined from notes. The most common indications for the use of EPRs included infection (n=40), peri-prosthetic fracture (n=12) and failed osteosynthesis of proximal femoral fractures/complex trauma (n=11). Outcome measures included complication and re-operation rates, implant survival and assessment of functional outcome using the Oxford-Hip-Score (OHS). The mean age at surgery was 69 years and mean follow-up was 4 (0 – 11) years. The mean number of previous hip operations was 2.4 (range: 0 – 17). Twenty-five patients sustained a complication (31%), the most common being infection (n=9) and dislocation (n=4). By follow-up, further surgery was required in 18 (22%) hips, 9 of which were EPR revisions. 5-yr implant survivorship was 87% (95%CI: 76 – 98%). Mean OHS was 28 (range: 4 – 48). Inferior survival and outcome were seen in EPRs performed for the treatment of infection. Infection eradication was achieved in 34/41 with the index EPR procedure and in 40/41 hips by follow-up. Limb salvage was achieved in all cases and acceptable complication- and re-operation rates were seen. EPRs for periprosthetic fractures and failed osteosynthesis had best outcome. We recommend the continued use of proximal femur EPR in complex revision surgery.
The use of endoprosthesis implants is frequent for tumours involving the proximal third of the femur and not amenable to primary arthroplasty or internal fixation. In this population, these implants are preferentially cemented given poor bone quality associated with systemic diseases and treatments. Loosening is a common complication of these implants that have been linked to poor bone quality, type of implants and importantly cementing technique. Thus, these techniques vary between different surgeons and based mainly on previous experience. One of the most successful cementing techniques in the arthroplasty literature is the French paradox. This technique involves removing the cancellous bone of the proximal femoral metaphysis and selects the largest stem to tightly fit the created cavity delineated by cortical bone. Cementing the implant results in a very thin cement layer that fills the inconsistent gaps between the metal and the bone. To our knowledge, no previous report exists in the literature assessing loosening in
Abstract. Background. Atypical femur fracture (AFF) is a well known complication of Bisphosphonate therapy. Due to prolonged suppression of bone re-modelling in these fractures, surgical complications are difficult to manage. The aim of this study was to analyze the causes of surgical complications in AFF fixations and provide algorithm for management. Method. In this retrospective 10-year study (2010–2020), we identified patients surgically treated for AFF. We included patients who underwent revision surgery for any cause. Data collection included demographics, surgical complications, details of revision surgery and time to union. Result. Out of 57 patients who were operated for AFF, 17 underwent revision fixation. The average age was 69 with only 2 males. Around two-third (64%) were sub-trochanteric fractures and method of fixation in 64% cases was intra-medullary nail. The most common complication was non-union (12), followed by stress fracture and infection in 3 and 2 cases respectively. In most cases inadequate reduction and sub-optimal fixation was perceived as cause of failure except two cases which got infected. Revision fixation in all cases included improved bone contact (non-union site osteotomy), use of bone morphogenic proteins and improved fixation with augmentation device (either nail or plate). Follow up at 1 year showed fracture union in 12 cases, remaining 5 revision fixations failed, 3 of which were managed with
Custom-made partial pelvis replacements (PPRs) are increasingly used in the reconstruction of large acetabular defects and have mainly been designed using a triflange approach, requiring extensive soft-tissue dissection. The monoflange design, where primary intramedullary fixation within the ilium combined with a monoflange for rotational stability, was anticipated to overcome this obstacle. The aim of this study was to evaluate the design with regard to functional outcome, complications, and acetabular reconstruction. Between 2014 and 2023, 79 patients with a mean follow-up of 33 months (SD 22; 9 to 103) were included. Functional outcome was measured using the Harris Hip Score and EuroQol five-dimension questionnaire (EQ-5D). PPR revisions were defined as an endpoint, and subgroups were analyzed to determine risk factors.Aims
Methods
Femoral periprosthetic fractures are rising in incidence. Their management is complex and carries a high associated mortality. Unlike native hip fractures, there are no guidelines advising on time to theatre in this group. We aim to determine whether delaying surgical intervention influences morbidity or mortality in femoral periprosthetic fractures. We identified all periprosthetic fractures around a hip or knee arthroplasty from our prospectively collated database between 2012 and 2021. Patients were categorized into early or delayed intervention based on time from admission to surgery (early = ≤ 36 hours, delayed > 36 hours). Patient demographics, existing implants, Unified Classification System fracture subtype, acute medical issues on admission, preoperative haemoglobin, blood transfusion requirement, and length of hospital stay were identified for all patients. Complication and mortality rates were compared between groups.Aims
Methods
The use of megaprostheses is accompanied with periprosthetic infection in up to 15% of cases. Among metals with antimicrobial activity, silver has raised the interest of investigators because of its good antimicrobial activity. The aim of this study was to determine the infection rate of silver-coated megaprostheses in comparision to uncoated titanium prostheses. We prospectively identified 40 patients who were treated with a silver-coated proximal femur (n=17) or proximal tibia (n=23) replacement (Mutars. ®. , Implantcast, Germany). Patients with a silver-coated tumor endoprosthesis were compared with 74 (proximal
Introduction: Allograft-Prosthesis Composite represents a reliable option for