Advertisement for orthosearch.org.uk
Results 1 - 20 of 294
Results per page:

Background. In our pursuit of surgical accuracy and precision we often neglect to evaluate our results objectively. With the use of Computerised Tomography (CT) in pre-operative planning we can use the same technology in order to evaluate surgical accuracy. Hypothesis. The use of Patient Specific Instrumentation (CT based) produces an accurate intra operative guide for precision cutting in knee arthroplasty. Method. A prospective study using Patient Specific Instrumentation (customized cutting blocks) was performed on 35 patients. The small cohort value is due to the high costs of post-operative CT. A CT based software was used to evaluate the pre-operative knee alignment. Surgery was planned and verified on a web based programme with the use of 3D models. Cutting blocks were custom made and used as intra operative guide to make the relevant cuts. Pre and post-operative CT scans were compared for AP and lateral alignment, femoral external rotation and flexion and tibial slope. Knee Society scores were also used to evaluate the clinical outcome. Results. The values for AP and lateral limb alignment, femoral external rotation and flexion were the same as the pre-operative values with no significant deviation (maximum 2 degree difference). The posterior tibial slope was the only value that showed significant deviation from the pre-planned values. Conclusion. There was a significant difference for the posterior tibial slope but otherwise we found no difference in pre and post-operative limb alignment measurements. Pre-operative planning with the use of CT based customised cutting blocks is a reliable and accurate option to obtain optimal alignment and prosthetic orientation in total knee arthroplasty. NO DISCLOSURES


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 82 - 82
23 Feb 2023
Rossignol SL Boekel P Rikard-Bell M Grant A Brandon B Doma K O'Callaghan W Wilkinson M Morse L
Full Access

Glenoid baseplate positioning for reverse total shoulder replacements (rTSR) is key for stability and longevity. 3D planning and image-derived instrumentation (IDI) are techniques for improving implant placement accuracy. This is a single-blinded randomised controlled trial comparing 3D planning with IDI jigs versus 3D planning with conventional instrumentation. Eligible patients were enrolled and had 3D pre-operative planning. They were randomised to either IDI or conventional instrumentation; then underwent their rTSR. 6 weeks post operatively, a CT scan was performed and blinded assessors measured the accuracy of glenoid baseplate position relative to the pre-operative plan. 47 patients were included: 24 with IDI and 23 with conventional instrumentation. The IDI group were more likely to have a guidewire placement within 2mm of the preoperative plan in the superior/inferior plane when compared to the conventional group (p=0.01). The IDI group had a smaller degree of error when the native glenoid retroversion was >10° (p=0.047) when compared to the conventional group. All other parameters (inclination, anterior/posterior plane, glenoids with retroversion <10°) showed no significant difference between the two groups. Both IDI and conventional methods for rTSA placement are very accurate. However, IDI is more accurate for complex glenoid morphology and placement in the superior-inferior plane. Clinically, these two parameters are important and may prevent long term complications of scapular notching or glenoid baseplate loosening. Image-derived instrumentation (IDI) is significantly more accurate in glenoid component placement in the superior/inferior plane compared to conventional instrumentation when using 3D pre-operative planning. Additionally, in complex glenoid morphologies where the native retroversion is >10°, IDI has improved accuracy in glenoid placement compared to conventional instrumentation. IDI is an accurate method for glenoid guidewire and component placement in rTSA


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 87 - 87
1 Jul 2022
Rajput V Fontalis A Plastow R Kayani B Giebaly D Hansejee S Magan A Haddad F
Full Access

Abstract. Introduction. Coronal plane alignment of the knee (CPAK) classification utilises the native arithmetic hip-knee alignment to calculate the constitutional limb alignment and joint line obliquity which is important in pre-operative planning. The objective of this study was to compare the accuracy and reproducibility of measuring the lower limb constitutional alignment with the traditional long leg radiographs versus computed tomography (CT) used for pre-operative planning in robotic-arm assisted TKA. Methods. Digital long leg radiographs and pre-operative CT scan plans of 42 patients (46 knees) with osteoarthritis undergoing robotic-arm assisted total knee replacement were analysed. The constitutional alignment was established by measuring the medial proximal tibial angle (mPTA), lateral distal femoral angle (LDFA), weight bearing hip knee alignment (WBHKA), arithmetic hip knee alignment (aHKA) and joint line obliquity (JLO). Furthermore, the Coronal Plane Alignment of the Knee (CPAK) classification was utilised to classify the patients based on their coronal knee alignment phenotype. Results. Mean age of the patients was 66 years (SD 9) and mean BMI 31.2 (SD 3.9). There were 27 left and 19 right sided surgeries. The Pearson's corelation coefficient was 0.722 (p=0.008) for WBHKA; 0.729 (p<0.001) for MPTA; 0.618 (p=0.14) for aHKA; 0.502 (p= 0.04) for LDFA and 0.305 (p=0.234) for JLO. CPAK classification was concordant for 53% study participants between the two groups. Conclusion. Three-dimensional CT-based modelling with computer software more accurately predicts constitutional limb alignment and JLO as defined by the CPAK classification compared to plain long-leg radiographs in pre-operative planning of total knee arthroplasty


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_6 | Pages 20 - 20
1 May 2021
Sundarapandian R Nesbitt P Khunda A
Full Access

Introduction. The most challenging aspect in rotational deformity correction is translating the pre-operative plan to an accurate intra-operative correction. Landmarks away from the osteotomy site are typically employed at pre-operative planning and this can render inadequate correction. Our proposed technique of pre-operative planning using CT scan and leg length radiographs can translate to accurate intra-operative correction. Materials and Methods. A circle was superimposed at osteotomy site with its centre serving as the centre of correction of rotation. Medio-lateral distance at osteotomy site measured and used as diameter of the circle. Circumference of the circle was calculated by multiplying diameter with Pi and used in the below formula to obtain accurate de-rotation distance;. Derotation distance = (Circumference/360) × correction value for desired ante-version. The exact site of osteotomy was measured in theatre under C-arm and exposed. Derotation distance was marked on the surface of bone as point A and point B with a flexible ruler. Osteotomy performed with saw and derotation was done till point A and point B were co-linear. Derotation distance obtained using this technique is specific for the site of chosen osteotomy and implies a specific degree of correction for every millimeter derotated. Distal femur was the chosen site of osteotomy if there was associated patellar instability and proximal femur if there was no patellar instability. Results. We have used the above technique to successfully correct rotational malalignment of femur and tibia in three patients thus far. The foot progression angle improved in all patients following surgery. One patient had post-operative CT scan of the hips which showed accurate reduction of ante-version. Conclusions. Our new technique of rotational deformity correction is simple and reproducible using commonly available tools as CT scan and leg length radiographs. This technique effectively translates the pre-operative plan to accurate intra-operative correction of rotational deformity


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 9 - 9
1 Jul 2022
Fleming T Torrie A Murphy T Dodds A Engelke D Curwen C Gosal H Pegrum J
Full Access

Abstract. INTRODUCTION. COVID-19 reduced availability of cross-sectional imaging, prompting the need to clinically justify pre-operative computed tomography (CT) in tibial plateau fractures (TPF). The study purpose was to establish to what extent does a CT alter the pre-operative plan in TPF compared to radiographs. There is a current paucity of evidence assessing its impact on surgical planning. METHODOLOGY. 50 consecutive TPF with preoperative CT were assessed by 4 consultant surgeons. Anonymised radiographs were assessed defining the column classification, planned setup, approach, and fixation technique. At a 1-month interval, randomised matched CT scans were assessed and the same data collected. A tibial plateau disruption score (TPDS) was derived for all 4 quadrants (no injury=0,split=1,split/depression=2 and depression=3). Radiograph and CT TPDS were assessed using an unpaired T-test. RESULTS. 26 female and 24 male patients, mean age 50.3, were included. Mean TPDS on radiographs and CT scans were 2.77 and 3.17 respectively. A significant higher net CT TPDS was observed of 0.4 (95%CI 0.10-0.71)[P=0.0093]. Both radiograph and CT TPDS ANOVA were significant (P<0.0001), showing high intraobserver variability for TPF classification. Fracture apex requiring fixation changed in 34% of cases between the radiographs and CT, whilst set-up and surgical approach changed in 27% and 28.5% of cases respectively. All surgeons agreed no CT was required in only 11 out of 50 cases. CONCLUSION. CT scanning in TPF significantly affects the classification, setup, approach and fixation technique when compared to radiographs alone and can justifiably be requested as part of pre-operative planning


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 20 - 20
1 Jul 2020
Ge S Barimani B Epure L Aoude A Luo L Volesky M Chaytor RE
Full Access

Recent innovations in total ankle replacement (TAR) have led to improvements in implant survivorship, accuracy of component positioning and sizing, and patient outcomes. CT-generated pre-operative plans and cutting guides show promising results in terms of placement enhancement and reproducibility in clinical studies. The purpose of this study was to determine the accuracy of 1) implant sizes used and 2) alignment corrections obtained intraoperatively using the cutting guides provided, compared to what was predicted in the CT generated pre-operative plans. This is a retrospective study looking at 36 patients who underwent total ankle arthroplasty using a CT generated pre-operative planning system between July 2015 and December 2017. Personalized pre-operative planning data was obtained from the implant company. Two evaluators took measurements of the angle corrected using pre- and post-operative weight bearing ankle AP X-rays. All patients had a minimum three-month follow-up with weightbearing postoperative radiographs. The actual correction calculated from the radiographic assessment was compared with the predicted angles obtained from pre-operative plans. The predicted and predicted alternative component sizes and actual sizes used were also compared. If either a predicted or predicted alternative size was implanted, we considered it to be accurate. Average age for all patients was 64 years (range 40–83), with a body mass index of 28.2 ± 5.6. All surgeries were performed by two foot and ankle surgeons. The average total surgical time was 110 ± 23 minutes. Pre-operative alignment ranged from 36.7 degrees valgus to 20 degrees varus. Average predicted coronal alignment correction was 0.8 degrees varus ± 9.3 degrees (range, 18.2 degrees valgus to 29 degrees varus) and average correction obtained was 2.1 degrees valgus ± 11.1 degrees. Average post-op alignment was consistently within 5 degrees of neutral. There were no significant differences between the predicted alignments and the postoperative weightbearing alignments. The predicted tibia implant size was accurate in all cases. The predicted sizes were less accurate for talar implants and predicted the actual talar implant size used in 66% of cases. In all cases of predicted talar size mismatch, surgical plans predicted 1 implant size larger than used. Preliminary analyses of our data is comparable to previous studies looking at similar outcomes. However, our study had higher pre-operative deformities. Despite that, post-op alignments were consistently within 5 degress of neutral with no significant difference between the predicted and actual corrections. Tibial implant sizes are highly accurate while talar implant sizes had a trend of being one size smaller than predicted. Moreover, this effect seems to be more pronounced in the earlier cases likely reflective of increasing surgeon comfort with the implant with each subsequent case. These results confirm that pre-operative cutting guides are indeed helpful in intra-operative implant selection and positioning, however, there is still some room for innovation


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 99 - 99
1 Apr 2019
Wahrburg J Gieseler O Roth H
Full Access

Total hip replacement procedures are among the most frequent surgical interventions in all industrialized countries. Although it is a routine operationliterature reports that important parameters regarding for example cup orientation and leg length discrepancy often turn out to be not satisfying after surgery. This paper presents a novel concept to improve the reproducibility and accuracy for implantation of cup and stem prosthesis at exactly the desired locations. Existing computer- based commercial products either offer software solutions for just pre-operative planning, or imageless navigation systems that are only used during surgery in the operating theatre. The innovation of our approach is based on an integrated computer-assisted solution that combines pre-operative planning and intra-operative navigation to support THR procedures. The software for pre-operative planning can process both, 3D CT images and standard 2D x-ray images. A custom-built navigation system using optical 3D localizing technology has been developed to transfer planning results to the OR. The main objective of our approach is to implant the artificial joint in a way to restore the natural anatomy of the joint before surgery as close as possible, or with exactly planned modifications. In particular, cup inclination, cumulative anteversion of cup and stem, CCD angle and lateral offset, centre of rotation, leg length discrepancy, and joint range of motion are considered. It is not necessary to determine numerical values for all of these parameters because our approach uses a unique procedure to record the natural anatomical situation by combining pre-operative planning and intra-operative navigation, and subsequently supports implantation of the prosthesis components by surgical navigation in order to restore this situation. In case planar 2D x-ray images are used for pre-operative planning accurate scaling of these images is a prerequisite for exact determination of relevant parameters. The patient-specific scaling factor depends on the distance of the hip joint rotation centre from the x-ray detector or film. We have designed a low-cost localization system to be mounted close to the x-ray apparatus. It localizes the 3D position of the rotation centre by small motions of the leg and eliminates uncertainties of conventional methods that are caused by improper positioning of a calibration body. Easy and robust setup and application have been key objectives for the development of our custom-built navigation system. Acquisition of intraoperative parameters for example includes the determination of the acetabular centre axis by localizing selected landmarks at the acetabular rim. Intra-operative parameters are combined with pre-operative parameters without needing sophisticated matching procedures with the pre-operative images. A preliminary surgical workflow that will be detailed in the conference presentation has been designed for evaluation of the concept using sawbones models. Based on the promising results of our laboratory tests we have started to prepare first clinical experiments in close cooperation with surgeons


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 66 - 66
2 Jan 2024
Burssens A
Full Access

Osteotomies in the musculoskeletal system are joint preserving procedures to correct the alignment of the patient. In the lower limb, most of the pre-operative planning is performed on full leg weightbearing radiographs. However, these images contain a 2-dimensional projection of a 3-dimensional deformity, lack a clear visualization of the joint surface and are prone to rotational errors during patient positioning. Weightbearing CT imaging has demonstrated to overcome these shortcomings during the first applications of this device at level of the foot and ankle. Recent advances allow to scan the entire lower limb and novel applications at the level of the knee and hip are on the rise. Here, we will demonstrated the current techniques and 3-dimensional measurements used in supra- and inframalleolar osteotomies around the ankle. Several of these techniques will be transposed to other parts in the lower limb to spark future studies in this field


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 37 - 37
1 Jun 2023
Elsheikh A Elazazy M Elkaramany M
Full Access

Introduction. Osteomyelitis is a challenge in diagnosis and treatment. 18F-FDG PET-CT provides a non-invasive tool for diagnosing and localizing osteomyelitis with a sensitivity reaching 94% and specificity reaching 100%. We aimed to assess the agreement in identifying the geographic area of infected bone and planned resection on plain X-ray versus 18F-FDG PET-CT. Materials & Methods. Clinical photos and X-rays of ten osteomyelitis patients were shown to ten consultant surgeons; they were asked to draw the area of infection and extent of planned surgical debridement; data will be compared to 18F-FDG PET-CT results. Results. We tested the agreement between the surgeons in every parameter. Regarding height, there was poor agreement between surgeons. Regarding perimeter, the ten surgeons showed low-moderate agreement. The ten surgeons showed a low-moderate agreement for circularity. Results document the variability of assessment and judgement based on plain X-rays. In comparison to PET-CT, All parameters were significantly different in favour of 18F-FDG PET-CT over X-ray (P < 0.001). Conclusions. 18F FDG PET-CT provides a three-dimensional tool for localizing the exact location of the infected bone and differentiating it from the normal bone. Thus, it could be beneficial in precise pre-operative planning and surgical debridement of chronic osteomyelitis


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_17 | Pages 9 - 9
11 Oct 2024
Zace P Maas Z McIntyre R Khan Z Bailey O
Full Access

Increasing the accuracy of information provided through X-Rays maximises pre-operative planning. Aim of this project is to determine the necessity of calibration probes that would improve the accuracy of pre-operative templating. This is a retrospective study involving leg length and pelvis X-Rays performed across the NHS Lanarkshire from 01/03/2023 until 31/04/2024. A total of 87 leg length X-Rays were identified, 18 had a calibration probe present. Leg length was measured on each and the X-Rays were calibrated against the existing probe. In 66.7% of cases there was a major leg length discrepancy of over 2cm between the pre-calibrated and post-calibrated X-Rays. Pelvic X-Rays of 80 patients that underwent total hip replacement were reviewed. Preoperative templating was compared to the implants inserted. An average of 1.94 discrepancy in the size of the acetabular implant was identified whilst in 30 cases the size of the femoral stem was incorrect by at least 1 size. Magnification of 119.7% on X-Rays was found to provide the most accurate templating. Seventy seven cases of pelvic X-Rays before and after hip hemiarthroplasty were also reviewed. The implant head was templated incorrectly in 74% of cases and the stem in 51%. It was identified that pelvic X-Ray magnification of 121.7% would provide the most accurate results. X-Rays with no calibration probes provide inaccurate measurements leading to faulty preoperative planning. Standardised use of a calibration sphere is strongly suggested and whenever that is not available, we suggest magnification of 121%


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 34 - 34
7 Aug 2023
Afzal I Radha S Mitchell P
Full Access

Abstract. Multidisciplinary team (MDT) meetings in orthopaedic surgery are evolving. The goals include patient optimisation, surgical planning and discharge arrangements, individually on a patient specific basis. In line with British Association Surgery of the Knee and GIRFT guidelines, we report our regional experience on the implementation and evolution of our regional Revision Knee Arthroplasty MDT. We undertook a retrospective review of the process, cases discussed and quality assurance conducted in the weekly MDT. Since implementation of the MDT meeting in January 2019, 550 patients with painful joint replacements have been discussed. In May 2021, we formalised our ‘terms of reference’ and ‘standard operating procedures’ which are adhered to by the consultants operating within the network, all of whom attend the meeting. A proforma has been developed and is completed for all cases capturing all pertinent information. All cases are graded according to R1, R2, or R3 complexity scale. Since its inception, the MDT has looked at all post-operative imaging, we now describe a new classification system for grading the appearances. Confirmation of the pre-operative plan and actual surgical intervention is reviewed and audited. In addition, confirmation of indication of revision at the time of operation is reviewed and validated for accuracy with benefits to the unit, individual surgeon and the NJR. In conclusion, the implementation of the revision MDT facilitating pre-operative revision arthroplasty discussion and post-operative quality assurance processes enable surgeons to educate, reflect on their practice and ensure that the highest standards of care are being provided


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 65 - 65
1 Aug 2020
Ekhtiari S Shah A Levesque J Williams D Yan J Thornley P
Full Access

Three-dimensional (3D) printing has become more frequently used in surgical specialties in recent years. Orthopaedic surgery is particularly well-suited to 3D printing applications, and thus has seen a variety of uses for this technology. These uses include pre-operative planning, patient-specific instrumentation (PSI), and patient-specific implant production. As with any new technology, it is important to assess the clinical impact, if any, of three-dimensional printing. The purpose of this review was to answer the following questions: . What are the current clinical uses of 3D printing in orthopaedic surgery?. Does the use of 3D printing have an effect on peri-operative outcomes?. Four electronic databases (Embase, MEDLINE, PubMed, Web of Science) were searched for Articles discussing clinical applications of 3D printing in orthopaedics up to November 13, 2018. Titles, abstracts, and full texts were screened in duplicate and data was abstracted. Descriptive analysis was performed for all studies. A meta-analysis was performed among eligible studies to compare estimated blood loss (EBL), operative time, and fluoroscopy use between 3D printing cases and controls. Study quality was assessed using the Methodological Index for Non-Randomized Studies (MINORS) criteria for non-randomized studies and the Cochrane Risk of Bias Tool for randomized controlled trials (RCTs). This review was prospectively registered on PROSPERO (Registration ID: CRD42018099144). One-hundred and eight studies were included, published between 2012 and 2018. A total of 2328 patients were included in these studies, and 1558 patients were treated using 3D printing technology. The mean age of patients, where reported, was 47 years old (range 3 to 90). Three-dimensional printing was most commonly reported in trauma (N = 41) and oncology (N = 22). Pre-operative planning was the most common use of 3D printing (N = 63), followed by final implants (N = 32) and PSI (N = 22). Titanium was the most commonly used 3D printing material (16 studies, 27.1%). A wide range of costs were reported for 3D printing applications, ranging from “less than $10” to $20,000. The mean MINORS score for non-randomized studies was 8.3/16 for non-comparative studies (N = 78), and 17.7/24 for non-randomized comparative studies (N = 19). Among RCTs, the most commonly identified sources of bias were for performance and detection biases. Three-dimensional printing resulted in a statistically significant decrease in mean operative time (−15.6 mins, p < .00001), mean EBL (−35.9 mL, p<.00001), and mean fluoroscopy shots (−3.5 shots, p < .00001) in 3D printing patients compared to controls. The uses of 3D printing in orthopaedic surgery are growing rapidly, with its use being most common in trauma and oncology. Pre-operative planning is the most common use of 3D printing in orthopaedics. The use of 3D printing significantly reduces EBL, operative time, and fluoroscopy use compared to controls. Future research is needed to confirm and clarify the magnitude of these effects


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_10 | Pages 113 - 113
1 Jun 2018
Gustke K
Full Access

Pre-operative planning in revision total knee replacement is important to simplify the surgery for the implant representative, operating room personnel and the surgeon. Revision knee arthroplasty is performed for many different reasons and of variable complexity. Many implant options can be considered including cemented and cementless primary and stemmed revision tibial and femoral components, with posterior cruciate retention or resection, and either with no constraint, varus/valgus constraint, or with rotating hinge bearings. One may also need femoral and tibial spacers, metaphyseal augments, or bulk allograft. It is important to pre-operatively determine which of these implants you may need. If you schedule a revision total knee and ask the implant representative to “bring everything you've got, just in case,” they will have to bring a truck full of instruments and implants. The first step of pre-operative planning is to determine how much implant constraint will be needed. Survivorship of revision total knees with modern varus/valgus constrained or rotating hinge implants are not that unacceptable. Ideally to enhance longevity, the least constraint needed should be used. This requires determination of the status of the ligaments. Varus and valgus stress is applied to the knee in near full extension, mid-flexion, and ninety degrees of flexion. If instability of the knee is noted, then radiographs are reviewed to determine if component malposition or malalignment is the reason for the collateral ligament laxity. If radiographs don't show a reason, then have additional constraint available in case the knee can't be balanced with proper component position and ligament balancing. In cases other than simple revisions, the posterior cruciate ligament is usually inadequate or needs to be resected to balance the knee. Substitution for the posterior cruciate ligament is usually needed for most revisions. The second step of pre-operative planning is to review radiographs to determine the amount and location of any bone loss. Osteolysis induced bone loss is usually worse than seen on plain radiographs. If unsure, a CT scan can be of help. The presence of significant bone loss contraindicates the use of primary components and mandates the need for stemmed implants. Larger defects may warrant having metallic augments or bulk graft present. Most revision knee implants can be conservatively metaphyseal cemented with diaphyseal engaging press-fit stems. The third step of pre-operative planning is to be familiar with what implants are present. Occasionally, one may not need to revise components that are stable and well aligned. Having compatible components available may simplify the surgery. Excellent pre-operative planning will minimise the need to bring in an excessive number of instruments and implants. It will help assure that the patient has a stable revision knee and simplify the surgery for all participants


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 82 - 82
7 Aug 2023
Jones R Phillips J Panteli M
Full Access

Abstract. Introduction. Total joint arthroplasty (TJA) is one of the commonest and most successful orthopaedic procedures, used for the management of end-stage arthritis. With the recent introduction of robotic assisted joint replacement, Computed Tomography (CT) has become part of required pre-operative planning. The aim of this study is to quantify and characterise incidental CT findings, their clinical significance, and their effect on planned joint arthroplasty. Methodology. All consecutive patients undergoing an elective TJR (hip or knee arthroplasty) were retrospectively identified, over a 3-year period (December 2019 and December 2022). Data documented and analysed included patient demographics, type of joint arthroplasty, CT findings, their clinical significance, as well as potential delays to the planned arthroplasty because of these findings and subsequent further investigation. Results. A total of 624 patients (637 studies, 323 (51.8%) female, 301 (48.2%) male) were identified of which 163 (25.6%) showed incidental findings within the long bones or pelvis. Of these 52 (8.2%) were significant, potentially requiring further management, 32 (5.0%) represented potential malignancy and 4 (0.6%) resulted in a new cancer diagnosis. Conclusion. It is not currently national standard practice to report planning CT imaging as it is deemed an unnecessary expense and burden on radiology services. Within the study cohort 52 (8.2%) of patients had a significant incidental finding that required further investigation or management and 4 (0.6%) had a previously undiagnosed malignancy. In order to avoid the inevitability of a missed malignancy on a planning CT, we must advocate for formal reports in all cases


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 17 - 17
7 Nov 2023
Rachuene PA Dey R Motchon YD Sivarasu S Stephen R
Full Access

In patients with shoulder arthritis, the ability to accurately determine glenoid morphological alterations affects the outcomes of shoulder arthroplasty surgery significantly. This study was conducted to determine whether there is a correlation between scapular and glenoid morphometric components. Existence of such a correlation may help surgeons accurately estimate glenoid bone loss during pre-operative planning. The dimensions and geometric relationships of the scapula, scapula apophysis and glenoid were assessed using CT scan images of 37 South African and 40 Chinese cadavers. Various anatomical landmarks were marked on the 77 scapulae and a custom script was developed to perform the measurements. Intra-cohort correlation and inter-cohort differences were statistically analysed using IBM SPSS v28. The condition for statistical significance was p<0.05. The glenoid width and height were found to be significantly (p<0.05) correlated with superior glenoid to acromion tip distance, scapula height, acromion tip to acromion angle distance, acromion width, scapula width, and coracoid width, in both the cohorts. While anterior glenoid to coracoid tip distance was found to be significantly correlated to glenoid height and width in the South African cohort, it was only significantly correlated to glenoid height in the Chinese cohort. Significant (p<0.05) inter-cohort differences were observed for coracoid height, coracoid width, glenoid width, scapula width, superior glenoid to acromion tip distance, and anterior glenoid to coracoid tip distance. This study found correlations between the scapula apophyseal and glenoid measurements in the population groups studied. These morphometric correlations can be used to estimate the quantity of bone loss in shoulder arthroplasty patients


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 60 - 60
4 Apr 2023
MacLeod A Mandalia V Mathews J Toms A Gill H
Full Access

High tibial osteotomy (HTO) is an effective surgical treatment for isolated medial compartment knee osteoarthritis; however, widespread adoption is limited due to difficulty in achieving the planned correction, and patient dissatisfaction due to soft tissue irritation. A new HTO system – Tailored Osteotomy Knee Alignment (TOKA®, 3D Metal Printing Ltd, Bath, UK) could potentially address these barriers having a custom titanium plate and titanium surgical guides featuring a unique mechanism for precise osteotomy opening as well as saw cutting and drilling guides. The aim of this study was to assess the accuracy of this novel HTO system using cadaveric specimens; a preclinical testing stage ahead of first-in-human surgery according to the ‘IDEAL-D’ framework for device innovation. Local ethics committee approval was obtained. The novel opening wedge HTO procedure was performed on eight cadaver leg specimens. Whole lower limb CT scans pre- and post-operatively provided geometrical assessment quantifying the discrepancy between pre-planned and post-operative measurements for key variables: the gap opening angle and the patient specific surgical instrumentation positioning and rotation - assessed using the implanted plate. The average discrepancy between the pre-operative plan and the post-operative osteotomy correction angle was: 0.0 ± 0.2°. The R2 value for the regression correlation was 0.95. The average error in implant positioning was −0.4 ± 4.3 mm, −2.6 ± 3.4 mm and 3.1 ± 1.7° vertically, horizontally, and rotationally respectively. This novel HTO surgery has greater accuracy and smaller variability in correction angle achieved compared to that reported for conventional or other patient specific methods with published data available. This system could potentially improve the accuracy and reliability of osteotomy correction angles achieved surgically


Accurate evaluation of lower limb coronal alignment is essential for effective pre-operative planning of knee arthroplasty. Weightbearing hip-knee-ankle (HKA) radiographs are considered the gold standard. Mako SmartRobotics uses CT-based navigation to provide intra-operative data on lower limb coronal alignment during robotic assisted knee arthroplasty. This study aimed to compare the correlation between the two methods in assessing coronal plane alignment. Patients undergoing Mako partial (PKA) or total knee arthroplasty (TKA) were identified from our hospital database. The hospital PACS system was used to measure pre-operative coronal plane alignment on HKA radiographs. This data was correlated to the intraoperative deformity assessment during Mako PKA and TKA surgery. 443 consecutive Mako knee arthroplasties were performed between November 2019 and December 2021. Weightbearing HKA radiographs were done in 56% of cases. Data for intraoperative coronal plane alignment was available for 414 patients. 378 knees were aligned in varus, and 36 in valgus. Mean varus deformity was 7.46° (SD 3.89) on HKA vs 7.13° (SD 3.56) on Mako intraoperative assessment, with a moderate correlation (R= 0.50, p<0.0001). Intraoperative varus deformity of 0-4° correlated to HKA measured varus (within 3°) in 60% of cases, compared to 28% for 5-9°, 17% for 10-14°, and in no cases with >15° deformity. Mean valgus deformity was 6.44° (SD 4.68) on HKA vs 4.75° (SD 3.79) for Mako, with poor correlation (R=0.18, p=0.38). In this series, the correlation between weightbearing HKA radiographs and intraoperative alignment assessment using Mako SmartRobotics appears to be poor, with greater deformities having poorer correlation


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_8 | Pages 7 - 7
10 May 2024
Zaidi F Goplen CM Fitz-Gerald C Bolam SM Hanlon M Munro J Monk AP
Full Access

Introduction. Recent technological advancements have led to the introduction of robotic-assisted total knee arthroplasty to improve the accuracy and precision of bony resections and implant position. However, the in vivo accuracy is not widely reported. The primary objective of this study is to determine the accuracy and precision of a cut block positioning robotic arm. Method. Seventy-seven patients underwent total knee arthroplasty with various workflows and alignment targets by three arthroplasty-trained surgeons with previous experience using the ROSA® Knee System. Accuracy and precision were determined by measuring the difference between various workflow time points, including the final pre-operative plan, validated resection angle, and post-operative radiographs. The mean difference between the measurements determined accuracy, and the standard deviation represented precision. Results. The accuracy and precision for all angles comparing the final planned resection and validated resection angles was 0.90° ± 0.76°. The proportion within 3° ranged from 97.9% to 100%. The accuracy and precision for all angles comparing the final intra- operative plan and post-operative radiographs was 1.95 ± 1.48°. The proportion of patients within 3° was 93.2%, 95.3%, 96.6%, and 71.4% for the distal femur, proximal tibia, femoral flexion, and tibial slope angles when the final intra-operative plan was compared to post-operative radiographs. No patients had a postoperative complication requiring revision at the final follow-up. Conclusions. This study demonstrates that the ROSA Knee System has accurate and precise coronal plane resections with few outliers. However, the tibial slope demonstrated decreased accuracy and precision were measured on post-operative short-leg lateral radiographs with this platform


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 59 - 59
4 Apr 2023
MacLeod A Roberts S Mandalia V Gill H
Full Access

Conventional proximal tibial osteotomy is a widely successful joint-preserving treatment for osteoarthritis; however, conventional procedures do not adequately control the posterior tibial slope (PTS). Alterations to PTS can affect knee instability, ligament tensioning, knee kinematics, muscle and joint contact forces as well as range of motion. This study primarily aimed to provide a comprehensive investigation of the variables influencing PTS during high tibial osteotomy using a 3D surgical simulation approach. Secondly, it aimed to provide a simple means of implementing the findings in future 3D pre-operative planning and /or clinically. The influence of two key variables: the gap opening angle and the hinge axis orientation on PTS was investigated using three independent approaches: (1) 3D computational simulation using CAD software to perform virtual osteotomy surgery and simulate the post-operative outcome. (2) Derivation of a closed-form mathematical solution using a generalised vector rotation approach (3) Clinical assessment of synthetically generated x-rays of osteoarthritis patients (n=28; REC reference: 17/HRA/0033, RD&E NHS, UK) for comparison against the theoretical/computational approaches. The results from the computational and analytical assessments agreed precisely. For three different opening angles (6°, 9° and 12°) and 7 different hinge axis orientations (from −30° to 30°), the results obtained were identical. A simple analytical solution for the change in PTS, ΔP. s,. based on the hinge axis angle, α, and the osteotomy opening angle, θ, was derived:. ΔP. s. =sin. -1. (sin α sin θ). The clinical assessment demonstrated that the absolute values of PTS, and changes resulting from various osteotomies, matched the results from the two relative prediction methods. This study has demonstrated that PTS is impacted by the hinge axis angle and the extent of the osteotomy opening angle and provided computational evidence and analytical formula for general use


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 36 - 36
2 May 2024
Jones R Phillips J Panteli M
Full Access

Total joint arthroplasty (TJA) is one of the commonest and most successful orthopaedic procedures used for the management of end-stage arthritis. With the recent introduction of robotic-assisted joint replacement, Computed tomography (CT) has become part of required pre-operative planning. The aim of this study is to quantify and characterise incidental CT findings, their clinical significance, and their effect on the planned joint arthroplasty. All consecutive patients undergoing an elective TJA (total joint arthroplasty; hip or knee) were retrospectively identified, over a 4-year period (December 2019 and November 2023). Data documented and analysed included patient demographics, type of joint arthroplasty, CT findings, their clinical significance, as well as potential delays to the planned arthroplasty because of these findings and subsequent further investigation. A total of 987 patients (female: 514 patients (52.1%)) undergoing TJA were identified (THA: 444 patients (45.0%); TKA: 400 patients (40.5%); UKA: 143 patients (14.5%)). Incidental findings within imaged areas were identified in 227 patients (23.0%). Of these findings, 74 (7.5%) were significant, requiring further investigation or management, 40 (4.1%) of which represented potential malignancy and 4 (0.4%) resulting in a new cancer diagnosis. A single patient was found to have an aneurysm requiring urgent vascular intervention. Surgery was delayed for further investigation in 4 patients (0.4%). Significant findings were more frequent in THA patients (THA: 43 (9.7%) TKA/UKA: 31 (5.7%). Within our cohort, 74 (7.5%) patients had significant incidental findings that required further investigations or management, with 4 (0.4%) having a previously undiagnosed malignancy. We strongly advocate that all robotic arthroplasty planning CTs are reviewed and reported by a specialist, to avoid missing undiagnosed malignancies and other significant diagnoses