Advertisement for orthosearch.org.uk
Results 1 - 20 of 255
Results per page:
Bone & Joint Research
Vol. 12, Issue 9 | Pages 559 - 570
14 Sep 2023
Wang Y Li G Ji B Xu B Zhang X Maimaitiyiming A Cao L

Aims. To investigate the optimal thresholds and diagnostic efficacy of commonly used serological and synovial fluid detection indexes for diagnosing periprosthetic joint infection (PJI) in patients who have rheumatoid arthritis (RA). Methods. The data from 348 patients who had RA or osteoarthritis (OA) and had previously undergone a total knee (TKA) and/or a total hip arthroplasty (THA) (including RA-PJI: 60 cases, RA-non-PJI: 80 cases; OA-PJI: 104 cases, OA-non-PJI: 104 cases) were retrospectively analyzed. A receiver operating characteristic curve was used to determine the optimal thresholds of the CRP, ESR, synovial fluid white blood cell count (WBC), and polymorphonuclear neutrophil percentage (PMN%) for diagnosing RA-PJI and OA-PJI. The diagnostic efficacy was evaluated by comparing the area under the curve (AUC) of each index and applying the results of the combined index diagnostic test. Results. For PJI prediction, the results of serological and synovial fluid indexes were different between the RA-PJI and OA-PJI groups. The optimal cutoff value of CRP for diagnosing RA-PJI was 12.5 mg/l, ESR was 39 mm/hour, synovial fluid WBC was 3,654/μl, and PMN% was 65.9%; and those of OA-PJI were 8.2 mg/l, 31 mm/hour, 2,673/μl, and 62.0%, respectively. In the RA-PJI group, the specificity (94.4%), positive predictive value (97.1%), and AUC (0.916) of synovial fluid WBC were higher than those of the other indexes. The optimal cutoff values of synovial fluid WBC and PMN% for diagnosing RA-PJI after THA were significantly higher than those of TKA. The specificity and positive predictive value of the combined index were 100%. Conclusion. Serum inflammatory and synovial fluid indexes can be used for diagnosing RA-PJI, for which synovial fluid WBC is the best detection index. Combining multiple detection indexes can provide a reference basis for the early and accurate diagnosis of RA-PJI. Cite this article: Bone Joint Res 2023;12(9):559–570


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 15 - 15
4 Jun 2024
Jennison T Naveed U Chadwick C Blundell C
Full Access

Introduction. There are nearly 500,000 people with undiagnosed diabetes mellitus in the UK. The incidental finding vascular calcification on plain radiographs in patients with undiagnosed diabetes has the potential to alter patient management in those presenting with pathology. We hypothesised that the presence of vascular calcification on plain radiographs of the foot may predict the diagnosis of diabetes. The primary aim of this case control study was to determine the positive predictive value of vascular calcification to diagnose diabetes. Secondary aims were to determine the odds of having diabetes dependent on other known risk factors for calcification. Methods. A retrospective case control study of 130 diabetic patients were compared to 130 non-diabetic patients that were matched for age and gender. The presence of vascular calcification in anterior, posterior or plantar vessels, and length of calcification were measured on plain radiographs. McNemar's Chi-squared test and positive predictive values were calculated. Conditional logistic regression models were used to estimate the association between calcification and diabetes. Results. 28 patients had type I diabetes and 102 had type II diabetes. The mean age was 58.0 in both groups and 31.5% were females. 89.2% of those with diabetes had calcification present, and 23.1% in those without (p < 0.0001). Calcification in two vessels predicts diabetes with a positive predictive value of 91.2% (95% CI 82.1%–100%). The odds ratio for having diabetes is 78 (95% CI: 7.8 – 784) times higher in a person who has calcification in the blood vessels of their foot than in a person without calcification after adjusting for confounders. Conclusion. This study has demonstrated that vascular calcification in 2 vessels is over 90% predictive of a diagnosis of diabetes. This screening test could be used in future clinics when interpreting radiographs, aiding in the diagnosis of diabetes and altering patient management


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 37 - 37
1 Oct 2022
Lutro O Mo S Leta TH Fenstad AM Tjørhom MB Bruun T Hallan G Furnes O Dale H
Full Access

Aim. In recent years, many studies on revision for infection after arthroplasty have been published. In national arthroplasty registers, revision for infection is defined as surgical debridement, with or without removal or exchange of the entire or parts of the prosthesis due to deep infection, and should be reported to the register immediately after surgery. The diagnosis of infection is made at the surgeon's discretion, based on pre- and perioperative assessment and evaluation, and is not to be corrected to the register based on peroperative bacterial cultures. Due to this lack of validation, the rate of revision for infection will only be an approximation of the true rate of periprosthetic joint infection (PJI). Our aim was to validate the reporting of infection after total hip arthroplasty, and to assess if revisions for infection actually represented true PJI. Methods. We investigated the reported revisions for infection and aseptic loosening after total hip arthroplasty from 12 hospitals, representing one region of the country, reported during the period 2010–2020. The electronic patient charts were investigated for information on surgical treatment, use of antibiotics, biochemistry and microbiology findings. PJI was defined as growth of at least two phenotypically identical microbes in perioperative tissue samples. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy were calculated. Results. 145 revisions for infection and 137 revisions for aseptic loosening were reported. Of the reported infections, there were 141/145 true positives and 4/145 false positives. Of the reported aseptic loosenings, there were 126/137 true negatives and 11/137 false negatives. This gives a positive predictive value of 0.97, negative predictive value of 0.92, sensitivity of 0.93, specificity of 0.97 and accuracy of 0.95. Interpretation. We found the reporting revision for infection after total hip arthroplasty to the national register accurate. There was high correlation between reported revision for infection and PJI. Studies on revision for infection from arthroplasty registers may therefore be considered as reliable as studies of true PJI


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 26 - 26
1 Jul 2022
Michael C Salar O Bayley M Waterson B Toms A Phillips J
Full Access

Abstract. Background. Prosthetic joint infection (PJI) is a significant cause of morbidity and mortality following knee replacement surgery. Identifying the causative agent(s) and their antibiotic sensitivities is critical in determining the choice of treatment methods used and the likelihood of successful eradication. This study aimed to investigate:. Whether biopsy alone was superior to aspiration alone in specificity and sensitivity for diagnosing PJI following knee replacement. Whether biopsy identifies the same microbiological flora as aspiration. Methods. We identified consecutive patients passing through our knee infection Multi-Disciplinary Team meeting between December 2014 and March 2020. Data was collated data retrospectively using electronic records. Statistical analysis was performed using Stata (Timberlake, February 2020). Results. 65 of 100 patients identified had both pre-operative aspiration and biopsy. In 29% of positive patients, biopsy identified new or additional organisms not previously identified by aspiration. Aspiration had a sensitivity of 70%, specificity of 88%, positive predictive value of 90.3% and negative predictive value of 64.7%. Biopsy had a sensitivity of 97.5%, specificity of 88%, positive predictive value of 92.9% and negative predictive value of 95.7%. Conclusion. Biopsy is superior to aspiration in the diagnosis of PJI and can be performed safely and successfully. It identifies organisms when aspiration may be negative and identifies additional microorganisms in a polymicrobial setting not identified by aspiration alone (29% of positive cases). We would recommend, where possible, aspiration and biopsy as routine pre-operative sampling in order to identify all causative agents and their susceptibilities prior to embarking on revision surgery


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 40 - 40
1 Aug 2020
Li A Glaris Z Goetz TJ
Full Access

Physical examination is critical to formation of a differential diagnosis in patients with ulnar-sided wrist pain. Although the specificity and sensitivity of some of those tests have been reported in the literature, the prevalence of positive findings of those provocative maneuvers has not been reported. The aim of the study is to find the prevalence of positive findings of the most commonly performed tests for ulnar sided wrist pain in a population presenting to UE surgeon clinics, and to correlate those findings with wrist arthroscopy findings. Patients with ulnar sided wrist pain were identified from a prospective database of patients presented with wrist pain from September 2014. Prevalence of positive findings for the following tests were gathered: ECU synergy test, ECU instability test (Ice cream and Fly Swatter), Lunotriquetral ballottement, Kleinman shear, triquetrum tenderness, triquetrum compression test, triquetral-hamate tenderness, pisotriquetral shuck test, ulnar fovea test, ulnocarpal impaction (UCI) maneuver, UCI maneuver with fovea pressure (ulnar carpal plus test), piano key sign. A subgroup was then created for those who underwent wrist arthroscopy, and analysis of the sensitivities, the specificities and the predictive values of these provocative tests was carried out with correlation to arthroscopic finding. Prevalence of ECU instability tests was t 1.13% (ice cream scoop) and 1.5% (fly swatter). Lunotriquetral ballottement test's positive findings range from 4.91% (excessive laxity) to 14.34% (pain reproducing symptoms. The Kleinman shear test yielded pain in 13.58% of patients, and instability in only 2.26%. Triquetrum compression test reproduces pain in 32.83% of patients, and triquetral-hamate tenderness reproduced pain in 13.21%. Pisotriquetral grind test yields 15.85% positive findings for pain, and 10.57% for crepitus with radioulnar translation. The ulnar fovea test revealed pain in 69.05% of cases. The UCI maneuver yielded pain in 70.19%. The UCI maneuver plus ulnar fovea test reproduced pain in 80.38% of cases. Finally, the piano key sign yields positive finding in 2.64% of cases. For patients who underwent surgery, sensitivities, specificities and predictive values were calculated based on arthroscopic findings. The lunotriquetral ballottement test has 59.6% sensitivity, 39.6% specificity, 20.3% positive predictive value and 85.4% negative predictive value. The sensitivity of Kleinman test was 62.4%, the specificity was 41.3%, the positive predictive value was 23.5%, and the negative predictive value was 83.2%. The sensitivity of fovea test was 94.3%, the specificity was 82.5%, the positive predictive value was 89.5% and the negative predictive value was 92.3%. The UCI maneuver plus ulnar fovea test has 96.5% sensitivity, 80.7% specificity 86.4% positive predictive value, and 95.3% negative predictive value. Among the provocative tests, the prevalence of positive findings is low in the majority of those maneuvers. The exceptions are the fovea test, the UCI maneuver, and the UCI plus maneuver. With regard to the sensitivity and the specificity of those tests, the current study reproduces the numbers reported in the literature. Of those patients who underwent wrist arthroscopy, the tests are better at predicting at the absence of injury rather than at predicting its presence


Bone & Joint Research
Vol. 12, Issue 2 | Pages 113 - 120
1 Feb 2023
Cai Y Liang J Chen X Zhang G Jing Z Zhang R Lv L Zhang W Dang X

Aims. This study aimed to explore the diagnostic value of synovial fluid neutrophil extracellular traps (SF-NETs) in periprosthetic joint infection (PJI) diagnosis, and compare it with that of microbial culture, serum ESR and CRP, synovial white blood cell (WBC) count, and polymorphonuclear neutrophil percentage (PMN%). Methods. In a single health centre, patients with suspected PJI were enrolled from January 2013 to December 2021. The inclusion criteria were: 1) patients who were suspected to have PJI; 2) patients with complete medical records; and 3) patients from whom sufficient synovial fluid was obtained for microbial culture and NET test. Patients who received revision surgeries due to aseptic failure (AF) were selected as controls. Synovial fluid was collected for microbial culture and SF-WBC, SF-PNM%, and SF-NET detection. The receiver operating characteristic curve (ROC) of synovial NET, WBC, PMN%, and area under the curve (AUC) were obtained; the diagnostic efficacies of these diagnostic indexes were calculated and compared. Results. The levels of SF-NETs in the PJI group were significantly higher than those of the AF group. The AUC of SF-NET was 0.971 (95% confidence interval (CI) 0.903 to 0.996), the sensitivity was 93.48% (95% CI 82.10% to 98.63%), the specificity was 96.43% (95% CI 81.65% to 99.91%), the accuracy was 94.60% (95% CI 86.73% to 98.50%), the positive predictive value was 97.73%, and the negative predictive value was 90%. Further analysis showed that SF-NET could improve the diagnosis of culture-negative PJI, patients with PJI who received antibiotic treatment preoperatively, and fungal PJI. Conclusion. SF-NET is a novel and ideal synovial fluid biomarker for PJI diagnosis, which could improve PJI diagnosis greatly. Cite this article: Bone Joint Res 2023;12(2):113–120


Bone & Joint Open
Vol. 4, Issue 4 | Pages 234 - 240
3 Apr 2023
Poacher AT Froud JLJ Caterson J Crook DL Ramage G Marsh L Poacher G Carpenter EC

Aims. Early detection of developmental dysplasia of the hip (DDH) is associated with improved outcomes of conservative treatment. Therefore, we aimed to evaluate a novel screening programme that included both the primary risk factors of breech presentation and family history, and the secondary risk factors of oligohydramnios and foot deformities. Methods. A five-year prospective registry study investigating every live birth in the study’s catchment area (n = 27,731), all of whom underwent screening for risk factors and examination at the newborn and six- to eight-week neonatal examination and review. DDH was diagnosed using ultrasonography and the Graf classification system, defined as grade IIb or above or rapidly regressing IIa disease (≥4. o. at four weeks follow-up). Multivariate odds ratios were calculated to establish significant association, and risk differences were calculated to provide quantifiable risk increase with DDH, positive predictive value was used as a measure of predictive efficacy. The cost-effectiveness of using these risk factors to predict DDH was evaluated using NHS tariffs (January 2021). Results. The prevalence of DDH that required treatment within our population was 5/1,000 live births. The rate of missed presentation of DDH was 0.43/1000 live births. Breech position, family history, oligohydramnios, and foot deformities demonstrated significant association with DDH (p < 0.0001). The presence of breech presentation increased the risk of DDH by 1.69% (95% confidence interval (CI) 0.93% to 2.45%), family history by 3.57% (95% CI 2.06% to 5.09%), foot deformities by 8.95% (95% CI 4.81% to 13.1%), and oligohydramnios nby 11.6% (95 % CI 3.0% to 19.0%). Primary risk factors family history and breech presentation demonstrated an estimated cost-per-case detection of £6,276 and £11,409, respectively. Oligohydramnios and foot deformities demonstrated a cost-per-case detected less than the cost of primary risk factors of £2,260 and £2,670, respectively. Conclusion. The inclusion of secondary risk factors within a national screening programme was clinically successful as they were more cost and resource-efficient predictors of DDH than primary risk factors, suggesting they should be considered in the national guidance. Cite this article: Bone Jt Open 2023;4(4):234–240


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_15 | Pages 7 - 7
1 Dec 2015
Lange J Pedersen A Troelsen A Søballe K
Full Access

There is an apparent need for easily accessible research data on Periprosthetic hip joint infections (PJI)(1). Administrative discharge registers could be a valuable single-sources for this purpose, and studies originating from such registers have been published(2–4). However, the quality of routinely collected data for administrative purposes may be questionable for use in epidemiological research. The aim of this study was to estimate the positive predictive value of the International Classification of Disease 10th revision (ICD-10) periprosthetic hip joint infection diagnose code T84.5. The study was performed as a cross-sectional study on data extracted from the Danish National Patient Register. Patients with a registration of performed surgical treatment for hip PJI were identified via the ICD-10 code T84.5 (Infection and inflammatory reaction due to internal joint prosthesis) in association with hip-joint associated surgical procedure codes. Medical records of the identified patients (n=283) were verified for the existence of a periprosthetic hip joint infection. Positive predictive values with 95% confidence intervals (95% CI) were calculated. A T84.5 diagnosis code irrespective of the associated surgical procedure code had a positive predictive value of 85 % (95% CI: 80–89). Stratified to T84.5 in combination with an infection-specific surgical procedure code the positive predictive value increased to 86% (95% CI: 80–91), and in combination with a noninfection-specific surgical procedure code decreased to 82% (95% CI: 72–89). This study is the first to evaluate the only discharge diagnose code of prosthesis-related infection in an administrative discharge register. It is apparent, that codes in administrative discharge registers are prone to misclassification on an administrative level, either by wrongful coding by the physician or administrative personal in the registration process. Misclassification must be expected and taken into consideration when using single-source administrative discharge registers for epidemiological research on periprosthetic hip joint infection. We believe that the periprosthetic hip joint infection diagnose code can be of use in single-source register based studies, but preferably should be used in combination with alternate data sources to ensure higher validity(5). This study is funded in part by the Lundbeck foundation Centre for Fast-track Hip and Knee Surgery, Denmark


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 531 - 531
1 Oct 2010
Tanoira I Buttaro M Comba F Marcos L Garrido CP Piccaluga F Rial P Zanotti G
Full Access

Background: Infection diagnosis in THA remains difficult in some cases. Intraoperative analysis of frozen sections is related to the high sensitivity, specificity, positive predictive value, negative predictive value and accuracy. However, it is a technically demanding procedure and is not a universally accepted method. In the present study, we compared interleukin-6 (IL6) serum level with the erythrocyte sedimentation rate (ESR), the level of C-reactive protein (CRP) and the analysis of frozen sections of intraoperative specimens (FS). Materials: Sixty-nine patients with a THA needing a reoperation due to a suspected infection or another aseptic failure were studied. Patients with chronic inflam-matory diseases, antibiotic treatment prior to surgery, Paget’s diseases and immunodeficiency syndromes were excluded from the study. The mean age at the time of the operation was 68 years old (range: 39 to 91). ESR, CRP and the serum level of IL6 were measured in blood samples before surgery. The cut-off levels were: ESR: ≥ 32 mm/hr, CRP: ≥ 3.2 mg/dl and interleukin-6 ≥ 12 pg/ml. Intraoperatively, samples of tissues were taken to be analyzed immediately on FS, to be routinely processed at the moment and to be referred for bacteriological cultures and histological study. Results: Eleven (16%) of the 69 hips were infected. ESR showed a sensitivity of 0.72 (0.41 to 1.00), a specificity of 0.86 (0.76 to 0.95), a positive predictive value of 0.50 (0.22 to 0.77), and a negative predictive value of 0.94 (0.84 to 1.00).CRP showed a sensitivity of 0.72 (0.41 to 1.00), a specificity of 0.91 (0.83 to 0.99), a positive predictive value of 0.61 (0.31 to 0.91), and a negative predictive value of 0.94 (0.87 to 1.00). IL6 showed a sensitivity of 0.36 (0.30 to 0.69), a specificity of 0.94 (0.88 to 1.00), a positive predictive value of 0.57 (0.13 to 1.00), and a negative predictive value of 0.88 (0.80 to 0.97). The evaluation of the FS showed a sensitivity of 0.81 (0.54 to 1.00), a specificity of 0.98 (0.94 to 1.00), a positive predictive value of 0.90 (0.66 to 1.00), and a negative predictive value of 0.96 (0.91 to 1.00).The combination of CRP and IL6 identified all patients with deep infection of the implant and showed a sensitivity of 0.57 (0.13 to 1.00), a specificity of 1.00 (0.99 to 1.00), a positive predictive value of 1.00 (0.87 to 1.00), and a negative predictive value of 0.94 (0.87 to 1.00). Conclusion: In this study, we obtained similar results combining CRP and IL6 as with the analysis of the frozen sections, which has been in the past our first option to determine whether a THA is infected or not. IL6 and CRP may be used as a valuable routine diagnostic tool in revision THA


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 26 - 26
23 Feb 2023
George JS Norquay M Birke O Gibbons P Little D
Full Access

The risk of AVN is high in Unstable Slipped Capital Femoral Epiphysis (SCFE) and the optimal surgical treatment remains controversial. Our AVN rates in severe, unstable SCFE remained unchanged following the introduction of the Modified Dunn Procedure (MDP) and as a result, our practice evolved towards performing an Anterior Open Reduction and Decompression (AOR) in an attempt to potentially reduce the “second hit” phenomenon that may contribute. The aim of this study was to determine the early surgical outcomes in Unstable SCFE following AOR compared to the MDP. All moderate to severe, Loder unstable SCFEs between 2008 and 2022 undergoing either an AOR or MDP were included. AVN was defined as a non-viable post-operative SPECT-CT scan. Eighteen patients who underwent AOR and 100 who underwent MPD were included. There was no significant difference in severity (mean PSA 64 vs 66 degrees, p = 0.641), or delay to surgery (p = 0.973) between each group. There was no significant difference in the AVN rate at 27.8% compared to 24% in the AOR and MDP groups respectively (p = 0.732). The mean operative time in the AOR group was 24 minutes less, however this was not statistically significant (p = 0.084). The post-reduction PSA was 26 degrees (range, 13–39) in the AOR group and 9 degrees (range, -7 to 29) in the MDP group (p<0.001). Intra-operative femoral head monitoring had a lower positive predictive value in the AOR group (71% compared to 90%). Preliminary results suggest the AVN rate is not significantly different following AOR. There is less of an associated learning curve with the AOR, but as anticipated, a less anatomical reduction was achieved in this group. We still feel that there is a role for the MDP in unstable slips with a larger remodelling component


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 45 - 45
22 Nov 2024
Stoddart C Hennessy C Ashworth J Vaz J Alvand A Kendrick B Palmer A Partington K
Full Access

Aim. Prosthetic joint infection (PJI) is assessed using clinical history and examination, imaging studies and laboratory investigations which inform diagnostic tools such as that proposed by the European Bone and Joint Infection Society to determine the probability of infection. Infection is often confirmed by microbiology culture and histology from intraoperative samples, but ideally a diagnosis of infection is made preoperatively to guide management decisions. At our institution, a tertiary referral centre for PJI, ultrasound (US)-guided synovial biopsy is routinely used as an adjunct to preoperative joint aspiration. Our aim was to evaluate the sensitivity and specificity of microbiology and histology results from US-guided synovial biopsy samples when compared to intraoperative samples. Method. In this retrospective study we analysed all prosthetic hip and knee US-guided biopsies performed at our institution over a 5 year period between 2018 and 2022. Microbiology and histology results from preoperative biopsy samples were individually compared to microbiology and histology findings from intraoperative samples. Results. 381 biopsies were performed; 281 knee, 100 hip. US-guided biopsy results showed strong positive predictive values (PPVs) in hip biopsies (microbiology PPV (79.3%), histology PPV (85.7%)) and knee biopsies (microbiology PPV (77%), histology PPV (85%)). Biopsies showed low sensitivity in predicting intraoperative findings (hip microbiology sensitivity (62%), hip histology sensitivity (31%), knee microbiology sensitivity (70%), knee histology sensitivity (21%). Biopsies showed high specificity for knee (microbiology specificity (89%), histology specificity (97%)) and hip (microbiology specificity (73%), histology specificity (91%)). Conclusions. This study demonstrates that US-guided biopsy is a valuable diagnostic aid for PJI with high specificities and PPVs. Furthermore US-biopsy is valuable when there is limited fluid for aspiration


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 112 - 112
11 Apr 2023
Oliver W Nicholson J Bell K Carter T White T Clement N Duckworth A Simpson H
Full Access

The primary aim was to assess the reliability of ultrasound in the assessment of humeral shaft fracture healing. The secondary aim was to estimate the accuracy of ultrasound assessment in predicting humeral shaft nonunion. Twelve patients (mean age 54yrs [20–81], 58% [n=7/12] female) with a non-operatively managed humeral diaphyseal fracture were prospectively recruited and underwent ultrasound scanning at six and 12wks post-injury. Scans were reviewed by seven blinded observers to evaluate the presence of sonographic callus. Intra- and inter-observer reliability were determined using the weighted kappa and intraclass correlation coefficient (ICC). Accuracy of ultrasound assessment in nonunion prediction was estimated by comparing scans for patients that united (n=10/12) with those that developed a nonunion (n=2/12). At both six and 12wks, sonographic callus was present in 11 patients (10 united, one developed a nonunion) and sonographic bridging callus (SBC) was present in seven patients (all united). Ultrasound assessment demonstrated substantial intra- (6wk kappa 0.75, 95% CI 0.47-1.03; 12wk kappa 0.75, 95% CI 0.46-1.04) and inter-observer reliability (6wk ICC 0.60, 95% CI 0.38-0.83; 12wk ICC 0.76, 95% CI 0.58-0.91). Absence of sonographic callus demonstrated a sensitivity of 50%, specificity 100%, positive predictive value (PPV) 100% and negative predictive value (NPV) 91% in nonunion prediction (accuracy 92%). Absence of SBC demonstrated a sensitivity of 100%, specificity 70%, PPV 40% and NPV 100% (accuracy 75%). Of three patients at risk of nonunion based on reduced radiographic callus formation (Radiographic Union Score for HUmeral fractures <8), one had SBC on 6wk ultrasound (and united) and the other two had non-bridging or absent sonographic callus (both developed a nonunion). Ultrasound assessment of humeral shaft fracture healing was reliable and predictive of nonunion, and may be a useful tool in defining the risk of nonunion among patients with reduced radiographic callus formation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 66 - 66
24 Nov 2023
d'Epenoux Louise R Robert M Caillon H Crenn V Dejoie T Lecomte R Tessier E Corvec S Bemer P
Full Access

Background. The diagnosis of periprosthetic joint infection (PJI) remains a challenge in clinical practice and the analysis of synovial fluid (SF) is a useful diagnostic tool. Recently, two synovial biomarkers (leukocyte esterase (LE) strip test, alpha-defensin (AD)) have been introduced into the MSIS (MusculoSkeletal Infection Society) algorithm for the diagnosis of PJI. AD, although promising with high sensitivity and specificity, remains expensive. Calprotectin is another protein released upon activation of articular neutrophils. The determination of calprotectin and joint CRP is feasible in a routine laboratory practice with low cost. Purpose. Our objective was to evaluate different synovial biomarkers (calprotectin, LE, CRP) for the diagnosis of PJI. Methods. In this monocentric study, we collected SF from hip, knee, ankle and shoulder joints of 42 patients who underwent revision or puncture for diagnostic purposes. Exclusion criteria included a joint surgery in the previous 3 months and a diagnosis of a systemic inflammatory disease. PJI was diagnosed in a multidisciplinary consultation meeting (RCP) of the Reference Centers for Osteoarticular Infections of the Great West (CRIOGO). SF was analysed for LE, CRP and calprotectin. The cut-off values used were 50 mg/L for calprotectin, 8.8 mg/L for CRP and 125 WBC/µL for LE. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated for these different synovial markers. Results. Of the 42 patients included, 28 were considered as infected and 14 uninfected. The statistical parameters are presented in Table 1. Conclusion. The present study shows that the synovial calprotectin assay has an excellent sensitivity and a 100% NPV for the diagnosis of PJI, suggesting that a result < 50 mg/L could exclude PJI. This promising study suggests that calprotectin should be included with synovial CRP in a new decision algorithm for the diagnosis of PJI. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_19 | Pages 43 - 43
22 Nov 2024
Bekkers W Zwart V Swietoslawki A Oost IK Nijs A Emmen J Van Geenen R
Full Access

Aim. Periprosthetic joint infection (PJI) is one of the main reasons for revision surgery after primary unicompartmental knee arthroplasty (UKA), total knee arthroplasty (TKA) or total hip arthroplasty (THA). Currently the MSIS and EBJIS criteria sets are considered to be the gold standards in determining PJI. These criteria sets are complex and contain tests that are time-consuming and many are rather costly. Therefore, further research is indicated to find a simpler but equally reliable diagnostic test. In this study we evaluated the additional value of calprotectine measurement in synovial fluid in patients undergoing hip and knee (revision) arthroplasty following routine work-up. Method. In a retrospective cohort study, we analyzed 182 synovial fluid samples from 143 patients with suspected PJI after UKA, TKA, THA or revision arthroplasty. Twenty-six of those cases were classified as PJI according to the MSIS and EBJIS criteria. Subsequently, synovial calprotectin was determined, using a lateral flow assay and two cut-off thresholds of ≥14 mg/L and ≥50 mg/L. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of synovial calprotectin was determined. Results. When applying the MSIS and EBJIS criteria and a calprotectin level ≥14 mg/L, synovial calprotectin revealed an area under the curve of 0.96 (95% CI 0.90-1.00), with 92.3% sensitivity and 100% specificity. The PPV and NPV were 100% and 92.9% respectively. When applying the MSIS and EBJIS criteria and a calprotectin level ≥ 50 mg/L, synovial calprotectin revealed an area under the curve of 0.94 (95% CI 0.87-1.00), with 88.5% sensitivity and 100% specificity. The PPV and NPV were 100% and 89.7% respectively. Conclusions. The value of calprotectin in synovial fluid gives valuable information with a single test result, resulting in high predictive value in the diagnosis of PJI after hip or knee arthroplasty and should seriously be considered as part of PJI diagnostics in an outpatient clinical setting. The high specificity can help rule in patients that are suspected of PJI. Therefor this test can be helpful in a preop diagnostic work-up to avoid unnecessary revisions in patients with well-placed and well-fixed arthroplasties with a suspected PJI. These conclusions are independent of which criteria set was used as a gold standard


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 39 - 39
1 Dec 2022
Grammatopoulos G Pierrepont J Madurawe C Innmann MM Vigdorchik J Shimmin A
Full Access

A stiff spine leads to increased demand on the hip, creating an increased risk of total hip arthroplasty (THA) dislocation. Several authors propose that a change in sacral slope of ≤10° between the standing and relaxed-seated positions (ΔSSstanding→relaxed-seated) identifies a patient with a stiff lumbar spine and have suggested use of dual-mobility bearings for such patients. However, such assessment may not adequately test the lumbar spine to draw such conclusions. The aim of this study was to assess how accurately ΔSSstanding→relaxed-seated can identify patients with a stiff spine. This is a prospective, multi-centre, consecutive cohort series. Two-hundred and twenty-four patients, pre-THA, had standing, relaxed-seated and flexed-seated lateral radiographs. Sacral slope and lumbar lordosis were measured on each functional X-ray. ΔSSstanding→relaxed-seated seated was determined by the change in sacral slope between the standing and relaxed-seated positions. Lumbar flexion (LF) was defined as the difference in lumbar lordotic angle between standing and flexed-seated. LF≤20° was considered a stiff spine. The predictive value of ΔSSstanding→relaxed-seated for characterising a stiff spine was assessed. A weak correlation between ΔSSstanding→relaxed-seated and LF was identified (r2= 0.15). Fifty-four patients (24%) had ΔSSstanding→relaxed-seated ≤10° and 16 patients (7%) had a stiff spine. Of the 54 patients with ΔSSstanding→relaxed-seated ≤10°, 9 had a stiff spine. The positive predictive value of ΔSSstanding→relaxed-seated ≤10° for identifying a stiff spine was 17%. ΔSSstanding→relaxed-seated ≤10° was not correlated with a stiff spine in this cohort. Utilising this simplified approach could lead to a six-fold overprediction of patients with a stiff lumbar spine. This, in turn, could lead to an overprediction of patients with abnormal spinopelvic mobility, unnecessary use of dual mobility bearings and incorrect targets for component alignment. Referring to patients ΔSSstanding→relaxed-seated ≤10° as being stiff can be misleading; we thus recommend use of the flexed-seated position to effectively assess pre-operative spinopelvic mobility


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 71 - 71
24 Nov 2023
Heesterbeek P Pruijn N Boks S van Bokhoven S Dorrestijn O Schreurs W Telgt D
Full Access

Aim. Diagnosis of periprosthetic shoulder infections (PSI) is difficult as they are mostly caused by low-virulent bacteria and patients do not show typical infection signs, such as elevated blood markers, wound leakage, or red and swollen skin. Ultrasound-guided biopsies for culture may therefore be an alternative for mini-open biopsies as less costly and invasive method. The aim of this study was to determine the diagnostic value and reliability of ultrasound-guided biopsies for cultures alone and in combination polymerase chain reaction (PCR), and/or synovial markers for preoperative diagnosis of PSI in patients undergoing revision shoulder surgery. Method. A prospective explorative diagnostic cohort study was performed including patients undergoing revision shoulder replacement surgery. A shoulder puncture was taken preoperatively before incision to collect synovial fluid for interleukin-6 (IL-6), calprotectin, WBC, polymorphonuclear cells determination. Prior to revision surgery, six ultrasound-guided synovial tissue biopsies were collected for culture and two additional for PCR analysis. Six routine care tissue biopsies were taken during revision surgery and served as reference standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV; primary outcome measure), and accuracy were calculated for ultrasound-guided biopsies, and synovial markers, and combinations of these. Results. Fifty-five patients were included. In 24 patients, routine tissue cultures were positive for infection. Cultures from ultrasound-guided biopsies diagnosed an infection in 7 of these patients, yielding a sensitivity, specificity, PPV, NPV, and accuracy of 29.2%, 93.5%, 77.8%, 63.0%, and 65.6%, respectively. Ultrasound-guided biopsies in combination with synovial WBC increased the NPV to 76.7% and accuracy to 73.8%. When synovial WBC and calprotectin were combined with ultrasound-guided biopsies, it resulted in a better diagnostic value: sensitivity 69.2%, specificity 80.0%, PPV 69.2%, NPV 80.0%, and accuracy 75.8%. Ultrasound-guided biopsies in combination with calprotectin and ESR yielded a sensitivity of 50.0%, specificity of 93.8%, PPV of 80.0%, NPV of 78.9%, and accuracy of 79.2%. Synovial fluid was obtained in 42 patients. Sensitivities of WBC, PMN, IL-6, and calprotectin were between 25.0% and 35.7%, specificities between 89.5% and 95.0%, PPVs between 60.0% and 83.3%, NPVs between 65.4% and 69.4%, and accuracies between 64.5% and 70.6%. Conclusions. In this prospective study we showed that ultrasound-guided biopsies for cultures alone and in combination with PCR and/or synovial markers are not reliable enough to use in clinical practice for the preoperative diagnosis of low grade PSI


Aim. The diagnosis of periprosthetic joint infection (PJI) remains a clinical dilemma, since presentations of PJI usually greatly overlap with aseptic failure (AF). The aim of this study is to evaluate the values of plasma fibrinogen, individually or in combination with CRP, ESR and WBC, for distinguishing PJI from AF. Method. We retrospectively enrolled 357 cases who underwent revision hip or knee arthroplasties in the Third Affiliated Hospital of Southern Medical University, Sun Yat-sen Memorial Hospital and the First Affiliated Hospital of Sun Yat-sen University from January 2013 to December 2021, including 197 AF, 116 PJI and 44 reimplantation. The diagnostic capacity of preoperative fibrinogen, CRP, ESR and WBC as well as their combinations for differentiating PJI from AF were assessed by ROC curves. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy were calculated according to the optimal cutoff value based on the Youden index. All biomarkers were further investigated for their potential ability to predict optimal timing of reimplantation as well as their diagnostic capacity in the subgroups of the knee and hip PJI. Furthermore, the correlations among fibrinogen, CRP and ESR in the patients with PJI and AF were analyzed to further evaluate the potential capacity of fibrinogen in the diagnosis of PJI. Results. The levels of fibrinogen, CRP, ESR and WBC were significantly higher in PJI group than in AF group. ROC analyses showed that the AUCs of fibrinogen, CRP, ESR and WBC were 0.879, 0.903, 0.879 and 0.685, respectively. The optimal threshold of fibrinogen is 4.04 g/L (74.1% sensitivity, 85.6% specificity, 76.1% PPV, 85.0% NPV and 81.8% accuracy). Combining fibrinogen with CRP and/or ESR (AUC: 0.903∼0.914) yielded almost equivalent diagnostic efficiency compared with the combination of CRP and ESR (AUC: 0.910). Besides, fibrinogen yielded AUCs of 0.869 (cutoff: 3.44 g/L) and 0.887 (cutoff: 4.12 g/L) in the hip and knee subgroups, with higher specificity and PPV of 93.1% and 96.1% in the knee PJI. Intriguingly, as for the cases with CRP < 10mg/L and ESR ≧ 30 mm/h, the specificity and NPV of fibrinogen for diagnosing PJI were 92.2% and 83.9%. Conclusions. Plasma fibrinogen is considered as a potential first-line screening marker for PJI detection and timing of reimplantation. As for the patients with an increased ESR but normal CRP, a low fibrinogen level (below 4.04 g/L) is more likely to rule out PJI


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 15 - 15
24 Nov 2023
Trenkwalder K Erichsen S Weisemann F Augat P Militz M Hackl S
Full Access

Aim. Treatment algorithms for fracture-related nonunion depend on the presence or absence of bacterial infection. However, the manifestation of septic nonunion varies. Low-grade infections, unlike manifest infections, lack clinical signs of infection and present similarly to aseptic nonunion. The clinical importance of low-grade infection in nonunion is not entirely clear. Therefore, the aim of this study was to evaluate the clinical relevance of low-grade infection in the development and management of femoral or tibial nonunion. Method. A prospective, multicenter clinical study enrolled patients with nonunion and regular healed fractures. Preoperatively, complete blood count without differential, C-reactive protein (CRP), and procalcitonin were obtained, clinical signs of infection were recorded, and a suspected septic or aseptic diagnosis was made based on history and clinical examination. During surgical nonunion revision or routine implant removal, tissue samples were collected for microbiology and histopathology, and osteosynthesis material for sonication. Nonunion patients were followed for 12 months. Definitive diagnosis of “septic” or “aseptic” nonunion was made according to diagnostic criteria for fracture-related infection, considering the results of any further revision surgery during follow-up. Results. 34 patients with regular healed fractures were included. 62 nonunion patients were diagnosed as aseptic, 22 with manifest, and 23 with low-grade infection. The positive predictive value was 88% and the negative predictive value 72% for the suspected diagnosis. The nonunion groups had significantly higher CRP levels than the regular healer group. Differentiation between septic and aseptic nonunion based on blood values was not possible. Low-grade infection demonstrated less frequently histopathologic signs of infection than manifest infection (22% vs. 50%, p=0.048), with 15% of regular healers having histopathologic signs of infection. Cutibacterium acnes was less present in manifest compared to low-grade infection (p=0.042). Healing rates for septic nonunion involving C. acnes were significantly lower for manifest infection (20%) than for low-grade infection (100%, p=0.002). Patients with low-grade infection were treated with systemic antibiotics less frequently than patients with manifest infection (p=0.026), with no significant difference in healing rate (83% vs. 64%), which was slightly lower for low-grade infection than for aseptic nonunion (90%). Conclusions. Low-grade infections play a significant role in nonunion development and are difficult to diagnose preoperatively due to the lack of clinical signs of infection and unremarkable blood counts. However, our results imply that for low-grade infections, antibiotic therapy may not always be mandatory to heal the nonunion. This study was supported by the German Social Accident Insurance (FF-FR0276)


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 6 - 6
1 Oct 2022
Schoenmakers J Boer R Gard L Kampinga GA van Oosten M van Dijl JM Jutte PC Wouthuyzen-Bakker M
Full Access

Aim. Prompt recognition and identification of the causative microorganism in acute septic arthritis of native and prosthetic joints is vital to increase the chances of successful treatment. The aim of this study was to independently assess the diagnostic accuracy of the multiplex BIOFIRE® Joint Infection (JI) Panel (investigational use only) in synovial fluid for rapid diagnosis. Method. Synovial fluid samples were prospectively collected at the University Medical Center Groningen from patients who had a clinical suspicion of a native septic arthritis, early acute (post-operative, within 3 months after arthroplasty) periprosthetic joint infection (PJI) or late acute (hematogenous) PJI. JI Panel results were compared to culture-based methods as reference standard. Results. A total of 45 samples were analyzed. The BIOFIRE JI Panel showed a high specificity (100%, 95% CI 73 – 100) and positive predictive value (100%, 95% CI 79 – 100) in all patient categories. Sensitivity and negative predictive value were 83% (95% CI 36 – 99) and 88% (95% CI 47 – 99) respectively for patients with a clinical suspicion of native septic arthritis (n=12), 77% (95% CI: 46 – 94) and 63% (95% CI: 26 – 90) for patients with a clinical suspicion of a late acute PJI (n=14), and 27% (95% CI 7 – 61) and 27% (95% CI: 7 – 61) for patients with a clinical suspicion of an early acute PJI (n=19). Conclusions. The results of this pilot study indicate a clear clinical benefit of the BIOFIRE JI Panel in patients with a suspected native septic arthritis and late acute (hematogenous) PJI, but a low clinical benefit in patients with an early acute (post-operative) PJI due to the absence of low-grade microorganisms in the panel


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 59 - 59
1 Jul 2022
Chinna S Gaden M Quah C Pickering S
Full Access

Abstract. Introduction. Failing total knee replacement management has included isotope bone scan to identify infection or loosening. BASK guidance suggests bone scans have a poor positive predictive value and are not advised. We assessed isotope bone scanning as a negative predictor to exclude loosening or infection in failing total knee replacement. Methodology. Retrospective review of consecutive bone scans performed to investigate painful total knee replacements for a one-year period (June 2017 to June 2018). 166 bone scans performed. 33 excluded (no notes or scan for other reasons). Demographic information, age of prosthesis, clinic review date, serological markers, results of aspiration and subsequent intraoperative findings also recorded. Results. 133 patients, mean age 72.7, average age of prosthesis 6.8 years. 45% scans performed showed evidence of infection or loosening. Of those positive scans, 70% had aspiration and consideration for revision surgery. 73 patients had negative scans. 2 patients had subsequent aspiration and in 1 patient, S. Epidermidis isolated (1 patient had patellar revision and further samples clear of and other patient declined further surgery). Conclusion. Isotope bone scan had a 97.2% negative predictive value making it a very useful tool to evaluate the failing knee replacement and exclude significant loosening or infection