Advertisement for orthosearch.org.uk
Results 1 - 3 of 3
Results per page:
Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_II | Pages 378 - 378
1 Jul 2008
Khan M Kuiper J Richardson J
Full Access

In-vitro studies have shown that wear rates of the metal on metal (MOM) bearing hip prostheses decline once the bearing runs-in and the bearing subsequently enters a steady state wear phase. Baseline cobalt levels are thus expected to decline with time in patients. Several clinical studies have not found such a decline. Baseline cobalt levels are hence limited in their capacity to provide information on the wear performance of the bearing couple. We have demonstrated in a previous study that exercise causes a rise in plasma metal ion levels in patients with MOM bearing hip replacement. Would the exercise related cobalt rise be more sensitive to detect change in wear behaviour of the bearing couple? We tested the alternate hypothesis that exercise related rise in the plasma cobalt levels will correlate inversely with the duration of MOM implantation. Sixteen patients with three different well functioning MOM bearing hip replacement [two types of resurfacing (BHR, Cormet) and Metasul] were included into the study. Patients were divided in to two groups based on time since implantation, an early group of mean 18 months and a late group of mean 57 months. Plasma levels of cobalt were measured before (baseline) and after 1 hour of maximal exercise (peak). The difference between baseline and peak for each patient provided the exercise related cobalt rise. A significant increase in plasma cobalt levels of 13% was noticed after the exercise (p < 0.005). Baseline Cobalt levels in the late group (53nmol/l) were higher than early group (44nmol/l) but the difference was not significant (p=0.45). However, the mean exercise related Cobalt rise levels was lower in late group (3.5nmol/l) than the early group (6.5nmol/l). This lower rise in cobalt level in the late group precisely reflects on the steady state wear as seen in in-vitro tests. Baseline cobalt levels are limited in determining the in-vivo performance of the bearing couple. Exercise related rise in cobalt levels can differentiate the running in and steady state wear phases of metal on metal bearings and is thus a more accurate tool of assessing in-vivo wear performance of the bearing couple


Bone & Joint Open
Vol. 2, Issue 10 | Pages 785 - 795
1 Oct 2021
Matar HE Porter PJ Porter ML

Aims

Metal allergy in knee arthroplasty patients is a controversial topic. We aimed to conduct a scoping review to clarify the management of metal allergy in primary and revision total knee arthroplasty (TKA).

Methods

Studies were identified by searching electronic databases: Cochrane Central Register of Controlled Trials, Ovid MEDLINE, and Embase, from their inception to November 2020, for studies evaluating TKA patients with metal hypersensitivity/allergy. All studies reporting on diagnosing or managing metal hypersensitivity in TKA were included. Data were extracted and summarized based on study design, study population, interventions and outcomes. A practical guide is then formulated based on the available evidence.


Bone & Joint 360
Vol. 7, Issue 2 | Pages 12 - 15
1 Apr 2018