Advertisement for orthosearch.org.uk
Results 1 - 20 of 768
Results per page:
Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 376 - 377
1 Sep 2005
Ilsar I Har-Even A Brocke L Safran O Leichter Z Foldes A Mattan Y Liebergall M
Full Access

Introduction: The most widely accepted method for measuring bone mineral density (BMD) is Dual-energy X-ray Absorptionmetry (DXA). However, the need for relatively expensive equipment and trained personnel lower the accessibility of DXA as a routine screening tool. Plain pelvic X-ray radiography is a simple and inexpensive examination. In principal, the gray level of the bone in the X-ray radiograph is related to BMD. However, several factors render plain X-ray radiographs of the hip unsuitable for BMD measurements, mainly the variability in X-ray exposure levels and the soft tissue surrounding the bone. In this study, we aimed to develop new modifications of plain X-ray radiography of the proximal femur. Patients and methods: The study population consisted of 18 women with an average age of 77 years (range 57–96 years) who were hospitalized due to a low-energy fracture of the neck of the femur. Each patient’s contralateral hip was radiographed with an aluminium step-wedge positioned near the hip as a standard reference, using a computerized radiography system. A DXA examination of the same hip followed the plain radiograph. On each radiograph, regions of interest (ROI) were determined in concordance with the ROI of the DXA examination. The mean gray level was measured for each ROI. The neck-shaft angle and the femoral head diameter were also measured. Results: Comparing the gray levels of the plain radiograph with the BMD levels obtained by the DXA revealed a coefficient ratio of R=0.499. Correction of the gray levels using the step wedge as a standard reference revealed a ratio of R=0.576. If further correction was made with measurement of the soft tissue gray levels, a ratio of R=0.708 was obtained. Using the anatomical measurements (neck-shaft angle and femoral head diameter), a ratio of R=0.948 was obtained. Conclusion: This study shows that a plain digital radiograph of the pelvis can provide valuable information concerning the bone mineral content of the proximal femur, which is comparable to the results of the DXA examination. Ultimately, the research can lead to the development of a fast, available and relatively inexpensive technique to diagnose osteoporosis


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 522 - 522
1 Oct 2010
Konan S Haddad F Rayan F
Full Access

Radiographic evaluation of the anterolateral femoral head is an essential tool for the assessment of cam type of femoroacetabular impingement. Computerised tomography (CT), magnetic resonance imaging and frog lateral plain radiograph views have all been suggested as imaging options for this type of lesion. Alpha angle is accepted as a reliable indicator of cam type of impingement and this may also be used as an assessment tool for successful operative correction of the cam lesion. The aim of our study was to analyse the reliability of frog lateral view plain radiographs to analyse the alpha angle in cam femoroacetabular impingement. Thirty two patients who presented with femoroac-etabular impingement were studied. Interobserver reliability for assessment of alpha angles on frog lateral radiographic view was analysed using intraclass correlation coefficient. The alpha angles measured on frog lateral views using digital templating tools were compared to those measured on CT scans. A high interobserver reliability was noted for the assessment of alpha angles on frog lateral views with a correlation coefficient of 0.83. The average alpha angles measured on frog lateral views was 58.71 degrees (range 32 to 83.3). The average alpha angle measured on CT was 65.11 degrees (range 30 to 102). However, a poor correlation (Spearman r of 0.2) was noted between the measurements using the two systems. Frog lateral plain radiographs are not reliable predictors of alpha angle. Various factors may be responsible for this such as the projection of the radiographs, patient positioning and quality of images. CT imaging may be necessary for accurate prediction of alpha angle


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 61 - 61
1 Mar 2012
Donaldson OW Heal J Mulford J Wakeley CJ Eldridge JDJ
Full Access

The purpose of our study was to assess the reproducibility and reliability of traditional radiographic methods of diagnosing trochlear dysplasia compared with the gold standard of MRI. Plain radiographs and MRI scans of 36 knees in 28 patients with proven trochlear dysplasia were compared with 18 controls in a single surgeon's practice. The sulcus angle on MRI and axial radiographs was measured. The lateral radiograph was assessed for adequacy, the crossing sign and the trochlear bump sign. The mean axial (radiograph) and MRI sulcus angles in the dysplastic group were 145° and 158° respectively (p=0.0001) compared to 135° and 138° in the control group (p=0.09). The crossing sign was present in 34 out of 36 lateral radiographs in the dysplastic group and 8 out of 18 in the control group equating to a sensitivity of 94% and specificity of 56%. The quality of the lateral radiograph did not significantly alter the sensitivity or specificity of the crossing sign (p=0.01). The bump sign was present in 22 out of 36 lateral radiographs in the dysplastic group and 1 out of 18 in the control group equating to a sensitivity of 61% and specificity of 94%. Our study shows that an increased radiographic sulcus angle is reliable in diagnosing trochlear dysplasia but underestimates it. The bump sign is a reliable predictor of trochlear dysplasia. The crossing sign is sensitive but not specific in diagnosing dysplasia


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_13 | Pages 5 - 5
17 Jun 2024
Aamir J Caldwell R Karthikappallil D Tanaka H Elbannan M Mason L
Full Access

Background. Lisfranc fracture dislocations are uncommon injuries, which frequently require surgical intervention. Currently, there is varying evidence on the diagnostic utility of plain radiographs (XR) and CT in identifying Lisfranc injuries and concomitant fractures. Our aim was to identify the utility of XR as compared to CT, with the nul hypothesis that there was no difference in fracture identification. Methods. A retrospective assessment of patients who had sustained a Lisfranc injury between 2013 and 2022 across two trauma centres within the United Kingdom who underwent surgery. Pre-operative XR and CT images were reviewed independently by 2 reviewers to identify the presence of associated fractures. Results. A total of 175 patients were included. Our assessment identified that XR images significantly under-diagnosed all metatarsal and midfoot fractures. The largest discrepancies between XR and CT in their rates of detection were in fractures of the cuboid (5.7% vs 28%, p<0.001), medial cuneiform (20% vs 51%, p=0.008), lateral cuneiform (4% vs 36%, p=0.113), second metatarsal (57% vs 82%, p<0.001), third metatarsal (37% vs 61%, p<0.001) and fourth metatarsal (26% vs 43%, p<0.001). As compared to CT, the sensitivity of XR was low. The lowest sensitivity for identification however was lateral foot injuries, specifically fractures of the lateral cuneiform (sensitivity 7.94%, specificity 97.3%), cuboid (sensitivity 18.37%, specificity 99.21%), fourth (sensitivity 46.7%, specificity 89.80%) and fifth metatarsal (sensitivity 45.00%, specificity 96.10%). Conclusion. From our analysis, we can determine that XR significantly under-diagnoses associated injuries in patient sustaining an unstable Lisfranc injury, with lateral foot injuries being the worst identified. We advised the use of CT imaging in all cases for appropriate surgical planning


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_III | Pages 450 - 450
1 Oct 2006
Giles L Muller R Winter G
Full Access

Introduction Controversy exists regarding the value of lumbar plain x-ray imaging for patients with low back pain with or without radicular pain (. 1. ,. 2. ,. 3. ). Methods Plain film x-ray and CT imaging from thirty (30; 19M:11F) consecutive patients (aged 20–68 years; mean 42 years) presenting to a public hospital’s spinal pain clinic with low back pain +/− radicular pain, without a history suggesting ‘red flag’ pathology, was examined and measured to determine the incidence of retrolisthesis of L5 on S1 and any associated disc bulge/protrusion. Results Sixteen of the thirty patients (53%) had retrolisthesis of L5 on S1 ranging from 2–9 mm; these patients had either intervertebral disc bulging or protrusion on CT examination ranging from 3–7 mm into the spinal canal. Fourteen patients (47%) without retrolisthesis (control group) did not show any retrolisthesis and the CT did not show any bulge/protrusion. On categorizing x-ray and CT pathology as being present or not, the well positioned ie. true lateral plain x-ray film revealed a sensitivity and specificity of 100% ([95% Conf. Int. = [89%–100%]) for bulge/protrusion in this preliminary study. On taking into account the numerical values of x-ray and CT, a significant correlation (p< 0.001) was found. Discussion In this preliminary study, carefully positioned lateral lumbosacral x-ray films showing L5 on S1 retrolisthesis are highly suggestive of intervertebral disc bulge/protrusion, providing valuable guidance for consideration of lumbosacral CT of MRI examination that is likely to be contributory regarding such pathology


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 343 - 343
1 May 2006
Ilsar I Hareven A Leichter I Safran O Foldes A Mattan Y Liebergall M
Full Access

Introduction: Several factors render plain X-ray radiographs of the hip unsuitable for bone mineral density measurements, mainly variability in X-ray exposure levels and soft tissue surrounding the bone. We present modification of proximal femur digital radiographs to compensate for these interfering factors. Methods: The study population consisted of 99 women, in three groups: 1 – elderly, sustaining a fracture of the neck of the femur. 2 – elderly, without a fracture. 3 – young. Each patient’s hip was radiographed with a brass step-wedge for standard reference. Dual-Energy X-ray Absorptiometry (DEXA) of the same hip was performed. On each radiograph, Regions Of Interest (ROIs) of the proximal femur were determined in concordance with ROI of the DEXA, together with three soft tissue regions surrounding the bone. Mean gray level was measured for each ROI. Results: The difference in gray level of the ROI within the proximal femur was not statistically significant between the groups. Correction of bone gray level to exposure level by dividing the gray level of the ROI to that of the step wedge, resulted in statistically significant difference between group 1 and either group 2 or group 3. Similar results were obtained by correction of bone gray level to soft tissue gray level. Using this method, multiple R. 2. of 0.62 was found predicting the DEXA value from the gray level of each ROI. Conclusions: After correction to the exposure level and to the soft tissue surrounding the bone, a plain digital radiograph of the pelvis can provide valuable information concerning the bone mineral content of the proximal femur. These preliminary results warrant further research aimed at exploring the potential value of this fast, accessible and relatively inexpensive technique to diagnose osteoporosis and the prediction of future fractures


Introduction: With increasing availability of CT scans their use in the investigation of the subtalar joint increases, whilst we continue to use plain x-ray. Using a standardised reporting protocol, we graded x-rays and CT scans to compare the diagnosis made using each modality. Materials and Methods: An atlas and reporting system of the subtalar joint was designed using a modification of Kellgren and Lawrence’s system. 50 consecutive CT scans of the subtalar joint were identified and saved along with paired plain x-rays of the foot and ankle. All investigations were anonymised. Scans were excluded if there were no plain films or there was evidence of previous trauma. Orthopaedic surgeons were asked to report on the 50 CT scans and 50 plain radiographs using the reporting protocol, commenting on two components for each investigation; the anterior and middle facets and the posterior facet of the subtalar joint. Results: In 33% of cases the facets of the subtalar joint could not be appreciated from the plain x-rays. The difference between the modalities in reported grade of degeneration of the anterior and middle facets of the subtalar joint was statistically significant (p= 0.014) but not for the posterior facet (0.726). When looking at the Spearman correlation coefficient, the anterior and middle facets had no correlation (r = − 0.067) although the posterior facet did (r = 0.029). Discussion: When looking at the posterior facet of the subtalar joint plain x-rays and CT scans give comparable results. When looking at the anterior and middle facets the information gained from the plain x-rays bears no resemblance to that gained from the CT scans. Conclusion: The plain x-ray is an inaccurate, unreliable method of investigating degenerate pathology of the subtalar joint and should be superseded, and perhaps replaced, by the CT scan


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_I | Pages 77 - 77
1 Mar 2010
Takenaka N Watanabe Y Nishizawa M Nishizawa Y Matsushita T
Full Access

Objective: The purpose of the present study was to assess whether clinicians are actually able to evaluate the mechanical status of lengthening callus from plain radiographs. Materials and Methods: 36 rats were employed in this study. Their left femurs were lengthened by 6 mm as a bone lengthening model. Rats were euthanized at 4 8 12 and 16 weeks after lengthening. Both femora were X-rayed and then bone density parameters (bone mineral content, bone mineral density and bone area) of lengthening callus were measured using pQCT. Three-point bending test was performed to determine the mechanical strength of the both bones. We defined the ratio of the strength of lengthening side to control side as estimated strength recovery rate (%). Then 20 orthopaedic surgeons evaluated only the X-ray photographs and tried to estimate the relative mechanical strength (%) of the affected side compared to the control side. Results: Between the recovery percentage of mechanical strength and bone mineral content, a positive simple correlation (R2=0.11, p< 0.05) was seen. No significant correlation was seen between the recovery percentage of mechanical strength estimated by orthopaedists and the mechanical strength measured by three-point bending test (qualified doctors: R2=0.0793 p=0.291 unqualified doctors: R2=0.0523 p=0.394). Discussion and conclusion: It became obvious that to estimate the strength of lengthening callus from plain radiographs alone is quite difficult as compared with the studies of the simple fracture model that have been reported until now


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 149 - 149
1 Apr 2012
Benson R Berryman F Nnadi C Reynolds J Lavy C Bowden G Macdonald J Fairbank J
Full Access

Plain radiography has traditionally been used to investigate and monitor patients with adolescent idiopathic scoliosis. The X-ray allows a calculation of the Cobb angle which measures the degree of lateral curvature in the coronal plane. ISIS2 is a surface topography system which has evolved from ISIS, but with much higher precision and speed. It measures the three dimensional shape of the back using structured light and digital photography. This system has the benefit of not requiring any radiation. Lateral asymmetry is the ISIS clinical parameter estimating the curve of the spine in the coronal plane. The aim of this study was to compare this parameter to the Cobb angle measured on plain X-ray. Twelve patients with idiopathic adolescent scoliosis underwent both a standing AP spine X-ray and an ISIS2 scan on multiple occasions. Both scan and X-ray were done within one month of each other. No patient underwent surgery during the study period. The Cobb angle and the degree of lateral asymmetry were calculated. Twelve patients mean age 12.5 years (range 10-16) were investigated using both ISIS2 and X-ray. They had a mean 2.3 (1-5) combined investigations allowing for 30 comparisons. The correlation between the two measurements was r =0.63 (p=0.0002). The Cobb angle measured on ISIS2 was less than that measured by radiograph in 27 out of 30 comparisons. The mean difference between the measurements was mean 6.4° with a standard deviation of 8.2° and 95% confidence interval of 3.3° to 9.4°. In adolescent idiopathic scoliosis, curve severity and rib hump severity are related but measure different aspects of spinal deformity. As expected, these relate closely but not precisely. ISIS2 offers the promise of monitoring scoliosis precisely, without adverse effects from radiation. The small numbers in this series focus on the group of patients with mild to moderate curves at risk of progression. In this group, ISIS2 was able to identify curve stability or progression, without exposing the subjects to radiation


Bone & Joint Research
Vol. 10, Issue 3 | Pages 173 - 187
1 Mar 2021
Khury F Fuchs M Awan Malik H Leiprecht J Reichel H Faschingbauer M

Aims

To explore the clinical relevance of joint space width (JSW) narrowing on standardized-flexion (SF) radiographs in the assessment of cartilage degeneration in specific subregions seen on MRI sequences in knee osteoarthritis (OA) with neutral, valgus, and varus alignments, and potential planning of partial knee arthroplasty.

Methods

We retrospectively reviewed 639 subjects, aged 45 to 79 years, in the Osteoarthritis Initiative (OAI) study, who had symptomatic knees with Kellgren and Lawrence grade 2 to 4. Knees were categorized as neutral, valgus, and varus knees by measuring hip-knee-angles on hip-knee-ankle radiographs. Femorotibial JSW was measured on posteroanterior SF radiographs using a special software. The femorotibial compartment was divided into 16 subregions, and MR-tomographic measurements of cartilage volume, thickness, and subchondral bone area were documented. Linear regression with adjustment for age, sex, body mass index, and Kellgren and Lawrence grade was used.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_X | Pages 71 - 71
1 Apr 2012
Vollans S Michael A Rao A
Full Access

To evaluate and describe the plain radiographic changes observed with time in fusions using SiS-CaP. We describe, for the first time, 4 stages of bone substitute fusion mass (BSFM) radiographic appearance in relation to time post-op. Retrospective, radiological evaluation. Over 200 plain radiographs were evaluated. 70 consecutive fusions for degenerative spinal stenosis were included, in all cases performed by the same surgeon using the same operative technique. Follow-up was from 3 months to 2 years post-op. Radiographs were evaluated for the presence or absence of SiS-CaP granules, bone formation and for evidence of pseudarthrosis. Trends were seen within the BSFM with respect to time. At 6-12 weeks post-op a ‘homogenous granular stage’ indicates the presence of the unchanged SiS-CaP. At 12 weeks, small pockets appear within the BSFM in the ‘vacuolation stage’, indicating bioresorption of the graft. Vacuoles become increasingly radio-opaque indicating bone proliferation during the ‘homogenous lamellar stage’. At variable time between 6 months and 2 years, the BSFM becomes encapsulated in the ‘cortication stage’ visible as a sclerotic rim around the BSFM. We have seen a clear trend in the behaviour of the fusion mass in this case series. The radiological stages we have described above can be closely correlated with previously reported in-vitro and in-vivo studies looking at the micro-function of SiS-CaP. We hope that this description will help to judge the progress of graft incorporation and fusion. Further study of inter and intra-observer correlation will be required


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 27 - 27
1 Jan 2016
Stevens A Wilson C Mercer G Krishnan J
Full Access

Introduction

There are conflicting views when assessing the best imaging modality by which to assess long leg alignment pre and post operatively for patients’ receiving primary total hip replacements. It has been a long standing standard that long-leg radiographs are used for measuring and interpreting alignment of the lower limb, but recently it has been suggested that CT imaging may be a better option for this assessment.

Methods

Patients awaiting total knee replacement surgeries were invited to participate in this clinical trial. 120 participants’ consented and completed both pre and post-operative long-leg radiographs, and lower limb CT scans. Long leg radiographs were analysed and measured by senior orthopaedic surgeons pre and post-operatively, while CT scans were analysed using the perth protocol method by trained radiologists. Mechanical alignment of the lower limb was calculated using both imaging modalities, the CT “scout” scan was used for the measurement of the mechanical alignment.

Pre-operatively the patients had their imaging performed between 1 year and 1 week pre-operatively, and following surgery their imaging was standardised to 6 months post-operatively. For long leg radiographs, patients were asked to stand with their feet shoulder width apart and toes forward facing (on occasion deformities would not allow for this stance, and they were asked to adopt this stance to the best of their ability).


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 1 - 1
1 Nov 2022
Patel R
Full Access

Abstract. Aims. The aim of this study was to evaluate the indications for patients presenting with knee pain undergoing magnetic resonance imaging of the knee prior to referral to the orthopaedic department and to ascertain whether plain radiograph imagining would be more beneficial prior to an MRI scan. Method. A retrospective review of all referrals received by the hospital over a 6-month period was performed. Patients with knee pain that underwent an MRI scan were classified into two age groups, under 50 years and over 50 years old. Patients having undergone Magnetic resonance imaging (MRI) prior to referral were identified, and findings of the scan were recorded. These patients were reviewed further to see if a plain radiograph had been completed prior to or after the MRI. Results. A total of 414 patients were referred. In the over 50's 228 MRI scans were performed. Of these 103/228 patients the predominate finding was meniscal tears and 72/228 had a finding of osteoarthritis. A plain radiograph of the knee was completed 99/228 cases, 28/99 before the MRI. In the under 50's 186 scans were performed and of these 85/186 the predominate finding was meniscal tears. A plain radiograph of the knee was completed in only eighty-three (83/186) cases, (69/83) before the MRI. Conclusion. In over 50s, 57% of patients (129 of 228) did not have a knee X-ray before having an MRI. For a single hospitals referral over 6 months these unnecessary MRI of knee cost the National Health Services £7,500


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_11 | Pages 15 - 15
4 Jun 2024
Jennison T Naveed U Chadwick C Blundell C
Full Access

Introduction. There are nearly 500,000 people with undiagnosed diabetes mellitus in the UK. The incidental finding vascular calcification on plain radiographs in patients with undiagnosed diabetes has the potential to alter patient management in those presenting with pathology. We hypothesised that the presence of vascular calcification on plain radiographs of the foot may predict the diagnosis of diabetes. The primary aim of this case control study was to determine the positive predictive value of vascular calcification to diagnose diabetes. Secondary aims were to determine the odds of having diabetes dependent on other known risk factors for calcification. Methods. A retrospective case control study of 130 diabetic patients were compared to 130 non-diabetic patients that were matched for age and gender. The presence of vascular calcification in anterior, posterior or plantar vessels, and length of calcification were measured on plain radiographs. McNemar's Chi-squared test and positive predictive values were calculated. Conditional logistic regression models were used to estimate the association between calcification and diabetes. Results. 28 patients had type I diabetes and 102 had type II diabetes. The mean age was 58.0 in both groups and 31.5% were females. 89.2% of those with diabetes had calcification present, and 23.1% in those without (p < 0.0001). Calcification in two vessels predicts diabetes with a positive predictive value of 91.2% (95% CI 82.1%–100%). The odds ratio for having diabetes is 78 (95% CI: 7.8 – 784) times higher in a person who has calcification in the blood vessels of their foot than in a person without calcification after adjusting for confounders. Conclusion. This study has demonstrated that vascular calcification in 2 vessels is over 90% predictive of a diagnosis of diabetes. This screening test could be used in future clinics when interpreting radiographs, aiding in the diagnosis of diabetes and altering patient management


Bone & Joint Open
Vol. 2, Issue 8 | Pages 599 - 610
1 Aug 2021
Hothi H Bergiers S Henckel J Iliadis AD Goodier WD Wright J Skinner J Calder P Hart AJ

Aims. The aim of this study was to present the first retrieval analysis findings of PRECICE STRYDE intermedullary nails removed from patients, providing useful information in the post-market surveillance of these recently introduced devices. Methods. We collected ten nails removed from six patients, together with patient clinical data and plain radiograph imaging. We performed macro- and microscopic analysis of all surfaces and graded the presence of corrosion using validated semiquantitative scoring methods. We determined the elemental composition of surface debris using energy dispersive x-ray spectroscopy (EDS) and used metrology analysis to characterize the surface adjacent to the extendable junctions. Results. All nails were removed at the end of treatment, having achieved their intended lengthening (20 mm to 65 mm) and after regenerate consolidation. All nails had evidence of corrosion localized to the screw holes and the extendable junctions; corrosion was graded as moderate at the junction of one nail and severe at the junctions of five nails. EDS analysis showed surface deposits to be chromium rich. Plain radiographs showed cortical thickening and osteolysis around the junction of six nails, corresponding to the same nails with moderate – severe junction corrosion. Conclusion. We found, in fully united bones, evidence of cortical thickening and osteolysis that appeared to be associated with corrosion at the extendable junction; when corrosion was present, cortical thickening was adjacent to this junction. Further work, with greater numbers of retrievals, is required to fully understand this association between corrosion and bony changes, and the influencing surgeon, implant, and patient factors involved. Cite this article: Bone Jt Open 2021;2(8):599–610


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 82 - 82
19 Aug 2024
Courington R Ferreira R Shaath MK Green C Langford J Haidukewych G
Full Access

When treating periprosthetic femur fractures (PPFFs) around total hip arthroplasty (THA)], determining implant fixation status preoperatively is important, since this guides treatment regarding ORIF versus revision. The purpose of this study was to determine the accuracy of preoperative implant fixation status determination utilizing plain films and CT scans. Twenty-four patients who underwent surgery for Vancouver B type PPFF were included in the study. Two joint surgeons and two traumatologists reviewed plain films alone and made a judgment on fixation status. They then reviewed CT scans and fixation status was reassessed. Concordance and discordance were recorded. Interobserver reliability was assessed using Kendall's W and intraobserver reliability was assessed using Cohen's Kappa. Ultimately, the “correct” response was determined by intraoperative findings, as we routinely test the component intraoperatively. Fifteen implants were found to be well-fixed (63%) and 9 were loose. Plain radiographs alone predicted correct fixation status in 53% of cases. When adding the CT data, the correct prediction only improved to 55%. Interestingly, concordance between plain radiographs and CT was noted in 82%. In concordant cases, the fixation status was found to be correct in 55% of cases. Of the 18% of cases with discordance, plain films were correct in 43% of cases, and the CT was correct in 57%. Interobserver reliability demonstrated poor agreement on plain films and moderate agreement on CT. Intraobserver reliability demonstrated moderate agreement on both plain films and CT. The ability to determine fixation status for proximal PPFFs around uncemented femoral components remains challenging. The addition of routine CT scanning did not significantly improve accuracy. We recommend careful intraoperative testing of femoral component fixation with surgical dislocation if necessary, and the surgeon should be prepared to revise or fix the fracture based on those findings


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 2 - 2
7 Jun 2023
Sharrock M Board T
Full Access

It is unclear whether patients with early radiographic osteoarthritis (OA) but severe hip symptoms benefit from total hip replacement (THR). We aimed to assess which factors were associated with successful THR in this patient group. From a consecutive series of 1,935 patients undergoing THR we identified 70 (3.6%) patients with early OA (Kellgren and Lawrence (KL) grades 0-2). These were compared with 200 patients with advanced OA (KL grades 3–4). Outcomes were Oxford Hip Scores (OHS), EQ5D and EQ-VAS scores; compared pre-operatively with one year post-operatively. We investigated which clinical and radiographic (plain x-ray, CT, MRI) features predicted successful THR in the early OA group. Success was defined as reaching a postoperative OHS≥42. The early OA group were significantly younger (61 vs 66 years; P=0.0035). There were no significant differences in body mass index, ASA grade or gender. After adjusting for confounders, the advanced OA group had a significantly greater percentage of possible change (PoPC) in OHS (75.8% versus 50.4%; P<0.0001) and improvement in EQ5D (0.151 versus 0.002; P<0.0001). There were no significant differences in complication, revision or readmission rates. In the early OA group, we identified 16/70 (22.9%) patients who had a ‘successful’ THR. Of those with early OA, 38 patients had pre-operative CT or MRI scans. Patients who had a ‘successful’ THR were significantly more likely to have subchondral cysts on CT/MRI (91.7% versus 57.7%; P=0.0362). The presence of cysts on CT/MRI was associated with a significantly greater PoPC in OHS (61.6% versus 38.2%; P=0.0353). The combination of cysts and joint space width (JSW) <1mm was associated with a PoPC of 68%. Plain radiographs were found to significantly underestimate the narrowest JSW compared to CT/MRI (2.4mm versus 1.0mm; P<0.0001). We advise caution in performing THRs in patients with early OA (KL grades 0-2) on plain radiographs. We advocate pre-operative cross-sectional imaging (CT or MRI) in these patients. In the absence of cysts on cross-sectional imaging, a THR seems unlikely to provide a satisfactory outcome


Bone & Joint Open
Vol. 3, Issue 11 | Pages 913 - 920
18 Nov 2022
Dean BJF Berridge A Berkowitz Y Little C Sheehan W Riley N Costa M Sellon E

Aims. The evidence demonstrating the superiority of early MRI has led to increased use of MRI in clinical pathways for acute wrist trauma. The aim of this study was to describe the radiological characteristics and the inter-observer reliability of a new MRI based classification system for scaphoid injuries in a consecutive series of patients. Methods. We identified 80 consecutive patients with acute scaphoid injuries at one centre who had presented within four weeks of injury. The radiographs and MRI scans were assessed by four observers, two radiologists, and two hand surgeons, using both pre-existing classifications and a new MRI based classification tool, the Oxford Scaphoid MRI Assessment Rating Tool (OxSMART). The OxSMART was used to categorize scaphoid injuries into three grades: contusion (grade 1); unicortical fracture (grade 2); and complete bicortical fracture (grade 3). Results. In total there were 13 grade 1 injuries, 11 grade 2 injuries, and 56 grade 3 injuries in the 80 consecutive patients. The inter-observer reliability of the OxSMART was substantial (Kappa = 0.711). The inter-observer reliability of detecting an obvious fracture was moderate for radiographs (Kappa = 0.436) and MRI (Kappa = 0.543). Only 52% (29 of 56) of the grade 3 injuries were detected on plain radiographs. There were two complications of delayed union, both of which occurred in patients with grade 3 injuries, who were promptly treated with cast immobilization. There were no complications in the patients with grade 1 and 2 injuries and the majority of these patients were treated with early mobilization as pain allowed. Conclusion. This MRI based classification tool, the OxSMART, is reliable and clinically useful in managing patients with acute scaphoid injuries. Cite this article: Bone Jt Open 2022;3(11):913–920


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 13 - 13
1 Nov 2018
Burgan A Jaker S
Full Access

The Ottawa Rules were developed in 1992 by Stiell et al. to “assist clinicians in being more selective in their use of radiography” in suspected ankle fractures. They have a sensitivity of almost 100% and should reduce the number of unnecessary radiographs by 30–40%. We aimed to determine the application of the Ottawa Rules in ankle plain radiograph requests in Accident and Emergency (A&E) and determine the number of unnecessary plain radiographs requests. We carried out a retrospective analysis of 366 ankle plain radiographs, request forms and reports, in A&E over 3 months. We implemented a reminder on the electronic requesting system to prompt clinicians to apply the Ottawa rules and analysed a further 226 scans over the next month. Unnecessary scans were calculated by determining the false negatives. i.e. requests did not fulfil Ottawa Rules and scan showed no fracture. Of the 336 original requests, 45% fulfilled the Ottawa Rules and 43% of all scans were unnecessary. Following our intervention, only 42% of requested scans fulfilled the Ottawa rules and 52% were unnecessary. We concluded that Ottawa rules are knowingly not applied in A&E. Reasons may include low cost and ease of scan, patient and clinician reassurance and perceived low risk of scanning. There are a huge number of unnecessary ankle plain radiographs and soft interventions do not impact on this. We have implemented a simplified version of the text reminder and are re-auditing the data


Bone & Joint Open
Vol. 4, Issue 11 | Pages 839 - 845
6 Nov 2023
Callary SA Sharma DK D’Apollonio TM Campbell DG

Aims. Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of highly cross-linked polyethylene (XLPE) acetabular components. We have previously reported very low wear rates for a sequentially irradiated and annealed X3 XLPE liner (Stryker Orthopaedics, USA) when used in conjunction with a 32 mm femoral heads at ten-year follow-up. Only two studies have reported the long-term wear rate of X3 liners used in conjunction with larger heads using plain radiographs which have poor sensitivity. The aim of this study was to measure the ten-year wear of thin X3 XLPE liners against larger 36 or 40 mm articulations with RSA. Methods. We prospectively reviewed 19 patients who underwent primary cementless THA with the XLPE acetabular liner (X3) and a 36 or 40 mm femoral head with a resultant liner thickness of at least 5.8 mm. RSA radiographs at one week, six months, and one, two, five, and ten years postoperatively and femoral head penetration within the acetabular component were measured with UmRSA software. Of the initial 19 patients, 12 were available at the ten-year time point. Results. The median proximal, 2D, and 3D wear rates calculated between one and ten years were all less than 0.005 mm/year, with no patient recording a proximal wear rate of more than 0.021 mm/year. Importantly, there was no increase in the wear rate between five and ten years. Conclusion. The very low wear rate of X3 XLPE liners with larger articulations remains encouraging for the future clinical performance of this material. Cite this article: Bone Jt Open 2023;4(11):839–845