Advertisement for orthosearch.org.uk
Results 1 - 20 of 30
Results per page:
Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 358 - 358
1 Sep 2005
Sekel R Kandel L Debi R Eberle R Lanzer W McPherron A
Full Access

Introduction and Aims: The incidence and technical complexity of revision total hip arthroplasty (THA) has and will continue to increase dramatically. We report the results of revision THA using a non-cemented, dual threaded, cone shaped, (DTCS) modular femoral component. Method: Between June of 1999 and July of 2003, 41 revision THAs using a DTCS modular femoral component. Fifty-four percent of the patients were male and 46% were female with an average weight of 84kg (std dev: 30kg, range 57–60 kg), an average height of 170cm (sdt dev: 9cm, range: 155–182 cm) and an average body mass index (BMI) of 26 (std dev: 4, range: 18–31). The average patient age was 71 years (std dev: 12 years, range: 39–85 years). Results: The average patient follow-up was 16 months (range 6–49 months). The average Harris hip score (HHS) at the most recent time to follow-up was 76. Broken into the HHS component parts, the average pain score was 40 of a possible 44, average motion was nine of a possible nine, and average function was 28 of a possible 47. Radiographic evaluation revealed wellfixed and positioned components with evidence of bone densing in areas in intimate contact with the DTCS component. Radiographic evidence of minor stress shielding was observed in the greater trochanter (Gruen Zone 1) and the proximal calcar/neck cut region (Gruen Zone 7). Post-operative complications included recurrent infection in four (10%), subsequently resolved with IV antibiotics; dislocation in three (7%), successfully treated by closed reduction and protective bracing; aseptic loosening in one (2%), with femoral component revision to a larger size; intra-operative periprosthetic fracture in one (2%), treated with ORIF (bone, plate and screws); and a non-union of a pre-revision fracture with subsequent component loosening in one (2%). Regardless of the degree of femoral deficiency, there was no incidence of component disassociation or component fracture. Conclusion: Revision THA is a demanding undertaking and involves multivariate technical challenges that may include mechanical and material considerations such as prosthetic loosening, prosthetic and periprosthetic fracture. We show that the use of a DTCS modular femoral component affords the surgeon results equal to those reported for revision THA and allows intra-operative versatility independent of bone quality


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 42 - 42
1 Mar 2013
Cohen R
Full Access

Modularity of femoral components has been widely accepted at the head neck junction, most commonly combining two unlike metals with only sporadic reporting of compatibility issues and corrosion. The development and introduction of a new and improved modular neck junction (Rejuvenate Modular Femoral component, Stryker Orthopedics) provided the option of fine-tuning leg lengths, offset and stability. The surgical technique did indeed provide the desired endpoints, however, the early recognition of problems with the junction causing corrosion and Adverse Local Soft Tissue Reaction (ALTR) and subsequent revision has led to the product being voluntarily withdrawn from the market. My experience as an early user of this stem is described in this manuscript providing a better early recognition and treatment of this potentially very destructive process. Methods. A retrospective review of one hundred and ninety one Rejuvenate Stems that were implanted between January 2010 and January of 2012. However, after March 2011, this stem was only used on those patients who had a rejuvenate stem on the contralateral side. They were all implanted through a mini posterior incision with the first 82 patients receiving a Tritanium cluster hole cup (Stryker Orthopedics) with between two and three screws. The remaining 109 patients had an ADM (Anatomic Dual Mobility, Stryker Orthopedics). All patients were allowed to bear weight as tolerated and were followed up with Xrays at six weeks and one year. Clinical visits were recorded at 2 weeks and 6 months postop. Additional follow up was scheduled every two years following the first annual visit. Results. One hundred and seventy four of the 191 hips were available for review at the one-year follow-up. Fourteen patients have undergone revision of the hip due to increased pain and formation of an avascular pseudo capsule due to corrosion at the neck stem junction. All patients have demonstrated a black flaky residue at the taper junction and all have had a large, tense effusion with a milky colored fluid. A neo caspsule has formed in all patients that appeared avascular and thickened. Seven of the eight tritanium cups in the revision cases were loose and required revision, while none of the ADM cups were loose. One patient has undergone two revisions since the initial cause of failure was not recognized and she subsequently developed pain within three months following placement of a new modular neck at the initial revision. One patient who underwent revision developed a deep infection and is currently on antibiotics but has not cleared the infection as of this writing. Conclusion. There has been catastrophic early failure of a modular femoral component due to corrosion at the neck stem junction during the very early stages of follow up. An intense reaction appears to begin early on, perhaps contributing to failure of bony ingrowth in certain cup designs but not others. Patients who develop early onset of discomfort progress to a poorly functioning hip that presents with pain, swelling and decreased ROM. These patients need to be assessed with serum ion levels, joint aspiration for infection and ion levels if possible. A MRI with MARS technology is useful in identifying joint fluid and neo caspsule expansion. These patients should be advised on the adverse reaction that can develop and revision of the hip should be expeditiously carried out


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 514 - 515
1 Oct 2010
Fraitzl C Buly R Castellani L Moya L Wright T
Full Access

Introduction: The S-ROM. ®. modular hip system (DePuy, Warsaw, IN) has a cementless femoral component made of titanium alloy with a distally fluted and slotted stem. The stem mates with a sleeve that is implanted in the proximal femur. No reports exist in the literature of intraoperative difficulties in disengaging the sleeve-stem interface. Induced by the impossibility of intraop-eratively disconnecting the sleeve-stem interface in one patient leading to unintended revision of a well-fixed sleeve, we asked whether in vivo evidence for fretting or mechanically-assisted crevice corrosion of the mating surfaces could be found in retrieved components and whether its appearance is influenced by factors such as length of implantation. Methods: The sleeve-stem combinations were retrieved from 1998 to 2008 as part of our IRB-approved implant retrieval system. Twenty-two sleeve-stem interfaces of S-ROM. ®. femoral components were located in our retrieval collection. Seven sleeve-stem combinations were still mated when retrieved; 2 were disengaged by hammering the sleeve away from the stem, the remaining 5 had to be cut longitudinally with a diamond saw to disengage the sleeve from the stem. All disengaged sleeves were also cut to expose their inner surfaces. The surfaces of the taper region and the corresponding inner surfaces of the split sleeves were inspected macroscopically and assigned to the following groups: severe corrosion; moderate surface changes; and few or no evidence of surface changes. Microscopic examination was used to grade fretting and corrosion using an established subjective scale (Goldberg et al., 2002). The surface of the taper and the sleeve was divided into 12 regions each and every region was evaluated separately. The mean score of all 24 regions was calculated and opposed to the implantation time of the respective femoral component. Statistical analysis of correlation between the mean score and implantation length was performed using the Pearson product moment correlation. Additionally, the surface of the taper regions of 6 specimens underwent detailed analysis with SEM and EDAX. Results: In 3 of 22 sleeve-stem interfaces severe corrosion accounting for at least 80% of the surface area was detected. Furthermore, ten sleeve-stem interfaces showed moderate surface changes. Nine sleeve-stem interfaces showed few or no surface changes. There was no correlation between presence of corrosion and implantation length (r=0.13; p=0.56). Conclusion: In 3 of 22 retrieved sleeve-stem interfaces severe corrosion was found at the stem-sleeve interface. Though apparently not the rule, failure to disengage the stem from the sleeve undermines an important advantage of this type of modularity in total hip replacement and suggests that alternative procedures should be anticipated when planning for revision surgery of such (or a similar) modular femoral component


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 199 - 199
1 Jun 2012
Ryan M Fait J Khan A Barnes G
Full Access

Purpose

In revision hip surgery, Type IIIB femurs have presented the greatest historical challenge to achieving stable fixation and osseous integration. This study evaluated the intermediate term outcome of a modular, tapered, distal fixation revision femoral component used in a consecutive revision hip series with special attention to its performance in the defective Type IIIB femur.

Methods

Between February 2002 and January 2005, 51 consecutive revision hip arthroplasties were performed using modular, tapered, distal fixation femoral components. The femoral defects at the time of revision surgery were classified using a system previously described by Paprosky. The most recent radiographs were reviewed and clinic notes examined to assess femoral component stability.


Orthopaedic Proceedings
Vol. 87-B, Issue SUPP_III | Pages 365 - 365
1 Sep 2005
Sekel R Eberle R Richardson M Lanzer W Gibson D Kwong L Mallin B Infante A
Full Access

Introduction and Aims: Currently, multiple femoral component types and sizes exist for primary total hip arthroplasty. However, component sizes for small femoral geometry are generally not available. The purpose of this study is to present the short-term use of a femoral component with sizes that extend into small femoral morphometry applications. Method: Between November 2001 and December 2003, 20 primary THA cases and three revision THA cases were performed utilising a non-cemented, dual threaded, cone shaped (DTCS) modular femoral component manufactured in off-the-shelf sizes, which include those sizes for small femora. The components are made of CoCr and include a size ‘Z’ (19mm proximal, 9mm distal) and a size ‘Y’ (17mm proximal, 8mm distal). Both components have hydroxyapatite coating for stimulating increased bone on-growth and a modular neck allowing intra-operative adjustments of leg length, version, offset and neck length. Results: The average patient follow-up was 10 months (range 64 days to 27 months). There were 19 (83%) hips in which the ‘Z’ component was used, and four (17%) hips with the ‘Y’ component. Radiographic evaluation revealed well-fixed and positioned components with evidence of bone densing in areas in intimate contact with the DTCS component. Radiographic evidence of minor stress shielding was observed in the greater trochanter (Gruen Zone 1) and the proximal calcar/neck cut region (Gruen Zone 7). Two revision cases (8%) required the additional use of a 6cm modular extension component (MEC) to bridge a proximal femoral deficiency. Two cases (8%) required adjunctive strut allografting at the time of surgery to protect a thin or deficient femoral cortex. There were no reported postoperative complications related to the femoral component. There was no disassociation of the modular neck from the femoral stem and there was no incidence of femoral component fracture. Conclusion: While expanding component profile offerings into larger sizes is common, developing similar component designs for abnormally small femora is uncommon, beyond the scope of the materials used and only done as a ‘custom’ order. The DTCS modular femoral component used affords a versatile option when presented with cases involving small femoral morphometry. We conclude that the DTCS component in smaller sizes is promising and warranted for continued use


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_10 | Pages 43 - 43
1 May 2016
Slover J Riesgo A Hochfelder J Adler E Specht L Iorio R
Full Access

We retrospectively reviewed 161 revision THAs with diaphyseal fitting, mid- modular femoral components performed by ten surgeons at two academic medical centers. The average follow-up was 6.1 years. At final follow-up, 4 patients required re-revision for failure of the femoral component; 3 (2%) for aseptic loosening and 1 for mechanical failure of stem in setting of periprosthetic fracture. There were a total of 24 (14.9%) revisions for any reason, with the most common reason being septic failure (10 of 24). To our knowledge, this is the largest reported series of mid-term survivorship and complications of revision THA with mid-modular femoral components. Our results show that these stems have a low rate of aseptic loosening, subsidence, and mechanical failure


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_15 | Pages 78 - 78
1 Aug 2017
Lachiewicz P
Full Access

Uncemented metal-on-polyethylene total hip arthroplasties (THAs) have had a modular cobalt-chrome alloy head since their introduction in the early 1980's. Retrieval analysis studies and case reports in the early 1990's first reported corrosion between the femoral stem trunnion (usually titanium alloy) and cobalt-chrome alloy femoral head. However, then this condition seemed to disappear for about two decades? There are now numerous recent case series of this problem after metal-on-polyethylene THA, with a single taper or dual taper modular femoral component. Metal ion elevation, corrosion debris, and effusion are caused by mechanically assisted crevice corrosion (MACC). These patients present with diffuse hip pain, simulating trochanteric bursitis, iliopsoas tendinitis, or even deep infection. Trunnion corrosion, with adverse local tissue reaction, is a diagnosis of exclusion, after infection, loosening, or fracture. The initial lab tests recommended are: ESR, CRP, and serum cobalt and chromium ions. With a metal-on-polyethylene THA, a cobalt level > 1ppb is abnormal. Plain radiographs are usually negative, but may show calcar osteolysis or acetabular erosion or cyst. MARS MRI may be the best imaging study to confirm the diagnosis. Hip aspiration for culture and cell-count may be necessary. The operative treatment is empiric, with debridement, and head exchange with a ceramic head-titanium sleeve (or oxidised zirconium head) placed on the cleaned trunnion. The femoral component may have to be removed if there is “whole trunnion failure”. This usually relieves the symptoms, but the complication rate of this procedure may be high


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_7 | Pages 11 - 11
1 Apr 2017
Murphy S
Full Access

Distal neck modularity places a modular connection at a mechanically critical location, which is also the location that confers perhaps the greatest clinical utility. The benefits of increased clinical options at that location must be weighed against the potential risks of adding an additional junction to the construct. Those risks include prosthetic neck fracture, taper corrosion, metal hypersensitivity, and adverse local tissue reaction. Further, in-vitro testing of ultimate or fatigue strength of femoral component designs has repeatedly failed to predict behavior in-vivo, raising questions about the utility of in-vitro testing that does not incorporate the effect of mechanically assisted crevice corrosion into the test design. The material properties of Ti alloy and CoCr alloy place limits on design considerations in the proximal femur. The smaller taper junctions that are necessary for primary reconstruction are particularly vulnerable to failure whereas larger taper junctions commonly used in revision modular femoral component designs have greater opportunity for success. Modular junctions of CoCr alloy on conventional Ti alloy have been shown to have a greater incidence of clinically significant mechanically assisted crevice corrosion and adverse reaction. Designs that have proven clinical strength and utility universally have larger, more robust junctions, that extend into the metaphysis of the femur. While these designs are primarily designed for revision total hip replacement (THR), they are occasionally indicated for primary THR. Overall, however, while design options at the neck-stem junction have unmatched clinical utility, no design that does not extend into the metaphysis has proven to be universally reliable. While routine use of modular neck components for primary THR does not appear to be clinically indicated based on current evidence, modular designs with proven successful proximal junctions appear to be indicated for revision THR and rare primary THR with extreme version or other anatomical circumstances


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 30 - 30
1 Feb 2015
Perka C
Full Access

The endoprosthetic treatment of secondary osteoarthritis resulting from congenital hip dysplasia is difficult due to the small diameter of the acetabulum and the hypoplastic anterolateral bone stock. On the femoral side the increased femoral anteversion, insufficient femoral offset and proximal femoral deformities (mostly valgus deformities) as well as the small diameter and straight form of the intramedullary canal pose challenges. Careful preoperative planning is mandatory. The Crowe classification is usually used to describe these pathologies. In severe cases (Crowe 3 and especially Crowe 4) a shortening and derotating femoral osteotomy should be taken into account. Small acetabular components, acetabular augments, and modular femoral components must be available at all times. For acetabular fixation press-fit cups are preferred today, but excellent results were also described for threaded cups. The advantage of press-fit cups is the extensively documented and superior track record, but threaded cups allow for an easier reconstruction of the original hip center as well as slight medialization. As a result of medialization a reduction in polyethylene wear together with a low rate of loosening lead to very good long-term results in a younger patient population. Cementless straight stems are documented to be preferable for the small femoral diameter and the straight anatomic shape of the proximal femur. Nevertheless, the higher complication rate, especially the increased rate of nerve palsies, should be preoperatively discussed with the patient. The ideal bearing surface is currently unclear, ceramic-on-ceramic seems to be promising, although the longest data available support the use of metal-on-polyethylene


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 54 - 54
1 Jun 2012
El-Ganzoury I Salem A
Full Access

Two-stage revision arthroplasty is the gold standard for treatment of infection after total hip Arthroplasty and end stage septic arthritis of the hip. In the first stage we used a modified technique to insert an inexpensive modular femoral component coated with antibiotic-impregnated polymethylmethacrylate articulating with a polyethylene liner. The construct was used in 8 patients with infected arthroplasty, and 6 patients with septic arthritis of the hip. Two patients were excluded (no second stage). Of the remaining 12 patients, only one patient had persistent infection after the first stage; 11 patients received a successful re-implantation at the second-stage. The technique provide a construct that can be used safely and successfully in the awaiting period between the two stages of revision arthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 53 - 53
1 Dec 2016
Berend K
Full Access

Background. Modular component options can assist the surgeon in addressing complex femoral reconstructions in total hip arthroplasty (THA) by allowing for customization of version control and proximal to distal sizing. Tapered stem fixation has a proven excellent track record in revision THA. Early reports by Cherubino et al. (Surg Technol Int 2010) 65 revision THA with an average follow up of 109 months (range, 76–131) demonstrate satisfactory integration in 100% of cases. Rodriguez et al.(J Arthroplasty 2009) report 96% survival in 102 revision THA at nearly 4 years average follow up. We review the early clinical results of a modular tapered femoral revision system. Methods. A query of our practice's arthroplasty registry revealed 60 patients (61 hips) who signed an IRB-approved general research consent allowing retrospective review, and underwent THA performed with the modular femoral revision system between December 2009 and April 2012. There were 35 men (58%) and 25 women (42%). Mean age was 65.1 years (range, 35–94) and BMI was 31.3 kg/m2 (range, 14–53). Procedures were complex primary in 1 hip, conversion in 6 (10%), revision in 32 (53%), and two-staged exchange for infection in 22 (33%). Two-thirds of the procedures included complete acetabular revision (n=40), while 31% (19) involved liner change only and 2 were isolated femoral revisions. Results. At an average follow-up of 1.5 years (maximum: 3.7 years) there have been no revisions or failures of the femoral component. Average Harris hip scores (0 to 100 possible) improved from 44.2 preoperatively to 66.0 at most recent evaluation, while the pain component (0 to 44 possible) improved from 15.8 to 31.2. Complications requiring surgical intervention included intraoperative periprosthetic femur fracture in one patient returned to the operating suite same day for open reduction internal fixation, which further required incision and debridement for superficial infection at 1 year postoperative; and two patients with dislocation and fracture of the greater trochanter treated with open reduction, revision of the head and liner, and application of cerclage cables, one of which required removal of a migrated claw 10 months later followed 2 weeks subsequently with incision and debridement for a non-healing wound. Postoperative radiographs were available for review for 59 THA in 58 patients. Analysis of the femoral component revealed satisfactory findings in 50 hips (85%) while 9 had radiographic changes that included bone deficit, osteolysis, or radiolucency in one or more zones. Conclusions. The early results of this modular femoral revision system are promising for the treatment of the deficient femur in complex primary and revision total hip arthroplasty. Patients with radiographic changes are advised to return for regular clinical and radiographic follow-up. Survival of the modular femoral component in this series was 100% at mean follow-up of 1.5 years and up to 3.7 years. While Harris hip clinical and pain scores were somewhat low at most recent evaluation, they were significantly improved over preoperative levels


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_22 | Pages 31 - 31
1 Dec 2016
Kraay M
Full Access

Arthritis of the hip is a relatively common problem in patients with neuromuscular disorders due to muscle imbalance around the hip from weakness, paralysis, contractures and spasticity. Neuromuscular disorders such as cerebral palsy, Parkinson's disease, poliomyelitis, previous cerebrovascular accident (CVA) and Charcot arthropathy have been considered by many to be contraindications to total hip arthroplasty (THA). The presence of certain anatomic abnormalities (excessive femoral anteversion, acetabular dysplasia, leg length discrepancy (LLD) and coax valga) and significant soft tissue contractures, muscle imbalance, and muscular weakness make THA a challenging surgical procedure in this patient population, and can predispose to dislocation and poor functional outcome following surgery. THA can, however, result in substantial pain relief and functional improvement, and can be safely performed, provided certain technical considerations are addressed. The patient's motor strength and functional status (ambulatory vs. “sitter”) should be carefully assessed preoperatively, since both of these factors may affect the choice of surgical approach and component position. Significant soft tissue contractures should be released at the time of surgery. Although these can be frequently performed “open”, percutaneous adductor tenotomy is occasionally necessary for patients with significant adduction contractures. Patients requiring significant soft tissue releases may benefit from 6 weeks of bracing to allow soft tissues to heal in appropriately and minimise risk of dislocation during this period of time. Use of modular femoral components that allow for correction of excessive femoral anteversion, should be considered in patients with coexistent dysplasia and neuromuscular disease (i.e., CP or polio). Large femoral head components should also be considered in patients with increased risk factors for dislocation. Despite their obvious theoretical advantages, the use of large head metal on metal THAs should be used with extreme caution in view of growing concerns about these devices. Although constrained acetabular liners are associated with an increased risk of mechanical failure, their use should be strongly considered in patients with significant motor weakness or major soft tissue deficiencies. Meticulous soft tissue closure of the capsule of the hip is recommended, especially when performing THA through a posterior approach. Patients with neuromuscular disorders associated with spasticity and involuntary movements need to be optimally treated medically prior to and indefinitely after THA. There are limited reports of outcomes following THA in patients with neuromuscular disorders, however, some generalizations based on underlying diagnosis can be made. Patients with cerebral palsy and polio frequently have acetabular dysplasia, excessive femoral anteversion and LLD, and although durability does not seem to be a major concern, dislocation and instability is relatively common and needs to be addressed. Durability and instability do not appear to be major concerns in patients with Parkinson's disease, however, these patients have frequent medical complications perioperatively and have deterioration in function over time due to the progressive nature of their underlying disorder. Patients with previous CVA also appear to have acceptable durability and dislocation risk, but are at high risk of developing heterotopic ossification postoperatively. Patients with Charcot arthropathy or myelodysplasia are at high risk of instability and appear to have limited functional improvement following THA. As a result, the consensus of opinion is that THA is contraindicated in these patients


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 577 - 577
1 Nov 2011
Gross M Amirault D Dunbar MJ
Full Access

Purpose: To report a series of unexpected femoral neck failures in a series total hip replacement surgeries using a modular femoral component. Method: A series of 443 hip replacement patients received modular necks as part of a non cemented hip replacement with ceramic articulations at the acetabulum and femoral head interface. The first implant of the device was on June 8, 2004 and the last on June 12, 2009. Ninety-one of those patients were enrolled in a RSA study of component stability within the proximal femur. Results: The index fracture of a femoral neck occurred on March 8, 2009 when the patient (28 months post hip replacement) reported a fall. Subsequently five patients have had a fracture of the modular neck. There were five fractures within the RSA study group and one within the non study group (all occurred 17 months to 30 months post op). All fractures were long necks (10.5 mm). There was no difference in femoral component micromotion as measured with RSA between the fractured group and the unrevised group. Conclusion: Initial non-destructive testing of one retrieval revealed fatigue failure of the femoral neck. An independent study of all relevant data was implemented which included destructive testing of the implants and clinical data with respect to patient activity. We report the outcome of all those investigations


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 477 - 477
1 Dec 2013
Barnes L Parks C Bushmiaer M
Full Access

PURPOSE:. Wright Medical has a long history of modular neck hip implants but had fracture issues with the original titanium necks. They subsequently changed to chrome cobalt modular necks. Direct contact between these dissimilar metal parts in the modular femoral component brings into consideration the possibility of similar adverse reactions of metal-on-metal articulations that have been previously described in other designs. METHODS:. A retrospective review of 10 patients with Wright Medical chrome cobalt modular necks who were evaluated with chromium and cobalt metal ion levels as well as Metal Artifact Reduction Sequence (MARS) MRI's was performed. Pseudotumors were classified by MRI based on wall thickness, T1/T2 signal, shape, and location and given a corresponding type of I, II, or III. For each patient, symptoms or lack thereof were recorded, and time since surgery noted. RESULTS:. Of 10 patients tested, 9 were symptomatic, and 1 was asymptomatic. The patient that was asymptomatic at last clinical visit at 14 months post-op while symptomatic patients averaged 18 months since initial surgery before symptoms began. Those with metal-poly articulation had an average cobalt level of 1.6, ceramic-ceramic articulation had level of <1, and metal-on-metal had level of 2.9. Five patients had pseudotumor by MRI (2 type I, 1 type II, and 2 type III pseudotumors). CONCLUSION:. It appears that an unintended consequence of changing from titanium to chrome cobalt modular neck may be occurring secondary to corrosion at neck-stem junction. SIGNIFICANCE: This reaction does not appear to be design-specific as these findings are similar to our findings in Stryker Rejuvenate stems. Surgeons evaluating patients with these and other similar stems should be aware of this complication and consider ion testing and MARS MRI


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 353 - 353
1 Jul 2011
Plakogiannis C Theruvil B Sisak K Middleton R
Full Access

In revision of cemented femoral components, removal of cement can be challenging. This study evaluates the use of an ultrasonic device (OSCAR, Orthosonics Ltd UK) for cement removal. 30 consecutive patients that attended our outpatients\’ clinic between May 2008 and September 2008, who underwent revision THR by the senior author or his fellows, were retrospectively reviewed. Minimum follow up was 12 months (average 34.9 months).Indications were aseptic loosening and recurrent dislocation. A posterolateral approach was used routinely. Cement was removed with osteotomes and OSCAR. An uncemented modular femoral component was used. At follow-up, radiographs were evaluated for the evidence of extended trochanteric osteotomy (ETO), fracture, cortical perforation, component loosening, migration, and adequacy of cement removal. None of the cases required an ETO or cortical windowing. In 5 cases prophylactic cabling of the proximal femur was performed. There was one intraoperative femoral shaft fracture (3.33%). There was incomplete cement removal in 7 cases. There was no cortical perforation and no postoperative fracture. There was no case with loosening or migration of the implant. In all cases that OSCAR was used ETO and cortical windowing were avoided. At an average 34.9 month follow up there was no evidence of thermal tissue damage. In the cases that cement was retained in the canal, this did not affect the stability of the implant. The fracture and the incomplete cement removal were in cases performed by a fellow illustrating the learning curve of the technique


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 100 - 100
1 Mar 2013
Kohan L Field C Kerr D
Full Access

Comparisons of blood metal ion levels of cobalt and chromium (CoCr) between metal-on-metal total and resurfacing hip arthroplasties are limited. High levels of CoCr may result in long-term adverse biological effects. We compare metal ions levels between total and resurfacing implants. 70 patients (28 males and 42 females) had a total hip arthroplasty using the Birmingham (Smith & Nephew) modular femoral component and a variety of stems, articulating with the Birmingham resurfacing component. The average age was 65.5 (±6.8) years and an average follow-up of 6.0 (±2.2) years. 170 patients (145 male and 25 female had a Birmingham resurfacing arthroplasty with an average age of 54.7 (±9.9) years and an average follow-up of 5.9 (±3.0) years. CoCr levels were measured. Bivariate correlations and independent samples t-tests were applied to determine similarities and differences within and between groups. Average ion levels in total arthroplasty patients were: Co 114.17 (±94.01) nmol/L (range 2–414); and Cr 75.12 (±68.45) nmol/L (range 10–312). Average levels in hip resurfacing arthroplasty were: Co 55.98 (±79.5) nmol/L (range 7–505); and Cr 70.77 (±87.41) nmol/L (range 5–751). Both total and resurfacing groups showed significant correlations (p<0.01) between Co and Cr levels. A significant difference was observed between the total and resurfacing group Co levels (p<0.0001). No significant difference was shown between group Cr levels (p>0.672). The average total hip replacement CoCr levels were higher than the hip resurfacing levels. While the overall activity level may be higher in the resurfacing group, possibly the incidence of stop/start frequency may be higher in the total hip replacement group. Hip resurfacing arthroplasty average CoCr levels are lower than those of total hip replacement patients. Associations between Co and Cr metal ion levels are shown within each group. Co levels differ significantly between groups where Cr does not. Long-term follow-up of CoCr levels are required


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 405 - 406
1 Nov 2011
Kindsfater K Dennis D Politi J
Full Access

Introduction: Although use of modular femoral components in revision hip arthroplasty is widely accepted, many still question the need for modular versatility in primary THA. The purpose of our study was to examine in a large cohort the percentage of hips in which femoral component version was changed to optimize stability or avoid prosthetic impingement of the THA construct. We hypothesized that the percentage of hips needing version change in routine primary THA would be low. Methods: This prospective study analyzed 1000 consecutive primary THAs using a modular S-ROM (DePuy) stem performed by 3 surgeons at 3 institutions all via a posterior approach. Mean patient age at surgery was 57.5 years; 51.6% were male. The difference in version between the femoral sleeve placed anatomically and the femoral stem was recorded intra-operatively. Results: Femoral component version was changed in 47.9% of hips. Logistic regression analysis showed no correlation between the likelihood of changing stem version and patient age (p=0.87), gender (p=0.23), diagnosis (p=0.54), or surgeon (p=0.27). 10 hips (1%) experienced early dislocation (within 3 months post-op). With the numbers available, there was a slight trend of lower dislocation rate in hips where stem version was changed (0.6%) versus those in which it was not (1.5%, p=0.16, chi squared). Conclusion: The incidence of femoral version change in routine primary THA was much higher than expected. It was difficult to predict the need to alter version based on clinical variables including diagnosis. Thus, we conclude it may be advantageous to routinely use a stem that allows variable version as it is not possible to pre-operatively determine when changing version will be required. In addition, we surmise our low dislocation rate compared to historical controls of THA performed using a posterior approach was aided by the ability to adjust version in almost half of our patients


Aims

For rare cases when a tumour infiltrates into the hip joint, extra-articular resection is required to obtain a safe margin. Endoprosthetic reconstruction following tumour resection can effectively ensure local control and improve postoperative function. However, maximizing bone preservation without compromising surgical margin remains a challenge for surgeons due to the complexity of the procedure. The purpose of the current study was to report clinical outcomes of patients who underwent extra-articular resection of the hip joint using a custom-made osteotomy guide and 3D-printed endoprosthesis.

Methods

We reviewed 15 patients over a five-year period (January 2017 to December 2022) who had undergone extra-articular resection of the hip joint due to malignant tumour using a custom-made osteotomy guide and 3D-printed endoprosthesis. Each of the 15 patients had a single lesion, with six originating from the acetabulum side and nine from the proximal femur. All patients had their posterior column preserved according to the surgical plan.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 87 - 87
1 Feb 2020
Polster V Guttowski D Huber G Nuechtern J Morlock M
Full Access

Introduction. Revision of total knee endoprostheses (TKA) is increasing in number and causes rising healthcare costs. For constrained prostheses, the use of intramedullar femoral stems is standard. However, there is a big variety of available stem types with regard to length, type of fixation (cemented vs. hybrid) and fixation area (diaphyseal vs. metaphyseal). The aim of this biomechanical study was to investigate the primary stability of revision TKA with different stem types and different femoral bone defects, to find out whether smaller or shorter stems may achieve sufficient stability while preserving bone for re-revision. Methods. 30 right human femora were collected, fresh frozen and divided in six groups, matching for age, gender, height, weight and bone density. In group 1–3 a bone defect of AORI type F2a (15mm medial) and in group 4–6 a defect of AORI type F3 (25mm on both sides) was created. In all six groups the same modular femoral surface component (Endo-Model-W, Waldemar Link) was used, combined with different stem types (100/ 160 mm cemented / uncemented / standard/ anatomical with / without cone). Additionally, one trial was set up, omitting the modular stem. The correct fit of the implants was confirmed by fluoroscopy. After embedding, specimens were mechanically loaded 10mm medially and parallel to the mechanical femoral axis with an axial force of 2700N and a torsional moment of 5.6Nm at a flexion angle of 15° with respect to the coupled tibial plateau according to in-vivo gait load for 10,000 cycles (1Hz) in a servohydraulic testing machine (Bionix, MTS). The relative movement between implant, cement and distal femur was recorded using a stereo video system (Aramis3D,gom). An axial pull-out test at 1mm/min was performed after dynamic loading. Results. No clinical or radiological loosening of any configuration was observed. In all cases, relative movements were below 20µm and the differences between groups were very small. There were two cases, the trial without stem and one probe with short cemented stem with poor cementing technique (not included in the group result), which showed greatly increased relative movements. Pull-out test exhibited that forces of short stems with cones and uncemented anatomical cone stems with large defects (groups 4–6) were not significantly different to cemented stems in small defects. Discussion. Despite the high experimental load, even causing bone fracture in two cases, no difference between the investigated stem types concerning primary stability was found, partially probably due to the high inter-individual variations. Possible long-term differences cannot be assessed with in-vitro testing representing direct post-op situation, but the results might partially explain the controversial clinical observations and suggest further investigation on patient specific decisive parameters for implant choice. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_8 | Pages 36 - 36
1 May 2014
Kraay M
Full Access

Arthritis of the hip is a relatively common problem in patients with neuromuscular disorders due to muscle imbalance around the hip from weakness, paralysis, contractures and spasticity. Neuromuscular disorders such as cerebral palsy, Parkinson's disease, poliomyelitis, previous cerebrovascular accident (CVA) and Charcot arthropathy have been considered by many to be relative contraindications to total hip arthroplasty (THA). The presence of certain anatomic abnormalities (excessive femoral anteversion, acetabular dysplasia, leg length discrepancy (LLD) and coax valga) and significant soft tissue contractures, muscle imbalance, and muscular weakness make THA a challenging surgical procedure in this patient population, and can predispose to dislocation and poor functional outcome following surgery. THA can, however, result in substantial pain relief and functional improvement in patients with significant hip arthritis and neuromuscular disorders, and can be safely performed, provided certain technical considerations are addressed. The patient's motor strength and functional status (ambulatory vs. “sitter”) should be carefully assessed pre-operatively, since both of these factors may affect the choice of surgical approach and component position. Significant soft tissue contractures should be released at the time of surgery. Although these can be frequently performed “open”, percutaneous adductor tenotomy is occasionally necessary for patients with significant adduction contractures. Patients requiring significant soft tissue releases may benefit from 6 weeks of bracing to allow soft tissues to heal appropriately and minimise risk of dislocation during this period of time. Use of modular femoral components that allow for correction of excessive femoral anteversion, should be considered in patients with coexistent dysplasia and neuromuscular disease (i.e. CP or polio). Large femoral head components should also be considered in patients with increased risk factors for dislocation. Despite their obvious theoretical advantages, the use of large head metal on metal THAs should be used with extreme caution in view of growing concerns about these devices. Although constrained acetabular liners are associated with an increased risk of mechanical failure, their use should be strongly considered in patients with significant motor weakness or major soft tissue deficiencies. Meticulous soft tissue closure of the capsule of the hip is recommended, especially when performing THA through a posterior approach. Patients with neuromuscular disorders associated with spasticity and involuntary movements need to be optimally treated medically prior to and indefinitely after THA. There are limited reports of outcomes following THA in patients with neuromuscular disorders, however some generalisations based on underlying diagnosis can be made. Patients with cerebral palsy and polio frequently have acetabular dysplasia, excessive femoral anteversion and LLD, and although durability does not seem to be a major concern, dislocation and instability is relatively common and needs to be addressed. Durability and instability do not appear to be major concerns in patients with Parkinson's disease, however, these patients have frequent medical complications perioperatively and have deterioration in function over time due to the progressive nature of their underlying disorder. Patients with previous CVA also appear to have acceptable durability and dislocation risk, but are at high risk of developing heterotopic ossification postoperatively. Patients with Charcot arthropathy or myelodysplasia are at high risk of instability and appear to have limited functional improvement following THA. As a result, the consensus of opinion is that THA is contraindicated in patients with Charcot arthropathy and myelodysplasia