Advertisement for orthosearch.org.uk
Results 1 - 20 of 134
Results per page:
Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 57 - 57
7 Aug 2023
Gill J Brimm D McMeniman P McMeniman T Myers P
Full Access

Abstract

Introduction

Patient selection is key to the success of medial unicondylar knee arthroplasty (UKA). Progression of arthritis is the most common indication for revision. Various methods of assessing the lateral compartment have been used including stress radiography, radioisotope bone scanning, MRI, and visualisation at the time of surgery. Arthroscopy is another means of assessing the integrity of the lateral compartment.

Methods

We used per-operative arthroscopy as a means to confirm suitability for UKA in a consecutive series of 279 Oxford medial UKA. This study reports the long-term results of a previously published cohort of knees. Our series of UKA with per-operative arthroscopy (Group 1) was compared to all Oxford UKA (Group 2) and all UKA in the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR) (Group 3).


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 14 - 14
10 Feb 2023
Vertesich K Staats K Böhler C Koza R Lass R Giurea A
Full Access

The use of rotating hinge (RH) prostheses for severe primary as well as revision arthroplasty is widely established. Aim of this study was to investigate long term results of a new RH prosthesis (EnduRo®, B Braun, Germany), which uses carbon-fiber reinforced poly-ether-ether-ketone (CFR PEEK) as a new bearing material, first time used in knee arthroplasty.

Fifty-six consecutive patients, who received the EnduRo® RH prosthesis were included in this prospective study: 21 patients (37.5%) received the prosthesis as a primary total knee arthroplasty (TKA) and 35 patients (62.5%) underwent revision total knee arthroplasties (rTKA). Clinical and radiographic examinations were performed preoperatively as well as postoperatively after 3 and 12 months and annually thereafter. Min. Follow up was 7 and mean follow up 9,3 years. Clinical examination included Knee Society Score (KSS), Western Ontario and McMaster Osteoarthritis Index (WOMAC), Oxford Knee Score (OKS), and range of motion (ROM). Competing risk analysis was assessed for survival with respect to indication and failure mode.

KSS, WOMAC, OKS, and ROM significantly improved from the preoperative to the follow up investigations (p < 0.0001). There was no difference in clinical outcome between the primary and the revision group. The overall cumulative incidence for revision for any reason was 23.6% and the cumulative incidence for complications associated with failure of the prothesis was 5.6% at 7 years, respectively. Complications occurred more frequently in the revision group (p = 0.002).

The evaluated RH prosthesis provided reliable and durable results with a minimum follow-up of 7 years. Prosthesis survival was successful considering the complexity of cases. The use of this RH system in primary patients showed high survival rates. Long-term functional and clinical results proved to be satisfying in both revision and primary cases. No adverse events were associated with the new bearing material CFR-PEEK.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_10 | Pages 86 - 86
1 Oct 2022
McNally M Ferguson J Scarborough M Ramsden A Stubbs D Atkins B
Full Access

Aim

Excision of chronic osteomyelitis (cOM) creates a dead space which must be managed to avoid early recurrence of infection. Systemic antimicrobials cannot penetrate this space in high concentration so local therapy has become an attractive adjunct to surgery. This study presents the mid- long-term results of local therapy with gentamicin in a bioabsorbable ceramic carrier.

Method

A prospective series of 100 patients with Cierny & Mader Types III and IV cOM, affecting 105 bones, were treated with a single stage procedure, including debridement, deep tissue sampling, local and systemic antimicrobials, stabilization and immediate skin closure. cOM was confirmed with strict diagnostic criteria. Patients were followed up for a mean of 6.05 years (range 4.2–8.4 years).


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 39 - 39
19 Aug 2024
Zuke WA Hannon CP Kromka J Granger C Clohisy JC Barrack RL
Full Access

We previously reported the five to ten-year results of the Birmingham Hip Resurfacing (BHR) implant. The purpose of this study was to evaluate the survivorship, radiographic results, and clinical outcomes of the BHR at long-term follow-up.

We retrospectively reviewed 250 patients from the original cohort of 324 BHRs performed from 2006 to 2013 who met contemporary BHR indications. Of these, 4 patients died and 4 withdrew. From the 242 patients, 224 patients (93%) were available for analysis. Modified Harris hip score (mHHS) and University of California, Los Angeles (UCLA) scores were collected and compared to a matched total hip arthroplasty (THA) cohort. Mean follow-up was 14 years.

Survivorship free of aseptic revision was 97.4% and survivorship free of any revision was 96.0% at 15 years. Revisions included 3 periprosthetic joint infections, 2 for elevated metal ions and symptomatic pseudotumor, 2 for aseptic femoral loosening, and 1 for unexplained pain. The mean mHHS was 93 in BHR patients at final follow-up, similar to the THA cohort (p=0.44). The UCLA score was significantly higher for BHR patients (p=0.02), however there were equal proportions of patients who remained highly active (UCLA 9 or 10) in both groups, 60.5% and 52.2% (p=0.45) for BHR and THA respectively. Metal ion levels at long term follow-up were low (mean serum cobalt 1.8±1.5 ppb and mean serum chromium 2.2±2.0 ppb).

BHR demonstrated excellent survivorship in males less than 60 years of age at time of surgery. Clinical outcomes and activity levels were similar to THA patients. Failures related to the metal-on-metal bearing were rare and metal levels were low at long-term follow-up.

Level of evidence: III

Keywords: survivorship; hip arthroplasty; activity; metal-on-metal

Surface Replacement Arthroplasty demonstrates low revision rates and similar activity level compared to total hip arthroplasty at long-term follow-up.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 12 - 12
1 Nov 2021
Cordero-Ampuero J Velasco P
Full Access

To compare complications, survivorship and results in 2 groups of Furlong-HAP Active, one with ceramic-ceramic and the other with metal-XLPE friction pair

Prospective, non-randomized, comparison of 2 series of JRI uncemented prosthesis, implanted with identical protocol by 1 surgeon in 1 hospital from 2006 to 2014. Friction pair was ceramic (Biolox Forte or Delta) in 35 patients of 53.7+/−10.6 years (25–69) (21 males, 60%), and CrCo-XLPE in 65 cases of 69.0+/−8.9 years (42–81) (36 males, 55%); there were significant differences in age (p<0.00001) but not in sex (p=0.6565).

Head diameter: Ce-Ce with 19 of 28mm, 9 of 32 and 7 of 36mm; Me-PE with 63 of 28mm, 1 of 32 and 1 of 36. Follow-up averaged 10.5+/−3.1 years (1–15) in ceramic and 9.8+/−3.8 years (2–15) in XLPE group. Pearson, Fisher, Kolmogorov-Smirnov, Student, Mann-Whitney, calculated with the informatic tools Microsoft Excel 2007 and https://www.socscistatistics.com/tests/.

Complications in ceramic joints: 2 late infections (Fisher exact test=0.6101) (1 DAIR, 1 one-stage exchange); 1 dislocation (Fisher exact test=0.2549) (closed reduction); 1 Vancouver C fracture (ORIF) (Fisher exact test=0.6548). Complications in Me-XLPE joints: 2 late infections (Fisher=0.6101) (1 DAIR, 1 two-stage exchange); 7 dislocations (Fisher=0.2549) (2 early, open reduction) (5 late: 3 closed reduction, 1 cup revision, 1 constrained cup); 4 Vancouver B fractures (Fisher=0.6548) (2 intraoperative, cerclages; 2 late, exchange).

Final follow-up: Harris Hip Score averaged 93.2+/−13.7 (23–100) in ceramic and 94.3+/−8.7 (65–100) in XLPE joints (p=0.64552).

Wear: 0.06+/−0.38mm (0–1.5) in ceramic and 0.16+/−0.5mm (0–2) in Me-PE THAs (p=0.30302).

Osteolysis in Charnley-De Lee zones: 8 zones (6 patients) (17%) in ceramic cups, 25 zones (15 patients) (23%) in XLPE cups (p=0.980127).

Survivorship without any surgery or closed reduction after 15 years: 91.0% in ceramic joints, 83.8% in Me-XLPE joints.

Survivorship without component exchange after 15 years: 93.9% in ceramic joints, 93.6% in Me-XLPE joints.

At least after 10 years follow-up of Furlong-HAP Active, metal-XLPE and ceramic-ceramic joints present no significant differences in complications, clinical score, wear, acetabular osteolysis, or survivorship without component exchange. On the contrary, survivorship without any surgery or closed reduction is different because of the high rate of dislocation in 28mm metal-poly joints.


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 1 - 1
19 Aug 2024
Terhune EB Carstens MF Fruth KM Hannon CP Bedard NA Berry DJ Abdel MP
Full Access

The relative advantages and disadvantages of two-stage versus one-stage management of infected total hip arthroplasties are the current subject of intense debate. To understand the merits of each approach detailed information on the short and, importantly, longer-term outcomes of each must be known. The purpose of this study was to assess the long-term results of two-stage exchange arthroplasty for THAs in one of the largest series to date.

We identified 331 infected THAs treated with a two-stage exchange arthroplasty between 1993 and 2021 at a single institution. Patients were excluded if they had prior treatment for infection. Mean age at reimplantation was 66 years, 38% were female, and mean BMI was 30 kg/m2. PJI diagnosis was based on the 2011 MSIS criteria. A competing risk model accounting for death was utilized. Mean follow up was 8 years.

The cumulative incidence of reinfection was 7% at 1 year and 11% at 5 and 10 years. Factors predictive of reinfection included BMI>30 kg/m2 (HR 2; p=0.049), and need for a spacer exchange (HR 3.2; p=0.006). The cumulative incidence of any revision was 13% at 5 and 10 years. The cumulative incidence of aseptic revision was 3% at 1 year, 7% at 5 years, and 8% at 10 years. Dislocation occurred in 33 hips (11% at 10 years; 45% required revision). Factors predictive of dislocation were female sex (HR 2; p=0.047) and BMI<30 kg/m2 (HR 3; p=0.02). The mean HHS improved from 54 to 75 at 10 years.

In this series of 331 two-stage exchange arthroplasties performed for infected hips, we found a low aseptic revision rate (8%) and a low rate of reinfection (11%) at 10 years. These long-term mechanical and infection data must be kept in mind when considering a paradigm shift to one-stage exchanges.

Level of Evidence: Level III


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 9 - 9
1 Apr 2019
Fukuoka S Fukunaga K Taniura K Sasaki T Takaoka K
Full Access

Aims

Spontaneous osteonecrosis of the knee (SONK) mainly affects the medial femoral condyle, would be a good indication for UKA. The primary aim of this study was to assess the clinical, functional and radiographic outcomes at middle to long-term follow-up, of a consecutive series of fifty UKA used for the treatment of SONK. The secondary aim was to assess the volume of necrotic bone and determine if this influenced the outcome.

Patients and Methods

We reviewed 50 knees who were treated for SONK. Patients included ten males and 38 females. The mean age was 73 years (range, 57 to 83 years). The mean height and body weight were, respectively 153 cm (141 ∼171 cm) and 57 kg (35 ∼75kg). All had been operated on using the Oxford mobile-bearing UKA (Zimmer-Biomet, Swindon, United Kingdom) with cement fixation. The mean follow-up period was 8.4 years (range, 4 to 15years). We measured the size (width, length and depth) and the volume to be estimated (width x length x depth) of the necrotic bone mass using MRI in T1-weighted images.

The clinical results were evaluated using the Knee Society Scoring System (KSS) and Oxford Knee Score (OKS). The flexion angle of the knee was evaluated using lateral X-ray images in maximum flexion.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 100 - 100
1 Jul 2020
El-Husseiny M Masri BA Duncan C Garbuz D
Full Access

Fully constrained liners are used to treat recurrent dislocations or patients at high risk after total hip replacements. However, they can cause significant morbidities including recurrent dislocations, infections, aseptic loosening and fractures. We examine long term results of 111 patients with tripolar constrained components to assess their redislocation and failure rate.

The purpose of this study was to assess survivorship, complications and functional outcomes at a minimum 10 years after the constrained tripolar liners used in our institute.

We retrospectively identified 111 patients who had 113 revision tripolar constrained liners between 1998 and 2008. Eighty-nine were revised due to recurrent dislocations, 11 for pseudotumor with dysfunctional abductors, and 13 for periprosthetic infection with loss of soft tissue stabilizers. All patients had revision hip arthroplasty before the constrained liner was used: 13 after the first revision, 17 after the second, 38 after the third, and 45 had more than 3 revisions. We extracted demographics, implant data, rate of dislocations and incidence of other complications. Kaplan Meier curves were used to assess dislocation and failure for any reason. WOMAC was used to assess quality of life.

At 10 years, the survival free of dislocation was 95.6% (95%CI 90- 98), and at 20 years to 90.6% (95% CI 81- 95.5). Eight patients (7.1%) had dislocations of their constrained liners: 1 patient had simultaneous periprosthetic infection identified at the time of open reduction, and 1 patient sustained stem fracture 3 months prior to the liner dislocation. At 10 years, the survival to any further surgery was 89.4% (95% CI 82–93.8), and at 20 years, this was 82.5 (95% CI 71.9–89.3). Five patients (4.4%) had deep infection: 4 of these had excision arthroplasty due to failure to control infection, while 1 patient was treated successfully with debridement, exchange of mobile components and intravenous antibiotics. Two patients (1.8%) had dissociated rings that required change of liner, ring and head. Two patients (1.8%) had periprosthetic femoral fractures that were treated by revision stems and exchange of constrained liners. The mean WOMAC functional and pain scores were 66.2 and 75.9 of 100, respectively.

Constrained tripolar liners in our institute provided favourable results in the long term for recurrent dislocation hip arthroplasty with dysfunctional hip stabilizers. Infection in these patients can prove to be difficult to treat due to their poor soft tissue conditions from repeated surgeries. Comparing long terms results from other types of constrained liners is essential to evaluate these salvage liners.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 5 - 5
1 Apr 2018
Pitto R
Full Access

Ceramic-on-ceramic bearings are considered in several European and Asian countries a reliable alternative to metal-on-polyethylene, ceramic-on-polyethylene, or metal-on-metal (with small diameter heads) for total hip arthroplasty (THA) management. Reduced joint wear and limited peri-prosthetic osteolytic changes are the main reasons supporting the use of ceramic. So far, the available observational data show a low rate of revision following the use of Ceramic-on-Ceramic bearings, but concern remains regarding the risk of fracture and the prevalence of squeaking noises from the joint.

The objective of this study was to use a national arthroplasty registry to assess whether the choice of bearings – metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), or metal-on-metal (MoM) – is associated with differences in the risk of revision.

Data from primary THAs were extracted from the New Zealand Joint Registry over a 15-year period. 97,889 hips were available for analysis. The mean age of patients was 68 years (SD +/− 11 years), and 52% were women. The median followup period in this patient population was 9 years (range, 1 to 15 years).

The primary endpoint was revision for any reason. Inclusion criteria were degenerative joint disease (84,894), exclusion criteria were previous surgery, trauma, and any other diagnosis (12,566). We also excluded patients operated on with a Ceramic-on-Metal THA, because of the small recorded number (429).

There were 54,409 (64.1%) MoP, 16,503 (19.4%) CoP, 9,051 (10.7%) CoC and 4,931 (5.8%) MoM hip arthroplasties. 3,555 hips were revised during the 15-year observation period. A multivariate assessment was carried out including the following risks factors available for analysis: age, gender, surgeon experience, use of cement.

Analysis of bearing surface type and revision showed a statistically significant lower risk for CoC hips (265 THAs, p≤0.01) when compared with CoP (537 THAs, HR 1.07, CI 0,92–1,26), MoP (2186 THAs, HR 1.39, CI 1.19–1,62), and MoM (576 THAs, HR 2.15, CI 1.84–2.51). The 15-year follow-up Kaplan-Meier survival analysis shows a 92% revision-free rate for CoC THAs (Figure 1). In particular, CoC THAs showed the lowest rates of revision for dislocation and for deep infection, when compared with the other bearings.

This registry study showed that the bearing surface is associated with the risk of revision. MoM bearing surfaces showed a high rate of revisions, while CoC THAs showed the lowest rate of revision compared to other bearing surfaces. Low wear and less osteolysis are the possible reasons for reduced risk of revision for aseptic loosening. We postulate that the healthy, fibrotic synovial-like pseudocapsule found in CoC THAs preserves the long-term stability of the joint and reduces the bio-burden for late deep infection. Future studies with larger data sets and longer follow-up should continue to investigate this query.

For any figures or tables, please contact the authors directly.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_11 | Pages 64 - 64
1 Oct 2019
Figgie MP Blevins JL Krell EC Chiu Y Stimac JD Heyse TJ Abdel MP
Full Access

Introduction

Primary total knee arthroplasties (TKA) performed in younger patients raise concerns regarding the potential for accelerated polyethylene wear, aseptic loosening, and thus revision TKA at a younger age. The purpose of this study was to determine the long-term implant survivorship, functional outcomes, and pain relief of primary TKA performed in patients under 35 years of age.

Methods

A retrospective review of our institutional registry identified 185 TKAs performed in 119 patients under the age of 35 between 1985 and 2010. Medical records and radiographs were reviewed. Patients were contacted for two serial questionnaires in 2011–2012 and again in 2018. Implant survivorship was calculated using Kaplan-Meier survivorship curves and Cox proportional hazard model. The median age was 26.1 (21.5–30.1) years, with a BMI of 23.5 (20.4–26.6) kg/m2. Median follow-up was 13.9 (8.5–19.8) years.


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 82 - 82
1 Aug 2020
Addar A Hamdy RC Fassier F Jiang F Marwan Y Algarni N Montpetit K
Full Access

The use of intramedullary implants in Osteogenesis Imperfecta (OI) patients to treat and prevent fractures, non-unions and limb deformities has been well established. To serve this purpose different implants are available from non-telescoping rods such as Rush rods and Kirschner wires, to telescoping rods such as the Dubow-Bailey rod, the Sheffield rod and the Fassier-Duval (FD) rod (Pega Medical, Laval, Quebec, Canada). The purpose of this study is to report on the long-term results of the femoral Fassier-Duval rod.

A retrospective chart review of all patients with OI who underwent a femoral intramedullary Fassier-Duval rodding between 2002 and 2017 and followed for an average of 12 years at the Shriner's Hospital, Montreal, Quebec, Canada was performed.

A total of 81 patients underwent femoral FD rodding between 2002 and 2017. Twenty-seven children undergoing 83 procedures had completed a minimum 10-year follow up with complete charts and these were included here. The average follow up time was 12 years (10–15 years). Fifty procedures were initial rodding surgeries and 30 (36.1%) were revision surgeries. A total of 69 complications were reported in the medical record and confirmed on x-ray. The 3 most common complications were a bent rod 24 (34.8%), femur fracture 16 (23.2%) and loss of telescoping in 12 (17.4%) of patients. The 3 most common cause of revision were femur fracture 16 (53.3%), broken rod 5 (16.7%) and coxa vara in 3 (10%) of patients. The average time from initial surgery to the first revision was 5.9 years.

Long term performance of femoral FD rodding shows that despite improved functioning with these rods, certain complications are to be expected, most commonly a risk of femoral fracture requiring revision surgery.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 66 - 66
1 Oct 2019
Amstutz HC Duff MJL
Full Access

Introduction

Hip resurfacing arthroplasty (HRA) lost its popularity because of excessive wear of the ASR M/M design. Now that causes of wear have been identified, it remains an attractive treatment option for young patients because of its bone-conserving nature, the preservation of bone mineral density, a low dislocation rate, and its biomechanical precision.

Methods

We assessed the long-term clinical outcomes of 1074 patients (1321 hips) who were implanted with hybrid Conserve®Plus HRA, with 556 surgeries performed in patients younger than 50 years of age (average, 41.6 years) compared to 765 surgeries performed in patients 50 years or older (average, 58.1 years). 74% of the patients were male. There were no exclusion criteria. The <50 group had a larger proportion of dysplasia and hips operated during the first generation of surgical technique.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_8 | Pages 130 - 130
1 May 2016
Kweon S Kim T Kim J Jeong K
Full Access

Purpose

The purpose of this study is to evaluate the clinical outcomes and and radiological findings of primary total hip arthroplasty(THA) performed by using cemented polished femoral stem.

Materials and Methods

We retrospectively reviewed 91 hips (84 patients) that had undergone primary THA with cemented polished femoral stem after follow-up more than 10 years. The mean age at surgery was 57 years old (47 to 75). Mean follow up period was 12. 8 years(10.1 to 14). Clinical evaluation was performed using Harris hip score. The radiographic evaluation was performed in terms of the cementing technique, including of subsidence within the cement mantle, radiolucent lines at the cement-bone or cement-stem interface, cortical hypertrophy, and calcar resorption.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_13 | Pages 72 - 72
1 Oct 2018
El-Husseiny M Masri BA Duncan CP Garbuz DS
Full Access

Background

Fully constrained liners are used to treat recurrent dislocations or patients at high risk after total hip replacements. However, they can cause significant morbidities including recurrent dislocations, infections, aseptic loosening and fractures. We examine long term results of 111 patients with tripolar constrained components to assess their redislocation and failure rate.

Questions/purposes

The purpose of this study was to assess survivorship, complications and functional outcomes at a minimum 10 years after the constrained tripolar liners used in our institute.


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 47 - 47
1 Apr 2019
Luo Z Zhou Z Pei F
Full Access

Object

Although single-radius designs have theoretical advantages in some aspects, there has been a paucity of evaluation studies. The purpose of this study was to compare 10-year clinical, radiological, survivorship outcomes of single radius and multi radius posterior stabilized prosthesis in total knee arthroplasty(TKA) with Rheumatoid Arthritis (RA).

Method

In this retrospective observational study, we reviewed 240 patients (240 knees) with RA who underwent TKA between Oct 2005 and Dec 2007: SR group (120 patients, 120 knees, Stryker Scorpio NRG) and MR group (120 patients, 120 knees, Depuy sigma RP). A 1 : 1 matched case control study was conducted in two groups which were similar in terms of age, gender, BMI, ASA classification and operation team. Mean follow-up periods were 10.73±1.13 (range: 8–13) years and 10.82±1.09 (range: 7–13) years.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 235 - 235
1 Mar 2003
Bordokas A Smymis A Diamantopoulos A Loizides A Tzurbakis M
Full Access

The arthroscopic meniscal repair is being applied nowadays successfully in any longitudinal tear of the medial or the lateral meniscus wliicli is located in zones II and 111 (in consistency with the zones of menisci vascularity according to Miller, Wagner, Hamer).

The material of this study includes 68 consecutive cases of patients who underwent arthroseopic meniscal repair. Thirty four of them (50%) were in conjunction with anterior cruciate ligament tear, which was treated at the same time. The patients age ranged from 15 to 50 (average 30.5 years). The length of follow up averaged 30.1 months. In all cases ilic “inside out” technique was performed according to Jacobs – Staenbli method. Postoperatively, all the patients followed a particular program of rehabihtation with the aid of a controlled motion knee brace, immediate weight-bearing with the brace locked in 10°, and motion without weight – bearing from 10 to 90 degrees of flexion for the first six weeks. Weight – bearing in motion was followed after the sixth week.

The reexamination of the patients and the evaluation of the results was subjective and was performed according to the Lyshota score (average 95%). Recurrence occurred in 5 paiicms within 6 months, 3 of whom were submitted to menisccctomy. The rest of the patients returned to their former activities in a six month period.

The arthroscopic meniscal repair provides excellent results and should always be applied when there is an indication, because the salvage of the meniscus contributes -among others- to the prevention of degenerative articular cartilage disease (osteoarthrosis).


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_2 | Pages 6 - 6
1 Jan 2016
Goto T
Full Access

Objective

We performed total knee arthroplasty (TKA) without patella resurfacing in patients with osteoarthritis (OA) of the knee.

The purpose of the present study was to evaluate the clinical results and the appropriateness TKA without patella resurfacing.

Methods

A total of 61 patients (61 affected knees) who had undergone a Low Contact Stress mobile − bearing knee arthroplasty (LCS− TKA) (Depuy, Warsaw, IN. USA) 10 years or more before the present study were enrolled. The LCS− TKAs did not include patella resurfacing. The patients' mean age was 77.7 ± 6.1 years (range: 59−94 years). The mean follow-up period was 121 ± 2.4 months (range: 120−129 months). The clinical evaluation used the scoring system for OA of the knees issued by the Japanese Orthopaedic Association (JOA score). We defined patellofemoral (PF) pain, crepitation, patellar clunk syndrome, spin-out, and reoperation as complications. We also used X-Ray imaging to measure the component angle, patella height, lateral shift ratio, tilting angle, femorotibial angle, posterior condylar offset and joint line, and evaluated the localization of sclerotic changes in the patella.

All of the LCS− TKAs were performed by one surgeon using the midvastus approach. During the operation, the osteophyte around the patella was resected, and the osteophyte on the articular surface was shaped using a bone saw.

For statistical analysis we performed Mann-Whitney's U test and adopted a significance level of P<5%.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_3 | Pages 76 - 76
1 Jan 2016
Nakamura H Takahashi K Sato A Takai S
Full Access

Back ground

In 1970's, condylar type knee prosthese with anatomic design appeared, however, joint flexion was not satisfactory. Y/S II total knee arthroplasty (TKA) was developed to obtain deep flexion together with bilateral ligament balance in 1980. The articular surface of the tibial component was flattened to permit femoral shift posteriorily during knee flexion. Medial and lateral soft tissue release was determined by a unique ligament tensor both at flexion and extension. A metal tray was embedded in polyethylene, which had a shape of glasses frame. Though the usage of Y/SII TKA was finished in 1984, we here studied its long term surgical results using the Kaplan-Meyer method.

Study design

From 1988 to 1991, 122 knees were replaced by Y/SII TKA in 81 patients with rheumatoid arthritis (RA). Among them, 24 joints in 12 patients were examined directly. The average age of follow-up was 19.5 years. The survival rate was investigated according to medical records.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 345 - 345
1 Mar 2004
Bordokas A Diamantopoulos A Loizides A Georgilas I Tzurbakis M
Full Access

Aims: To evaluate the long-term results of arthroscopic meniscal repair of any longitudinal meniscal tear in red-red or red-white zone. Methods: 60 patients 30.5 years old average (range 15 to 50) underwent arthroscopic meniscal repair (Ç inside-out È technique, Jacobs-Staue-bli method, 1988) and were followed up 30.1 months on average. 34 patients (50%) had an additional ACL rapture, which was repaired at the same operation. Postoperatively, all patients followed a particular program of rehabilitation using a controlled motion knee brace: immediate weight-bearing with the brace locked in 10¡, motion without weight-bearing from 10 to 90 degrees of ßexion for the þrst six weeks and then weight-bearing in motion was allowed. Results: Patients were re-examined and average Lysholm score was 95, while recurrence occurred in 5 patients (7.3%) and 3 of them submitted to meniscectomy. The rest of the patients returned to their former activities in a six-month period, including those who underwent an ACL reconstruction. Conclusions: Arthroscopic meniscal repair has excellent functional results and should always be applied on any longitudinal meniscal tear in red-red or red-white zone. Additional ACL ruptures should be treated at the same time.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_III | Pages 196 - 196
1 Mar 2003
Salanova B Moreno P Boulot J
Full Access

Study design: To analyse the long term effect of Harrington Instrumentation and fusion to the lumbar spine in the treatment of idiopathic scoliosis.

Objectives: To demonstrate there is a relationship between the strategy used (determination of fusion area) and pain or degenerative changes.

Summary of background data: The literature has been fairly controversial in terms of pain and degenerative changes beyond a fusion for idiopathic scoliosis according as the lower level of fusion. This is the first study in which the results are analysed according as the “strategy used” and not the sole level of fusion.

Methods: 250 patients operated on by Harrington instrumentation were clinically and radiographically reviewed. Pain was classified (as Moskowitz and Moe). To be included they should have an idiopathic scoliosis, a minimum follow up of 20 years (mean 26, max 36), 37% over 30 years, had to have been under 20 years at the time of surgery, and should have a full set of radiographs.

Curves were classified according to our own classification (Salanova et al) 1973–2000 in single structural. Thoracic 114, thoraco-lumbar 21 and double structural thoracic and lumbar, true double major (52), false D.M. (45). The double thoracic was identified with permanent T1 tilt (18). On P.OP standing the lower level of fusion was identified: E.V. (Salanova et al 1973–2000) SV (King) other vertebra. On follow up radiographs standing coronal and sagittal, lumbar coronal and sagittal degenerative changes were evaluated, slipping lateral and sagittal, discopathy over 50% and classified as none, moderate, complete.

Results: Mean age at surgery 15 years + 6. Mean age at follow up 49 years. Ten patients were reoperated on for various reasons. Overall results: Pain none 70, episodic 82, frequent 42, permanent 46. Degenerative changes none 155, moderate 62, complete 23. These data were evaluated according to the strategy used; there is a strong statistical relationship between strategy and final results. Our study proves that King’s classification for so-called King II curves is misleading.

Conclusion: This study is the most important ever published in terms of patients, methodology, and follow up. It shows that if a clear analysis of curve(s) before surgery is effectuated for determination of fusion area, if for single curves the lower level of fusion is the good one and for double structural the choice between selective thoracic fusion and double fusion is correctly determinated the long term results are not so bad.