Purpose. The aim of the present study was to investigate the relationship between generalised
Purpose: This study was performed to assess the incidence of generalized
Purpose: This study was performed to assess the incidence of generalized
Introduction: This study was performed to assess the incidence of generalized
We review our results of arthroscopic capsular plication in patients with
We evaluated the clinical outcome of arthroscopic labroplasty in 56 patients treated for shoulder instability owing to
Purpose: To determine whether generalized
Introduction. While the use of stemmed implants is accepted for patients with medial
LCL laxity in the varus knee responds well to valgus correction with a high tibial osteotomy. LCL laxity secondary to malunion of a lateral tibial plateau fracture can be managed with an open wedge varus high tibial osteotomy
Varus distal femoral osteotomy was performed for isolated symptomatic MCL laxity. The average resultant anatomical axis was zero degrees. This resulted in loss of the medial thrust on weightbearing. Patients with injuries resulting in early medial OA with varus alignment and MCL laxity were treated with open wedge valgus high tibial osteotomy. The majority of patients with LCL laxity and varus alignment responded to closing wedge valgus high tibial osteotomy. A smaller number (six) with depression of the lateral tibial plateau two degrees to fracture and associated LCL laxity responded to open wedge varus high tibial osteotomy. ACL patients were followed for over two years (range two to four years) post-surgery. All patients were assessed clinically and radiographically. Clinical examinations included a Lysholm functional score and Tegner activity scale. Radiographic examination included pre- and post-operative three foot x-rays and pre-operation valgus, varus stem x-rays.
Gap balancing technique aims to achieve equal and symmetric gap at full extension and in flexion; however, little is known about the connection between the native and the replaced knee gaps. In this study, a novel robotic assisted ligament tensioning tool was used to measure the pre- and post- operative gaps to better understand their relationship when aiming for balance gaps in flexion and extension. The accuracy of a prediction algorithm for the post-operative gaps based on the native gap and implant alignment was evaluated in this study. The medial and lateral gap were smallest at full extension. The native gaps increase with flexion until 30 degrees where they plateaued for the remaining flexion range. The native lateral gap was larger than the medial gap throughout the flexion range. Planning for equal gaps at extension and flexion resulted with tightest gaps at these angle; however, the gaps in mid-flexion were 3–4 mm larger. Good agreement was observed between the post-operative results and the predicted gas from the software algorithm. The results showed that the native gaps are neither symmetric nor equal. In addition, aiming for equal gaps reduces the variation at these angles but could result in mid- flexion laxity. Advanced robotics-assisted instrumentation can aid in evaluation of soft-tissue and help in surgical planning of TKA. This allows the surgeon to achieve the targeted outcome as well as record the final implant tension to correlate with clinical outcomes.
We performed A total of 12 cadaveric lower limbs were tested with a commercial
image-free navigation system using trackers secured by bone screws.
We then tested a non-invasive fabric-strap system. The lower limb
was secured at 10° intervals from 0° to 60° of knee flexion and
100 N of force was applied perpendicular to the tibia. Acceptable
coefficient of repeatability (CR) and limits of agreement (LOA)
of 3 mm were set based on diagnostic criteria for anterior cruciate
ligament (ACL) insufficiency.Objectives
Methods
Conventional computer navigation systems using bone fixation have been validated in measuring anteroposterior (AP) translation of the tibia. Recent developments in non-invasive skin-mounted systems may allow quantification of AP laxity in the out-patient setting. We tested cadaveric lower limbs (n=12) with a commercial image free navigation system using passive trackers secured by bone screws. We then tested a non-invasive fabric-strap system. The lower limb was secured at 10° intervals from 0° to 60° knee flexion and 100N of force applied perpendicular to the tibial tuberosity using a secured dynamometer. Repeatability coefficient was calculated both to reflect precision within each system, and demonstrate agreement between the two systems at each flexion interval. An acceptable repeatability coefficient of ≤3 mm was set based on diagnostic criteria for ACL insufficiency when using other mechanical devices to measure AP tibial translation. Precision within the individual invasive and non-invasive systems measuring AP translation of the tibia was acceptable throughout the range of flexion tested (repeatability coefficient ≤1.6 mm). Agreement between the two systems was acceptable when measuring AP laxity between full extension and 40° knee flexion (repeatability coefficient ≤2.1 mm). Beyond 40° of flexion, agreement between the systems was unacceptable (repeatability coefficient >3 mm). These results indicate that from full knee extension to 40° flexion, non-invasive navigation-based quantification of AP tibial translation is as accurate as the standard invasive system, particularly in the clinically and functionally important range of 20° to 30° knee flexion. This could be useful in diagnosis and post-operative follow-up of ACL pathology.
Conventional computer navigation systems using bone fixation have been validated in measuring anteroposterior (AP) translation of the tibia. Recent developments in non-invasive skin-mounted systems may allow quantification of AP laxity in the out-patient setting. We tested cadaveric lower limbs (n=12) with a commercial image free navigation system using passive trackers secured by bone screws. We then tested a non-invasive fabric-strap system. The lower limb was secured at 10° intervals from 0° to 60° knee flexion and 100N of force applied perpendicular to the tibial tuberosity using a secured dynamometer. Repeatability coefficient was calculated both to reflect precision within each system, and demonstrate agreement between the two systems at each flexion interval. An acceptable repeatability coefficient of ≤3mm was set based on diagnostic criteria for ACL insufficiency when using other mechanical devices to measure AP tibial translation. Precision within the individual invasive and non-invasive systems measuring AP translation of the tibia was acceptable throughout the range of flexion tested (repeatability coefficient ≤1.6mm). Agreement between the two systems was acceptable when measuring AP laxity between full extension and 40° knee flexion (repeatability coefficient ≤2.1mm). Beyond 40° of flexion, agreement between the systems was unacceptable (repeatability coefficient >3mm). These results indicate that from full knee extension to 40° flexion, non-invasive navigation-based quantification of AP tibial translation is as accurate as the standard invasive system, particularly in the clinically and functionally important range of 20° to 30° knee flexion. This could be useful in diagnosis and post-operative follow-up of ACL pathology.
Conventional computer navigation systems using bone fixation have been validated in measuring anteroposterior (AP) translation of the tibia. Recent developments in non-invasive skin-mounted systems may allow quantification of AP laxity in the out-patient setting. We tested cadaveric lower limbs (n=12) with a commercial image free navigation system using passive trackers secured by bone screws. We then tested a non-invasive fabric-strap system. The lower limb was secured at 10° intervals from 0° to 60° knee flexion and 100N of force applied perpendicular to the tibial tuberosity using a secured dynamometer. Repeatability coefficient was calculated both to reflect precision within each system, and demonstrate agreement between the two systems at each flexion interval. An acceptable repeatability coefficient of ≤3mm was set based on diagnostic criteria for ACL insufficiency when using other mechanical devices to measure AP tibial translation. Precision within the individual invasive and non-invasive systems measuring AP translation of the tibia was acceptable throughout the range of flexion tested (repeatability coefficient ≤1.6 mm). Agreement between the two systems was acceptable when measuring AP laxity between full extension and 40° knee flexion (repeatability coefficient ≤2.1 mm). Beyond 40° of flexion, agreement between the systems was unacceptable (repeatability coefficient >3 mm). These results indicate that from full knee extension to 40° flexion, non-invasive navigation-based quantification of AP tibial translation is as accurate as the standard invasive system, particularly in the clinically and functionally important range of 20° to 30° knee flexion. This could be useful in diagnosis and post-operative follow-up of ACL pathology.
Introduction. Orthopedics is experiencing a significant transformation with the introduction of technologies such as robotics and apps. These, integrated into the post-operative rehabilitation process, promise to improve clinical outcomes, patient satisfaction, and the overall efficiency of the healthcare system. This study examines the impact of an app called Mymobility and intra-operative data collected via the ROSA® robotic system on the functional recovery of patients undergoing robot-assisted knee arthroplasty. Method. The study was conducted at a single center from 2020 to 2023. Data from 436 patients were included, divided into “active” patients (active users of Mymobility) and “non-active” patients. Clinical analyses and satisfaction surveys were carried out on active patients. The intra-operative parameters recorded by ROSA® were correlated with the Patient-Reported Outcome Measures (PROMs) collected via Mymobility. Result. Intra-operative data showed significant correlations with PROMs for the 48 active patients, highlighting the importance of parameters such as medial joint space and
Preoperative
Anterior cruciate ligament (ACL) injuries are among the most common and debilitating knee injuries in professional athletes with an incidence in females up to eight-times higher than their male counterparts. ACL injuries can be career-threatening and are associated with increased risk of developing knee osteoarthritis in future life. The increased risk of ACL injury in females has been attributed to various anatomical, developmental, neuromuscular, and hormonal factors. Anatomical and hormonal factors have been identified and investigated as significant contributors including osseous anatomy,
Abstract. Background. Multi-ligament knee injury is a rare but severe injury. Treatment strategies are challenging for most orthopedic surgeons & optimal treatment remains controversial. The purpose of our study was to assess clinico-radiological and functional outcomes after surgical management of multi-ligament knee injuries & to determine factors that could predict outcome of surgery. Materials And Method. It is a prospective observational study of 30 consecutive patients of Multi-ligament knee injury conducted between 2018–2020. All patients were treated surgically with single-stage reconstruction of all injured ligaments and followed standardized postoperative rehabilitation protocol. All patients were evaluated for Clinical (VAS score, laxity stress test, muscle-strength, range of motion), Radiological (stress radiographs) & Functional (Lysholm score) outcomes three times-preoperatively, post-operative 3 & 12 months. Results. At final follow up mean VAS score was 0.86±0.77. The anteroposterior & valgus-varus stress test showed
Patellofemoral instability is common injury and proximal soft tissue stabilisation via MPFL reconstruction or imbrication is the mainstay of treatment. The contribution of certain pathoanatomies to the failure of patellofemoral stabilisation is unknown. The purpose of this study was to analyse the failure rate of patellar stabilisation procedures in a large cohort as measured by re-dislocation of the patella. A secondary purpose was to identify the pathoantomical features that may have predisposed these patients to failure. Between May 2008 and March 2014, 207 MPFL reconstructions and 70 MPFL imbrications were performed by a single surgeon. Post-operative assessment included clinical examination to assess the integrity of the MPFL graft, plain radiographs and the Banff Patellofemoral Instability Instrument (BPII), a disease-specific outcome measure. Failures were identified and risk factors including trochlear dysplasia, patella alta, generalised
Purpose of Study. To investigate the proprioceptive function of patients with an ACL rupture before and after reconstruction and correlate these findings with