Advertisement for orthosearch.org.uk
Results 1 - 20 of 2471
Results per page:
Bone & Joint Open
Vol. 5, Issue 7 | Pages 550 - 559
5 Jul 2024
Ronaldson SJ Cook E Mitchell A Fairhurst CM Reed M Martin BC Torgerson DJ

Aims. To assess the cost-effectiveness of a two-layer compression bandage versus a standard wool and crepe bandage following total knee arthroplasty, using patient-level data from the Knee Replacement Bandage Study (KReBS). Methods. A cost-utility analysis was undertaken alongside KReBS, a pragmatic, two-arm, open label, parallel-group, randomized controlled trial, in terms of the cost per quality-adjusted life year (QALY). Overall, 2,330 participants scheduled for total knee arthroplasty (TKA) were randomized to either a two-layer compression bandage or a standard wool and crepe bandage. Costs were estimated over a 12-month period from the UK NHS perspective, and health outcomes were reported as QALYs based on participants’ EuroQol five-dimesion five-level questionnaire responses. Multiple imputation was used to deal with missing data and sensitivity analyses included a complete case analysis and testing of costing assumptions, with a secondary analysis exploring the inclusion of productivity losses. Results. The base case analysis found participants in the compression bandage group accrued marginally fewer QALYs, on average, compared with those in the standard bandage group (reduction of 0.0050 QALYs (95% confidence interval (CI) -0.0051 to -0.0049)), and accumulated additional mean costs (incremental cost of £52.68 per participant (95% CI 50.56 to 54.80)). Findings remained robust to assumptions tested in sensitivity analyses, although considerable uncertainty surrounded the outcome estimates. Conclusion. Use of a two-layer compression bandage is marginally less effective in terms of health-related quality of life, and more expensive when compared with a standard bandage following TKA, so therefore is unlikely to provide a cost-effective option. Cite this article: Bone Jt Open 2024;5(7):550–559


Bone & Joint Open
Vol. 4, Issue 2 | Pages 72 - 78
9 Feb 2023
Kingsbury SR Smith LKK Pinedo-Villanueva R Judge A West R Wright JM Stone MH Conaghan PG

Aims. To review the evidence and reach consensus on recommendations for follow-up after total hip and knee arthroplasty. Methods. A programme of work was conducted, including: a systematic review of the clinical and cost-effectiveness literature; analysis of routine national datasets to identify pre-, peri-, and postoperative predictors of mid-to-late term revision; prospective data analyses from 560 patients to understand how patients present for revision surgery; qualitative interviews with NHS managers and orthopaedic surgeons; and health economic modelling. Finally, a consensus meeting considered all the work and agreed the final recommendations and research areas. Results. The UK poSt Arthroplasty Follow-up rEcommendations (UK SAFE) recommendations apply to post-primary hip and knee arthroplasty follow-up. The ten-year time point is based on a lack of robust evidence beyond ten years. The term 'complex cases' refers to individual patient and surgical factors that may increase the risk for arthroplasty failure. For Orthopaedic Data Evaluation Panel (ODEP) 10A* minimum implants, it is safe to disinvest in routine follow-up from one to ten years post-non-complex hip and knee arthroplasty provided there is rapid access to orthopaedic review. For ODEP 10A* minimum implants in complex cases, or non-ODEP 10A* minimum implants, periodic follow-up post-hip and knee arthroplasty may be required from one to ten years. At ten years post-hip and knee arthroplasty, clinical and radiological evaluation is recommended. After ten years post-hip and knee arthroplasty, frequency of further follow-up should be based on the ten-year assessment; ongoing rapid access to orthopaedic review is still required. Conclusion. Complex cases, implants not meeting the ODEP 10A* criteria, and follow-up after revision surgery are not covered by this recommendation. Cite this article: Bone Jt Open 2023;4(2):72–78


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 27 - 27
7 Aug 2023
Akehurst H Stamatopoulos A Deo S
Full Access

Abstract. Introduction. Knee replacement surgery can greatly improve pain, disability, quality of life and ability to work. Socioeconomic deprivation is associated with multiple poor health outcomes, partly due to reduced access to services, including surgery. We investigated whether deprivation was associated with characteristics at presentation, and outcomes following knee arthroplasty. Methodology. We linked data from 2358 knee arthroplasty cases with the Index of Multiple Deprivation, and mortality data after mean 7.6 years follow up. A locally developed scoring system was used prospectively to categorise case complexity. Results. Most patients were from more affluent areas. Deprivation was associated with younger age, and increasing case complexity. There was a significant association between case complexity and mortality, while an independent association between deprivation and mortality could not be confirmed. Conclusion. Health inequalities may impact presentations and outcomes in knee arthroplasty. Patients from areas of socioeconomic deprivation present more complex cases, which may be a result of associated comorbidity and delayed presentation due to impaired access. As knee arthroplasty can improve disability and ability to work, its availability in deprived areas can play a role in the alleviation of health inequality


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 2 - 2
7 Aug 2023
Warder H Hall-Thompson B Sanders T Wright N Alford S Johnson D
Full Access

Abstract. The Montgomery ruling advocates patients be informed of ‘material risks’ of a procedure. With no guidelines for patients wishing to return to high activity levels after knee arthroplasty, we explore patient and surgeon perceptions in climbers. Ethical approval was granted by the University of Central Lancashire. Anonymous questionnaires were sent via email and social media to consultant knee arthroplasty surgeons and to climbers/mountaineers across the UK. Consultants were asked about advice given for patients who participate in climbing. Climbers were asked about their experiences of knee arthroplasty and return to activity. Of 33 knee arthroplasty surgeons, 11(33%) were firmly against any return to climbing, 10(30%) counselled against it, and 12(36%) were open to return to previous activity. Of 11(33%) surgeons who do not gather information about levels of climbing, 8 would not provide specific advice regarding risks of returning to sport. Of 28 climbers, only 5(18%) were informed to cease completely, with 11(39%) cautioned against and 12(43%) permitted to return. There was no correlation between the advice received and climbing ability post-operatively, (kappa=0.143,p=0.058), with a substantial agreement between ability 1-year post-operatively and currently, (kappa=0.689,p<0.001). There is a discrepancy between the advice given and received by climbers/mountaineers prior to knee arthroplasty, with ability post-operatively having no relationship to advice given. Climbing is possible at high level with no reported complications following knee arthroplasty. The 1-year time point is predictive of longer-term outcome. This information should help surgeons better inform their patients preoperatively


Bone & Joint Research
Vol. 11, Issue 8 | Pages 575 - 584
17 Aug 2022
Stoddart JC Garner A Tuncer M Cobb JP van Arkel RJ

Aims. The aim of this study was to determine the risk of tibial eminence avulsion intraoperatively for bi-unicondylar knee arthroplasty (Bi-UKA), with consideration of the effect of implant positioning, overstuffing, and sex, compared to the risk for isolated medial unicondylar knee arthroplasty (UKA-M) and bicruciate-retaining total knee arthroplasty (BCR-TKA). Methods. Two experimentally validated finite element models of tibia were implanted with UKA-M, Bi-UKA, and BCR-TKA. Intraoperative loads were applied through the condyles, anterior cruciate ligament (ACL), medial collateral ligament (MCL), and lateral collateral ligament (LCL), and the risk of fracture (ROF) was evaluated in the spine as the ratio of the 95. th. percentile maximum principal elastic strains over the tensile yield strain of proximal tibial bone. Results. Peak tensile strains occurred on the anterior portion of the medial sagittal cut in all simulations. Lateral translation of the medial implant in Bi-UKA had the largest increase in ROF of any of the implant positions (43%). Overstuffing the joint by 2 mm had a much larger effect, resulting in a six-fold increase in ROF. Bi-UKA had ~10% increased ROF compared to UKA-M for both the male and female models, although the smaller, less dense female model had a 1.4 times greater ROF compared to the male model. Removal of anterior bone akin to BCR-TKA doubled ROF compared to Bi-UKA. Conclusion. Tibial eminence avulsion fracture has a similar risk associated with Bi-UKA to UKA-M. The risk is higher for smaller and less dense tibiae. To minimize risk, it is most important to avoid overstuffing the joint, followed by correctly positioning the medial implant, taking care not to narrow the bone island anteriorly. Cite this article: Bone Joint Res 2022;11(8):575–584


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 121 - 121
2 Jan 2024
Liepe K Baehr M
Full Access

After knee replacement, therapy resistant, chronic synovitis is common and leads to effusion and pain. A cohort of 55 patients with 57 knee replacements and chronic synovitis underwent radiosynoviorthesis. In summary, 101 joints were treated using 182±9 MBq of 90Y-citrate. The number of radiosynoviorthesis ranged from 1 to 4 (53%, 21%, 23%, and 4%). Every patient received a 99mTc-MDP scintigraphy before and three months after every radiosynoviorthesis. Follow-up ranged from 5.7 to 86.7 months. For qualitative analysis, an four steps scoring was used (0 = no response or worsening, 1 = slight, 2 = good, 3 = excellent response). For quantification, the uptake was determined within the 99mTc-MDP scintigraphy soft tissue phase before and after therapy. At the end of long-term follow-up 27% of patients have an excellent, 24% good, 30% slight and 20% no response. The duration of response was 7.5±8.3 months (maximum 27 months). In repeated treatment, the effect after the first therapy was lesser than in patients who received a single treatment in total. However, three months after the last radiosynoviorthesis, patients with repeated treatment showed a similar effectiveness than single treated patients. At the end of long-term follow-up, patients with repeated radiosynoviorthesis had a higher effectiveness at similar duration response. In the 99mTc-MDP scan 65% of patients showed a reduction of uptake. When comparing subjective and objective response 78% of patients showed a concordance in both, symptoms and scintigraphy. Pilot histological analysis revealed that the synovitis is triggered by small plastic particles. Radiosynoviorthesis is effective in patients with knee replacement and chronic synovitis. It shows good subjective and objective response rates and long response duration. Repeated treatment leads to a stronger long-time response. The chronic synovitis is caused by plastic particles, which result from the abrasion of the polymeric inlay of endoprothesis


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 5 - 5
7 Jun 2023
Prakash R Abid H Wasim A Sharma A Agrawal Y
Full Access

The National Health Service produces over 500,000 tonnes of waste and 25 mega tonnes of CO2 annually. Operating room waste is segregated into different streams which are recycled, disposed of in landfill sites, or undergo costly and energy-intensive incineration processes. By assessing the quantity and recyclability of waste from primary hip and knee arthroplasty cases, we aim to identify strategies to reduce the carbon footprint of arthroplasty surgery. Data was collected prospectively at a tertiary orthopaedic hospital, in the theatres of six arthroplasty surgeons between April – July 2022. Fifteen primary total hip arthroplasty (THA) and 16 primary total knee arthroplasty (TKA) cases were included; revision and complex primary cases were excluded. Waste was categorised into non-hazardous waste, hazardous waste, recycling, sharps, and linens. Each waste category was weighed. Items disposed as non-hazardous waste were catalogued for a sample of 10 TKA and 10 THA cases. Recyclability of items was determined from packaging. Average total waste generated for THA and TKA were 14.46kg and 17.16kg respectively, with TKA generating significantly greater waste (p < 0.05). On average only 5.4% of waste was recycled in TKA and just 2.9% in THA cases. The mean recycled waste was significantly greater in TKA cases compared to THA, 0.93kg and 0.42kg respectively (p < 0.05). Hazardous waste represented the largest proportion of the waste streams for both TKA (69.2%) and THA (73.4%). On average TKA generated a significantly greater amount (11.87kg) compared to THA (10.61kg), p < 0.05. Non-hazardous waste made up 15.1% and 11.3% of total waste for TKA and THA respectively. In the non-hazardous waste, only two items (scrub brush packaging and sterile towel packaging) were identified as recyclable based on packaging. We estimate that annually total hip and knee arthroplasty generates over 2.7 million kg of waste in the UK. Through increased use of recyclable plastics for packaging, combined with clear labelling of items as recyclable, medical suppliers can significantly reduce the carbon footprint of arthroplasty. Our data highlight only a very small percentage of waste is recycled in total hip and knee arthroplasty cases


Bone & Joint Open
Vol. 2, Issue 1 | Pages 48 - 57
19 Jan 2021
Asokan A Plastow R Kayani B Radhakrishnan GT Magan AA Haddad FS

Cementless knee arthroplasty has seen a recent resurgence in popularity due to conceptual advantages, including improved osseointegration providing biological fixation, increased surgical efficiency, and reduced systemic complications associated with cement impaction and wear from cement debris. Increasingly younger and higher demand patients are requiring knee arthroplasty, and as such, there is optimism cementless fixation may improve implant survivorship and functional outcomes. Compared to cemented implants, the National Joint Registry (NJR) currently reports higher revision rates in cementless total knee arthroplasty (TKA), but lower in unicompartmental knee arthroplasty (UKA). However, recent studies are beginning to show excellent outcomes with cementless implants, particularly with UKA which has shown superior performance to cemented varieties. Cementless TKA has yet to show long-term benefit, and currently performs equivalently to cemented in short- to medium-term cohort studies. However, with novel concepts including 3D-printed coatings, robotic-assisted surgery, radiostereometric analysis, and kinematic or functional knee alignment principles, it is hoped they may help improve the outcomes of cementless TKA in the long-term. In addition, though cementless implant costs remain higher due to novel implant coatings, it is speculated cost-effectiveness can be achieved through greater surgical efficiency and potential reduction in revision costs. There is paucity of level one data on long-term outcomes between fixation methods and the cost-effectiveness of modern cementless knee arthroplasty. This review explores recent literature on cementless knee arthroplasty, with regards to clinical outcomes, implant survivorship, complications, and cost-effectiveness; providing a concise update to assist clinicians on implant choice. Cite this article: Bone Jt Open 2021;2(1):48–57


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_15 | Pages 84 - 84
7 Nov 2023
Jordaan K Coetzee K Charilaou J Jakoet S
Full Access

Orthopaedic surgery is a practical surgical specialization field, the exit exam for registrars remains written and oral. Despite logbook evaluation and surgical work-based assessments, the question remains: can registrars perform elective surgery upon qualification? In South Africa, obstacles to elective surgical training include the trauma workload, financial constraints, fellowships and the Covid pandemic. In hip and knee arthroplasty, new approaches like the direct anterior approach (DAA) and robotic-assisted knee surgery also contributed to the dilution of cases available for registrar training. There are concerns that orthopaedic registrars do not perform enough cases to achieve surgical proficiency. Review of the last 4 years of registrar logbooks in hip and knee arthroplasty surgery performed in a single tertiary academic hospital in South Africa. We included all primary total hip replacements (THR), total knee replacements (TKR) and hemiarthroplasties (HA) done for neck of femur (NOF) fractures between 1 April 2019 and 30 March 2023. Differentiation between registrar assisting, registrar performing with consultant supervision and registrar performing independent surgery was done. 990 hip arthroplasties (472 Primary THR, 216 NOF THR, 302 NOF HA) and 316 Primary TKR were performed during the study period. In primary elective THR the posterior approach was dominant and used in 76% of cases. In NOF THA the DAA was dominant used in 98% of cases. Primary TKR robotic-assisted technologies was used in 27% (n=94) cases. Registrars as the primary surgeon were the highest in NOF THA at 70% of cases and the lowest performing TKR at 25%. During 3-month rotations, an average registrar performed 12 (2 TKR and 10 THR) and assisted in 35 (10 TKR and 25 THR) cases. Despite the large number of arthroplasties operations being performed over the last 4-year period, the surgical cases done by registrars are below, the proposed minimal cases to provide surgical proficiency during their training period


Bone & Joint Open
Vol. 3, Issue 6 | Pages 510 - 514
1 Jun 2022
Hoggett L Frankland S Ranson J Nevill C Hughes P

Aims. Hip and knee arthroplasty is commonly performed for end-stage arthritis. There is limited information to guide golfers on the impact this procedure will have postoperatively. This study aimed to determine the impact of lower limb arthroplasty on amateur golfer performance and return to play. Methods. A retrospective observational study was designed to collect information from golfers following arthroplasty. Data were collected from 18 April 2019 to 30 April 2019 and combined a patient survey with in-app handicap data. Results. A total of 2,198 responses were analyzed (1,097 hip and 1,101 knee). Of the respondents, 1,763 (80%) were male and the mean age was 70 years (26 to 92). Hip arthroplasty was associated with a mean increase in handicap of 1.03 (95% confidence interval (CI) 0.81 to 1.25). No difference was seen between isolated leading or trailing leg (p = 0.428). Bilateral hip arthroplasty increased handicap (p < 0.001). Overall, 1,025 (94%) maintained or increased the amount of golf played, 258 (23.5%) returned to iron shots at six weeks, 883 (80%) returned to club competitions at six months, 18 (1.6%) had persistent pain, and 19 (1.7%) were unable to return to play. Knee arthroplasty was associated with a mean increase in handicap of 1.18 (95% CI 0.99 to 1.38). Trailing leg arthroplasty alone was associated with higher postoperative handicap (p = 0.002) as was bilateral surgery (p = 0.009). Overall, 1,009 (92%) maintained or increased the amount of golf played, 270 (25%) returned to iron shots at six weeks, 842 (76%) returned to club competition at six months, 66 (6%) had persistent pain, and 18 (1.6%) were unable to return to play. Conclusion. Hip and knee arthroplasty enables patients to maintain or increase the amount of golf played. The majority return to competitions within one year. Return to iron shots occurs from six weeks. A small increase in handicap following surgery is expected and is larger in patients undergoing bilateral surgery or those with knee arthroplasty to their trailing leg. Patients may still experience pain when playing golf. Cite this article: Bone Jt Open 2022;3(6):510–514


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 43 - 43
1 Dec 2022
Wong M Benavides B Sharma R Ng R Desy N
Full Access

Periprosthetic joint infection (PJI) occurs in 0.2-2% of primary hip and knee arthroplasty and is a leading cause of revision surgery, impaired function, and increased morbidity and mortality. Topical, intrawound vancomycin administration allows for high local drug concentrations at the surgical site and has demonstrated good results in prevention of surgical site infection after spinal surgery. It is a promising treatment to prevent infection following hip and knee arthroplasty. Prior studies have been limited by small sample sizes and the low incidence of PJI. This systematic review and meta-analysis was performed to determine the effectiveness of topical vancomycin for the primary prevention of PJI in hip and knee arthroplasty. A search of Embase, MEDLINE, and PubMed databases as of June 2020 was performed according to PRISMA guidelines. Studies comparing topical vancomycin to standard perioperative intravenous antibiotics in primary THA and TKA with a minimum of three months follow-up were identified. The results from applicable studies were meta-analysed to determine the impact of topical vancomycin on PJI rates as well as wound-related and overall complications. Results were expressed as odds ratios (ORs) and 95% confidence intervals. Nine comparative observational studies were eligible for inclusion. 3371 patients treated with 0.5-2g of topical vancomycin were compared to 2884 patients treated with standard care. Only one of nine studies found a significantly lower rate of PJI after primary THA or TKA (OR 0.09-1.97, p=0.04 for one study, p>0.05 for eight of nine studies), though meta-analysis showed a significant benefit, with vancomycin lowering PJI rates from 1.6% in controls to 0.7% in the experimental group (OR 0.47, p=0.02, Figure 1). Individually, only one of five studies showed a significant benefit to topical vancomycin in THA, while none of seven studies investigating PJI after TKA showed a benefit to topical vancomycin. In meta-analysis of our subgroups, there was a significant reduction in PJI with vancomycin in THA (OR 0.34, p=0.04), but there was no significant difference in PJI after TKA (OR 0.60, p = 0.13). In six studies which reported complication rates other than PJI, there were no significant differences in overall complication rates with vancomycin administration for any study individually (OR 0.48-0.94, p>0.05 for all studies), but meta-analysis found a significant difference in complications, with a 6.7% overall complication rate in controls compared to 4.8% after topical vancomycin, largely driven by a lower PJI incidence (OR 0.76, p=0.04). Topical vancomycin is protective against PJI after hip and knee arthroplasty. No increase in wound-related or overall complication rates was found with topical vancomycin. This meta-analysis is the largest to date and includes multiple recent comparative studies while excluding other confounding interventions (such as povidone-iodine irrigation). However, included studies were predominantly retrospective and no randomized-controlled trials have been published. The limited evidence summarized here indicates topical vancomycin may be a promising modality to decrease PJI, but there is insufficient evidence to conclusively show a decrease in PJI or to demonstrate safety. A prospective, randomized-controlled trial is ongoing to better answer this question. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 52 - 52
17 Apr 2023
Abram S Sabah S Alvand A Price A
Full Access

Revision knee arthroplasty is a complex procedure with the number and cost of knee revision procedures performed per year expected to rise. Few studies have examined adverse events following revision arthroplasty. The objective of this study was to determine rates of serious adverse events in patients undergoing revision knee arthroplasty with consideration of the indication for revision (urgent versus elective indications) and to compare these with primary arthroplasty and re-revision arthroplasty. Patients undergoing primary knee arthroplasty were identified in the UK Hospital Episode Statistics. Subsequent revision and re-revision arthroplasty procedures in the same patients and same knee were identified. The primary outcome was 90-day mortality and a logistic regression model was used to investigate factors associated with 90-day mortality and secondary adverse outcomes including infection (undergoing surgery), pulmonary embolism, myocardial infarction, stroke. Urgent indications for revision arthroplasty were defined as infection or fracture, and all other indications were included in the elective indications cohort. 939,021 primary knee arthroplasty cases were included of which 40,854 underwent subsequent revision arthroplasty, and 9,100 underwent re-revision arthroplasty. Revision surgery for elective indications was associated with a 90-day rate of mortality of 0.44% (135/30,826; 95% CI 0.37-0.52) which was comparable to primary knee arthroplasty (0.46%; 4,292/939,021; 95% CI 0.44-0.47). Revision arthroplasty for infection, however, was associated with a much higher mortality of 2.04% (184/9037; 95% CI 1.75-2.35; odds ratio [OR] 3.54; 95% CI 2.81-4.46), as was revision for periprosthetic fracture at 5.25% (52/991; 95% CI 3.94-6.82; OR 6.23; 95% CI 4.39-8.85). Higher rates of pulmonary embolism, myocardial infarction, and stroke were also observed in the infection and fracture cohort. These findings highlight the burden of complications associated with revision knee arthroplasty. They will inform shared decision-making for patients considering revision knee arthroplasty for elective indications. Patients presenting with infection of a knee arthroplasty or a periprosthetic fracture are at very high risk of adverse events. It is important that acute hospital services and tertiary referral centres caring for these patients are appropriately supported to ensure appropriate urgency and an anticipation for increased care requirements


Bone & Joint Open
Vol. 4, Issue 3 | Pages 129 - 137
1 Mar 2023
Patel A Edwards TC Jones G Liddle AD Cobb J Garner A

Aims. The metabolic equivalent of task (MET) score examines patient performance in relation to energy expenditure before and after knee arthroplasty. This study assesses its use in a knee arthroplasty population in comparison with the widely used Oxford Knee Score (OKS) and EuroQol five-dimension index (EQ-5D), which are reported to be limited by ceiling effects. Methods. A total of 116 patients with OKS, EQ-5D, and MET scores before, and at least six months following, unilateral primary knee arthroplasty were identified from a database. Procedures were performed by a single surgeon between 2014 and 2019 consecutively. Scores were analyzed for normality, skewness, kurtosis, and the presence of ceiling/floor effects. Concurrent validity between the MET score, OKS, and EQ-5D was assessed using Spearman’s rank. Results. Postoperatively the OKS and EQ-5D demonstrated negative skews in distribution, with high kurtosis at six months and one year. The OKS demonstrated a ceiling effect at one year (15.7%) postoperatively. The EQ-5D demonstrated a ceiling effect at six months (30.2%) and one year (39.8%) postoperatively. The MET score did not demonstrate a skewed distribution or ceiling effect either at six months or one year postoperatively. Weak-moderate correlations were noted between the MET score and conventional scores at six months and one year postoperatively. Conclusion. In contrast to the OKS and EQ-5D, the MET score was normally distributed postoperatively with no ceiling effect. It is worth consideration as an arthroplasty outcome measure, particularly for patients with high expectations. Cite this article: Bone Jt Open 2023;4(3):129–137


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_1 | Pages 19 - 19
1 Jan 2022
Bishnoi A Hughes M Godsiff S
Full Access

Abstract. Background. The use of tourniquet in knee arthroplasty is common but in recent times, it has initiated a debate on its use. Complications from use of tourniquet are well documented in literature but there is less evidence on thigh pain, blood loss and length of stay post arthroplasty. Methods. We included 62 patients undergoing knee arthroplasty either Unicondylar knee arthroplasty or total knee arthroplasty. Patients were allocated randomly in tourniquet and without tourniquet groups. Half of the patients had UKA and other half TKA. Thigh pain was recorded using Visual analogue scale on day 1, 2 and on discharge. A drop in pre-operative and post operative haemoglobin level was recorded too. Independent sample t-test was done to compare the difference between the 2 groups mainly, drop in haemoglobin, thigh pain, knee pain and length of stay. Results. The mean drop in haemoglobin was comparable and was not statistically significant. Thigh pain on day 1 in no tourniquet group had a mean value of 0 and statistically significant difference in thigh pain at day 1,2 and discharge. In subgroup analysis between TKA and UKA the latter had improved results. Conclusions. Knee arthroplasty surgery without the use of tourniquet provides less thigh pain in the post-operative period and there isn't any significant difference in post op haemoglobin drop. None of the patient required any blood transfusion. A trend of early discharge was noted too but probably due to sample size, it wasn't statistically significant


Bone & Joint Open
Vol. 3, Issue 4 | Pages 275 - 283
1 Apr 2022
Ross LA O'Rourke SC Toland G MacDonald DJ Clement ND Scott CEH

Aims. The aim of this study was to determine satisfaction rates after hip and knee arthroplasty in patients who did not respond to postoperative patient-reported outcome measures (PROMs), characteristics of non-responders, and contact preferences to maximize response rates. Methods. A prospective cohort study of patients planned to undergo hip arthroplasty (n = 713) and knee arthroplasty (n = 737) at a UK university teaching hospital who had completed preoperative PROMs questionnaires, including the EuroQol five-dimension health-related quality of life score, and Oxford Hip Score (OHS) and Oxford Knee Score (OKS). Follow-up questionnaires were sent by post at one year, including satisfaction scoring. Attempts were made to contact patients who did not initially respond. Univariate, logistic regression, and receiver operator curve analysis was performed. Results. At one year, 667 hip patients (93.5%) and 685 knee patients (92.9%) had undergone surgery and were alive. No response was received from 151/667 hip patients (22.6%), 83 (55.0%) of whom were ultimately contacted); or from 108/685 knee patients (15.8%), 91 (84.3%) of whom were ultimately contacted. There was no difference in satisfaction after arthroplasty between initial non-responders and responders for hips (74/81 satisfied vs 476/516 satisfied; p = 0.847) or knees (81/93 satisfied vs 470/561 satisfied; p = 0.480). Initial non-response and persistent non-response was associated with younger age, higher BMIs, and worse preoperative PROMs for both hip and knee patients (p < 0.050). Being in employment was associated with persistent non-response for hip patients (p = 0.047). Multivariate analysis demonstrated that younger age (p < 0.038), higher BMI (p = 0.018), and poorer preoperative OHS (p = 0.031) were independently associated with persistent non-response to hip PROMs. No independent associations were identified for knees. Using a threshold of > 66.4 years predicted a preference for contact by post (area under the curve 0.723 (95% confidence interval (CI) 0.647 to 0.799; p < 0.001, though this CI crosses the 0.7 limit considered reliable). Conclusion. The majority of initial non-responders were ultimately contactable with effort. Satisfaction rates were not inferior in patients who did not initially respond to PROMs. Cite this article: Bone Jt Open 2022;3(4):275–283


Bone & Joint Research
Vol. 12, Issue 10 | Pages 624 - 635
4 Oct 2023
Harrison CJ Plessen CY Liegl G Rodrigues JN Sabah SA Beard DJ Fischer F

Aims. To map the Oxford Knee Score (OKS) and High Activity Arthroplasty Score (HAAS) items to a common scale, and to investigate the psychometric properties of this new scale for the measurement of knee health. Methods. Patient-reported outcome measure (PROM) data measuring knee health were obtained from the NHS PROMs dataset and Total or Partial Knee Arthroplasty Trial (TOPKAT). Assumptions for common scale modelling were tested. A graded response model (fitted to OKS item responses in the NHS PROMs dataset) was used as an anchor to calibrate paired HAAS items from the TOPKAT dataset. Information curves for the combined OKS-HAAS model were plotted. Bland-Altman analysis was used to compare common scale scores derived from OKS and HAAS items. A conversion table was developed to map between HAAS, OKS, and the common scale. Results. We included 3,329 response sets from 528 patients undergoing knee arthroplasty. These generally met the assumptions of unidimensionality, monotonicity, local independence, and measurement invariance. The HAAS items provided more information than OKS items at high levels of knee health. Combining both instruments resulted in higher test-level information than either instrument alone. The mean error between common scale scores derived from the OKS and HAAS was 0.29 logits. Conclusion. The common scale allowed more precise measurement of knee health than use of either the OKS or HAAS individually. These techniques for mapping PROM instruments may be useful for the standardization of outcome reporting, and pooling results across studies that use either PROM in individual-patient meta-analysis. Cite this article: Bone Joint Res 2023;12(10):624–635


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_3 | Pages 6 - 6
23 Jan 2024
Mathai NJ D'sa P Rao P Chandratreya A Kotwal R
Full Access

Introduction. With advances in mobile application, digital health is being increasingly used for remote and personalised care. Patient education, self-management and tele communication is a crucial factor in optimising outcomes. Aims. We explore the use of a smartphone app based orthopaedic care management system to deliver personalised surgical experience, monitor patient engagement and functional outcomes of patients undergoing knee arthroplasty. Results. Over a 12-month period, 124 patients listed for knee arthroplasty were offered access to the app. Average patient age was 65.4 years (range 49 to 86). 13(10.4%) patients were over 80 years. Compliance with app usage was 86.4%. Compliance with post-operative exercises increased following a message through the app. The mean Oxford knee score improved from a pre-op value of 17 to 35 at a mean follow-up of 6 months. Mean numeric rating scale pain score reduced from 7 pre-operatively to 3 at the latest follow-up. 58 patients (46.7%) used the communication feature on the app (text messages, photos, video consultations), reducing telephone calls and patient foot fall in the hospital. Patient satisfaction with the app was very high. Conclusion. We found the virtual care system to be effective in providing patient education, prehabilitation and post-operative rehabilitation along with being an effective channel of communication between patients and the hospital team. Patient satisfaction and compliance was very high


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_2 | Pages 3 - 3
1 Mar 2022
Guta D Santini A Fountain J Scott S Rourke H Davidson J Folb J
Full Access

Aims. The International Consensus Meeting on Musculoskeletal Infection (ICM, Philadelphia 2018) recommended histology as one of the diagnostic tests although this is not routinely used in a number of UK hospitals. This study aims to explore the role of histology in the diagnosis of infection and whether it is of practical use in those cases where the microbiology samples are either diagnostically unclear or do not correspond to the pre-operative diagnosis or the clinical picture. Patients and Methods. We identified 85 patients who underwent revision knee arthroplasty for either septic or aseptic loosening and for whom both microbiology and histology samples were taken. The procedures were performed by the senior experienced surgeons specialised in revision knee arthroplasty in two centres from Liverpool. Each patient had a minimum of five tissue samples taken, using separate knife and forceps and each sample was divided in half and sent for microbiology and histology in different containers. Fifty-four patients (63.5%) underwent a single-staged revision; ten patients (11.8%) underwent the 1. st. stage of a two staged revision; eleven patients (12.9%) underwent the 2. nd. stage of a two staged revision; one patient (1.2%) underwent an additional revision stage; three patients (3.5%) were treated with a DAIR; three patients (3.5%) had a 2-in-1 revision; two patients (2.4%) had a debridement and polyethylene exchange; and one patient (1.2%) had an arthroscopy biopsy of knee replacement. The cost to process five microbiology samples for each patient was £122.45 on average and for the five histology samples was £130. Results. In 63.5% (n=54) the histology and microbiology confirmed an aseptic joint as suspected beforehand. In 8.2% (n=7) the histology result was the same as the microbiology result confirming infection as suspected beforehand. In 15.3% (n=13) where asepsis was suspected beforehand, one of the five microbiology samples unexpectedly grew an organism but all the histological samples showed no evidence of infection. In these cases, the histology result supported the diagnosis of the likelihood of a contaminant. In 5.9% (n=5) we found differences in the microbiology and histology in one sample and in 7.1% (n=6) the histology was different to the microbiology in more than one sample. Conclusions. In cases where the diagnosis of sepsis within a knee replacement is not in doubt due to pre-operative microbiology, we found no benefit in additional histology sampling. In 28.3% of the cases, the histology was of use in the diagnosis of infection in complex cases and a useful tool in the decision process for further management. In over half of the cases where the revision was for aseptic loosening, the histology result did not alter the management but 28.3% of cases that were thought to be aseptic, microbiology revealed at least one positive sample hence the histology was of use in making a final diagnosis, be that of infection, contamination or to rule out infection. Whilst histology is of use in the latter groups but not the aseptic group, these outcomes are not predictable until after the post-operative period hence histology is required in all these cases. Overall, the histology is a cheap test which is of benefit in the diagnosis of complex peri-prosthetic joint infection in one–third of cases and we support the ICM recommendation


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_3 | Pages 17 - 17
23 Feb 2023
Tay M Stone B Nugent M Frampton C Hooper G Young S
Full Access

Source of the study: University of Auckland, Auckland, New Zealand and University of Otago, Christchurch, New Zealand. Outcomes following knee arthroplasty are typically defined as implant survivorship at defined timepoints, or revision incidence over time. These estimates are difficult to conceptualise, and lack context for younger patients with more remaining years of life. We therefore aimed to determine a ‘lifetime’ risk of revision as a more useful metric for total (TKA) and unicompartmental knee arthroplasty (UKA). The New Zealand Joint Registry was used to identify 96,497 primary TKAs and 13,481 primary UKAs performed between 1999 and 2019. Patient mortality and revision incidence were also extracted. Estimates of lifetime risk were calculated using an actuarial lifetable method. The estimates were stratified by age and gender. Reasons for revision were categorised using previously published standardised definitions. The lifetime risk of UKA revision was two-fold higher than TKA across all age groups (range 3.7-40.4% UKA, 1.6-22.4% TKA). Revision risk was higher for males with TKA (range 3.4%-25.2% males, 1.1%-20% females), but higher for females with UKA (range 4.3%-43.4% vs. 2.9%-37.4% for males). Revision due to infections were higher for TKA (1.5% males, 0.7% females) compared with UKA (0.4% males, 0.1% females). The increased risk in younger UKA patients was associated with higher incidence of aseptic loosening (UKA 2%, TKA 1%) and ‘unexplained pain’ (UKA 2%, TKA 0.2%). The risk for UKA was two-fold higher than TKA, and this was partially explained by a higher proportion of revisions due to ‘unexplained pain’. For TKA, males had higher risk of revision, in contrast to UKA where females had higher risk; this gender difference was associated with higher incidence of infections with TKA. Younger age, gender and higher ASA status were also associated with increased lifetime risk of UKA revision. Lifetime risk of revision can provide a meaningful measure of arthroplasty outcomes to aid patient counselling


Bone & Joint Research
Vol. 12, Issue 9 | Pages 512 - 521
1 Sep 2023
Langenberger B Schrednitzki D Halder AM Busse R Pross CM

Aims. A substantial fraction of patients undergoing knee arthroplasty (KA) or hip arthroplasty (HA) do not achieve an improvement as high as the minimal clinically important difference (MCID), i.e. do not achieve a meaningful improvement. Using three patient-reported outcome measures (PROMs), our aim was: 1) to assess machine learning (ML), the simple pre-surgery PROM score, and logistic-regression (LR)-derived performance in their prediction of whether patients undergoing HA or KA achieve an improvement as high or higher than a calculated MCID; and 2) to test whether ML is able to outperform LR or pre-surgery PROM scores in predictive performance. Methods. MCIDs were derived using the change difference method in a sample of 1,843 HA and 1,546 KA patients. An artificial neural network, a gradient boosting machine, least absolute shrinkage and selection operator (LASSO) regression, ridge regression, elastic net, random forest, LR, and pre-surgery PROM scores were applied to predict MCID for the following PROMs: EuroQol five-dimension, five-level questionnaire (EQ-5D-5L), EQ visual analogue scale (EQ-VAS), Hip disability and Osteoarthritis Outcome Score-Physical Function Short-form (HOOS-PS), and Knee injury and Osteoarthritis Outcome Score-Physical Function Short-form (KOOS-PS). Results. Predictive performance of the best models per outcome ranged from 0.71 for HOOS-PS to 0.84 for EQ-VAS (HA sample). ML statistically significantly outperformed LR and pre-surgery PROM scores in two out of six cases. Conclusion. MCIDs can be predicted with reasonable performance. ML was able to outperform traditional methods, although only in a minority of cases. Cite this article: Bone Joint Res 2023;12(9):512–521