Advertisement for orthosearch.org.uk
Results 1 - 20 of 43
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 15 - 15
1 Jun 2012
Bramlett K Grover DR
Full Access

Purpose. Introduce an Integrated Approach for Orthopedic-Sports Medicine Practice and Patient Care Management that. Is built around effective and efficient surgical techniques, and patient care management processes. Integrates Operations and Service Excellence best practices with patient care management processes. Integrates orthopedic care delivery between outpatient clinic, pre-surgery, surgery, inpatient, (acute care) and post acute care settings. Delivers exceptional clinical, patient satisfaction and financial outcomes as validated by independent national healthcare benchmarking organization. Helps position Ortho-Sports medicine services for strategic growth. Is replicable to develop Ortho-Sports Medicine Centers of Excellence. Presentation illustrates the ‘Ten Elements’ approach to implement the Ortho-Sports Medicine Centers of Excellence and demonstrate the effectiveness of the approach with an outcomes study from over 1000 total knee arthroplasty (TKA) procedures. During the presentation, the speakers would share the key clinical, patient satisfaction, and financial outcomes achieved by the implementation of the best practices defined in our ‘Ten Elements’ approach. All performance data elements are collected, validated and analyzed by an independent third party, national healthcare benchmarking company. During the presentation Dr. Bramlett would elaborate on the surgical protocol, and the key differentiating steps in procedure technique from traditional approach that significantly enhances procedure effectiveness, efficiency and lowers the patient complication rate as demonstrated by benchmarking data. Speakers would further present the key elements of Total Knee Arthoplasty procedure that focus on patient education, patient participation in pre-surgical weight loss and pre-habilitation program, anesthesia approach, avoiding tourniquet use and deep veen thrombosis (DVT) risk reduction, early post operative patient ambulation and weight bearing, and post operative patient management approach. On average the ortho-sports medicine clinical of Alabama TKA patients are disharged from the hospital in 2.6 days, and experience 65 percent less complications than expected for a similar patient population and assume early control of their independent functionality


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_5 | Pages 118 - 118
1 Apr 2019
McKenna R Jacobs H Jones C Redgment A Talbot S Walter W Brighton R
Full Access

Introduction

In total knee arthroplasty, the aim is to relieve pain and provide a stable, functional knee. Sagittal stability is crucial in enabling a patient to return to functional activities. Knee implants with a medial pivot (MP) design are thought to more accurately reproduce the mechanics of the native joint, and potentially confer greater antero-posterior stability through the range of flexion than some other implant designs.

Aim

This study aims to compare the sagittal stability of four different total knee arthroplasty implant designs. Method

Comparison was made between four different implant designs: medial pivot (MP), two different types of cruciate retaining (CR1 and CR 2) and deep dish (DD). A cohort of 30 Medial Pivot (MP) knees were compared with matched patients from each of the other designs, 10 in each group. Patients were matched for age, body mass index and time to follow up.

Clinical examination was carried out by an orthopaedic surgeon blinded to implant type, and sagittal stability was tested using a KT1000 knee arthrometer, applying 67N of force at 30˚ and 90˚.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_18 | Pages 8 - 8
1 Nov 2016
Sargeant H Nunag P
Full Access

Tranexamic Acid (TA) has been shown to reduce transfusion rates in Total Knee Replacement (TKR) without complication. In our unit it was added to our routine enhanced recovery protocol. No other changes were made to the protocol at this time and as such we sought to examine the effects of TA on wound complication and transfusion rate.

All patients undergoing primary TKR over a 12 month period were identified. Notes and online records were reviewed to collate demographics, length of stay, use of TA, thromboprophylaxis, blood transfusion, wound complications and haemoglobin levels. All patients received a Columbus navigated TKR with a tourniquet. Only patients who received 14 days of Dalteparin for thromboprophylaxis were included.

124 patients were included, 72 receiving TA and 52 not. Mean age was 70. Four patients required a blood transfusion all of whom did not receive TA (p = 0.029). Mean change in Hb was 22 without TA and 21 with (p = 0.859). Mean length of stay was 6.83 days without Tranexamic Acid and 5.15 with (p < 0.001). 15% of patients (n=11) of the TA group had a wound complication, with 40% of patients (n=21) in the non TA group (p = 0.003). There was one ultrasound confirmed DVT (non TA group). No patients were diagnosed with pulmonary embolus.

In our unit we have demonstrated a significantly lower transfusion rate, wound complication rate and length of stay, without any significant increase in thromboembolic disease with the use of TA in TKR.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 12 - 12
1 Mar 2013
Tang Q Silk Z Hope N Ha J Ahluwalia R Williams A Gibbons C Church J
Full Access

To date, there are no clear guidelines from the National Institute of Clinical Excellence or the British Orthopaedic Association regarding the use of Autologous Blood Transfusion (ABT) drains after elective primary Total Knee Replacement (TKR). There is little evidence to comparing specifically the use of ABT drains versus no drain. The majority of local practice is based on current evidence and personal surgical experience.

We aim to assess whether the use of ABT drains effects the haemoglobin level at day 1 post-operation and thus alter the requirement for allogenic blood transfusion. In addition we aim to establish whether ABT drains reduce post-operative infection risk and length of hospital stay.

Forty-two patients undergoing elective primary TKR in West London between September 2011 and December 2011 were evaluated pre- and post-operatively. Patient records were scrutinised. The patient population was divided into those who received no drain post-operatively and those with an ABT drain where fluid was suctioned out of the knee in a closed system, filtered in a separate compartment and re-transfused into the patient.

Twenty-six patients had ABT drains and 4 (15.4%) required an allogenic blood transfusion post-operatively. Sixteen patients received no drain and 5 (31.3%) required allogenic blood. There was no statistical difference between these two groups (p=0.22). There was no statistical difference (p=0.75) in the average day 1 haemoglobin drop between the ABT drain and no drain groups with haemoglobin drops of 2.80 and 2.91 respectively. There was no statistical difference in the length of hospital stay between the 2 groups (p=0.35). There was no statistical difference (p=0.26) in infection rates between the 2 groups (2 in ABT drains Vs. 0 in no drains). Of the 2 patients who experienced complications one had cellulitis and the other had an infected haematoma, which was subsequently washed out.

The results identify little benefit in using ABT drains to reduce the requirement for allogenic blood transfusion in the post-operative period following TKR. However, due to small patient numbers transfusion rates of 31.3% in the ABT drain group Vs. 15.4% in the no drain group cannot be ignored. Therefore further studies including larger patient numbers with power calculations are required before a true observation can be identified.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 91 - 91
1 Mar 2006
Gunther T Major B Lakatos T
Full Access

Introduction: Nowdays most of the health services focus on the reduction of expenses and the shorter hospital stay. For the patients is also important the faster rehabilitation in work and in full self-sufficiency.

Patients and methods: Möller has published in 1997, that medial unicompartmental knee arthroplasty can be operated from a shorter mediopatellar approach. This technique is important not only for the shorter wound, but much more for the faster rehabilitation because of the preserve of the extensor mechanism of the knee.

Between April 2000 and December 2002 we performed the minimal invasive medial unicompartmental knee arthroplasty in 36 cases. Our results were evaluated by the HSS knee score. The average follow up time was 24.7 months. We have compared our results to a similar group in age, number and follow up time, who has been operated in the traditional approach.

Results: However the overall HSS results showed significant difference (95.3 & 84.8), we think that the subgroups presents the substance of it much better. There was significant difference in walking distance, stair climbing, range of movement and muscle power, and we did not find any significant difference in pain, transport, flexion contracture, instability, need for appliance and the varus-valgus deformity.

Conclusion: In those cases, where both the patients win with the shorther rehabilitation and also the health service saves money with the reduction of expenses the minimal invasive way of operation should be more often used.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_III | Pages 302 - 302
1 Mar 2004
Schmidt K Willburger R Wiese M Awakowicz A Heukamp M Weskamp S
Full Access

Aims: The purpose of this study was to determine whether patella replacement or RAP of the patella is advantageous in TKA.

Methods: 100 patients were recruited to enter a randomised, prospective, double blind clinical trial to determine the efþcacy of patellar resurfacing during total knee arthroplasty. All patients receive the same posterior cruciatesparing prosthesis, and all operations were performed by, or under the direct supervision of the þrst author. Evaluation consisted of the determination of the HSS-Score, the knee society scores, speciþc questions relating to patellafemoral symptoms, radiographs, measurement of torques and stability of one leg standing. All knees were followed at 3 month and 18 month postoperatively.

Results: There was no signiþcant difference between the two groups with regard to the HSS-Score, and the KS-scores. Excentric and concentric torques were higher in the group with RAP of the patella. One leg standing was more stable in the group with RAP of the patella. In both groups one patient complained of severe anterior knee pain. The patient with RAP of the patellar was treated successfully with secondary patella resurfacing.

Conclusions: The clinical outcome and the prevalence of anterior knee pain after TKA with the PFC-∑ knee was not inßuenced by whether or not the patella had been resurfaced. Force and balance are slightly better after TKA with RAP of the patella.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 40 - 40
1 Jan 2016
Suzuki M Shirasaka W Yamamoto E Uetsuki K Sakai M Nakamura J Sasho T Takahashi K
Full Access

Introduction

In total knee arthroplalsties, there are risks of revision surgeries because of aseptic loosening, polyethylene wear, and metal component breakage. The data such as model, type, size, and manufacturing companies are required at the time of revision surgeries. However, it is sometimes difficult to acquire such data due to patient's change of address and the elimination and consolidation of hospitals in the long-term. Therefore, we try to use the Radio Frequency IDentification (RFID) in the total knee joint system.

Materials and methods

The FerVID family (Fujitsu Co. Ltd., Tokyo, Japan) was prepared as the RFID tag. It was radio-resistant below the dose of 50kGy, which allowed gamma sterilization. The RFID tags were embedded into the anterior side of GUR 1050 UHMWPE inserts and 0.3wt% vitamin E blended UHMWPE. The UHMWPE inserts were manufactured by thecompression molding method at the maximum temperature of 220°C and the maximum compressive force of 245kgf/cm2. The manufactured inserts were implanted in fresh cadaveric knees. The tibial base plate was made of Ti6Al4V. The femoral components were made of Co-Cr-Mo or Ti-6Al-4V. Communication Performance was measured with the interrogator (DOTR-920 MHz-band, Tohoku Systems Support Co. Ltd., Miyagi, Japan). The transmission output was up to 1W. Received Signal Strength Indicator (RSSI) was measured 500 times at 15 mm away from the surface of skin in the extension and 90° flexion of the knee (Fig1).


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 55 - 55
1 Sep 2012
Wilson DA Dunbar MJ Fong J Glazebrook M
Full Access

Purpose

To compare Radiostereometric Analysis (RSA) and subjective outcomes of Total Knee Arthroplasty (TKA) and Total Ankle Arthroplasty (TAA).

Method

Twenty-five patients were recruited to receive TKA (Zimmer, NexGen LPS Trabecular Metal Monoblock) and 20 patients were recruited to receive TAA (DePuy, Mobility). The tibial component of the TKA and the tibial component of the TAA were followed for two years with RSA with exams postoperatively at six, 12 and 24 months. At two years, inducible displacement RSA at the knee and ankle was also performed. RSA outcomes measured were translations in the anterior-posterior, medial-lateral and distal-proximal directions of both implants. SF-36 outcome questionnaires were completed preoperatively and at each RSA follow-up with the outcome being the mental component score (MCS) and physical component score (PCS). Analysis of variance statistical testing was used to compare RSA outcomes and subjective outcomes.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_IX | Pages 13 - 13
1 Mar 2012
Kulkarni A Jameson S James P Woodcock S Reed M
Full Access

Background

Total Knee Replacement (TKR) is technically demanding, time consuming and has higher complication rates in super obese (BMI>45) patients. Bariatric surgery can be considered for such patients prior to TKR although its effect on complications is unknown.

Methods

All patients who underwent bariatric surgery and a TKR in the NHS in England between 2005 and 2009 were included. Hospital episode statistics data in the form of OPCS, ICD10 codes were used to establish 90-day DVT, PE and mortality rates (inpatient and outpatient). In addition, readmission to orthopaedics, joint revision and ‘return to theatre for infection’ rates were also established. Code strings for each patient were examined in detail to ensure the correct gastric procedures were selected. Fifty-three patients underwent bariatric surgery then TKR (44-1274 days) (group 1). Thirty-one patients underwent TKR then bariatric surgery (33-1398 days) (group 2).


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 23 - 23
1 Dec 2013
Fiacchi F Catani F Digennaro V Gialdini M Grandi G
Full Access

Orthopaedic surgeons and their patients continue to seek better functional outcomes after total knee replacement, but TKA designs claim characteristic kinematic performance that is rarely assessed in patients.

The objectives of this investigation is to determine the in vivo kinematics in knees with Cruciate Retaining TKA using Patient Specific Technology during activities of daily living and to compare the findings with previous studies of kinematics of other CR TKA designs.

Four knees were operated by Triathlon CR TKA using Patient Specific Technology and a fluoroscopic measurement technique has been used to provide detailed three-dimensional kinematic assessment of knee arthroplasty function during three motor tasks. 3D fluoroscopic analysis was performed at 4-month follow-up.

The range of flexion was 90°(range 5°–95°) during chair-rising, 80°(range 0°–80°) during step up and 100° (range 0°–100°) during leg extension. The corresponding average external rotation of the femur on the tibial base-plate was 7.6° (range +4.3°; +11.9°), 9.5° (+4.0°; 13.5°) and 11.6° (+4.5°; +16.1°). The mean antero-posterior translations between femoral and tibial components during the three motor tasks were +4.7 (−3.7; +1.0), +6.4 (−3.8; +2.6) and +8,4 (−4.9; +3.5) mm on the medial compartment, and −2.5 (−7.1; −9.6), −3.6 (−6.1; −9.7), −2.6 (−7.7; −10.3) mm on the lateral compartment, respectively, with the medial condyle moving progressively anterior with flexion, and the medial condyle moving progressively posterior with flexion.

We compared Triathlon CR PSI TKA results from this study with Genesis II CR TKA, with Duracon CR TKA, with Triathlon CR TKA and with the healthy knee kinematics. The results of this study showed no screw home mechanism. The internal rotation of the tibia with knee flexion is close to normal, better than Genesis II, Duracon and Triathlon CR TKA operated with standard surgery.

The medial condyle is characterized by the same pattern of the other implants, with a paradoxical anterior translation of 5 mm.

The lateral condyle shows a posterior rollback better than Triathlon CR operated with standard surgery.

For the first time is demonstrated that the surgical technique can modify the tibio-femoral kinematics.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 540 - 540
1 Oct 2010
Stein HL Espehaug B Furnes O Leif IH Stein EV
Full Access

Background and purpose: Development of minimal invasive operation techniques has given unicompartemental knee arthroplasty (UKA) renewed interest. Indications for use of UKA are however debated, and short-term advantages of UKA over total knee arthroplasty (TKA) should be weighed against the higher risk of reoperation. More knowledge on long term results of pain and function after knee arthroplasties is therefore needed and was the purpose of this study.

Methods: Patient-reported pain and function were collected at least two years after the operations in postal questionnaires from 1643 osteoarthritis patients reported to the Norwegian Arthroplasty Register with intact primary TKA (n=1271) or UKA (n=372). The questionnaire contained instruments for calculation of the knee specific Knee Osteoarthritis Outcome Score (KOOS), and for quality of life (EQ-5D, post- and pre-operative). 5 subscales from KOOS were used as outcome. To incorporate an outcome for anterior knee pain an additional subscale based on 7 questions from KOOS, clinically accepted to be related to such discomfort, was calculated. Pain and satisfaction from a visual analogue scale (VAS) were also used as outcomes together with improvement in EQ-5D index score. The outcomes were measured on a scale from 0 (worst) to 100 (best) units with an argued minimal perceptible clinical difference of 8–10 units. Group differences were analysed with multiple linear regression, adjusted for confounding by age, gender, Charnley category, time since operation and preoperative EQ-5D index score.

Results: UKA performed better than TKA for the KOOS subscales Activity in Daily Living (difference in mean outcome score =−3.4,p=0.02) and Sport and Recreation (difference =−4.4,p=0.02) and for Anterior Pain (difference=−4.5,p< 0.01). The difference was also significant for the outcome Pain(VAS) but now in favour of TKA (difference=3.3,p=0.02). Motivated by the discrepancy in the results of the pain related outcomes, Anterior Pain (UKA best), Pain(VAS) (TKA best) and Pain(KOOS) (no difference) further investigation of the questions (0=best to 4=worst) used for calculation of Pain(KOOS) and Anterior Pain were performed. Patients that had undergone UKA had more often pain from the knee (difference=0.26,p< 0.01), while they had less pain when they were bending the knee fully (difference=−0.37,p< 0.01) and less problems when squatting (difference=−0.25,p< 0.01).

Interpretation: Estimated differences did not reach the level of minimal perceptible clinical difference. There are however indication of differences in the way the two treatment groups experience knee related discomfort. Even though UKA offers a lower level of pain and less problems in activities involving bending of the knee, these patients seem to experience pain from the knee more often.


Full Access

Background

Post operative analgesia is an important part of Total Knee Arthroplasty (TKA) to facilitate early mobilisation and patient satisfaction. We investigated the effect of periarticular infiltration of the joint with chirocaine local anaesthetic (LA) on the requirement of analgesic in the first 24 hrs period post op.

Methods

Retrospective analysis of case notes was carried out on 28 patients, who underwent TKA by two different surgeons. They were divided into two groups of 14 each; who did and did not receive the LA infiltration respectively. All patients were given spinal morphine (162 mcg r: 150-200). Analgesic requirement was assessed in terms of the amount of paracetamol, morphine, diclofenac, oxynorm and tramadol administered in 24hrs post op including the operating time.


The Bone & Joint Journal
Vol. 97-B, Issue 10_Supple_A | Pages 16 - 19
1 Oct 2015
Oussedik S Abdel MP Cross MB Haddad FS

Many aspects of total knee arthroplasty have changed since its inception. Modern prosthetic design, better fixation techniques, improved polyethylene wear characteristics and rehabilitation, have all contributed to a large change in revision rates. Arthroplasty patients now expect longevity of their prostheses and demand functional improvement to match. This has led to a re-examination of the long-held belief that mechanical alignment is instrumental to a successful outcome and a focus on restoring healthy joint kinematics. A combination of kinematic restoration and uncemented, adaptable fixation may hold the key to future advances.

Cite this article: Bone Joint J 2015;97-B(10 Suppl A):16–19.


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_4 | Pages 50 - 50
1 Apr 2018
Hafez M Cameron R Rice R
Full Access

Background. Surgical wound closure is not the surgeon”s favorite part of the total knee arthroplasty (TKA) surgery however it has vital rule in the success of surgery. Knee arthoplasty wounds are known to be more prone to infection, breakdown or delayed healing compared to hip arthroplasty wounds, and this might be explained by the increased tensile force applied on the wound with knee movement. This effect is magnified by the enhanced recovery protocols which aim to obtain high early range of movement. Most of the literature concluded that there is no difference between different closure methods. Objectives. We conducted an independent study comparing the complication rate associated with using barbed suture (Quill-Ethicon), Vicryl Rapide (polyglactins910-Ethicon) and skin staples for wound closure following TKA. Study Design & Methods. Retrospective study where the study group included all the patients admitted to our unit for elective primary knee arthroplasty in 2015, we excluded patients admitted for partial knee arthroplasty, revision knee arthroplasty or arthroplasty for treatment of acute trauma due to the relatively higher complication rates. All the patients notes were reviewed to identify wound related problems such as wound dehiscence, wound infection and delayed healing (defined as delayed wound healing more than 6 weeks). Results. 327 patients were included in this study; 151 in Quill group, 99 in staples group and 77 in the last group where the wound closed with Rapide. We identified 9 (5.9%) cases of wound dehiscence in the Quill group, 3 cases of wound dehiscence in each of other two groups (3.8%) with Rapide and (3%) with staples. On the other hand superficial wound infection was higher with staples with 6 (6%) cases of wound infection compared to the other groups, wound infection occurred in 2 patients (2.5%) with Rapide and 5 patients (3.3%) in the Quill”s group. Most of the delayed wound healing happened after using Quill where it is reported in 5 patients (3.3%) and the lowest was in staples group with 1 patient (1%) and slightly higher percentage in Rapide group 2 patients (2.5%). The total figure of wound related problems was the highest in Quill”s group with 19 reported cases (12.5%), lower in staples” group with 10 cases (1.1%) and the lowest in Rapide”s group with 7 cases (9%). Conclusions. Our study showed different results to the reported literature suggesting that each closure method has its own advantages and disadvantages. Quill is quick, knotless and absorbable but on the other side it is significantly more expensive than other alternatives and it is associated with the highest complication rates. On the other hand Rapide is cheap absorbable alternative with the lowest percentage of wound problems but on the negative side it is time consuming. Finally staples method is the quickest, relatively cheap and rarely associated with wound dehiscence but it is not absorbable which might cause inconvenience to patients


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_4 | Pages 130 - 130
1 Jan 2016
Wilson C Stevens A Mercer G Krishnan J
Full Access

Alignment and soft tissue balance are two of the most important factors that influence early and long term outcome of total knee arthroplasty. Current clinical practice involves the use of plain radiographs for preoperative planning and conventional instrumentation for intra operative alignment. The aim of this study is to assess the Signature. TM. Personalised system using patient specific guides developed from MRI. The Signature. TM. system is used with the Vanguard. R. Complete Knee System. This system is compared with conventional instrumentation and computer assisted navigation with the Vanguard system. Patients were randomised into 3 groups of 50 to either Conventional Instumented Knee, Computer Navigation Assisted Knee Arthroplasty or Signature Personalised Knee Arthoplasty. All patients had the Vanguard Total knee Arthroplasty Implanted. All patients underwent Long leg X-rays and CT Scans to measure Alignment at pre-op and 6 months post-op. All patients had clinical review and the Knee Society Score (KSS) at 1 year post surgery was used to measure the outcome. A complete dataset was obtained for 124 patients. There were significant differences in alignment on Long leg films ot of CT scan with perth protocol. Notably the Signature group had the smallest spread of outliers. In conclusion the Signature knee system compares well in comparison with traditional instrumentation and CAS Total Knee Arthroplasty


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 51 - 51
1 Jan 2016
Branovacki G Yong D Prokop T Redondo M
Full Access

Purpose. Traditional total knee arthoplasty techniques have involved implantation of diaphyseal stems to aid in fixation expecially when using constrained polyethylene inserts. While the debate over cemented vs uncemented stems continues, the actual use of stems is considered routine. The authors' experience with cemented stemmed knee revisions in older patients with osteoporotic bone has been favorable. Our younger patients with press-fit stems from varying manufacturers have been plagued with a relatively high incidence of component loosening and stem tip pain in the tibia and occasionally thigh. We report the early results of the first 20 total knee revisions using press-fit metaphyseal filling sleeved stemless implants with constrained bearings. Methods. Twenty three patients with failed primary or revision total knees were assigned to receive stemless sleeved revision knee designs using the DePuy MBT/TC3 system. Reasons for revision included loosening, implant fracture, stiffness, instability, and stem pain. Twenty patients (ages ranging from 42–73) were successfully reconstructed without stems. Six knees with significant uncontained cavitary defects were included. Three patients with unexpectedly osteoporotic metaphyseal bone were revised with cemented stemmed implants and excluded. All cases used cement for initial fixation on the cut bone surface and fully constrained mobile bearing inserts. Results. Follow up ranged from six months to three years. All patients had radiographic evidence of well fixed stable implants on most recent examination. All four cases of revision for “end of stem pain” had complete resolution of symptoms within two weeks of revision surgery. Long leg anterior posterior mechanical alignment x-rays measured within two degrees of neutral in all cases. Knee Society Scores improved an average of 34 points. Clinical results for revision for stiffness had the lowest final scores post operatively. Conclusion. Stemmed total knee arthroplasty revision implants with or without cement are considered the standard for most revision reconstructions. Recently, primary total hip replacements using newer short metaphyseal stems have shown promising early clinical results. This case series of twenty total knee revisions using stemless press-fit metaphyseal sleeves shows similarly favorable outcomes. The complications of stemmed implants such as stem tip pain and difficulty of cemented stem removal can be avoided successfully in non-osteporotic bone reconstructions. With stable bony ingrowth visible on early post-operatyive radiographs, long term stable fixation even with constrained bearings is expected. Longer follow up will be needed to validate this technique for routine use


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_7 | Pages 13 - 13
1 May 2016
Al-Khateeb H Hassan Z Salim H Zahar A Klauser W Gehrke T
Full Access

Background. Cement restrictors are used for maintaining good filling and pressurization of bone cement during hip and knee arthroplasties. The limitations of certain cement restrictors include the inability to accommodate for large medullary canals particularly in revision procedures. We describe a technique using SurgicelTM (Johnson & Johnson) and SPONGOSTAN™ (Johnson & Johnson) (Fig 1) to form a cement restrictor that can accommodate for large canal diameters and provide excellent pressurisation. Technique. The technique involves the application of SPONGOSTAN™ (Johnson & Johnson) foam onto a SurgicelTM (Johnson & Johnson) mesh which is then rolled onto the SPONGOSTAN™ foam forming a uniform cylindrical structure Figs 2,3. The diameter of the restrictor can be adjusted according to the desired femoral canal diameter through increasing the thickness of the SPONGOSTAN™ (Johnson & Johnson) foam. The restrictor is then inserted into the desired position in the medullary canal where it expands uniformly creating an effective restrictor and bone plug Fig 4. Bone cement is then applied and pressurisation commenced prior to the insertion of the implant Fig5. SPONGOSTAN™ is an absorbable haemostatic sponge intended for haemostatic use by applying to a bleeding surface. It consists of a sterile, water-insoluble, malleable, porcine gelatin absorbable sponge. Surgicel ™ is an absorbable hemostatic agent composed of oxidized regenerated cellulose. It is a sterile, absorbable knitted fabric that is flexible and adheres readily to bleeding surfaces. Both products are routinely used for their haemostatic properties in various surgical disciplines. Discussion. The use of intramedullary plugs in cemented total joint arthroplasty is essential in order to achieve good filling and pressurization in hip and knee arthoplasties, traditionally, a small piece of bone or a cement restrictor may be used to plug the shaft. Distal plugs seal the femoral canal, improve fixation and prevent bone cement from leaking during delivery and pressurization. Plugging the intramedullary canal during total hip arthroplasty increases penetration of cement into cancellous bone proximal to the intramedullary plug. Numerous plug designs and materials are available ranging from non-resorbable to resorbable. Regardless of design, all restrictors should avoid intramedullary cement leakage and plug migration during cement and stem insertion to ensure adequate intramedullary pressures. In some instances the diameter of the femoral canal is too wide to accommodate a conventional cement restrictor particularly when crossing the femoral isthmus and even more so in revision procedures requiring the implantation of long stemmed cemented components. The use of the Surgicel-Spongostan haemostatic restrictor overcomes some of the limitations of a standard cement restrictors. These include the ability to bypass a narrow femoral isthmus, accommodate large femoral canals, particularly in revision procedures, and the flexibility of adjusting the restrictor to the desired diameter of the medullary canal and in effect providing a bespoke cement restrictor. This technique was used successfully in over 300 revision hip and knee procedures with no adverse effects and excellent outcomes


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_5 | Pages 3 - 3
1 Mar 2014
Mihok P Bex C Hassaballa M Robinson J Murray J Porteous A
Full Access

Total knee arthoplasty (TKA) remains a standard treatment for advanced knee arthritis. The aim of the procedure is to restore function and relieve pain ideally for the rest of patient's life. Patient matched templating (PMT) or patient specific instrumentation (PSI) is a recent development for alignment of TKA components that uses disposable guides. The users of PSI claim it to be the optimum balance of new technology and conventional technique by reducing the complexity of conventional alignment and sizing tools. To assess the clinical and radiological outcome of Primary TKA done with PSI. More than 200 cases of TKA have been done in our unit using PSI and we analysed the radiographic outcome of these cases postoperatively. We also reviewed the clinical outcome of 103 patients with 1 year and 43 patients with 2 year follow-up. Data was collected prospectively: pre-operatively and at 1 year and 2 years post-operatively including Oxford knee score (OKS), WOMAC and American knee society score (AKS). Standard AP and lateral films were done pre-operatively and post-operatively. Mean age was 66 years. There were 56 female and 47 male patients. Mean post-operative angles on standard films were: Alpha = 95.6, Beta = 88.4, Saggittal femur = 3.4 and Saggittal tibia = 90.8. Of the 103 cases with 1 year follow-up, there was significant improvement in all clinical outcome scores. Mean OKS improved from 18 to 39 at 1 year and remained the same at 2 years, WOMAC improved from 40 to 18 in both 1 and 2 years post-op. AKS Total improved from 79 to 173 at 1 year and 170 at 2 years. Performing TKA using PSI is safe and provides good radiological alignment in the coronal and sagittal plane. Significant improvement in outcome scores were seen at one and two year follow up and reached levels that compared favourably with other reported series of TKA outcome from our unit


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_12 | Pages 41 - 41
1 Mar 2013
Zaghloul A Griffiths E Lawrence C Nicolai P
Full Access

To evaluate prospectively the mid-term results of the Zimmer Unicondylar Knee arthoplasty (UKA). Between 2005 and 2012, 187 unicompartmental knee arthroplasties (UKA) were performed by a single surgeon using a fixed-bearing prosthesis (Zimmer). 37 cases were excluded as either were lost to follow-up or had less than six months follow-up. The study included 150 UKAs. Deformity, if present, was correctable. Patellofemoral joint (PFJ) disease was not considered as an absolute contraindication. The average patient age at the time of surgery was 66 years (range 42–88 years); 78 of which were male. Mean follow-up time was 3.6 years (range 7–81 months). Mean Body Mass Index (BMI) was 29 (range 21–41). Clinical and conventional radiological evaluations were carried out at six months, one, two and five years postoperatively. 147 cases were medial compartment replacement and three were lateral. 86 patients had grade III OA and 64 had grade IV (Kellgren and Lawrence). 113 patients had an element of PFJ disease. The mean Knee Society knee and function scores had an improvement from 55 and 54 points pre-operatively to 95 and 94 points respectively at time of most recent evaluation. The average flexion improved from 116 degrees pre-operatively to 127 degrees. Two cases were revised, one due to progression of osteoarthritis in the lateral compartment of the knee and the other was due to arthrofibrosis. The Zimmer unicompartmental knee arthroplasty provided excellent pain relief and restoration of function in carefully selected patients. However, long-term studies are necessary to investigate the survival rate for this prothesis


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXIX | Pages 5 - 5
1 Jul 2012
McKenna R Winter A Rooney B Leach W
Full Access

Aim. We aim to compare revision rates and functional outcome scores in between two contemporary total knee arthoplasty systems. Methods. A search was carried out of a prospectively maintained outcomes database to identify all patients receiving total knee replacement (TKR) in the department between 2005 and 2006, when evaluation of different knee arthroplasty systems was being undertaken. Data on the first 93 consecutive patients receiving a Scorpio (Stryker, Allendale, NJ) implant and the first 93 consecutively receiving a PFC (DePuy, Warsaw, IN) implant were reviewed. Four year revision rates and functional scores were recorded. Results. Patient demographics were similar in both groups. Six of ninety three Scorpio implants were listed for revision over the four year period (6%). Five of these were for aseptic loosening. Three further patients are currently being investigated for pain and have radiological evidence of loosening with no clinical evidence of infection. No PFC implants required revision in the four year period (p = 0.013). There was no difference in Oxford Scores pre-operatively, or at 3 months, 1 year and 2 years post-operatively. Discussion. There is a significant difference in revision rates between the two prostheses, and the revision rate of the Scorpio prosthesis is far higher than would be expected. The majority of these have been revised for aseptic loosening. Those prostheses surviving to four years had similar clinical outcomes. The reasons for this higher than expected revision rate in the Scorpio group require further exploration