Aim of the study: to assess the early complication rate following
The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants. We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by comminution and loss of bone stock. All patients were treated with the help of cantilever mechanism using multiple Kirschner wires augmented by compression plates. All the patients were operated by the same surgeon between November 2020 to March 2021 and followed up till March 2023. Surgical outcomes were evaluated according to the clinical and radiological criteria. A total of 10 patients were included in the study. Since we only included patients with highly unstable and comminuted fractures which were difficult to fix with traditional methods, the number of patients in the study were less. All 10 patients showed satisfactory clinical and radiological union at the end of the study with good range of motion. One of the patient in the study had post-operative wound complication which was managed conservatively with regular dressings and oral antibiotics. Comminuted metaphyseal fractures might differ in pattern and presentation with every patient and there can be no standard treatment for all. The cantilever technique of fracture fixation is based on the principle of cantilever mechanism used in bridges and helps achieve good anatomical reduction and fixation. It provides a decent alternative when standard modes of fixation don't give desired result owing to comminuted nature of fractures and deficiency of bone stock.
Aim. To investigate the effectiveness of a decision-based protocol designed to minimise the use of medial incisions when performing crossed-wire fixation of supracondylar fractures of the distal humerus whilst minimising ulnar nerve injury. Method. We have employed a protocol for placing the medial wire during crossed k-wire fixation of supracondylar fractures dependent upon the medial epicondyle. When this is palpable, the wire is introduced percutaneously; when it is not, a mini-incision is made. All cases of closed reduction and crossed
Aim of the study: to assess the early complication rate following
Distal interphalangeal joint (DIPJ) fusion using a k-wire has been the gold standard treatment for DIPJ arthritis. Recent studies have shown similar patient outcomes with the headless compression screws (HCS), however there has been no cost analysis to compare the two. Therefore, this study aims to 1) review the cost of DIPJ fusion between k-wire and HCS 2) compare functional outcome and patient satisfaction between the two groups. A retrospective review was performed over a nine-year period from 2012-2021 in Counties Manukau. Cost analysis was performed between patients who underwent DIPJ fusion with either HCS or k-wire. Costs included were surgical cost, repeat operations and follow-up clinic costs. The difference in pre-operative and post-operative functional and pain scores were also compared using the patient rate wrist/hand evaluation (PRWHE). Of the 85 eligible patients, 49 underwent fusion with k-wires and 36 had HCS. The overall cost was significantly lower in the HCS group which was 6554 New Zealand Dollars (NZD), whereas this was 10408 NZD in the k-wire group (p<0.0001). The adjusted relative risk of 1.3 indicate that the cost of k-wires is 1.3 times more than HCS (P=0.0053). The patients’ post-operative PRWHE pain (−22 vs −18, p<0.0001) and functional scores (−38 vs −36, p<0.0001) improved significantly in HCS group compared to the k-wire group. Literatures have shown similar DIPJ fusion outcomes between k-wire and HCS. K-wires often need to be removed post-operatively due to the metalware irritation. This leads to more surgical procedures and clinic follow-ups, which overall increases the cost of DIPJ fusion with k-wires. DIPJ fusion with HCS is a more cost-effective with a lower surgical and follow-up costs compared to the
Background: Distal forearm fractures are common in children. Many studies have described high failure rate when treated by closed reduction and immobilization in plaster cast. Loss of reduced position in the cast has been shown to be the most important factor leading to malunion and failure of the treatment. Treating these fractures by closed reduction and percutaneous Kirsch-ner (K-) wiring has been recommended. Objective: This study aims at determining the value of management of distal forearm fractures in children by closed reduction and percutaneous
Purpose. To elucidate whether there is an advantage in external fixation supplementation of K-wires in comparison to K-wires and plaster, in the treatment of distal radius fractures without metaphyseal comminution. Indications. Distal intraarticular radius fractures, Frykman VIII or VIII without metaphyseal comminution. Contraindications. Metaphyseal comminution, general medical contraindications for surgical intervention. Study design. Fifty-one patients were prospectively randomised in two groups: 24 patients were treated with K-wire and spanning external fixation supplementation, and 27 were treated with K-wires and plaster. Results. Patients were monitored following the operation with a minimum follow up of 1 year, and checked independently of surgeon for pain, satisfaction and range of motion. There was a statistically significant difference in favour of the external fixation patient group for pain (Visual Analogue Score, Ex-Fix group: mean 14.9, plaster group: mean 28.1, p<0.001) and satisfaction (Ex-Fix group: mean 89.7, plaster group: mean 76.3, p<0.001,). Although one would expect that range of motion would be reduced in the external fixation group, there were no statistically significant differences found in favour of plaster; on the contrary supination results were surprisingly in favour of the external fixation group (Ex-Fix group: mean 54.4, plaster group: mean 45.2, p<0.05). Conclusion. In this study, external fixation supplementation of
53 patients underwent closed reduction and longitudinal
Introduction. A recent retrospective study of distal femoral physeal fractures (DFPFs) suggested closed manipulation alone has a high incidence of re-displacement, malunion or physeal bar formation. The paper concluded that all displaced DFPFs require internal fixation, and breaching the physis with k-wires is safe. We agree that hyper-extension/flexion injuries need stabilisation using k-wires but, in our experience, purely valgus/varus deformities can be successfully managed by manipulation under anaesthesia (MUA) and a moulded cylinder cast. Method. We prospectively observed DFPFs presenting over 12 months. Departmental policy is to treat varus/valgus deformities by MUA, with cylinder casting providing 3 point fixation. Hyper-extension/flexion injuries are reduced on a traction table. 2mm cross
Reduction and
Introduction: Displaced Colles’ fractures are usually managed by closed reduction and cast immobilisation. They are reduced initially but frequently lose position because cast immobilisation is an inefficient means of stabilisation. This results in malunion. If position is lost after reduction and cast immobilisation or the fracture is unstable, closed reduction and cast immobilisation is often supplemented by longitudinal k-wire fixation. There is a paucity of literature examining the incidence of unacceptable malunion after closed reduction and k-wire stabilisation. Aim: The aim of this study was to determine whether closed reduction, longitudinal k-wire fixation and cast immobilisation of displaced fractures of the distal radius avoids unacceptable malunion. A secondary aim was to define the type of fracture best treated by this method. Methods: 53 patients underwent closed reduction and longitudinal
Introduction: The increasing popularity of minimal access surgery in orthopaedic surgery has resulted in increasing use of intra-operative fluoroscopy. The radiation dose received by the surgeon varies from procedure to procedure depending on several factors such as duration of procedure, direct exposure to radiation beam and distance from the radiation source. In particular hand and wrist injuries often involve direct fluoroscopic exposure to the hands of the surgeon and assistant during the procedure. Aim: We undertook a prospective study to directly evaluate the exposure of the surgeon’s and assistant’s hands and thyroid glands during
Aim. Differing reports about the surgical management of the supracondylar humeral fracture make evidence-based practice very difficult, so knowledge of the contemporary practices and opinions of an expert body can provide a useful benchmark for appraisal; the aim of this study was to obtain this information. Methods. An electronic 18 item, single response multiple-choice questionnaire was designed to investigate various aspects of the surgical management of supracondylar fractures, with particular focus on areas that remain controversial in the literature. Members of BSCOS were invited by email, on three occasions, to complete the questionnaire, which was posted on the web-based SurveyMonkey™ platform (. www.surveymonkey.com. , California, USA). The survey was available for completion for a period of 10 weeks. Results. 102 responses were received (response rate 56.7%); all respondents completed the entire questionnaire. There was almost complete agreement (>90%) in only three areas: -The preferred management of Gartland 3 fractures; The management of the fracture with an absent radial pulse and impaired digital perfusion; An ulnar nerve palsy detected four weeks post-operatively. Majority agreement (>60%) was found regarding: - Possible consequences of delay in performing closed reduction; Management of the pink, perfused hand with an absent radial pulse; Necessity of anatomical reduction. There was no consensus regarding: -
Out of a total of 112 children with displaced forearm shaft fracture treated with Percutaneous Kirschner (K) wire fixation in the past 9 years, 84 cases with fracture of both the radius and ulna were reviewed. 64 (76%) had fixation of both the radius and ulna, 10 (12%) the radius only and the other 10 (12%) the ulna only. In 60 (71%) patients were successful with one stage close reduction and pinning, while in the remaining 24 (29%) a semi- open reduction through a small incision was required. The K-wire was inserted through the radial styloid or the Lister tubercle for the radius, and through the tip of the olecranon for the ulna. All the patients reviewed were found to have good functional results with no non-union, deep infection or premature physeal closure at a mean follow-up of 48 months. Initial pre-operative shortening or translation of the fracture were associated with significantly higher chance of open reduction. We concluded that percutaneous
Background. Proximal phalangeal fractures are caused by an injury to the dorsum of the hand. This usually causes volar angulation which is unstable when reduced.
Aims: To compare the cost of intra-medullary implants used stabilising paediatric diaphyseal fractures with the clinical outcome. Methods: Between March 1994 and August 2001, at two centres, The Womenñs and Childrenñs Hospital, Adelaide, Australia and The Royal London Hospital, London UK 60 children were surgically treated for diaphyseal forearm fractures using Elastic Stable Intramedullary Nails (ESIN) or 2.5mm Kirschner wires. Having established no difference in the clinical outcome or subjective disability of either technique we compared the implant cost directly. Results: The two treatments both resulted in an excellent outcome with all fractures leading to union with no subjective disability. The Kirscner wires cost £3.00 per wire while the ESI Nails cost between £57.50 and £ 113.30 per wire, depending on the dimensions. Conclusions: We were not able to demonstrate any difference in outcome between ESIN and
Introduction: Arthrodesis of 1st MTPJ is performed using various fixation techniques including lag screws, dorsal plate and screws,
Introduction: Distal radius metaphyseal fractures in children are not uncommon, but when they occur proximal to the insertion of the pronator quadratus muscle, reduction and maintenance of reduction can be challenging. The deforming forces at the fracture site result in pronation and shortening of the distal fragment. Manual manipulation of this fracture often results in tearing of the dorsal periosteum and hence renders this fracture highly unstable. Aim: We present a novel easily reproducible mini-open surgical technique and functionally and radiologically evaluate a series of eleven patients who have undergone this technique. Materials and Methods: The surgical technique consists of a mini-open intrafocal image intensifier guided reduction technique with percutaneous
Aims: There are no large published studies examining the complication rates associated with use of Kirschner wires in þxation of a wide variety of paediatric fractures. The aim of this study is to analyse the outcomes of fracture þxation using K-wire in upper limb fractures in children and to critically assess the incidence and type of complications. Methods: This study is a retrospective review of a consecutive series of 107 fractures in 105 paediatric trauma cases treated with K-wire in between 01.09.99 to 10.09.01. Results: The fractures were fractures around Wrist (47%) and around elbow (45%). 66 (61.68%) were performed by closed percutaneous technique, 27 (25.23%) by open method and in 14 (13.08%) combined approach was used. Around there were 13 cases with over-granulation at wound site, 6 cases of Soft tissue infection, 2 cases with tendinitis, 1 case of Osteo-myelitis and 1 case with hyper-sensitive scar. 3 cases found to have postoperative neurapraxia and 1 case with axonotmesis. Metal migration was detected in 4 cases and 14 cases found to have shown wire loosening. 10 fractures have lost position in postoperative period out of which 2 cases were reoperated for Re K-wire, 1 had undergone Re-MUA and 7 left for remodelling. Conclusions: K-wires are versatile but are not inherently benign. We conclude that best results could be achieved if total life of K-wire can be restricted to 3–4 weeks. We recommend one should explain all these risks and complications during consenting for
Introduction: There is paucity of literature describing complex lateral condylar mass (LCM) fractures of the elbow in children, which we define as a LCM fracture occurring concurrently with another fracture or dislocation in the same elbow. The aim of this study was to evaluate the management, outcome and complication rate of 26 complex LCM fractures and to analyse difference in the outcome between the isolated and complex LCM fractures. Materials and methods: Between 1990 and 2005, we identified 26 complex LCM fractures in the departmental database (1% of 2502 elbow/humeral injuries). Information was collected from theatre-charts, casenotes and radiographs. The mean follow-up was 5.9 months (range, 6 weeks to 4 years). Results: These were complex because of their association with elbow dislocation (n=12; mean age 8.2 years), olecranon fracture (n=8; mean age 4.1 years) and medial condylar fracture (n=6; mean age 8 years). Nine were treated conservatively. The remaining 17 were fixed with K-wires (9), a screw (7) or both (1). A concomitant elbow dislocation was managed by closed reduction followed by open