Introduction. Vitamin-E has been introduced into
The material properties of gamma irradiated Ultra High Molecular Weight (UHMW) polyethylene are known to degrade during exposure to air. Though gamma inert-sterilization has been developed to decrease free radicals, the rate of degeneration of UHMW polyethylene in vivo has not well known. This study aimed to compare the properties of gamma inert-irradiated highly-cross-linked UHMW polyethylene samples after exposure to air and the properties of gamma inert-irradiated
The benefits of HXLPE in total knee arthroplasty (TKA) have not been as evident as total hip arthroplasty (THA). A systematic review and meta-analysis to assess the impact of
The purpose of this investigation is to assess the rate of wear the effect once the “bedding in period”/ poly creep had been eliminated. Creep is the visco-elastic deformation that polyethylene exhibits in the first 6–12 weeks. We also assessed the wear pattern of four different bearing couples in total hip arthroplasty (THA): cobalt-chrome (CoCr) versus oxidized zirconium (OxZir) femoral heads with ultra-high molecular weight polyethylene (UHMWPE) versus
Total hip arthroplasty (THA) is one of the most successful and commonly performed surgical interventions worldwide. Based on registry data, at one-year post THA, implant survivorship is nearly 100% and patient satisfaction is 90%. A novel, porous coated acetabular implant was introduced in Europe and Australia in 2007. Several years after its introduction, warnings were issued for the system when used with metal-on-metal bearings due to adverse local tissue reaction, with one study reporting a 24% failure rate (Dramis et al. 2014). A subsequent 2018 study by Teoh et al. showed that the acetabular system had a survival rate of 98.9% at five years when used with conventional polyethylene or ceramic bearing surfaces. The current study was conducted to determine the safety and effectiveness of the acetabular system using standard
Recent issues related to trunionosis have created a new paradigm in choosing femoral head material in total hip arthroplasty. While many consider
Introduction. Over 40-years the dominant form of implant fixation has been bone cement (PMMA). However the presence of circulating PMMA debris represents a 3rd-body wear mechanism for metal-on-polyethylene (MPE). Wear studies using PMMA slurries represent tests of clinical relevance (Table 1). Cup designs now use many varieties of
Introduction:. Although commonly used, the clinical performance of highly crosslinked polyethylene in total knee arthroplasty (TKA) remains unknown and concerns exist regarding fatigue resistance and oxidation, particularly in posterior-stabilized (PS) designs. The purpose of this study is to compare highly crosslinked and conventional polyethylene in a PS TKA design at a minimum of 5-years. Methods:. A prospective cohort study of 114 consecutive TKAs in 83 patients was performed as a subset of a multi-center prospective study. All TKAs utilized an identical PS design. Conventional polyethylene inserts were used in 50 knees and second-generation highly cross-linked polythethylene inserts were implanted in 64 TKAs. All patients were followed with clinical outcome measures (Short-Form 36, Knee Society Scores, WOMAC and LEAS) and radiographically for a minimum of 5 years. Results:. The mean age of the highly cross-linked polyethylene group was 4 years less than the conventional group (p = 0.03). There was no difference in BMI (p = 0.3) or preoperative outcome measures between groups with numbers available. Seven patients died or were lost to follow up and one underwent revision for infection at 3 months postoperatively. 103 TKAs obtained minimum 5-year follow up. Mean Knee Society Scores were 12 points higher (p = 0.01) and 14 points higher (p = 0.005) in the physical function subset of the SF-36 in the highly cross-liked polyethylene group. There was no difference in the other outcome measures with the numbers available. There was no radiographic osteolysis or mechanical failures related to the tibial polyethylene in either group. Conclusion:. Mechanical failure or radiographic osteolysis was not observed with either conventional or highly cross-linked polyethylene in this PS TKA design at mid-term follow up. To our knowledge, this is the first minimum 5-year follow-up of highly cross-linked polyethylene in a posterior-stabilized design. While the results support comparative safety, longer-term follow-up is warranted to determine if wear resistance and mechanical properties of highly crosslinked polyethylene are maintained. Significance: Concerns regarding early fatigue failure and mechanical complications related to the PS post-cam articulation of
Introduction. Modular femoral necks have shown promising clinical results in total hip arthroplasty (THA) to optimize offset, rotation, and leg length. Given the wide variety of proximal femoral morphology, fine-tuning these kinematic parameters can help decrease femoroacetabular impingement, decrease wear rates and help prevent dislocations. Yet, additional implant junctions introduce additional mechanisms of failure. We present two patients who developed an abnormal soft tissue reaction consistent with a metal hypersensitivity reaction at a modular femoral neck/stem junction requiring revision arthroplasty. Methods. Two patients underwent THA for primary osteoarthritis with the same series of components: 50 mm shell, a 36 mm
Wear in polyethylene liners appears to be exacerbated by 3rd-body abrasion effects with the CoCr ball combinations used for total hip replacements. This has implications for various wear modes encountered in patients. Yet clinical and laboratory studies have offered weak and sometimes contradictory wear relationships with respect to crosslinking, ball diameter and roughness, and 3rd-body wear effects. Our hip simulator model investigated the effect of severe wear challenges by 3rd-body cement particles, using large diameter CoCr and alumina balls, with
The Mathys Affinis Short is the most frequently used stemless total shoulder prosthesis in the UK. The purpose of this prospective cohort study is to report the survivorship, clinical, and radiological outcomes of the first independent series of the Affinis Short prosthesis. From January 2011 to January 2019, a total of 141 Affinis Short prostheses were implanted in 127 patients by a single surgeon. Mean age at time of surgery was 68 (44 to 89). Minimum one year and maximum eight year follow-up (mean 3.7 years) was analyzed using the Oxford Shoulder Score (OSS) at latest follow-up. Kaplan-Meier survivorship analysis was performed with implant revision as the endpoint. Most recently performed radiographs were reviewed for component radiolucent lines (RLLs) and proximal humeral migration.Aims
Methods
The primary aim of the study was to compare the knee-specific functional outcome of robotic unicompartmental knee arthroplasty (rUKA) with manual total knee arthroplasty (mTKA) for the management of isolated medial compartment osteoarthritis. Secondary aims were to compare length of hospital stay, general health improvement, and satisfaction between rUKA and mTKA. A powered (1:3 ratio) cohort study was performed. A total of 30 patients undergoing rUKA were propensity score matched to 90 patients undergoing mTKA for isolated medial compartment arthritis. Patients were matched for age, sex, body mass index (BMI), and preoperative function. The Oxford Knee Score (OKS) and EuroQol five-dimension questionnaire (EQ-5D) were collected preoperatively and six months postoperatively. The Forgotten Joint Score (FJS) and patient satisfaction were collected six months postoperatively. Length of hospital stay was also recorded.Aims
Methods