Oxidized zirconium (Oxinium) and
Purpose:. Although short term outcomes of reverse total shoulder arthroplasty (rTSA) have been promising, long-term success may be limited due to complications, including scapular notching. Scapular notching has been explained primarily as a mechanical erosion, however, generation of wear debris may lead to further biologic changes contributing to the severity of scapular notching.
Aims: Hipsimulator tests with
Introduction.
Summary. Four
Introduction. Technological advances in the processing of polyethylene have led to improved survivorship of total hip arthroplasty. The purpose of this study was to determine if a second generation
Aims. Limited implant survival due to aseptic cup loosening is most commonly responsible for revision total hip arthroplasty (THA). Advances in implant designs and materials have been crucial in addressing those challenges. Vitamin E-infused
Aims. Radiostereometric analysis (RSA) is the most accurate radiological method to measure in vivo wear of
Summary Statement. In the most recent type of
Introduction and Aims: Modular acetabular designs are widely used in THA procedures and now accommodate
Introduction: Wear simulator studies have predicted that
Introduction and Aims: While
Introduction A biomechanical model was developed to measure wear of all-polyethylene patellar components as it relates to femoral component mal-rotation. The model, based on high load and flexion activities such as stair climbing, was used to differentiate the effects of femoral mal-rotation and differing materials on a single patellar design. Methods The patellar components (Scorpio®, Stryker-Howmedica-Osteonics) were cemented onto metal fixtures and articulated against “aligned” and “mal-aligned” (six degrees internally rotated) femoral components. The patellar components were subjected to a constant force and articulated against femoral components flexing from 600 to 1200. Patellae of identical geometry, made of conventional and
Introduction: Electron beam irradiated highly cros-slinked polyethylene has been used in total hip arthroplasty for over 8 years. Due to its low wear characteristics, the use of femoral heads that are greater than 32mm in diameter is now available, allowing for an increase in range of motion and increased stability against dislocation when necessary. The purpose of this study is to provide a summary report on the radiographic analysis of the longest term data available on primary THR patients receiving
Background. Cross-linked polyethylene has much less wear than conventional polyethylene and can used in a more bone conserving thickness of 4 mm. We have used it for hip resurfacing since 2001. Questions/Purposes. This study evaluated the effectiveness of a
Introduction:. The management strategy regarding optimally addressing polyethylene wear with a well-fixed acetabular shell remains controversial. The purpose of the present study was to document outcomes of cementation of a
Background. The advent of
The advent of