Abstract. Purpose. Intracanal rib
Aims. This study investigates head-neck taper corrosion with varying
Previous reports on the outcomes of isolated
Aims. The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm
There remains much debate regarding the optimal method for surgical management of patients with long
Introduction. Assessment of the humeral
Dislocation after total hip arthroplasty in individuals treated for acute hip fracture is up to 10 times more frequent than in elective patients. Whilst approach plays a role, the effect of
Ceramic-on-ceramic (CoC) articulations in total hip arthroplasty (THA) have low wear, but the unique risk of fracture. After revision for CoC fracture, ceramic third bodies can lead to runaway wear of cobalt chrome (CoCr) causing extremely elevated blood cobalt. We present five cases of ceramic liner fractures revised to a CoCr
Introduction. The rise of the anterior approach (AA) in primary surgery has led to enthusiasm for using this approach in revision surgery, especially because
Some activities of daily living require that the
Introduction and Objective. There remains much debate regarding the optimal method for surgical management of patients with long
Purpose. Primary total hip arthroplasty (THA) has been a very successful surgical intervention for the management of end-stage arthritis in geriatric patients (> age 65). The mid- to long-term results have been less satisfactory however, in younger patients primarily due to the wear of the acetabular liner and loosening of the femoral component. The primary study purpose was to compare pain, function and stiffness over the first five years in a population less than 60 years of age who received either an alumina liner/alumina femoral head (alumina group) or a crossfire UHMWPE liner/alumina
Aims. The most frequent indication for revision surgery in total hip arthroplasty (THA) is aseptic loosening. Aseptic loosening is associated with polyethylene liner wear, and wear may be reduced by using vitamin E-doped liners. The primary objective of this study was to compare proximal femoral head penetration into the liner between a) two cross-linked polyethylene (XLPE) liners (vitamin E-doped (vE-PE)) versus standard XLPE liners, and b) two modular femoral head diameters (32 mm and 36 mm). Methods. Patients scheduled for a THA were randomized to receive a vE-PE or XLPE liner with a 32 mm or 36 mm metal
Introduction. Total shoulder arthroplasty (TSA) is an effective treatment to restore shoulder function and alleviate pain in the case of glenohumeral arthritis [1]. Stress shielding, which occurs when bone stress is reduced due to the replacement of bone with a stiffer metallic implant, causes bone resorption of up to 9% of the humeral cortical thickness following TSA [2]. Shorter length stems and smaller overall geometries may reduce stress shielding [3], however the effect of humeral
Reverse shoulder arthroplasty (RSA) has an increasing effective use in the treatment of patients with a variety of diagnoses, including rotator cuff deficiency, inflammatory arthritis, or failed shoulder prostheses. Glenoid bone loss is not uncommonly encountered in these cases due to the significant wear. Severe bone loss can compromise glenoid baseplate positioning and fixation, consequently increasing the risk for early component loosening, instability, and scapular notching. To manage severe glenoid bone deficiencies, bone grafts are commonly used. Although, many studies report outcome of bone grafting in revision RSA, the literature on humeral
Fibular
Introduction. Total hip arthroplasty (THA) is a commonly performed procedure to relieve arthritis or traumatic injury. However, implant failure can occur from implant loosening or crevice corrosion as a result of inadequate seating of the femoral head onto the stem during implantation. There is no consensus—either by manufacturers or by the surgical community—on what
Objectives. The long
Recently in traumatology various methods of impregnation biodegradable implants and allografts with antibiotics are widely used. Among them the soaking, shaking and ionophores are common used. We aimed to choose the optimal method of impregnation with the antibiotic of the
Taper corrosion in Total Hip Arthroplasty has surfaced as a clinically relevant problem and has recently also been reported for metal