Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_11 | Pages 34 - 34
1 Nov 2022
Haleem S Malik M Azzopardi C Botchu R Marks D
Full Access

Abstract. Purpose. Intracanal rib head penetration is a well-known entity in dystrophic scoliotic curves in neurofibromatosis type 1. There is potential for spinal cord injury if this is not recognised and managed appropriately. No current CT-based classification system is currently in use to quantify rib head penetration. This study aims to propose and evaluate a novel CT-based classification for rib head penetration primarily for neurofibromatosis but which can also be utilised in other conditions of rib head penetration. Materials and methods. The grading was developed as four grades: normal rib head (RH) position—Grade 0, subluxed ext-racanal RH position—Grade 1, RH at pedicle—Grade 2, intracanal RH—Grade 3. Grade 3 was further classified depending on the head position in the canal divided into thirds. Rib head penetration into proximal third (from ipsilateral side)—Grade 3A, into the middle third—Grade 3B and into the distal third—Grade 3C. Seventy-five axial CT images of Neurofibromatosis Type 1 patients in the paediatric age group were reviewed by a radiologist and a spinal surgeon independently to assess interobserver and intraobserver agreement of the novel CT classification. Agreement analysis was performed using the weighted Kappa statistic. Results. There was substantial interobserver correlation with mean Kappa score (k = 0.8, 95% CI 0.7–0.9) and near perfect intraobserver Kappa of 1.0 (95% CI 0.9–1.0) and 0.9 (95% CI 0.9–1.0) for the two readers. Conclusion. The novel CT-based classification quantifies rib head penetration which aids in management planning


Bone & Joint Open
Vol. 2, Issue 11 | Pages 1004 - 1016
26 Nov 2021
Wight CM Whyne CM Bogoch ER Zdero R Chapman RM van Citters DW Walsh WR Schemitsch E

Aims. This study investigates head-neck taper corrosion with varying head size in a novel hip simulator instrumented to measure corrosion related electrical activity under torsional loads. Methods. In all, six 28 mm and six 36 mm titanium stem-cobalt chrome head pairs with polyethylene sockets were tested in a novel instrumented hip simulator. Samples were tested using simulated gait data with incremental increasing loads to determine corrosion onset load and electrochemical activity. Half of each head size group were then cycled with simulated gait and the other half with gait compression only. Damage was measured by area and maximum linear wear depth. Results. Overall, 36 mm heads had lower corrosion onset load (p = 0.009) and change in open circuit potential (OCP) during simulated gait with (p = 0.006) and without joint movement (p = 0.004). Discontinuing gait’s joint movement decreased corrosion currents (p = 0.042); however, wear testing showed no significant effect of joint movement on taper damage. In addition, 36 mm heads had greater corrosion area (p = 0.050), but no significant difference was found for maximum linear wear depth (p = 0.155). Conclusion. Larger heads are more susceptible to taper corrosion; however, not due to frictional torque as hypothesized. An alternative hypothesis of taper flexural rigidity differential is proposed. Further studies are necessary to investigate the clinical significance and underlying mechanism of this finding. Cite this article: Bone Jt Open 2021;2(11):1004–1016


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 79 - 79
23 Jun 2023
Paprosky W Gerlinger T
Full Access

Previous reports on the outcomes of isolated head and liner exchange in revision total hip arthroplasty have found high rates of instability following these surgeries. Most reports have studied constructs using ≤28mm femoral heads. The purpose of this study was to determine if modern techniques with the use of larger head sizes can improve the rate of instability after head and liner exchange. We identified 138 hips in 132 patients who underwent isolated head and liner exchange for polyethylene wear/osteolysis (57%), acute infection (27%), metallosis (13%), or other (2%). All patients underwent revision with either 32mm (23%), 36mm (62%), or 40mm (15%) diameter heads. Crosslinked polyethylene was used in all revisions. Lipped and/or offset liners were used in 104 (75%) hips. Average follow up was 3.5 (1.0–9.1) years. Statistical analyses were performed with significance set at p<0.05. Revision-free survivorship for any cause was 94.6% and for aseptic causes was 98.2% at 5 years. 11 (8%) hips experienced a complication with 7 (5%) hips requiring additional revision surgery. Following revision, 4 (3%) hips experienced dislocation, 5 (4%) hips experienced infection, and 1 (1%) hip was revised for trunnionosis. No demographic or surgical factors significantly affected outcomes. Our study shows that isolated head and liner exchange using large femoral heads and modern liners provides for better stability than previous reports. The most common complication was infection. We did not identify specific patient, surgical or implant factors that reduced the risk of instability or other complication


The Bone & Joint Journal
Vol. 105-B, Issue 10 | Pages 1052 - 1059
1 Oct 2023
El-Sahoury JAN Kjærgaard K Ovesen O Hofbauer C Overgaard S Ding M

Aims. The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA). Methods. A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size. Results. A total of 116 patients participated, of whom 77 were male. The median ages of the vE-PE 32 mm and 36 mm groups were 65 (interquartile range (IQR) 57 to 67) and 63 years (IQR 56 to 66), respectively, and of the XLPE 32 mm and 36 mm groups were 64 (IQR 58 to 66) and 61 years (IQR 54 to 66), respectively. Mean total head penetration was significantly lower into vE-PE acetabular liner groups than into XLPE acetabular liner groups (-0.219 mm (95% confidence interval -0.348 to -0.090); p = 0.001). There were no differences in wear according to head size, acetabular component migration, or PROMs, except for UCLA. There were no cases of aseptic loosening or failures requiring revision at long-term follow-up. Conclusion. Significantly lower wear was observed in vE-PE acetabular liners than in XLPE acetabular liners. No difference in wear was observed between different head size or PROMs except for the UCLA at ten years. Cite this article: Bone Joint J 2023;105-B(10):1052–1059


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 64 - 64
4 Apr 2023
Hartland A Islam R Teoh K Rashid M
Full Access

There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included pain (visual analogue scale VAS), rate of Popeye deformity, and operative time. 860 patients from 11 RCTs (426 tenotomy vs 434 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.14, 95% CI −0.04 to 0.32; p=0.13). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. There was no significant difference for pain (VAS). Tenodesis resulted in a lower rate of Popeye deformity (OR 0.29, 95% CI 0.19 to 0.45, p < 0.00001). Tenotomy demonstrated a shorter operative time (MD 15.21, 95% CI 1.06 to 29.36, p < 0.00001). Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. A large multi-centre clinical effectiveness randomised controlled trial is needed to provide clarity in this area


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 31 - 31
1 Nov 2021
Rogmark C Nåtman J Hailer N Jobory A Cnudde P
Full Access

Dislocation after total hip arthroplasty in individuals treated for acute hip fracture is up to 10 times more frequent than in elective patients. Whilst approach plays a role, the effect of head sizes in conventional THA and dual mobility cups (DMC) is less studied in fracture cases. The total dislocation rate at 1-year and 3-year revision rates were recorded in this observational study on 8,031 patients with acute hip fracture, treated with a THA 2005–2014. Swedish Arthroplasty Register data were linked with the National Patient Register. Cox multivariable regression models were fitted to calculate adjusted hazard ratios stratified by approach and head size. The cumulative risk of dislocation during year 1 was 2.7% (95% CI 2.2–3.2) with lateral approach and 8.3% (7.3–9.3) with posterior approach (KM estimates). In the posterior approach group DMC was associated with a lower risk of dislocation compared to cTHA=32mm (HR=0.21; 0.07–0.68), whilst a head size <32mm carried a higher risk (HR=1.47; 1.10–1.98). These differences were no longer visible when revision in general was used as outcome. Neither of the implant designs influenced the dislocation risk when direct lateral approach was used. Male gender and severe comorbidity increased the risk. DMC with lateral approach was associated with a reduced risk of revision in general (HR=0.36; 0.13–0.99). Head size did not influence the revision risk. When aiming to reduce the risk of any dislocation, lateral approach – regardless of cup/head design – is referable. If, for any reason, posterior approach is used, DMC is associated with the lowest risk of dislocation. This is not reflected in analysing revision in general as outcome. An interpretation could be that there are different thresholds for dislocation prompting revision


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 66 - 66
19 Aug 2024
Terhune EB Sutter EG Balkissoon R Pallante GD Specht L Leikin JB Kwon YM Lewallen DG Gerlinger TL Jacobs JJ
Full Access

Ceramic-on-ceramic (CoC) articulations in total hip arthroplasty (THA) have low wear, but the unique risk of fracture. After revision for CoC fracture, ceramic third bodies can lead to runaway wear of cobalt chrome (CoCr) causing extremely elevated blood cobalt. We present five cases of ceramic liner fractures revised to a CoCr head associated with the rapid development of severe cobalt toxicity. We identified 5 cases of fractured CoC THA treated with revision to CoCr on highly cross-linked polyethylene (HXLPE) – three to conventional bearings and two to modular dual mobility bearings (CoCr acetabular liner, CoCr femoral head, and HXLPE). Mean follow up was 2.5 years after CoCr/HXLPE re-revision. Symptoms of cobalt toxicity occurred at average 9.5 months after revision for ceramic fracture (range 6–12). All patients developed vision and hearing loss, balance difficulties, and peripheral neuropathy. Several had cardiomyopathy, endocrinopathy, and local skin discoloration. Two reported hip pain. Re-revision for cobalt toxicity occurred at an average of 22 months (range 10–36) after revision for ceramic fracture. Average serum cobalt level at re-revision was 991 μg/L (range 734–1302, normal <1 μg/L). All CoCr heads exhibited massive wear with asphericity; deep tissues exhibited prominent metallosis. Treatment consisted of debridement and revision to a ceramic head with HXLPE. Serum cobalt improved to an average of 25 μg/L at final follow up. All patients reported partial improvement in vision and hearing; peripheral neuropathy and balance did not recover. Systemic cobalt toxicity is a rare but devastating complication of ceramic fracture in THA treated with cobalt-alloy bearings. Cobalt alloy bearings should be avoided in this setting. The diagnosis of systemic cobalt toxicity requires a high index of suspicion and was typically delayed following systemic symptoms. Debridement and revision to a ceramic-on-HXLPE leads to improvement but not resolution of cobalt toxicity complications


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_10 | Pages 26 - 26
1 Oct 2020
Hamilton WG Robertson RN Cororaton AD Ho H Hopper RH
Full Access

Introduction. The rise of the anterior approach (AA) in primary surgery has led to enthusiasm for using this approach in revision surgery, especially because head and liner exchanges have been accompanied by a high dislocation rate when the posterior approach (PA) is used. The aim of this study was to compare the institutional dislocation rate comparing the PA and AA in isolated head and liner exchange. Methods. A retrospective institutional database query was done to identify all aseptic head and liner exchanges between the years 2010- June, 2020. 186 hips were identified with an average age of 64.8+/−10.8 yrs (27.9–87.6) and average BMI of 28.7+/−6.3 kg/m2 (16.2–52). The reason for revision was polyethylene wear and osteolysis in 105 hips (56.5%), adverse tissue reaction to metal on metal (MOM) in 43 hips (23.1%), and recurrent instability in 38 hips (20.4%). The approach used for the revision surgery was PA in 128 hips (68.8%) and AA in 58 hips (31.2%). The mean follow-up for this cohort is 1.9±2 yrs (0.0–8.6). Results. The overall dislocation rate for the entire cohort was 28/186 (15%). There was no difference in the dislocation rate whether the revision surgery was performed by the PA 19/128 (15%) or the AA 9/58 (16%) (p=0.9). With the numbers available, there was no difference in dislocation rates when comparing reason for revision: poly wear/osteolysis 12/105 (11%), MOM 8/43 (19%) or recurrent instability 8/38 (21%) (p=0.28). The head size used in the exchange did not influence the dislocation rate; 28 mm-2/11 (18%), 32 mm-6/56 (11%), 36 mm-16/91 (18%), 40 mm-4/26 (15%) (p=0.89). Conclusion. The use of either the PA or AA did not alter the dislocation rate in our cohort. While there was a trend towards a higher dislocation rate when liner exchange was performed for MOM or recurrent instability, no statistical difference was shown with the numbers available. The head size used in the revision did not influence the rate of dislocation


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 87 - 87
1 Nov 2021
Muriuki MG
Full Access

Some activities of daily living require that the head be kept level during axial rotation of the cervical spine (Kinematically Constrained Axial Rotation). One such activity is looking over one's shoulder when walking or driving. The kinematic constraint of keeping the head level during axial rotation means that the segmental axis of rotation may not be aligned with the global axis of rotation of the cervical spine. Most of the literature on cervical spine axial rotation is based on experiments where the segmental axis of rotation is aligned with the global axis of rotation (Traditional Axial Rotation). There are only a few clinical and biomechanical studies that have examined kinematically constrained cervical axial rotation. We performed a series of biomechanical experiments in which we tested cervical spines in traditional and kinematically constrained axial rotation. The resulting primary and coupled motions of the segments showed that kinematically constrained axial rotation is distinct from traditional axial rotation. Our findings and the findings of other kinematically constrained axial rotation studies will be compared and contrasted with data from traditional axial rotation studies


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_13 | Pages 35 - 35
1 Nov 2021
Hartland A Islam R Teoh K Rashid M
Full Access

Introduction and Objective. There remains much debate regarding the optimal method for surgical management of patients with long head of biceps pathology. The aim of this study was to compare the outcomes of tenotomy versus tenodesis. Materials and Methods. This systematic review and meta-analysis was registered on PROSPERO (ref: CRD42020198658). Electronic databases searched included EMBASE, Medline, PsycINFO, and Cochrane Library. Randomized controlled trials (RCTs) comparing tenotomy versus tenodesis were included. Risk of bias within studies was assessed using the Cochrane risk of bias v2.0 tool and the Jadad score. The primary outcome included patient reported functional outcome measures pooled using standardized mean difference (SMD) and a random effects model. Secondary outcome measures included visual analogue scale (VAS), rate of cosmetic deformity (Popeye sign), range of motion, operative time, and elbow flexion strength. Results. 751 patients from 10 RCTs demonstrated (369 tenotomy vs 382 tenodesis) were included in the meta-analysis. Pooled analysis of all PROMs data demonstrated comparable outcomes between tenotomy vs tenodesis (SMD 0.17 95% CI −0.02 to 0.36, p=0.09). Sensitivity analysis comparing RCTs involving patients with and without an intact rotator cuff did not change the primary outcome. Secondary outcomes including VAS, shoulder external rotation, and elbow flexion strength did not reveal any significant difference. Tenodesis resulted in a lower rate of Popeye deformity (OR 0.27 95% CI 0.16 to 0.45, p<0.00001). Conclusions. Aside from a lower rate of cosmetic deformity, tenodesis yielded no measurable significant benefit to tenotomy for addressing pathology in the long head of biceps. This finding was irrespective of the whether the rotator cuff was intact


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVIII | Pages 111 - 111
1 Sep 2012
Manolescu AR Johnston DWC Weber D Russel K Rigal W Greidanus TH McMillan J Beaupre L
Full Access

Purpose. Primary total hip arthroplasty (THA) has been a very successful surgical intervention for the management of end-stage arthritis in geriatric patients (> age 65). The mid- to long-term results have been less satisfactory however, in younger patients primarily due to the wear of the acetabular liner and loosening of the femoral component. The primary study purpose was to compare pain, function and stiffness over the first five years in a population less than 60 years of age who received either an alumina liner/alumina femoral head (alumina group) or a crossfire UHMWPE liner/alumina head (Poly group) following primary THA. Secondarily, we compared re-operation rates over five years between these two groups. Method. This was a randomized, controlled clinical trial of subjects with non-inflammatory OA who were booked for primary THA and consented to participate in the study. Subjects were evaluated pre-operatively and again at one and five years post-operatively by an evaluator who was blinded to group allocation. At each assessment, subjects completed the WOMAC Osteoarthritis Index (WOMAC); complications and re-operations were also recorded. All analyses were performed on an intention to treat basis. Results. 92 subjects were enrolled in the study. The mean age of subjects was 52.4 (SD 6.8) and 50 (54%) were male and was similar between groups (p>0.10). Baseline pain, function and stiffness as measured by the WOMAC were also similar between groups (p>0.48). Five-year follow-up data was available for 78 (85%) patients. Both groups showed substantial improvement in pain, function and stiffness within one year that was maintained out to five years post-operatively; there were no statistically significant differences between groups (p>0.50). Four subjects required re-operation within five years; no re-operation was related to liner type two cases were dislocation due to the malposition of the cup while the remaining two re-operations occurred in the immediate post-operative period for removal of hematoma. Conclusion. Our prospective randomized controlled trial showed substantial post-operative improvements in pain, stiffness, and function that were maintained out to five years, with no statistically significant differences seen between the two groups. No re-operations that were related to the liner type occurred in the first five post-operative years


The Bone & Joint Journal
Vol. 102-B, Issue 10 | Pages 1303 - 1310
3 Oct 2020
Kjærgaard K Ding M Jensen C Bragdon C Malchau H Andreasen CM Ovesen O Hofbauer C Overgaard S

Aims. The most frequent indication for revision surgery in total hip arthroplasty (THA) is aseptic loosening. Aseptic loosening is associated with polyethylene liner wear, and wear may be reduced by using vitamin E-doped liners. The primary objective of this study was to compare proximal femoral head penetration into the liner between a) two cross-linked polyethylene (XLPE) liners (vitamin E-doped (vE-PE)) versus standard XLPE liners, and b) two modular femoral head diameters (32 mm and 36 mm). Methods. Patients scheduled for a THA were randomized to receive a vE-PE or XLPE liner with a 32 mm or 36 mm metal head (four intervention groups in a 2 × 2 factorial design). Head penetration and acetabular component migration were measured using radiostereometric analysis at baseline, three, 12, 24, and 60 months postoperatively. The Harris Hip Score, University of California, Los Angeles (UCLA) Activity Score, EuroQol five-dimension questionnaire (EQ-5D), and 36-Item Short-Form Health Survey questionnaire (SF-36) were assessed at baseline, three, 12, 36, and 60 months. Results. Of 220 screened patients, 127 were included in this study. In all, 116 received the allocated intervention, and 94 had their results analyzed at five years. Head penetration was similar between liner materials and head sizes at five years, vE-PE versus XLPE was -0.084 mm (95% confidence interval (CI) -0.173 to 0.005; p = 0.064), and 32 mm versus 36 mm was -0.020 mm (95% CI -0.110 to 0.071; p = 0.671), respectively. No differences were found in acetabular component migration or in the patient-reported outcome measures. Conclusion. No significant difference in head penetration was found at five years between vE-PE and XLPE liners, nor between 32 mm and 36 mm heads. Cite this article: Bone Joint J 2020;102-B(10):1303–1310


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_1 | Pages 1 - 1
1 Feb 2021
Tavakoli A Faber K Langohr G
Full Access

Introduction. Total shoulder arthroplasty (TSA) is an effective treatment to restore shoulder function and alleviate pain in the case of glenohumeral arthritis [1]. Stress shielding, which occurs when bone stress is reduced due to the replacement of bone with a stiffer metallic implant, causes bone resorption of up to 9% of the humeral cortical thickness following TSA [2]. Shorter length stems and smaller overall geometries may reduce stress shielding [3], however the effect of humeral head backside contact with the resection plane has not yet been fully investigated on bone stress. Therefore, the purpose of this study was to quantify the effect of humeral head contact conditions on bone stresses following TSA. Methods. 3D models of eight male left cadaveric humeri (68±6 years) were generated from CT data using MIMICS. These were then virtually prepared for reconstruction by an orthopaedic surgeon to accept a short-stem humeral implant (Exactech Equinoxe® Preserve) that was optimally sized and placed centrally in the humeral canal. The humeral head was positioned in the inferior-medial position such that contact was achieved on the medial cortex, and no contact existed on the lateral cortex. Three different humeral head backside contact conditions were investigated (Figure 1); full backside contact (FULL), contact with only the inferior-medial half of the resection (INF), and contact with only the superior-lateral half of the resection (SUP). Cortical bone was assigned an elastic modulus of 20 GPa and a Poisson's ratio of 0.3. Trabecular bone was assigned varying stiffness based on CT attenuation [4]. A joint reaction force was then applied representing 45˚ and 75˚ of abduction [5]. Changes in bone stress, as well as the expected bone response based on change in strain energy density [6] was then compared between the intact and reconstructed states. Results. For cortical bone, the full backside contact altered bone stress by 28.9±5.5% compared to intact, which was significantly less than the superior (37.0±3.9%, P=0.022) and inferior (53.4±3.9%, P<0.001) backside contact conditions. Similar trends were observed for changes in trabecular bone stress relative to the intact state, where the full backside contact altered bone stress by 86.3±27.9% compared to intact, compared to the superior and inferior contact conditions, which altered bone stress by 115.2±45.0% (P=0.309) and 197.4±80.2% (P=0.024), respectively. In terms of expected bone response, both the superior and inferior contact resulted in an increase in bone volume with resorbing potential compared to the full contact (Figure 2). Discussion and Conclusions. The results of this study show that full humeral head backside contact with the humeral resection plane is preferable for short stem humeral TSA implants with the head in the inferior-medial position. As expected, the superior contact typically increased resorption potential in the medial quadrant due to the lack of load transfer, however interestingly the inferior contact increased resorption potential in both the lateral and medial quadrants. Analysis of implant micromotion showed that medial liftoff of the implant occurred, which resulted in a lack of load transfer in the most medial aspect of the resection plane. For any figures or tables, please contact the authors directly


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 76 - 76
1 Aug 2020
Habis A Bicknell R Mei X
Full Access

Reverse shoulder arthroplasty (RSA) has an increasing effective use in the treatment of patients with a variety of diagnoses, including rotator cuff deficiency, inflammatory arthritis, or failed shoulder prostheses. Glenoid bone loss is not uncommonly encountered in these cases due to the significant wear. Severe bone loss can compromise glenoid baseplate positioning and fixation, consequently increasing the risk for early component loosening, instability, and scapular notching. To manage severe glenoid bone deficiencies, bone grafts are commonly used. Although, many studies report outcome of bone grafting in revision RSA, the literature on humeral head autograft for glenoid bone loss in primary RSA is less robust. The purpose of this study is to evaluate the clinical and radiographic outcomes of primary RSA with humeral head autograft for glenoid bone loss at our institution. Institutional review board approval was obtained to retrospectively review the records of 22 consecutive primary RTSA surgeries in 21 patients with humeral head autograft for glenoid bone loss between January 2008 and December 2016. Five patients died during follow-up, three were unable to be contacted and one refused to participate, leaving a final study cohort of 12 patients with 13 shoulders that underwent RSA. All patients had a clinical evaluation including detailed ROM and clinical evaluation using the American Shoulder and Elbow Surgeons (ASES) Score, Constant Score, Western Ontario Osteoarthritis of the Shoulder Index (WOOS), and Short Form-12 (SF-12) questionnaires. Preoperative and postoperative plain radiographs and CT scans were assessed for component position, loosening, scapular notching, as well as graft incorporation, resorption, or collapse. There were 6 males and 6 females, with an average age of 74 ± 6.8 years. The average BMI was 31.7 ± 5.3, and the median ASA score was 3. Average follow-up was 3.4 ± 1.1 years. The average postoperative range of motion measurements for the operative arm are: flexion = 120 ± 37, abduction = 106 ± 23, external rotation = 14 ± 12, internal rotation at 90 degrees of abduction = 49 ± 7, external rotation at 90 degrees of abduction = 50 ± 28. Average functional scores are: ASES: 76.9 ± 19.2, WOOS: 456 ± 347, SF12 physical: 34.2 ± 8.2, SF12 mental: 54.1 ± 10.2, Constant Score: 64.6 ± 14. No evidence of hardware loosening or evidence of bone graft resorption were encountered. On CT, the average of pre operative B-angle was 79.3 ± 9.3 while the pre operative reverse shoulder angle was 101.4 ± 28. Glenoid retroversion average on CT was 13.3 ± 16.6. Post operative baseplate inclination average was 82 ± 7.4 while the baseplate version 7.8 ±10. The operative technique was able to achieve up to 30 degrees of inclination correction and up to 50 degrees of version correction. In conclusion, primary reverse shoulder arthroplasty with humeral head autograft for glenoid bone loss provides excellent ROM and functional outcomes at mid-term follow-up. This technique has a high rate of bone incorporation and small risk of bone resorption at mid term follow up


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_6 | Pages 150 - 150
1 Jul 2020
Paul R Khan R Whelan DB
Full Access

Fibular head avulsion fractures represent a significant injury to the posterolateral corner of the knee. There is a high rate of concomitant injuries including rupture of the cruciate ligaments. Surgical fixation is indicated to restore stability, protect repaired or reconstructed cruciate ligaments and possibly decrease the likelihood of degenerative change. The current presentation describes a novel technique which provides secure fixation to the fibular head, restoring integrity of the posterolateral ligament complex and facilitating early motion. We also present a case series of our experience by a single surgeon at our tertiary referral center. Twenty patients underwent open reduction and internal fixation between 2006 and 2016 using a large fragment cannulated screw and soft tissue washer inserted obliquely from the proximal fibula to tibia. Fixation was augmented with suture repair of the lateral collateral ligament and biceps tendon. The orientation of the fracture was assessed based on preoperative imaging. Repair / reconstruction of concomitant injuries was performed during the same procedure. Early range of motion was initiated at 2 weeks postoperatively under physical therapy guidance. All patients returned for clinical and radiographic assessment (average 3.5 years). All fractures went on to bony union. There were no reoperations for recurrent instability. All patients regained functional range of motion with mean extension of 0.94 degrees and mean flexion of 121.4 degrees. Two patients underwent hardware removal. One patient developed a late local infection, which occurred greater than 5 years after surgery. Eleven patients underwent postoperative varus stress radiographs which demonstrated less than 1 mm difference between the operated and contralateral side. Fracture morphology typically demonstrated an oblique pattern in the coronal plane and a transverse pattern in the sagittal plane. This study represents a novel surgical technique for the repair of fibular head avulsion fractures with a large fragment cannulated screw placed obliquely from the fibula to tibia. Fixation is augmented with a soft tissue washer and suture repair. Our results suggest that this technique allows for early range of motion with maintenance of reduction, high rates of union, and excellent postoperative stability


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_2 | Pages 71 - 71
1 Feb 2020
Sipek K Gustafson J McCarthy S Hall D Lundberg H Levine B Pourzal R
Full Access

Introduction. Total hip arthroplasty (THA) is a commonly performed procedure to relieve arthritis or traumatic injury. However, implant failure can occur from implant loosening or crevice corrosion as a result of inadequate seating of the femoral head onto the stem during implantation. There is no consensus—either by manufacturers or by the surgical community—on what head/stem assembly procedure should be used to maximize modular junction stability. Furthermore, the role of “off-axis” loads—loads not aligned with the stem taper axis—during assembly may significantly affect modular junction stability, but has not been sufficiently evaluated. Objective. The objective of this study was to measure the three-dimensional (3D) head/stem assembly loads considering material choice—metal or ceramic—and the surgeon experience level. Methods. A total of 29 surgeons of varying levels (Attending, Fellow, Resident) were recruited and asked to perform a benchtop, head/stem assembly using an instrumented apparatus simulating a procedure in the operating room (Figure 1). The apparatus comprised of a 12/14 stem taper attached to a 3D load sensor (9347C, Kistler® USA, Amherst, NY). Surgeons were randomly assigned a metal or ceramic femoral head and instructed to assemble the taper using their preferred surgical technique. This procedure was repeated five times. Surgeons were brought back to test the opposite material after four weeks. Output 3D load data was analyzed for differences in peak vertical load applied, angle of deviation from the stem axis—termed off-axis angle, variability between trials, and impaction location. Results. Preliminary results suggest no significant differences between the loads applied to the metal heads and the ceramic heads. Across the two materials tested, both attendings and residents applied greater loads than fellows (p=0.33; Residents=9.0 kN vs Fellow=7.2 kN: p=0.27; Attendings=8.9 kN vs 7.2 kN) with significantly less variability (Attendings: σ= 1.58; Fellows: σ= 3.26; Residents: σ= 2.86). Attending surgeons also exhibited applied loads at significantly lower off-axis angles compared to fellows (p=0.01; 4.6° vs Fellow=7.2°) (Figure 2). However, all of our clinicians assembled ceramic head tapers with a greater off-axis angle as compared to assembling metal heads. In addition, metal heads were impacted more on-axis for all surgeon experience levels (Figure 3). While the impaction load plots suggest that the first impact strike is the most crucial for head stability, it was determined that the number of strikes is not as important as the maximum impaction load applied. Conclusion. Differences in impaction load when assembling metal and ceramic femoral heads were not apparent; however, variability of technique and load was observed across the different surgical experience levels as well as within surgeons of the same level. Understanding assembly mechanics and surgical habits for THA will provide insight to the best assembly procedures for these implants. For any figures or tables, please contact authors directly


Bone & Joint Research
Vol. 8, Issue 9 | Pages 414 - 424
2 Sep 2019
Schmalzl J Plumhoff P Gilbert F Gohlke F Konrads C Brunner U Jakob F Ebert R Steinert AF

Objectives. The long head of the biceps (LHB) is often resected in shoulder surgery and could therefore serve as a cell source for tissue engineering approaches in the shoulder. However, whether it represents a suitable cell source for regenerative approaches, both in the inflamed and non-inflamed states, remains unclear. In the present study, inflamed and native human LHBs were comparatively characterized for features of regeneration. Methods. In total, 22 resected LHB tendons were classified into inflamed samples (n = 11) and non-inflamed samples (n = 11). Proliferation potential and specific marker gene expression of primary LHB-derived cell cultures were analyzed. Multipotentiality, including osteogenic, adipogenic, chondrogenic, and tenogenic differentiation potential of both groups were compared under respective lineage-specific culture conditions. Results. Inflammation does not seem to affect the proliferation rate of the isolated tendon-derived stem cells (TDSCs) and the tenogenic marker gene expression. Cells from both groups showed an equivalent osteogenic, adipogenic, chondrogenic and tenogenic differentiation potential in histology and real-time polymerase chain reaction (RT-PCR) analysis. Conclusion. These results suggest that the LHB tendon might be a suitable cell source for regenerative approaches, both in inflamed and non-inflamed states. The LHB with and without tendinitis has been characterized as a novel source of TDSCs, which might facilitate treatment of degeneration and induction of regeneration in shoulder surgery. Cite this article: J. Schmalzl, P. Plumhoff, F. Gilbert, F. Gohlke, C. Konrads, U. Brunner, F. Jakob, R. Ebert, A. F. Steinert. Tendon-derived stem cells from the long head of the biceps tendon: Inflammation does not affect the regenerative potential. Bone Joint Res 2019;8:414–424. DOI: 10.1302/2046-3758.89.BJR-2018-0214.R2


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 46 - 46
1 Nov 2018
Tuleubayev B Saginova D Arutyunyan M Kerimbekov T Uulu AD
Full Access

Recently in traumatology various methods of impregnation biodegradable implants and allografts with antibiotics are widely used. Among them the soaking, shaking and ionophores are common used. We aimed to choose the optimal method of impregnation with the antibiotic of the head of the femur, taken from patients after arthroplasty. We studied 6 femoral heads after hip replacement. Head №1 the iohexol (Omnipaque) was injected through circular ligament and through the neck of the femur. Head №2 through the circular ligament, head №3 through the neck of the femur, head №4 through the circular ligament and through the neck of the femur, head №5 through 4 pre-drilled channels a brilliant green solution was injected. The head №6 was soaked in a brilliant green solution. Head №1 assessed by radiology. All the heads, treated with brilliant green, were cut in half to assess the degree of impregnation. On the X-ray image of head №1 the contrast agent has spread enough. In osteotomy, the impregnation with brilliant green head №2, №3, №4, №5 was seen in 3–4 mm around the needle passage place. Head №6 the bone was not impregnated. Despite the fact that the radiograph showed a sufficient spread of contrast agent, on the sections of the head, treated with brilliant green, showed the spread of liquid 3–4 mm around the needle passage place. This indicates that the impregnation of large bone is not effective


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_1 | Pages 59 - 59
1 Jan 2018
Morlock M Bishop N Huber G Bünte D
Full Access

Taper corrosion in Total Hip Arthroplasty has surfaced as a clinically relevant problem and has recently also been reported for metal heads against polyethylene. Low neck stiffness is a critical contributing factor. Catastrophic taper failures have been reported for one particular stem design with a small V-40 taper made from a less stiff titanium-alloy. The purpose of this study was to identify factors involved in the failure process. 31 revised CoCr heads ranging from 32 to 44m diameter combined with TMZF-Titanium alloy stem with a V-40 taper (Accolade I) were analysed. Stems were only available for catastrophic failure cases with dis-association (n=8) or taper fracture (n=1). Clinical data were limited to time-in-situ, patient gender and age. Head material loss increased with time in situ (r²=0.49, p<0.001). Longer heads and material loss exceeding 15mm³ showed bottoming out and consecutive catastrophic stem taper failure. Heads with failed stem tapers were all 36mm diameter. The head starts rotating on the stem taper after bottoming out, causing major abrasive wear, ultimately resulting in catastrophic failure; it is surprising that these catastrophic cases did not exhibit clinical symptoms due to raised Co and Cr metal ions, which must have resulted from the large amount of CoCr lost from the female head taper. This would have attracted medical attention and prevented catastrophic failure by taper dis-association. Control exams of patients treated with the respective stem type in combination with large CoCr heads should include metal ion determination in blood or serum, even if no clinical symptoms are present, in order to detect taper corrosion before catastrophic failure occurs


Bone & Joint Research
Vol. 5, Issue 8 | Pages 338 - 346
1 Aug 2016
MacLeod AR Sullivan NPT Whitehouse MR Gill HS

Objectives. Modular junctions are ubiquitous in contemporary hip arthroplasty. The head-trunnion junction is implicated in the failure of large diameter metal-on-metal (MoM) hips which are the currently the topic of one the largest legal actions in the history of orthopaedics (estimated costs are stated to exceed $4 billion). Several factors are known to influence the strength of these press-fit modular connections. However, the influence of different head sizes has not previously been investigated. The aim of the study was to establish whether the choice of head size influences the initial strength of the trunnion-head connection. Materials and Methods. Ti-6Al-4V trunnions (n = 60) and two different sizes of cobalt-chromium (Co-Cr) heads (28 mm and 36 mm; 30 of each size) were used in the study. Three different levels of assembly force were considered: 4 kN; 5 kN; and 6 kN (n = 10 each). The strength of the press-fit connection was subsequently evaluated by measuring the pull-off force required to break the connection. The statistical differences in pull-off force were examined using a Kruskal–Wallis test and two-sample Mann–Whitney U test. Finite element and analytical models were developed to understand the reasons for the experimentally observed differences. Results. 36 mm diameter heads had significantly lower pull-off forces than 28 mm heads when impacted at 4 kN and 5 kN (p < 0.001; p < 0.001), but not at 6 kN (p = 0.21). Mean pull-off forces at 4 kN and 5 kN impaction forces were approximately 20% larger for 28 mm heads compared with 36 mm heads. Finite element and analytical models demonstrate that the differences in pull-off strength can be explained by differences in structural rigidity and the resulting interface pressures. Conclusion. This is the first study to show that 36 mm Co-Cr heads have up to 20% lower pull-off connection strength compared with 28 mm heads for equivalent assembly forces. This effect is likely to play a role in the high failure rates of large diameter MoM hips. Cite this article: A. R. MacLeod, N. P. T. Sullivan, M. R. Whitehouse, H. S. Gill. Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability. Bone Joint Res 2016;5:338–346. DOI: 10.1302/2046-3758.58.BJR-2016-0044.R1