Mixed Reality has the potential to improve accuracy and reduce required dissection for the performance of peri-acetabular osteotomy. The current work assesses initial proof of concept of MR
Osteoarthritis (OA) is a common cause of chronic pain. Subchondral bone is highly innervated, and bone structural changes directly correlate with pain in OA. Mechanisms underlying skeletal–neural interactions are under-investigated. Bone derived axon
Aims. The aim of the British Association for Surgery of the Knee (BASK) Meniscal Consensus Project was to develop an evidence-based treatment guideline for patients with meniscal lesions of the knee. Materials and Methods. A formal consensus process was undertaken applying nominal group, Delphi, and appropriateness methods. Consensus was first reached on the terminology relating to the definition, investigation, and classification of meniscal lesions. A series of simulated clinical scenarios was then created and the appropriateness of arthroscopic meniscal surgery or nonoperative treatment in each scenario was rated by the group. The process was informed throughout by the latest published, and previously unpublished, clinical and epidemiological evidence. Scenarios were then grouped together based upon the similarity of clinical features and ratings to form the guideline for treatment. Feedback on the draft guideline was sought from the entire membership of BASK before final revisions and approval by the consensus group. Results. A total of 45 simulated clinical scenarios were refined to five common clinical presentations and six corresponding treatment recommendations. The final guideline stratifies patients based upon a new, standardized classification of symptoms, signs, radiological findings, duration of symptoms, and previous treatment. Conclusion. The 2018 BASK Arthroscopic Meniscal Surgery Treatment
Abstract. Objective. Open fracture management in the United Kingdom and several other countries is guided by the British Orthopaedic Association's Standards for Trauma Number 4 (BOAST-4). This is updated periodically and is based on the best available evidence at the time. The aim of this study is to evaluate the evidence base forming this
Aim. Bone and joint infection requires antimicrobial treatment for 6 to 12 weeks. When patients are well prepared and instructed regarding their therapy, they are more likely to have less side effects and improved compliance. Although side effects are common, this coaching is often not routinely performed when oral treatment is given. We developed a monitoring and
Tourniquet is a commonly used tool in orthopaedic practice. Incidence of complications is low but if any develops, it is devastating. Transient nerve damage, ischemia or skin burns are the possible tourniquet related complications. There is big variation in practice regarding the limb occlusion pressure. 51 procedures in 50 patients were reviewed retrospectively in our district general hospital. We looked at quality of documentation guided by the BOAST standard (The Safe Use of Intraoperative Tourniquets, published in October 2021). Limb occlusion pressure and ischemic time were analysed. Intra-operative and post-operative notes were reviewed to assess quality of documentation and post-operative complications. Although limb occlusion pressure was above the recommended range in more than 75% of cases, there were no significant complications observed. Two cases only developed transient neuropraxia in common peroneal nerve and median nerve following tibial plateau ORIF and trapeziectomy simultaneously. Tibial ORIF fixation case had prolonged ischemic time (more than 120 minutes) and the limb occlusion pressure for the hand case was above the recommended range. Both have recovered within few days with no long-term consequences. Minimum documentation threshold was not met with regarding tourniquet site condition, method of skin isolation and padding, and exsanguination method. This relatively new standard with no previous similar
Total knee arthroplasty (TKA) is a common procedure with good success rates. The literature shows resection accuracy plays a crucial role in device longevity. 1. Computer
Introduction. Clinical outcomes for total knee arthroplasty (TKA) are especially sensitive to lower extremity alignment and implant positioning. 1. The use of computer-assisted orthopedic surgery (CAOS) can improve overall TKA accuracy. 2. This study assessed the accuracy of an image-free CAOS
Beside spine and pelvis surgery, computer-assisted
Fractures of the femoral head are a challenging problem. The most often performed head preserving procedure worldwide is closed reduction and insertion of cannulated screws under fluoroscopic control. The use of navigation is still experimental in general trauma since rigid reference markers must be attached to all fragments. The examined system (Surgix®, Tel Aviv, Israel) is a fluoroscopy based image analysing system. It consists of a workstation and X-ray opaque markers in surgical tools. When the tool is visible in a C-arm shot a trajectory is displayed as additional layer in the image to serve as
Percutaneous fixation of scaphoid fractures has become popular in recent years, mainly due to its reduced complexity compared to open surgical approaches. Fluoroscopy is currently used as
Background. Total Shoulder Arthroplasty (TSA) has been shown to improve the function and pain of patients with severe degeneration. Recently, TSA has been of interest for younger patients with higher post-operative expectations; however, they are treated using traditional surgical approaches and techniques, which, although amenable to the elderly population, may not achieve acceptable results with this new demographic. Specifically, to achieve sufficient visualization, traditional TSA uses the highly invasive deltopectoral approach that detaches the subscapularis, which can significantly limit post-operative healing and function. To address these concerns, we have developed a novel surgical approach, and
Clinical outcomes for total knee arthroplasty (TKA) are especially sensitive to lower extremity alignment and implant positioning. The use of computer-assisted orthopedic surgery (CAOS) can improve overall TKA accuracy. This study assessed the accuracy of an image-free CAOS
Introduction. Clinical outcomes for total knee arthroplasty (TKA) are especially sensitive to lower extremity alignment and implant positioning. 1. The use of computer-assisted orthopaedic surgery (CAOS) can improve overall TKA accuracy. 2. This study assessed the accuracy of an image-free CAOS
Introduction. The Birmingham Hip Resurfacing (Smith & Nephew London, UK) is the most popular hip resurfacing (HR) in the UK. However, it is now subject to two Medical Device Alerts (MDA) from the Medicines and Healthcare products Regulatory Agency (MHRA). Patients/Materials & Methods. A cross-sectional survey of primary metal-on-metal hip procedures recorded on the National Joint Registry for England, Wales and Northern Ireland (NJR) until 5. th. November 2013 was performed. Cost-analysis was based on an algorithm for surveillance of HR at a tertiary referral centre and followed previous MHRA
Background: To assess the accuracy of pedicle instrumentation placement using an image
Introduction. From pre-operative planning to final implant cementation, total knee arthroplasty (TKA) can be defined by a succession of individual steps, each presenting potential errors that can result in devices being implanted outside the desired range of alignment. Our study used an image-free computer-assisted orthopedic surgery (CAOS)
Aim: To study the effect intra-operative image
Purpose: We report the operative technique and preliminary results for percutaneous osteosynthesis in the supine position with computed tomography
Introduction. Accurate component placement in total hip arthroplasty (THA) improves post-operative stability and reduces wear and aseptic loosening. Methods for achieving accurate stem placement have not been as extensively studied as cup placement. Objectives. The purpose of this study is to determine how consistently femoral stem version can be corrected to an ideal of 15 +/− 5 degrees using robotic