Aims. The aim of this investigation was to compare risk of infection in both cemented and uncemented hemiarthroplasty (HA) as well as in total hip arthroplasty (THA) following
Aims. Evaluate if treating an unstable
Aims. In this study, we aimed to explore surgical variations in the
The
Osteonecrosis of the femoral head after
Aims. Traditionally, total hip arthroplasty (THA) templating has been performed on anteroposterior (AP) pelvis radiographs. Recently, additional AP hip radiographs have been recommended for accurate measurement of the femoral offset (FO). To verify this claim, this study aimed to establish quantitative data of the measurement error of the FO in relation to leg position and X-ray source position using a newly developed geometric model and clinical data. Methods. We analyzed the FOs measured on AP hip and pelvis radiographs in a prospective consecutive series of 55 patients undergoing unilateral primary THA for hip osteoarthritis. To determine sample size, a power analysis was performed. Patients’ position and X-ray beam setting followed a standardized protocol to achieve reproducible projections. All images were calibrated with the KingMark calibration system. In addition, a geometric model was created to evaluate both the effects of leg position (rotation and abduction/adduction) and the effects of X-ray source position on FO measurement. Results. The mean FOs measured on AP hip and pelvis radiographs were 38.0 mm (SD 6.4) and 36.6 mm (SD 6.3) (p < 0.001), respectively. Radiological view had a smaller effect on FO measurement than inaccurate leg positioning. The model showed a non-linear relationship between projected FO and
Aims. Accumulated evidence indicates that local cell origins may ingrain differences in the phenotypic activity of human osteoblasts. We hypothesized that these differences may also exist in osteoblasts harvested from the same bone type at periarticular sites, including those adjacent to the fixation sites for total joint implant components. Methods. Human osteoblasts were obtained from the acetabulum and
Aims. The aim of this study was to determine the association between knee alignment and the vertical orientation of the
Aims. Surgical treatment of young
Three Cannulated Screws (3CS), Dynamic Hip Screw (DHS) with antirotation screw (DHS–Screw) or with a Blade (DHS–Blade) are the gold standards for fixation of unstable
Abstract. INTRODUCTION. Fracture
The current evidence favors replacement for the treatment of displaced
The covid-19 pandemic had a great impact in the daily clinical and surgical practice. Concerning patients with a
Introduction.
Aims. The localization of necrotic areas has been reported to impact the prognosis and treatment strategy for osteonecrosis of the femoral head (ONFH). Anteroposterior localization of the necrotic area after a
C. Difficile infections in elderly patients with hip fractures is associated with high morbidity and mortality. Antibiotic regimens with penicillin and its derivatives is a leading cause. Antibiotic prophylactic preferences vary across different hospitals within NHS. We compared two antibiotic prophylactic regimens - Cefuroxime only prophylaxis and Teicoplanin with Gentamicin prophylaxis in fracture
Aims. Total hip arthroplasty (THA) is considered the preferred treatment for displaced proximal
Aims. Our primary aim was to assess reoperation-free survival at one year after the index injury in patients aged ≥ 75 years treated with internal fixation (IF) or arthroplasty for undisplaced