Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_12 | Pages 5 - 5
1 Jun 2017
McConnell J Young S
Full Access

When inserting a femoral stem, surgeons make use of many visual and tactile cues to be sure that the implant is correctly sized and well-seated. One such cue is the change of pitch that can be heard when the final femoral broach is inserted. This is known to be important, but has not been widely studied. We set out to analyse the sounds produced during femoral broaching and implant fixation, and to discover whether the absence of these sounds could predict a poor fixation. We recorded the sound of femoral broaching and definitive implant insertion, for twenty un-cemented Corail total hip replacements. Procedures were performed by the same surgeon, in the same theatre. The recordings were visualised using audio editing software, and a Fast Fourier Transform was used to identify the dominant audio frequencies. In 19 of the 20 cases, the final strikes of the final femoral broach displayed a distinctive pattern, with the most prominent frequencies being harmonics (multiples of a fundamental frequency) which had a wavelength directly related to the length of the femoral canal. This contrasts with initial strikes, where multiple unrelated frequencies were present. Postoperative radiographs were examined by two surgeons independently, to assess implant sizing and positioning. The one case, in which the harmonic pattern was not observed, was found on radiographs to be an undersized, varus malpositioned implant. We demonstrate that a characteristic frequency pattern is present when impacting cancellous bone with a well-sized and well-placed femoral broach. When the pattern was absent, the broach and implant were undersized and malpositioned. We hypothesise that this pattern arises when broach and femur are vibrating as one, indicating adequate contact with, and compression of, cancellous bone


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_1 | Pages 17 - 17
1 Jan 2013
Whitwell G Brockett C Young S Stone M Stewart T
Full Access

Introduction

During broach preparation and implant insertion of the proximal femur the surgeon may be able to use audible pitch changes to judge broaching adequacy and implant position. The aim of this study was to analyse the sound produced and explain the sound spectra using acoustic physics.

Methods

A highly sensitive microphone was used to digitally record the sound made during femoral preparation and definitive implant insertion in 9 patients undergoing total hip arthroplasty. The sound data was analysed using a fast Fournier transformation spectrum analyser. The highest 4 peak spectral amplitudes of the first broach, the last strike of the final broach and the definitive implant were recorded. The sound spectra produced by striking the implant introducer in isolation were analysed in a similar manner.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_11 | Pages 7 - 7
7 Jun 2023
Vandeputte F Hausswirth C Dille J Corten K
Full Access

Total Hip Arthroplasty (THA) surgery is a physical and cognitive challenge for surgeons. Data on stress levels, cognitive and physical load of orthopaedic surgeons, as well as ergonomic impact, are limited. With and without the use of an automated impaction device, operational efficiency and the surgeon's ergonomic, mental, and physical load was investigated. In a total of thirty THA procedures, a standard manual technique was compared with an automated impaction device. Three computerized cognitive tasks (Simon, pattern comparison, and pursuit rotor) and five physical tests (isometric wall-sit, plank-to-fatigue, handgrip, supra-postural task, and shoulder endurance) were used to assess psychophysiological load of the surgeon. Surgeon's cortisol concentration was evaluated from saliva samples. Postural risk was assessed by Rapid Upper Limb Assessment (RULA) and Rapid Entire Body Assessment (REBA). Efficiency was assessed by timing surgical steps and instrumentation flow. Cognitive performances after automated impaction showed faster response times and lower error rates with a greater time-on-target (+1.5 s) and a lower mouse deviation from target (−1.7 pixels). Manual impaction showed higher physical exhaustion in the isometric wall-sit test (10.6% vs. 22.9%), plank-to-fatigue (2.2% vs. 43.8%), the number of taps in the supra-postural task (−0.7% vs. −7.7%), handgrip force production in the dominant (−6.7% vs. −12.7%) and contralateral hand (+4.7% vs. +7.7%), and in shoulder endurance (−15s vs. −56s). An increase of 38.2% in salivary cortisol concentration between the midday (1.31 nmol/l) and afternoon session (1.81 nmol/l) was observed with manual impaction. After using automated impaction, salivary cortisol concentration decreased (−51.2%). Manual broaching time was on average 6′20’’ versus 7’3’’ with automated impaction. RULA of manual impaction scored 6 for cup impaction and 5 for femoral broaching, versus 3 and 3 for automated impaction, respectively. REBA of manual impaction scored 9 for cup impaction and 5 for femoral broaching, versus 4 and 3 for automated impaction, respectively. Automated impaction lowers surgeons’ cognitive and physical fatigue and leads to reduced stress and improved ergonomics without loss of surgical efficiency


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_6 | Pages 39 - 39
1 Apr 2018
Barnes B Loftus E Lewis A Feskanin H
Full Access

Introduction. Offset femoral broach handles have become more common as the anterior approach in total hip arthroplasty has increased in popularity. The difference in access to the femur compared to a posterior approach necessitates anterior and, in some cases, lateral offsets incorporated into the design of the broach handle to avoid interference with the patient's body and to ensure accessibility of the strike plate. Using a straight broach handle with a primary stem, impaction force is typically directed along the axis of the femoral broach. However, the addition of one or more offsets to facilitate an anterior approach results in force transmission in the transverse plane, which is unnecessary for eating the femoral broach. The direction of forces transmitted to the broach via strike plate impaction can introduce a large moment. A negative consequence of this moment is the amplification of stresses/strains at the bone/broach interface, which increases the likelihood of femoral fracture during impaction. It was proposed that optimizing the angle of the strike plate could minimize the moment to reduce the unintended stresses/strains at the bone/broach interface. Objectives. The objective was to minimize the stresses/strains imparted to the proximal aspect of the bone femur when broaching with a given dual offset broach handle design. Methods. Trigonometric calculations were used to optimize the strike plate angle for a given dual offset broach handle design. The point of intersection of the stem axis and transverse plane that intersects the medial calcar of the smallest size broach was assumed to be the ideal location of zero moment, given that intraoperative fractures related to this issue tend to occur in the proximal region of the femur. The strike plate was angled anteriorly and laterally such that the impaction force vector is directed at this point of intersection, thus negating the moment at this point. A prototype broach handle body was fabricated to accept different strike plates. Of the two strike plates tested, one strike plate was made such that the impaction surface followed the optimized angle, while the other simulated the strike plate angle of a previous, non-optimized design. Each broach handle configuration was connected to an identical broach and implanted into one of two identical Sawbones® femoral models. Equal loads were placed on the strike plates of each handle perpendicular to the strike plate angles. Digital image correlation was used to compare the resultant strains in both samples. Results. Testing demonstrated a 30% reduction in maximum strain on the proximal aspect of the bone using the broach handle with the optimized strike plate. Conclusions. While the optimal strike plate angle is dependent on the individual broach handle design, this method of optimization can be applied to the design of any offset broach handle. Optimization of offset broach handle strike plate angles could reduce the incidence of intraoperative femoral fractures when broaching by reducing the stresses/strains on the proximal aspect of the femur


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 44 - 44
1 Dec 2022
Turgeon T Bohm E Gascoyne T Hedden D Burnell C
Full Access

This study used model-based radiostereometric analysis (MBRSA) to compare migration of a recently introduced cementless hip stem to an established hip stem of similar design. Novel design features of the newer hip stem included a greater thickness of hydroxyapatite coating and a blended compaction extraction femoral broach. Fifty-seven patients requiring primary total hip arthroplasty (THA) were enrolled at a single centre. Patients were randomized to receive either an Avenir collarless stem and Trilogy IT cup (ZimmerBiomet) or a Corail collarless stem and Pinnacle cup (DePuy Synthes) via a posterior or lateral approach. Both stems are broach-only femoral bone preparation. RSA beads (Halifax Biomedical) were inserted into the proximal femur during surgery. Patients underwent supine RSA imaging a 6 weeks (baseline), 6, 12, and 24 months following surgery. The primary study outcome was total subsidence of the hip stem from baseline to 24 months as well as progression of subsidence between 12 and 24 months. These values were compared against published migration thresholds for well-performing hip stems (0.5mm). The detection limit, or precision, of MBRSA was calculated based on duplicate examinations taken at baseline. Patient reported outcome measures were collected throughout the study and included the Oxford-12 Hip Score (OHS), EuroQoL EQ-5D-5L, Hip Osteoarthritis Score (HOOS) as well as visual analogue scales (VAS) for thigh pain and satisfaction. Analysis comprised of paired and unpaired t-tests with significance set at p≤0.05. Forty-eight patients (30 males) were included for analysis; 7 patients received a non-study hip stem intra-operatively, 1 patient suffered a traumatic dislocation within three weeks of surgery, and 1 patient died within 12 months post-surgery. RSA data was obtained for 45 patients as three patients did not receive RSA beads intra-operatively. Our patient cohort had a mean age of 65.9 years (±;7.2) at the time of surgery and body mass index of 30.5 kg/m2 (±;5.2). No statistical difference in total stem migration was found between the Avenir and Corail stems at 12 months (p=0.045, 95%CI: −0.046 to 0.088) and 24 months (p=0.936, 95% CI: −0.098 to 0.090). Progression of subsidence from 12-24 months was 0.011mm and 0.034mm for the Avenir and Corail groups which were not statistically different (p=0.163, 95%CI: −0.100 to 0.008) between groups and significantly less than the 0.5mm threshold (pNo statistically significant differences existed between study groups for any pre-operative function scores (p>0.05). All patients showed significant functional improvement from pre- to post-surgery and no outcome measures were different between study groups with exception of EQ-5D-5L health visual analogue scale at 12 months which showed marginally superior (p=0.036) scores in the Avenir group. This study was not powered to detect differences in clinical outcomes. This study has demonstrated no statistical difference in subsidence or patient-reported outcomes between the Corail hip stem and the more recently introduced Avenir hip stem. This result is predictable as both stems are of a triple-tapered design, are coated with hydroxyapatite, and utilize a broach-only bone preparation technique. Both stem designs demonstrate migration below 0.5mm suggesting both are low-risk for aseptic loosening in the long-term


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 94 - 94
1 Feb 2020
Hagio K Akiyama K Aikawa K Saito M
Full Access

Introduction. In our institution, we started to perform THA with SuperPATH approach, including preservation of soft tissue around the hip (James Chow et al. Musculoskelet Med 2011) since July 2014, aiming for fast recovery and prevention of hip dislocation. For minimally-invasive approaches, however, there have been a few reports on malalignment of the implants related to shortage of operative field. The purpose of this study is to examine the short-term results of THA using SuperPATH, especially implant alignment. Materials and methods. We performed a study of 45 patients (45 hips) with osteoarthritis of the hip joint who had a THA with SuperPATH approach. There were 8 men and 37 women with an average age of 73 years, which were minimally 24 months followed. Dynasty Bioform cup and Profemur Z stem (Microport Orthopaedics) were used for all cases. Patients were clinically assessed with Merle d'Aubigne score and complications. Implant alignment and stability were radiologically evaluated by annual X-ray and CT acquired two months after surgery. Results. Merle d'Aubigne score was 10.2 (pain:2.8, mobility:4.4 walking ability:3.0) preoperatively and 16.6(pain:5.8, mobility:5.8, walking ability:5.0) at the latest follow-up. There were no dislocation and infection, but intraoperative proximal femoral fracture was found for two cases, which was managed to treat with additional circulating wire intraoperatively. Latest follow-up X-ray image showed 95% of the stem A-P alignment to be within 2 degrees and 5% to be more than 2 degrees and less than 5 degrees, while 44% of the stem lateral alignment to be within 2 degrees, 47% to be more than 2 degrees and less than 5 degrees, and 8% to be more than 5 degrees. From CT images averaged cup position found to be 40±5 degrees for inclination, and 19±5 degrees for anatomic anteversion, averaged stem anteversion to be 33±9 degrees. Annual X-ray evaluation showed no radiolucent line and less than Grade 2 stress-shielding (Engh classification) around the implants for all cases. One case had more than 5mm subsidence of the stem in early postoperative period, but not progressively subsided. No loosening of components was evident. Discussion and Conclusion. Many minimally-invasive approaches have developed, there have been many reports on fast recovery and low incidence of postoperative hip dislocation, however, the risk of complications or malalignment related to shortage of operative field has been pointed out. In this study, intraoperative proximal femoral fracture occurred for two cases. Also, though there were no loosening and the components position seemed excellent but lateral view of the X-ray showed 8% to be more than 5 degrees tilting alignment, resulting from femoral broaching required before femoral neck resection. SuperPATH approach, including pass way from between the Gluteus Medius and the piriformis tendon, can preserve the whole short external rotators and capsule of the hip joint, leading to fast recovery and low incidence of postoperative dislocation. Moreover, this approach may be friendly to the surgeons familiar with the posterior approach because of easily conversion to the conventional posterior approach


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_1 | Pages 142 - 142
1 Feb 2020
Nizam I Batra A Gogos S
Full Access

INTRODUCTION. The Woodpecker pneumatic broaching system facilitates femoral preparation to achieve optimal primary fixation of the stem in direct anterior hip replacement using a standard operating table. The high-frequency axial impulses of the device reduce excess bone tension, intraoperative femoral fractures and overall operating time. The Woodpecker device provides uniformity and enhanced control while broaching, optimizing cortical contact between the femur and implant and thereby maximizing prosthetic axial stability and longevity. This study aims to describe a single surgeon's experience using the Woodpecker pneumatic broaching system in 649 cases of direct anterior approach (DAA) total hip arthroplasties to determine the device's safety and efficacy. METHODOLOGY. All consecutive patients undergoing elective anterior bikini total hip arthroplasties (THA) performed by a single surgeon between July 2013 and June 2018 were included. Patients undergoing a THA with the use of the Woodpecker device through a different surgical approach, revision THA or arthroplasties for a fractured neck of femur were excluded (n=219). The pneumatic device was used for broaching the femoral canal in all cases. Pre-operative and post-operative Harris Hip Scores (HHS) and post-operative radiographs were analyzed to identify femoral fractures and femoral component positioning at 6 weeks, 6 months and 12 months post-operative. Any intra-operative or post-operative surgical complications and component survivorship until most recent follow up were recorded in the clinical notes. RESULTS. A total of 649 patients (L THA=317, R THA=328 and bilateral=2) with a mean age of 69 (range 46–91yrs) and mean BMI of 28.3 (range = 18.4–44.0) underwent a DAA THA using a Woodpecker device were included in the study. Of these patients, 521 (80%) underwent uncemented and 128 (20%) underwent cemented femoral components. The time taken to broach the femur using Woodpecker broaching this system averaged 2.8 minutes (1.4 to 7.5 minutes) in both cemented and uncemented cases. In 91% of cases the templated broach size was achieved with the remaining 9% within +/− 1 size of the planned template. Radiographic analysis revealed 67.3% of the stems placed in 0–1.82 degrees of varus and 32.7% placed in 0–1.4 degrees of valgus. Average HHS were 24.4 pre-operatively, with drastic improvements shown at 6 weeks (80.95), 6 months (91.91) and 12 months (94.18) after surgery. Intraoperative femoral fractures occurred in three patients (0.4%) during trial reduction, a further three patients had periprosthetic post-operative fractures (0.4%) from falls, two patients had stem subsidence (0.3%) and a further two patients had wound infections (0.3%). At the most recent follow up, the survivorship of the acetabular component was 99.7% and the femoral component was 99.1%, with mean follow up of 2.9 years (0.5 to 5 years). No intraoperative or post-operative complications could be directly attributed to the Woodpecker broaching system. CONCLUSION. The pneumatic Woodpecker device is a safe and effective alternative tool in minimally invasive direct anterior hip replacement surgery for femoral broaching performed on a standard operating table. The skill and experience of the surgeon must be taken into consideration when utilizing new surgical devices


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 421 - 421
1 Nov 2011
Lovell T Hozack W Kreuzer S Merritt P Nogler M Puri L Wuestemann T Bastian A
Full Access

The current decade has seen a marked rise in popularity of minimally invasive hip replacement, done through a variety of surgical approaches. A specific downside to the direct anterior approach includes the significant difficulty getting a “straight shot” down the femoral canal for either straight, nonflexible reaming or broaching as with standard approaches. Improper alignment in the femoral canal can lead to sub-optimal load transfer and thus compromised fixation. The femoral broach and stem insertion path for this approach is best described as a curved one, rather than the typical straight path. Some femoral components appear to be more suitable to this technique due to their geometries. The purpose of the study was to describe the effects that the single geometric parameter, stem length, has on its insertion path into the femoral canal. Due to the potential introduction of human error associated with repetitively performing a specific motion, both a physical study and a computer generated analysis were conducted. For the physical portion of the study, a femoral implant body of generic fit and fill geometry was designed and manufactured. The length of the stem was varied from 40 mm to 100 mm in 10 mm increments. A medium sized synthetic femur (Sawbones, Pacific Labs, Seattle, WA) was machined to match the volume of the full length stem. The insertion path constraints were defined such that the stem had to maintain the greatest allowable insertion angle while still making contact on both the medial and lateral side of the canal during translation in the X direction. To reduce the variability in applying the constraints, a single author conducted the insertion procedure for each length stem while the path was videotaped from a fixed position directly in front of the setup. The most proximal lateral point of the stem was tracked through the insertion path and the X, Y coordinates were recorded at a frequency of 2 FPS. The area under this curve, referred to as the minimum insertion area (MIA), was calculated. For the computer generated portion of the study, a CAD model of the standard length Omnifit. ®. (Stryker Orthopaedics) was utilized. The stem was modified to create 5 additional models where the length was progressively shortened to 65%, 55%, 45%, 35%, and 25% of original length or 91mm, 77mm, 63mm, 49mm, and 35mm respectively. The femur was created from a solidified mesh of a computed tomography (CT) scan with the canal virtually broached for a full length stem. The models were each virtually assembled within the femoral canal with the similar constraints as the physical study. Again, the most proximal lateral point of the stem was tracked through the insertion path with the coordinates recorded and the MIA was calculated. There was a non-linear relationship between stem length and the MIA with the rate of change decreasing as the stem length decreased. That is, the greatest decrease in MIA was between the standard length and next longest length in the computer simulation. It was noted that marked change in MIA began to subside between the 77mm and 63mm stems and continued this trend of having less influence onward through to the shorter lengths. Although the results of the physical study showed a higher variability than the computer generated portion, it does confirm the results of the computer generated study. Minimizing the trauma associated with THR has led most of the above authors to the direct anterior approach. However, the femoral broach and stem insertion path is best described as a curved one, rather than the typical straight path used in other approaches. This curved insertion path also has benefits for other approaches since the broaches and stem can be kept away from the abductors, minimizing the potential injury to them. Shorter stem length makes this curved insertion path easier to perform. This is the first study to describe the effect that stem length has on its insertion path into the femoral canal. As expected, the physical portion of the study showed more variability than the computer generated portion. However, the physical and computer studies correlated well, with shorter stem lengths clearly allowing a more curved insertion path. The improvement tapered off in stem lengths below 63mm. This length correlates well with the other attempts at a shorter stem. This study provides quantitative data to help with shorter stem design and possible computer navigated insertion paths


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 134 - 134
1 Apr 2019
Adekanmbi I Ehteshami Z Hunt C Dressler M
Full Access

Introduction. In cementless THA the incidence of intraoperative fracture has been reported to be as high 28% [1]. To mitigate these surgical complications, investigators have explored vibro-acoustic techniques for identifying fracture [2–5]. These methods, however, must be simple, efficient, and robust as well as integrate with workflow and sterility. Early work suggests an energy-based method using inexpensive sensors can detect fracture and appears robust to variability in striking conditions [4–5]. The orthopaedic community is also considering powered impaction as another way to minimize the risk of fracture [6– 8], yet the authors are unaware of attempts to provide sensor feedback perhaps due to challenges from the noise and vibrations generated during powered impaction. Therefore, this study tests the hypothesis that vibration frequency analysis from an accelerometer mounted on a powered impactor coupled to a seated femoral broach can be used to distinguish between intact and fractured bone states. Methods. Two femoral Sawbones (Sawbones AB Europe, SKU 1121) were prepared using standard surgical technique up to a size 4 broach (Summit, Depuy Synthes). One sawbone remained intact, while a calcar fracture approximately 40mm in length was introduced into the other sawbone. Broaching was performed with a commercially available pneumatic broaching system (Woodpecker) for approximately 4 secs per test (40 impactions/sec) with hand-held support. Tests were repeated 3 times for fractured and intact groups as well as a ‘control’ condition with the broach handle in mid-air (ie not inserted into the sawbone). Two accelerometers (PCB M353B18) positioned on the femoral condyle and the Woodpecker impactor captured vibration data from bone-broach-impactor system (Fig1). Frequency analysis from impaction strikes were postprocessed (Labview). A spectrogram and area under FFT (AUFFT) [4] were analysed for comparisons between fractured and intact bone groups using a nested ANOVA. Results. Vibration frequency patterns between respective groups were best observed using an accelerometer positioned on the impaction device rather than on a sawbone (fig1). Qualitative assessment revealed that spectrograms showed no obvious difference for characteristic vibration frequencies between intact and fractured bone groups. A frequency signal at approximately 10kHz was absent for control impactions but present with bone impactions (Fig2). Quantitative assessment revealed AU-FFT was noticeably higher for intact bone groups than fractured bone groups for sampled impactions using a nested experimental design for statistics (p=0.11). Discussion. Our pilot study demonstrates that application of powered impaction combined with vibration frequency analysis has the potential to distinguish between an intact and fractured sawbone in a way that minimises instrumentation footprint and complexity of workflow in OR with a new generation of impaction device targeted at reducing and detecting bone fractures. Further investigation should validate these methods by evaluating the variation with sawbones and simulated bone fractures


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 15 - 15
1 Jan 2011
Boldt J
Full Access

Femoral stress shielding in cementless THA is a potential complication commonly observed in distally loading press-fit stems. This prospective study describes long-term femoral bone remodeling in cementless THA at a mean of 17 years (range: 15 to 20) in 208 consecutive fully HA-coated stems (Corail, DePuy Int. Ltd, Leeds, UK). All THA were performed by one group of surgeons between 1986 and 1991. The concept of surgical technique included impaction of metaphyseal bone utilizing bland femoral broaches until primary stability was achieved without distal press-fit. Radiographic evaluation revealed a total of five (2.4%) stems with periprosthetic osteolysis, which were associated with eccentric polyethylene wear. They were either revised or awaiting revision surgery. The remaining 97.6% stems revealed biologic load transfer in the metaphysis alone (52%) or in both metaphysis and diaphysis (48%). Stem survival of 97.6% after 15 to 20 years without stress shielding were considered to be related to: impaction of metaphyseal bone, bland broaches, HA coating, and unique prosthetic design


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 511 - 511
1 Oct 2010
Boldt J
Full Access

Femoral stress shielding in cementless THA is a potential complication commonly observed in distally loading press-fit stems. This prospective study describes long-term femoral bone remodeling in cementless THA at a mean of 17 years (range: 15 to 20) in 208 consecutive fully HA-coated stems (Corail, DePuy Int. Ltd, Leeds, UK). All THA were performed by one group of surgeons between 1986 and 1991. The concept of surgical technique included impaction of metaphyseal bone utilizing bland femoral broaches until primary stability was achieved without distal press-fit. Radiographic evaluation revealed a total of five (2.4%) stems with periprosthetic osteolysis, which were associated with eccentric polyethylene wear. They were either revised or awaiting revision surgery. The remaining 97.6% stems revealed biologic load transfer in the metaphysis alone (52%) or in both metaphysis and diaphysis (48%). Stem survival of 97.6% after 15 to 20 years without stress shielding were considered to be related to: impaction of metaphyseal bone, bland broaches, HA coating, and unique prosthetic design


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_II | Pages 302 - 302
1 May 2010
Boldt JG
Full Access

Femoral stress shielding in cementless THA is a potential complication commonly observed in distally loading press-fit stems. This prospective study describes long-term femoral bone remodeling in cementless THA at a mean of 17 years (range: 15 to 20) in 208 consecutive fully HA-coated stems (Corail, DePuy Int. Ltd, Leeds, UK). All THA were performed by one group of surgeons between 1986 and 1991. The concept of surgical technique included impaction of metaphyseal bone utilizing bland femoral broaches until primary stability was achieved without distal press-fit. Radiographic evaluation revealed a total of five (2.4%) stems with periprosthetic osteolysis, which were associated with eccentric polyethylene wear. They were either revised or awaiting revision surgery. The remaining 97.6% stems revealed biologic load transfer in the metaphysis alone (52%) or in both metaphysis and diaphysis (48%). Stem survival of 97.6% after 15 to 20 years without stress shielding were considered to be related to: impaction of metaphyseal bone, bland broaches, HA coating, and unique prosthetic design


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XLI | Pages 107 - 107
1 Sep 2012
Boldt J
Full Access

Femoral stress shielding in cementless THA is a potential complication commonly observed in cementless distally loading press-fit stems. Long-term metaphyseal fixation and proximal load transfer is desired. Is routine autologous metaphyseal bone impaction and proximal primary stability an answer to this goal?. This prospective study describes long-term femoral bone remodeling and load transfer in cementless THA at a mean of 17 years (range: 15 to 20 years) in 208 consecutive fully HA-coated stems (Corail). All primary THA were performed by one group of surgeons between 1986 and 1991. The concept of surgical technique included impaction of autologous metaphyseal bone using bland femoral broaches until primary stability was achieved without distal press-fit. Radiographic evaluation revealed a total of five (2.4%) stems with periprosthetic osteolysis, which were associated with eccentric polyethylene wear. They were either revised or awaiting revision. The remaining 97.6% stems revealed desired proximal load transfer in the metaphysis (52%) or in both metaphysis and diaphysis (48%). Distal stress shielding was not observed and was considered to be related to: impaction of metaphyseal bone, bland broaches, HA coating, and prosthetic design. Biological autologous bone impaction of the metaphysis provides both primary stem stability and successful longterm osteointegration with the Corail stem after 20 years. The surgical technique of proximal autologous bone impaction rather than extraction of cancellous bone material and the use of a fully HA coated stem without distal press-fit show encouraging longterm results in THA


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 463 - 463
1 Dec 2013
Ohmori Y Jingushi S Kawano T Itoman M
Full Access

Purpose:. In order to acquire good stability of an arthroplasty hip, the proper placement of the implants, which prevents impingement between the stem neck and the socket, is important. In general, the anteversion of the uncemented femoral stem depends on the relationship between the three-dimensional structure of the proximal femoral canal and the proximal stem geometry. The exact degree of the anteversion will be known just after broaching during the operation. If the stem anteversion could be forecasted, preoperative planning of the socket placement would be relatively easy. Furthermore, when a high degree of anteversion is forecasted, a special femoral stem to reduce it, such as a modular stem, could be prepared. However, we experienced that the preoperatively measured anteversion of the femoral neck using computer tomography (CT) was sometimes different from that of the stem measured during the operation. The purpose of this study was to investigate whether the preoperative measurement would be helpful to predict the stem anteversion by examining the relationship between the anteversion of the femoral neck and the stem. Patients and methods:. A total of 57 primary THAs by one senior surgeon from April 2011 until March 2012 were carried out. Two THAs using a modular stem and one for the hip after previous proximal femoral osteotomy were excluded. The remaining 54 THAs were examined. The used uncemented stems were designed for proximal metaphyseal fixation. CT scans, including the distal femoral condyles as well as the hips, were carried out in all cases preoperatively. The anteversion of the femoral neck was measured as the angle of the maximum longitudinal line of the cross section of the femoral neck to the line connecting the posterior surfaces of both of the distal femoral condyles (Fig. 1). The femoral neck anteversion was measured at three levels (Fig. 1). The stem anteversion was measured just after the femoral broaching during the THA. The relationship between the anteversion angles of the femoral neck and of the stem was examined by using a regression analysis. The institutional review board approved this study. Results:. The anteversion angles of the femoral neck varied widely when they were measured at all of the levels (Table 1). The anteversion angle of the femoral neck was not always identical to that of the stem. There were 32–46% of cases in which the difference between the stem anteversion and the femoral neck anteversion was within 5 degrees. There was a significant relationship between the anteversion of the stem and that of the femoral neck measured at all three levels (Fig. 2). When it was measured just below the femoral head, it was the closest to one, and the p-value was the lowest. Discusssion and Conclusions:. The anteversion of the uncemented stem could be calculated by using the formula to show the relationship between the stem anteversion and the femoral neck antevesion measured preoperatively. The values appeared to be sufficiently correct for making clinical decisions, although a prospective study may be necessary to confirm this


Orthopaedic Proceedings
Vol. 96-B, Issue SUPP_11 | Pages 139 - 139
1 Jul 2014
Ayers D Snyder B Porter A Walcott M Aubin M Drew J Greene M Bragdon C
Full Access

Summary Statement. In young, active patients cementless THR demonstrates excellent prosthetic stability by RSA and outstanding clinical outcomes at 5 years using a tapered titanium femoral stem, crosslinked polyethylene liners and either titanium or tantalum shells. Introduction. Early femoral implant stability is essential to long-term success in total hip replacement. Radiostereometric analysis (RSA) provides precise measurements of micromotion of the stem relative to the femur that are otherwise not detectable by routine radiographs. This study characterised micromotion of a tapered, cementless femoral stem and tantalum porous-coated vs. titanium acetabular shells in combination with highly cross-linked UHMWPE or conventional polyethylene liners using radiostereometric analysis (RSA) for 5 years following THR. Patients and Methods. This IRB-approved, prospective, double randomised, blinded study, involved 46 patients receiving a primary THR by a single surgeon. Each patient was randomised to receive a titanium (23) (Trilogy, Zimmer) or tantalum (23) (Modular Tantalum shell, Zimmer) uncemented hemispheric shell and either a highly-crosslinked or conventional polyethylene liner. Tantalum RSA markers were implanted in each patient. All patients had a Dorr A or B femoral canal and received a cementless, porous-coated titanium tapered stem (M/L Taper, Zimmer). All final femoral broaches were stable to rotational and longitudinal stress. RSA examinations, Harris Hip, UCLA, WOMAC, SF-12 scores were obtained at 10 days, 6 months, and annually through 5 years. Results. All patients demonstrated statistically significant improvement in Harris Hip, WOMAC, and SF-12 PCS scores post-operatively. Evaluation of polyethylene wear demonstrated that median penetration measurements were significantly greater in the conventional compared to the HXPLE liner cohorts at 1 year through 5 years follow-up (p<0.003). At 5 years, conventional liners showed 0.38 ± 0.05mm vertical wear whereas HXLPE liners showed 0.08 ± 0.02mm (p<0.003). Evaluation of the femoral stems demonstrated that the rate of subsidence was highest in the first 6 months (0.09mm/yr), with no other detectable motion through 5 years. Two outlying patients had significantly higher stem subsidence values at 6 months (0.7 mm and 1.0mm). One stem stabilised without further subsidence after 6 months (0.7mm), and the other stem stabilised at 1 year (1.5mm). Neither patient has clinical evidence of loosening. Evaluation of acetabular shells demonstrated less median vertical translation in tantalum than titanium shells at each time-point except at 3-years follow-up, however due to large standard errors, there was no significant difference between the two designs (p>0.05). These large standard errors were predominantly caused by two outliers, neither of which had clinical evidence of loosening. Discussion/Conclusion. In this RSA study of young THR patients, cementless tapered femoral stems, highly crosslinked polyethylene liners, and tantalum or titanium acetabular shells all demonstrated excellent performance through 5 years follow-up. Highly crosslinked polyethylene liners demonstrated significantly less wear than conventional liners. The femoral stem showed excellent stability through 5 years, with no clinical or radiologic episodes of failure. The small amount of micromotion seen is less than that previously reported for similar tapered, cementless stems and approaches the accuracy of RSA (0.05mm). Both acetabular shells demonstrated excellent stability with minimal micromotion at 5 years without significant differences in migration. All patients demonstrated significant clinical improvement in pain and function and additional RSA evaluation of these patients is planned


Bone & Joint Open
Vol. 5, Issue 3 | Pages 154 - 161
1 Mar 2024
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims

It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA.

Methods

In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 154 - 161
28 Mar 2023
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims

It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA.

Methods

In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound.


Bone & Joint Research
Vol. 11, Issue 3 | Pages 180 - 188
1 Mar 2022
Rajpura A Asle SG Ait Si Selmi T Board T

Aims

Hip arthroplasty aims to accurately recreate joint biomechanics. Considerable attention has been paid to vertical and horizontal offset, but femoral head centre in the anteroposterior (AP) plane has received little attention. This study investigates the accuracy of restoration of joint centre of rotation in the AP plane.

Methods

Postoperative CT scans of 40 patients who underwent unilateral uncemented total hip arthroplasty were analyzed. Anteroposterior offset (APO) and femoral anteversion were measured on both the operated and non-operated sides. Sagittal tilt of the femoral stem was also measured. APO measured on axial slices was defined as the perpendicular distance between a line drawn from the anterior most point of the proximal femur (anterior reference line) to the centre of the femoral head. The anterior reference line was made parallel to the posterior condylar axis of the knee to correct for rotation.


Bone & Joint 360
Vol. 3, Issue 1 | Pages 42 - 45
1 Feb 2014
Shah N Hodgkinson J

Hip replacement is a very successful operation and the outcome is usually excellent. There are recognised complications that seem increasingly to give rise to litigation. This paper briefly examines some common scenarios where litigation may be pursued against hip surgeons. With appropriate record keeping, consenting and surgical care, the claim can be successfully defended if not avoided. We hope this short summary will help to highlight some common pitfalls. There is extensive literature available for detailed study.


Bone & Joint 360
Vol. 4, Issue 5 | Pages 2 - 7
1 Oct 2015
Clark GW Wood DJ

The use of robotics in arthroplasty surgery is expanding rapidly as improvements in the technology evolve. This article examines current evidence to justify the usage of robotics, as well as the future potential in this emerging field.