Introduction. The
Introduction. Intramedullary lengthening devices have been in use in older children with closed /open growth plates with good success. This study aims to present the early experience of the
Introduction. Management of deformity involving limb length discrepancy (LLD) using intramedullary devices offers significant benefits to both patients and clinicians over traditional external fixation. Following the withdrawal of the PRECICE nail, the
At Sheffield Children's Hospital, treatment of leg length discrepancy is a common procedure. Historically, this has been done with external fixators. With the development in intramedullary technology, internal nails have become the preferred modality for long bone lengthening in the adolescent population. However, it is important to review whether this technology practically reduces the known challenges seen and if it brings any new issues. Therefore, the aim of this review is to retrospectively evaluate the therapeutic challenges of 16 fit-bone intramedullary femoral lengthening's at Sheffield Children's Hospital between 2021–2022. The international classification of function (ICF) framework was used to differentiate outcomes. The patient's therapy notes were retrospectively reviewed for themes around structural, activity and participation limitation. The findings were grouped for analysis and the main themes presented.Introduction
Materials & Methods
Introduction. Fully implantable distraction nails are frequently used for lengthening of the lower leg. What are the indications for humerus lengthening and which results can be expected?. Materials and Methods. The humerus as the best healing bone in the human body is suitable for lengthening with a nail as well but the indications are rare in comparison with the lower legs. Especially when driving a car or when working on a tablet length discrepancy of the arms of more than 4–5cm may cause severe hardening of the cervical muscles and induce chronical pain in the upper spine. Results. A distraction nail (FITBONE) was used in 5 cases for humerus lengthening. The nail was inserted in all cases from proximal. The mean age of the patients was 34 years. The mean lengthening amount was 58mm (55–100). In one case the system was exchanged to reach the desired length. There was no infection, no radial nerve irritation and no chronical shoulder pain. The system was removed in 4 cases in an average of 15 months the other nail will be removed soon as well. Conclusions. The preliminary results of our 5 cases demonstrate, that the
Shortness of an extremity due to different causes is an issue that may adversely affect human life functional and psychologically. In this study, in the light of previous studies, it is aimed to develop a new expandable intramedullary system, providing lengthening in order to remove previous problems and complications and to annihilate leg length discrepancies at present and future without second surgical intervention as far as possibble by lenghtening the intramedullary nail. To this end, a new electromechanically activated intramedullary nail has been designed and generated. The intramedullary nail was designed to perform extremity lengthening electro-mechanically. The 3D design of the system is performed with computer software and the rapid and metal prototype of the system has been produced. The intramedullary nail system is comprised of three main units; Mechanical transmission unit, Electronic unit, Lengthening unit. The nail system is designed to function both mechanically and electronically complying with the requirement. This also provides an advantage that if any one (mechanic or electronic) fails, the lengthening process can continue with the other. Compression tests are applied in order to evaluate the strength of the system. The deformation values of the parts are recorded and stress values of each parts were calculated. The new system needs only 300N loading for mechanical lengthening. When 800N is considered as average human weight, the implant must withstand minumum 2400N load. Considering the safety conditions, we applied 4000N load on the new system. At 4000N, the whole system shows only 1.465 mm deformation which is less than the gap between the two bone parts. Also, when the system is implanted inside the bone, the loads are distributed proportionally between the bone and the implant. So, except for extraordinary conditions, the newly developed system is highly rigid and safe. In each applied method, lots of complications whether general or method-specific are seen. When the methods like Albizzia, ISKD and
This study aims to enhance understanding of clinical and radiological consequences and involved mechanisms that led to corrosion of the Precice Stryde (Stryde) intramedullary lengthening nail in the post market surveillance era of the device. Between 2018 and 2021 more than 2,000 Stryde nails have been implanted worldwide. However, the outcome of treatment with the Stryde system is insufficiently reported. This is a retrospective single-centre study analyzing outcome of 57 consecutive lengthening procedures performed with the Stryde nail at the authors’ institution from February 2019 until November 2020. Macro- and microscopic metallographic analysis of four retrieved nails was conducted. To investigate observed corrosion at telescoping junction, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX) were performed.Aims
Methods
The June 2012 Children’s orthopaedics Roundup360 looks at; open reduction for DDH; growing rod instrumentation for scoliosis; acute patellar dislocation; management of the relapsed clubfoot; clubfoot in Iran; laughing gas and fracture manipulation; vascularised periosteal fibular grafting for nonunion; slipped upper femoral epiphysis; intramedullary leg lengthening and orthopaedic imaging and defensive medicine.