Advertisement for orthosearch.org.uk
Results 1 - 20 of 622
Results per page:
Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_12 | Pages 5 - 5
1 Oct 2019
Sculco PK Nocon AA Selemon NA Diane A Demartino AM Mayman DJ Sculco TP
Full Access

Introduction. The anatomic dual mobility (ADM) technology utilized a monoblock cobalt chromium acetabular component. However, design limitations conferred difficulties controlling orientation during component insertion and inability to confirm full implant seating; the solution resulted in the creation of the modular dual mobility (MDM). The modular implant combines a standard titanium acetabular component and a cobalt chromium liner insert. Due to the metal-on-metal interface on MDM implants, fretting and corrosion releasing metal ions like previous metal-on-metal THA implants, were a concern. This study prospectively reviewed metal ions (cobalt, chromium and titanium) on patients who were at least 1 year post MDM implantation and compared them to patients with an ADM implant and evaluated radiographic seating of the components. Methods. All patients with ADM and MDM implants underwent evaluation of metal ions (cobalt, chromium and titanium) at their one year follow-up appointment. Radiographic evaluation for acetabular polar gaps was performed. Elevated metal ions were determined using standard laboratory ranges. Differences in baseline demographics were assessed using the Mann Whitney-U test and Fishers's exact test. Differences in metal ions and implant type were compared using the Fisher's exact tests. Results. Fifty consecutive patients (25 ADM and 25 MDM were included in the study. All patients in the ADM group were primary THR and all in the MDM group were revision THR. Mean age and BMI were 73 (+/−10) and 26 (+/−4) respectively. A majority of the participants were female (72%), overall mean length of implantation was 1.2 years. We found no difference in metal ion elevation between groups at a minimum of one year post implantation (cobalt, p=1.0, chromium, p=0.49; titanium p=1.0). Within the MDM and ADM cohorts, there were an equal number of patients with mildly elevated cobalt (n=6), as well as mildly elevated titanium (n=1). The ADM cohort had more patients with increased chromium when compared to the MDM cohort (ADM=1 vs MDM=0), but did not reach significance. There was one ADM patient with significantly elevated levels of cobalt and chromium probably related to prior spine fusion with dissimilar metal fixation. When reviewed as raw values, there was a difference in mean chromium levels between ADM and MDM cohorts (ADM=1.4 (+/− 2.5) vs MDM=1.2 (+/− 1.7), p=0.03; no other significant differences were found. An additional 32 ADM have been evaluated recently without elevation in cobalt or chromium levels. Of the total 55 ADM patients 4 had a 1mm polar gaps which filled in at 6–23 months postoperative. There were no polar gaps in the MDM series and one malseated liner. Conclusion. There were no significant differences in metal ion elevation minimum one year post implantation between primary ADM and revision MDM cohorts. This is encouraging based on the titanium/cobalt chrome interface in the MDM implant. Uncommon dome gaps in the monoblock ADM is not a clinical problem. For any tables or figures, please contact the authors directly


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_1 | Pages 56 - 56
1 Jan 2016
Bruni D Marko T Gagliardi M Bignozzi S Zaffagnini S Akkawi I Colle F Marcacci M
Full Access

Introduction

The purpose of this study was to examine whether three types of mobile-bearing PCL sacrificing TKA could restore the native knee translation and rotation. The primary hypothesis was that there are differences in knee kinematics and laxity between three different cruciate-substituting TKA designs: 1 with post-cam mechanism, 2 post-cam mechanism based on an inter-condylar ‘third condyle’ concept, 3 anterior stabilized with deep-dished highly congruent tibial insert; specifically, showing different femoral external rotation with flexion, different femoral translation with flexion and different laxity under stress test. The secondary hypothesis was that there is different clinical outcome between the three TKA designs at 2 years follow-up.

Methods

We recruited 3 cohorts consisting of 30 patients each divided according 3 different TKA designs. All patients were operated with navigated procedure. During surgery preoperative and postoperative kinematics were recorded, in terms of femoral antero-posterior translation and tibial rotation during knee flexion, as also preoperative and postoperative at 2 years follow-up clinical scores have been acquired.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 135 - 135
11 Apr 2023
du Moulin W Bourne M Diamond L Konrath J Vertullo C Lloyd D Saxby D
Full Access

Following anterior cruciate ligament reconstruction (ACLR) using a semitendinosus (ST) autograft measures such as length, cross-sectional area, and volume may not fully describe the effects of tendon harvest on muscle morphology as these discrete measures cannot characterize three-dimensional muscle shape. This study aimed to determine between-limb ST shape similarity and regional morphology in individuals with a unilateral history of ACLR using a ST graft, and healthy controls.

A secondary analysis of magnetic resonance imaging was undertaken from 18 individuals with unilateral history of ST ACLR and 18 healthy controls. ST muscles were manually segmented, and shape similarity were assessed between limbs and groups using Jaccard index (0-1) and Hausdorff distance (mm). ST length (cm), peak cross-sectional area (CSA) (cm2), and volume (cm3) was compared between surgically reconstructed and uninjured contralateral limbs, and between the left and right limbs of control participants with no history of injury. Cohen's d was reported as a measure of effect size.

Compared to healthy controls, the ACLR group had significantly (p<0.001, d= −2.33) lower bilateral ST shape similarity. Furthermore, the deviation in muscle shape was significantly (p<0.001, d= 2.12) greater in the ACLR group. Within the ACLR group, maximum Hausdorff distance indicated ST from the ACLR limb deviated (23.1±8.68 mm) from the shape of the healthy contralateral ST, this was observed particularly within the distal region of the muscle. Compared to the uninjured contralateral limb and healthy controls, deficits in peak cross-sectional area and volume in ACLR group were largest in proximal (p<0.001, d= −2.52 to −1.28) and middle (p<0.001, d= −1.81 to −1.04) regions.

Findings highlight morphological features in distal ST not identified by traditional discrete morphology measures. ST shape was most different in the distal region of the muscle, despite deficits in CSA and volume being most pronounced in proximal and middle regions. ST shape following ACLR may affect force transmission and distribution within the hamstrings and contribute to persistent deficits in knee flexor and internal rotator strength.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 71 - 71
11 Apr 2023
Pelegrinelli A Kowalski E Ryan N Dervin G Moura F Lamontagne M
Full Access

The study compared thigh-shank and shank-foot coordination during gait before and after total knee arthroplasty (TKA) with controls (CTRL).

Twenty-seven patients (male=15/female=12; age=63.2±6.9 years) were evaluated one month prior to and twelve months after surgery, and compared to 27 controls (male=14/female=13; age=62.2±4.3). The participants were outfitted with a full-body marker set. Gait speed (normalized by leg length) was calculated. The time series of the thigh, shank, and foot orientation in relation to the laboratory coordinate system were extracted. The coordination between the thigh-shank and shank-foot in the sagittal plane were calculated using a vector coding technique. The coupling angles were categorized into four coordination patterns. The stance phase was divided into thirds: early, mid, and late stance. The frequency of each pattern and gait speed were compared using a one-way ANOVA with a post-hoc Bonferroni correction.

Walking speed and shank-foot coordination showed no differences between the groups. The thigh-shank showed differences. The pre-TKA group showed a more in-phase pattern compared to the CTRL group during early-stance. During mid-stance, the pre- and post-TKA presented a more in-phase pattern compared to the CTRL group. Regarding shank-foot coordination, the groups presented an in-phase and shank pattern, with more shank phase during mid-stance and more in-phase during late-stance.

The pre-TKA group showed greater differences than the post-TKA compared to the controls. The more in-phase pattern in the pre- and post-TKA groups could relate to a reduced capacity for the thigh that leads the movement. During mid-stance in normal gait, the knee is extending, where the thigh and shank movements are in opposite directions. The in-phase results in the TKA groups indicate knee stiffness during the stance phase, which may relate to a muscular deficit or a gait strategy to reduce joint stress.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_9 | Pages 9 - 9
1 Jun 2021
Greene A Verstraete M Roche C Conditt M Youderian A Parsons M Jones R Flurin P Wright T Zuckerman J
Full Access

INTRODUCTION. Determining proper joint tension in reverse total shoulder arthroplasty (rTSA) can be a challenging task for shoulder surgeons. Often, this is a subjective metric learned by feel during fellowship training with no real quantitative measures of what proper tension encompasses. Tension too high can potentially lead to scapular stress fractures and limitation of range of motion (ROM), whereas tension too low may lead to instability. New technologies that detect joint load intraoperatively create the opportunity to observe rTSA joint reaction forces in a clinical setting for the first time. The purpose of this study was to observe the differences in rTSA loads in cases that utilized two different humeral liner sizes. METHODS. Ten different surgeons performed a total of 37 rTSA cases with the same implant system. During the procedure, each surgeon reconstructed the rTSA implants to his or her own preferred tension. A wireless load sensing humeral liner trial (VERASENSE for Equinoxe, OrthoSensor, Dania Beach, FL) was used in lieu of a traditional plastic humeral liner trial to provide real-time load data to the operating surgeon during the procedure. Two humeral liner trial sizes were offered in 38mm and 42mm curvatures and were selected each case based on surgeon preference. To ensure consistent measurements between surgeons, a standardized ROM assessment consisting of four dynamic maneuvers (maximum internal to external rotation at 0°, 45°, and 90° of abduction, and a maximum flexion/extension maneuver) and three static maneuvers (arm overhead, across the body, and behind the back) was completed in each case. Deidentified load data in lbf was collected and sorted based on which size liner was selected. Differences in means for minimum and maximum load values for the four dynamic maneuvers and differences in means for the three static maneuvers were calculated using 2-tailed unpaired t-tests. RESULTS. No significant differences were observed for the flexion/extension maneuver between the 38mm and 42mm liner sizes, but a significant difference was observed for every internal/external rotation assessment at 0°, 45°, and 90° of abduction. No significant differences were observed for the across the body and overhead maneuvers, but a significant difference was observed for the behind the back maneuver (p = 0.015). Standard deviations were pronounced across all maneuvers. CONCLUSION. This study observed significant differences in intraoperative load values in rTSA when comparing different humeral liner sizes. Limitations of this study include the small sample sizes and large standard deviations observed, as well as comparing across multiple patients and multiple surgeons. Area for future work includes comparing load values with postoperative functional results and complication risks for short, midterm, and long-term outcomes in efforts to find the optimal load range for a given patient


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 40 - 40
17 Apr 2023
Saiz A Kong S Bautista B Kelley J Haffner M Lee M
Full Access

With an aging population and increase in total knee arthroplasty, periprosthetic distal femur fractures (PDFFs) have increased. The differences between these fractures and native distal femur fractures (NDFF) have not been comprehensively investigated. The purpose of this study was to compare the demographic, fracture, and treatment details of PDFFs compared to NDFFs.

A retrospective study of patients ≥ 18 years old who underwent surgical treatment for either a NDFF or a PDFF from 2010 to 2020 at a level 1 trauma center was performed. Demographics, AO/OTA fracture classification, quality of reduction, fixation constructs, and unplanned revision reoperation were compared between PDFF patients and NDFF patients using t-test and Fisher's exact test. 209 patients were identified with 70 patients having a PDFF and 139 patients having a NDFF. Of note, 48% of NDFF had a concomitant fracture of the ipsilateral knee (14%) or tibial plateau (15%). The most common AO/OTA classification for PDFFs was 33A3.3 (71%). NDFFs had two main AO/OTA classifications of 33C2.2 (28%) or 33A3.2. (25%). When controlling for patient age, bone quality, fracture classification, and fixation, the PDFF group had increased revision reoperation rate compared to NDFF (P < 0.05).

PDFFs tend to occur in elderly patients with low bone quality, have complete metaphyseal comminution, and be isolated; whereas, NDFF tend to occur in younger patients, have less metaphyseal comminution, and be associated with other fractures. When controlling for variables, PDFF are at increased risk of unplanned revision reoperation. Surgeons should be aware of these increased risks in PDFFs and future research should focus on these unique fracture characteristics to improve outcomes.


Bone & Joint Research
Vol. 10, Issue 1 | Pages 85 - 95
27 Jan 2021
Akhbari P Jaggard MK Boulangé CL Vaghela U Graça G Bhattacharya R Lindon JC Williams HRT Gupte CM

Aims

The diagnosis of joint infections is an inexact science using combinations of blood inflammatory markers and microscopy, culture, and sensitivity of synovial fluid (SF). There is potential for small molecule metabolites in infected SF to act as infection markers that could improve accuracy and speed of detection. The objective of this study was to use nuclear magnetic resonance (NMR) spectroscopy to identify small molecule differences between infected and noninfected human SF.

Methods

In all, 16 SF samples (eight infected native and prosthetic joints plus eight noninfected joints requiring arthroplasty for end-stage osteoarthritis) were collected from patients. NMR spectroscopy was used to analyze the metabolites present in each sample. Principal component analysis and univariate statistical analysis were undertaken to investigate metabolic differences between the two groups.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 20 - 20
1 Dec 2022
O'Connor K Zwicker J Chhina H Cooper A
Full Access

A huge commitment is required from patients and families who undergo a limb reconstruction procedure using the hexapod frame. This includes turning the struts on the frame, pin site care and intensive rehabilitation. Montpetit et al (2009) discovered that function, participation, engagement in regular activities of daily living is severely impacted during the hexapod lengthening period. Due to the long duration and burden for families, it is imperative that healthcare professionals understand the impact that the hexapod frame has on functional abilities and health related quality of life (HRQL).

This project involved a retrospective review of prospectively collected data on function and HRQL during two periods of time: (1) when the hexapod frame is applied on the child's lower extremity and (2) when the lengthening phase is completed, and the hexapod frame is removed. Data from 38 children (mean age: 12 years SD 3.8) who completed lower extremity reconstruction using the hexapod frame and completed either or both the Pediatric Quality of Life Inventory 4.0 Generic Core Scale (PedsQL) and Pediatric Outcomes data Collection Instrument (PODCI) was included. Analysis included, standardized response means, the non-parametric Wilcoxon test and effect size calculation.

A Wilcoxon signed rank test for those children who completed pre and post frame PODCI’;s revealed those scores were significantly greater once the hexapod frame was removed (Md=85.10, n=10) compared to during (Md=66.50, n=10) with a large effect size, r= 1.45. Similar, the PedsQL scores improved post frame removal (Md= 66.30, n=10) compared to during treatment (Md = 53.34, n=10), with a medium size effect, r= 0.62. All subtests improved once the frame was removed.

This study provides essential insights into the burden of the hexapod frame for children and provides valuable information for all allied healthcare professionals targeted interventions for health domains. This study shows that children's function improves once the hexapod frame is removed. However, this study highlights the importance for all healthcare professional to address health domains for the duration of the hexapod procedure where the child scored lower e.g. sports and physical function, pain and comfort, happiness from the PODCI. The PedsQL identified lower mean scores in physical and emotional function.


Bone & Joint Open
Vol. 5, Issue 3 | Pages 154 - 161
1 Mar 2024
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims

It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA.

Methods

In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound.


Bone & Joint Open
Vol. 4, Issue 3 | Pages 154 - 161
28 Mar 2023
Homma Y Zhuang X Watari T Hayashi K Baba T Kamath A Ishijima M

Aims

It is important to analyze objectively the hammering sound in cup press-fit technique in total hip arthroplasty (THA) in order to better understand the change of the sound during impaction. We hypothesized that a specific characteristic would present in a hammering sound with successful fixation. We designed the study to quantitatively investigate the acoustic characteristics during cementless cup impaction in THA.

Methods

In 52 THAs performed between November 2018 and April 2022, the acoustic parameters of the hammering sound of 224 impacts of successful press-fit fixation, and 55 impacts of unsuccessful press-fit fixation, were analyzed. The successful fixation was defined if the following two criteria were met: 1) intraoperatively, the stability of the cup was retained after manual application of the torque test; and 2) at one month postoperatively, the cup showed no translation on radiograph. Each hammering sound was converted to sound pressures in 24 frequency bands by fast Fourier transform analysis. Basic patient characteristics were assessed as potential contributors to the hammering sound.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 51 - 51
10 Feb 2023
Gleeson C Zhu M Frampton C Young S Poutawera V Mutu-Grigg J
Full Access

The New Zealand Joint Registry (NZJR) was established in 1999. However, ethnicity data was not recorded by prioritisation in line with Ministry of Health (MoH) recommendations. Recently, cross-referencing with MoH updated ethnicity data for all 326,150 entries in the NZJR database. The objective of this national level, population study was to identify any ethnic disparities in access and outcome for Māori for primary total hip (THA) and knee arthroplasty (TKA) for Osteoarthritis.

The utilisation rate for THA and TKAs were calculated for the Māori and NZ European population from all data in the NZJR and Census data in 2001, 2006, 2013 and 2018. Utilisation rate was reported separately for four age groups (<55, 55-64, 65-74, >75) over four time periods (1999-2004, 2005-2009, 2010-2014, 2015-2020). Revision rate, 6 months and 5-year Oxford scores were adjusted for age, sex and BMI, then compared between groups.

In every age group and at all but one time point, significant under-utilisation of TKA was observed in Māori. For THAs, Māori had similar utilisation rates in the <55 and 55-64 age groups, but significantly lower utilisation rates in all other age groups.

When adjusted for age, sex and BMI, no significant differences in revision rates were observed between Māori and NZ Europeans for THAs (HR 0.939, P 0.417) or TKAs (HR 1.129, P 0.149). Adjusted 6 months and 5-year Oxford scores were significantly higher in NZ Europeans, however, the maximum difference was less than 3 points and is unlikely to be clinically significant.

Despite the same risk of being diagnosed with osteoarthritis, Māori are less likely to undergo THA and TKA. There are no clinically significant differences in outcomes post arthroplasty between Māori and NZ Europeans. Further research is required to investigate causes for lower utilisation in Māori.


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_12 | Pages 27 - 27
1 Nov 2015
Berber R Khoo M Carrington R Miles J Skinner J Hart A
Full Access

Introduction. Uncertainties in the management of patients with MOM hip implants continue to be a problem for all surgeons. Guidelines vary and do not fully define or quantify thresholds. We aimed to assess the differences in decision-making amongst an international community of six specialist orthopaedic institutions. Methods. Five international tertiary referral orthopaedic units (one UK, two USA, and two European) were invited to participate. Each unit organised an MDT panel consisting of 2 or more hip surgeons and a musculoskeletal radiologist. All units discussed the same 10 patients. A full clinical dataset was provided including blood test and all imaging. Differences in the interpretation of findings, management decision and rationale for decisions were compared between institutions. Results. Asymptomatic patients with metal ions below 7ppb and intra-articular synovitis were collectively treated with monitoring and repeat ion measurement. Symptomatic patients with similar findings were recommended revision surgery by all units. Raised metal ions and a cystic pseudotumour on imaging that is palpable clinically was also consistently recommended revision surgery. Moderate symptoms (OHS 30), 2B pseudotumour, and moderate metal ions (cobalt 5.5ppb) were seen as an indication for revision in 5 units, however the reverse is seen if the patient had several co-morbidities. Further to this, rising blood metal ions (6 to 7.5ppb) was recommended surgery by 4 units, and watchful waiting in 2 units. Rising blood metal ion levels (6ppb to 10ppb) and a small fluid collection on MRI in asymptomatic patients was recommended clinical review and repeat metal ions by 3 units, repeat MRI by 1 unit and revision for suboptimal implant position by the remaining 2 units. Conclusion. Moderate symptoms, blood metal ions and cystic pseudotumours led to inconsistent agreement between institutions. Coordinated international guidance and MDT panel discussions are recommended to improve consensus in decision-making


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_10 | Pages 16 - 16
1 Jun 2023
Wright J Messner J McMahon S Johnson L Foster P Fernandes J Chhina H Klassen A Cooper A
Full Access

Introduction

LIMB-Q Kids is a new patient-reported outcome measure (PROM) for children with Lower limb differences (LLDs). The objective is to conduct an international field test study.

Materials & Methods

A mixed method multiphase approach was used to develop LIMB-Q Kids. In phase one, a systematic review was conducted to identify concepts from existing PROMs used in research with children with LLDs. A preliminary conceptual framework derived from the systematic review informed an international qualitative study. The data from qualitative interviews were used to form the LIMB-Q Kids, which was further refined through multiple rounds of cognitive debriefing interviews with children. Input was obtained from parents and healthcare professionals from Australia, Canada, Ethiopia, India, UK, and the USA. LIMB-Q Kids was translated and culturally adapted into multiple languages.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 52 - 52
17 Apr 2023
Abram S Sabah S Alvand A Price A
Full Access

Revision knee arthroplasty is a complex procedure with the number and cost of knee revision procedures performed per year expected to rise. Few studies have examined adverse events following revision arthroplasty.

The objective of this study was to determine rates of serious adverse events in patients undergoing revision knee arthroplasty with consideration of the indication for revision (urgent versus elective indications) and to compare these with primary arthroplasty and re-revision arthroplasty.

Patients undergoing primary knee arthroplasty were identified in the UK Hospital Episode Statistics. Subsequent revision and re-revision arthroplasty procedures in the same patients and same knee were identified. The primary outcome was 90-day mortality and a logistic regression model was used to investigate factors associated with 90-day mortality and secondary adverse outcomes including infection (undergoing surgery), pulmonary embolism, myocardial infarction, stroke. Urgent indications for revision arthroplasty were defined as infection or fracture, and all other indications were included in the elective indications cohort.

939,021 primary knee arthroplasty cases were included of which 40,854 underwent subsequent revision arthroplasty, and 9,100 underwent re-revision arthroplasty. Revision surgery for elective indications was associated with a 90-day rate of mortality of 0.44% (135/30,826; 95% CI 0.37-0.52) which was comparable to primary knee arthroplasty (0.46%; 4,292/939,021; 95% CI 0.44-0.47). Revision arthroplasty for infection, however, was associated with a much higher mortality of 2.04% (184/9037; 95% CI 1.75-2.35; odds ratio [OR] 3.54; 95% CI 2.81-4.46), as was revision for periprosthetic fracture at 5.25% (52/991; 95% CI 3.94-6.82; OR 6.23; 95% CI 4.39-8.85). Higher rates of pulmonary embolism, myocardial infarction, and stroke were also observed in the infection and fracture cohort.

These findings highlight the burden of complications associated with revision knee arthroplasty. They will inform shared decision-making for patients considering revision knee arthroplasty for elective indications. Patients presenting with infection of a knee arthroplasty or a periprosthetic fracture are at very high risk of adverse events. It is important that acute hospital services and tertiary referral centres caring for these patients are appropriately supported to ensure appropriate urgency and an anticipation for increased care requirements.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_13 | Pages 92 - 92
1 Dec 2022
Gazendam A Schneider P Busse J Bhandari M Ghert M
Full Access

Functional outcomes are commonly reported in studies of musculoskeletal oncology patients undergoing limb salvage surgery; however, interpretation requires knowledge of the smallest amount of improvement that is important to patients – the minimally important difference (MID). We established the MIDs for the Musculoskeletal Tumor Society Rating Scale (MSTS) and Toronto Extremity Salvage Score (TESS) in patients with bone tumors undergoing lower limb salvage surgery.

This study was a secondary analysis of the recently completed PARITY (Prophylactic Antibiotic Regimens in Tumor Surgery) study. This data was used to calculate: (1) the anchor-based MIDs using an overall function scale and a receiver operating curve analysis, and (2) the distribution-based MIDs based on one-half of the standard deviation of the change scores from baseline to 12-month follow-up, for both the MSTS and TESS.

There were 591 patients available for analysis. The Pearson correlation coefficients for the association between changes in MSTS and TESS scores and changes in the external anchor scores were 0.71 and 0.57, indicating “high” and “moderate” correlation. Anchor-based MIDs were 12 points and 11 points for the MSTS and TESS, respectively. Distribution-based calculations yielded MIDs of 16-17 points for the MSTS and 14 points for the TESS.

The current study proposes MID scores for both the MSTS and TESS outcome measures based on 591 patients with bone tumors undergoing lower extremity endoprosthetic reconstruction. These thresholds will optimize interpretation of the magnitude of treatment effects, which will enable shared decision-making with patients in trading off desirable and undesirable outcomes of alternative management strategies. We recommend anchor-based MIDs as they are grounded in changes in functional status that are meaningful to patients.


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_2 | Pages 55 - 55
1 Mar 2021
Dandridge O Garner A van Arkel R Amis A Cobb J
Full Access

Abstract

Objectives

The need for gender specific knee arthroplasty is debated. This research aimed to establish whether gender differences in patellar tendon moment arm (PTMA), a composite measure that characterises function of both the patellofemoral and tibiofemoral joints, are a consequence of knee size or other variation.

Methods

PTMA about the instantaneous helical axis was calculated from positional data acquired using optical tracking. First, data post-processing was optimised, comparing four smoothing techniques (raw, Butterworth filtered, generalised cross-validation cubic spline interpolated and combined filtered/interpolated) using a fabricated knee. Then PTMA was measured during open-chain extension for N=24 (11 female) fresh-frozen cadaveric knees, with physiologically based loading and extension rates (420°/s) applied. Gender differences in PTMA were assessed before and after accounting for knee size with epicondylar width.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_13 | Pages 40 - 40
7 Aug 2023
Rahman A Strickland L Pandit H Jenkinson C Murray D
Full Access

Abstract

Background

Daycase pathways which aim to discharge patients the same day following Unicompartmental Knee Replacement have been introduced in some centres, though most continue with Standard pathways. While Daycase pathways have cost savings, recovery data comparing pathways is limited. This study aims to compare patient-reported early recovery between Daycase and Standard pathways following UKR.

Method

This study was carried out in two centres that originally used the same Standard recovery pathway for UKR. In one centre, the Standard pathway was modified into a Daycase pathway. 26 Daycase-Outpatient, 11 Daycase-Inpatient, and 18 Standard patients were recruited. Patients completed the Oxford Arthroplasty Early Recovery Score (OARS) and SF-36 (Acute) measure between Days 1–42.


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_7 | Pages 34 - 34
1 Jul 2022
Abram S Sabah S Alvand A Price A
Full Access

Abstract

Introduction

The objective of this study was to determine rates of serious adverse events in patients undergoing revision knee arthroplasty with consideration of the indication for revision and compare these with primary knee arthroplasty.

Methodology

Primary and revision arthroplasty procedures were identified in the national Hospital Episode Statistics and were linked by patient and side. A logistic regression model was used to investigate factors associated with 90-day mortality (primary outcome) and secondary serious adverse outcomes. Urgent indications for revision arthroplasty were defined as infection or fracture; other indications (e.g. loosening, instability, wear) were included in the elective cohort.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 16 - 16
17 Apr 2023
Hornestam J Miller B Carsen S Benoit D
Full Access

To investigate differences in the drop vertical jump height in female adolescents with an ACL injury and healthy controls and the contribution of each limb in this task. Forty female adolescents with an ACL injury (ACLi, 15.2 ± 1.4 yrs, 164.6 ± 6.0 cm, 63.1 ± 10.0 kg) and thirty-nine uninjured (CON, 13.2 ± 1.7 yrs, 161.7 ± 8.0 cm, 50.6 ± 11.0 kg) were included in this study. A 10-camera infrared motion analysis system (Vicon, Nexus, Oxford, UK) tracked pelvis, thigh, shank, and foot kinematics at 200Hz, while the participants performed 3 trials of double-legged drop vertical jumps (DVJ) on two force plates (Bertec Corp., Columbus, USA) sampled at 2000Hz.The maximum jump height normalised by dominant leg length was compared between groups using independent samples t-test. The maximum vertical ground reaction force (GRFz) and sagittal ankle, knee and hip velocities before take-off were compared between limbs in both groups, using paired samples t-test. The normalised jump height was 11% lower in the ACLi than in the CON (MD=0.04 cm, p=0.020). In the ACLi, the maximum GRFz (MD=46.17N) and the maximum velocities of ankle plantar flexion (MD=79.83°/s), knee extension (MD=85.80°/s), and hip extension (MD=36.08°/s) were greater in the non-injured limb, compared to the injured limb. No differences between limbs were found in the CON.

ACL injured female adolescents jump lower than the healthy controls and have greater contribution of their non-injured limb, compared to their injured limb, in the DVJ task. Clinicians should investigate differences in the contribution between limbs during double-legged drop vertical jump when assessing patients with an ACL injury, as this could help identify asymmetries, and potentially improve treatment, criteria used to clear athletes to sport, and re-injury prevention.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 593 - 593
1 Nov 2011
Nault M Parent S Roy-Beaudry M de Guise JA Labelle H
Full Access

Purpose: Prediction of progression is actually impossible in adolescent idiopathic scoliosis (AIS). Potential risk factor to consider at first visit might be morphologic parameters of the spine. The objective of this study was to compare 3D morphologic parameters of the spine in a non evolutive an in an evolutive group of AIS. Method: A retrospective cohort study was done. Two groups were recruited with sample size based on a difference of 5 degrees for rotation parameters. First group were all surgical patients (n=19) and second group non evolutive patient (n=18). Inclusion criteria were. Risser sign of 0 or 1. Cobb angle between 11 and 40 degrees. AP and lateral radiograph available. Exclusion criteria were. limb length discrepancy. syndromic or congenital scoliosis. All spines were reconstructed in 3D with AP and lateral radiographs of the first visit and measurements were performed on the reconstruction. There were 4 categories of measurements done: Cobb angle, wedging, rotation, slenderness. Student t test were performed. Results: There was no statistical difference between the two groups for Cobb angle in maximal plane, for lordosis and kyphosis. Differences were found for wedging of the apical disk in 3D plane (S=5,4° vs NE= 0,7° with p=0,04). For coronal orientation of the apex (S=7,8° vs NE=0,1° with p=0,01). For axial orientation of inferior junctional vertebrae (S=1,9° vs 0,1° with p=0,007). For torsion (S=−4,1° vs NE= – 1,2° with p=0,03). For ratio between height and width of T6 (S=51% vs NE=53,6% with p=0,04). Conclusion: This study give for the first time some 3D morphologic parameters that could be use in the prediction of AIS. Some limitations exist such as the small sample size and the low level of significance. In the future those parameters will be used in the development of a prediction model base on those keys parameters that will confirm the actual findings