Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_II | Pages 337 - 337
1 May 2009
Wainwright C Jones DG King R
Full Access

The Morscher press fit acetabular component is a monobloc cup with the polyethylene bonded directly to a titanium mesh shell. There is little published data on the longevity of the Morscher cup apart from the designer’s series. It has been quite widely used in New Zealand since its introduction in 1993. The aim of this retrospective study was to provide an independent mid-term audit of the results of this cup in the New Zealand population. A retrospective review was undertaken of all Morscher cups implanted at Dunedin Public Hospital or Mercy Hospital by 5 orthopaedic surgeons between 1994 and 1998 with a minimum follow-up of seven years. Clinical and radiological survey was performed with standardised scoring systems. A new method for measuring linear cup wear was developed due to the unusual geometry of the Morscher cup. 136 hips were replaced in 121 patients during the study period 101 were performed in private and 35 in public. Our follow up ranged from 7 to 11 years (mean 8.69). There were 73 males (85 hips) and 48 females (51 hips). The average age of the patients was 57.5yrs (SO 24.97). Pre operatively the mean Merle d’Aubigne score was 9.4 (SO 4.02) and post operatively it was 17.4 (SO 1.58 (p< 0.0001). There were 2 early revisions: one at 3 days for instability post-operatively and one for an unrecognised intra-operative femoral fracture. One hip required a two stage revision for deep infection at 3 years. Two hips have been revised for polyethylene wear and osteolysis at 7 yrs and 9 yrs and one hip required bone grafting of a large acetabular osteolytic lesion with retention of the cup. A further 4 patients have significant osteolytic defects and 2 have minor osteolytic lesions. Wear measurements in the unrevised hips have shown a mean linear wear rate of 0.079mm/yr (range 0.000 to 0.222mm). 33% of these hips have a wear rate of > 0.1 mm/yr and 25% have a wear rate of < 0.05mm/yr. We have found excellent clinical results with the use of the Morscher cup in this relatively young and active cohort. A small group of patients, however, have shown higher wear rates or osteolysis, and we emphasise the importance of continuing radiological review


Bone & Joint Research
Vol. 9, Issue 6 | Pages 272 - 278
1 Jun 2020
Tapasvi S Shekhar A Patil S Pandit H

Aims

The mobile bearing Oxford unicompartmental knee arthroplasty (OUKA) is recommended to be performed with the leg in the hanging leg (HL) position, and the thigh placed in a stirrup. This comparative cadaveric study assesses implant positioning and intraoperative kinematics of OUKA implanted either in the HL position or in the supine leg (SL) position.

Methods

A total of 16 fresh-frozen knees in eight human cadavers, without macroscopic anatomical defects, were selected. The knees from each cadaver were randomized to have the OUKA implanted in the HL or SL position.


Bone & Joint 360
Vol. 7, Issue 1 | Pages 27 - 30
1 Feb 2018


Bone & Joint 360
Vol. 7, Issue 4 | Pages 33 - 36
1 Aug 2018


The Bone & Joint Journal
Vol. 98-B, Issue 10_Supple_B | Pages 34 - 40
1 Oct 2016
Emerson RH Alnachoukati O Barrington J Ennin K

Aims

Approved by the Food and Drug Administration in 2004, the Phase III Oxford Medial Partial Knee is used to treat anteromedial osteoarthritis (AMOA) in patients with an intact anterior cruciate ligament. This unicompartmental knee arthroplasty (UKA) is relatively new in the United States, and therefore long-term American results are lacking.

Patients and Methods

This is a single surgeon, retrospective study based on prospectively collected data, analysing a consecutive series of primary UKAs using the Phase III mobile-bearing Oxford Knee and Phase III instrumentation.

Between July 2004 and December 2006, the senior author (RHE) carried out a medial UKA in 173 patients (213 knees) for anteromedial osteoarthritis or avascular necrosis (AVN).

A total of 95 patients were men and 78 were women. Their mean age at surgery was 67 years (38 to 89) and mean body mass index 29.87 kg/m2 (17 to 62).

The mean follow-up was ten years (4 to 11).


Bone & Joint 360
Vol. 6, Issue 6 | Pages 31 - 33
1 Dec 2017


Bone & Joint 360
Vol. 6, Issue 6 | Pages 25 - 28
1 Dec 2017


Bone & Joint 360
Vol. 2, Issue 5 | Pages 19 - 21
1 Oct 2013

The October 2013 Knee Roundup360 looks at: Make it easy, release the MCL; Do patients remember clinical information in day surgery?; Osteoarthritis and arthroscopy?; How best to double your bundles; When to operate for infection; Cementless unicompartment knee replacement?; Tibial tubercle-trochlear groove confusion; Tarts, cherries and osteoarthritis


Bone & Joint 360
Vol. 2, Issue 2 | Pages 12 - 15
1 Apr 2013

The April 2013 Knee Roundup360 looks at: graft tension and outcome; chondrocytes at the midterm; pre-operative deformity and failure; the designer effect; whether chondroitin sulphate really does work; whether ACL reconstruction is really required; analgesia after TKR; and degenerative meniscus.