Advertisement for orthosearch.org.uk
Results 1 - 20 of 96
Results per page:
Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_II | Pages 127 - 128
1 Feb 2003
Meggitt B Dunn A
Full Access

This paper presents the first report of a prospective study to assess the outcome of using coregistration localisation and selective arthrodesis in chronic midfoot degenerative arthritis. In a previous report from Cambridge (. J Bone Jt Surg [Br]. 1998. ; . 80B. :. 777. ), a new coregistration imaging technique in the foot was described, using superimposed X-rays and technetium scintigram and showing significantly higher anatomical localisation of active joint disease than either alone. Nineteen consecutive patients over a three-year period (1996–9) with severe midfoot joint pain and disability of over six months’ duration underwent coregistration imaging followed by selective arthrodesis. The procedures involved 17 patients with one-level single or multiple fusions of the metatarsocuneiform, metatarsocuboid or naviculocuneiform joints, and two patients with two-level multiple fusions. Pain and functional assessments were recorded pre-operatively and at one and at two to four years postoperatively using the American Orthopaedic Foot and Ankle Society Midfoot Scoring System. Bone union was determined clinically and with X-rays. Results showed fusions in all 19 patients between 10 and 15 weeks. Three K-wires and one screw required removal for later prominence and there was one delayed wound healing. Pian and functional scores showed significant differences between the pre- and post-operative and one year measurements, and less between the one year and two to four year scores. This preliminary study concludes that there is a high correlation between the coregistration localisation of the midfoot degenerative arthropathies and the successful results of selective fusion of these joints for the one to four year follow-up period


Purpose: The purpose of the study was to evaluate the clinical and radiological results of Copeland cementless surface replacement arthroplasty (CSRA) applied in patients with two main indications. Patients and Methods: The study was conducted on fifty shoulders in fifty patients between 2003 and 2005; 17 patients suffered from rotator cuff pathology. The patients were prospectively followed up clinically and radiologically for a mean of 12.7 months (range, 6–30 months). There were 30 female and 20 male shoulders. The mean age was 66.63 years (range, 21–85). The mean operative time was 44.6 minutes (range, 29–62 minutes). The clinical assessment was performed with the Constant score. Results: The constant score significantly improved from a mean of 15.52 points preoperatively to 57.02 points postoperatively. Of the patients, 96% considered the shoulder to be much better or better as a result of the operation. The Constant-Score improved in the group with degenerative arthritis from 16.32 point pre- to 62.25 postoperatively. In rotator cuff arthropathy the score improved from 14.19 to 53.06. Radiologically, the humeral offset, the lateral gleno-humeral offset (coracoid base to the greater tuberosity) as well as the acromiohumeral distance were significantly increased. No intra-or postoperative complications encountered. Conclusion: We conclude that the shoulder surface replacement arthroplasty allows good conservation of the bone stock and avoiding the complications encountered with the stemmed prostheses. In patients with rotator cuff arthropathy there are two main indications:. - patients below the age of 70, in order to avoid complications of the reverse prosthesis. - patients with still a goof active range of motion


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXV | Pages 192 - 192
1 Jun 2012
Rajgopal A
Full Access

Introduction

Arthritic knees requiring total knee replacement may present with additional deformities located along the femur or tibia away from the articular region. These deformities may be congenital, developmental, associated with metabolic bone disease, or acquired as a result of malunited fractures or previous advocated for arthritic knee with ipsilateral extra-articular deformity.

Methods

We undertook retrospective study to evaluate the results of total knee arthroplasty in arthritic knee with extra-articular deformity in 26 knees (24 patients). Sixteen deformities were in tibia and ten deformities were in femur. All patients underwent total knee arthroplasty with intraarticular bone resection and soft tissue balancing.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 138 - 139
1 Mar 2009
rajeev A pullagura M pooley J
Full Access

Goodfellow & Bullough (1968) first described the pattern of articular cartilage wear in the elbow. More recent post mortem studies have shown that advanced degenerative changes can develop in the radio-capitellar (lateral) compartment of elbow joints of elderly subjects in which the humero-ulnar (medial) compartment remains remarkably well preserved. The significance of this post-mortem findings,in an elderly population, with unknown elbow symptom logy, who died from diverse causes, is unknown. There has been no clinically based,in vivo,study of this subject. Our study would support these observations, but indicates that symptomatic degenerative change occurs at a much earlier age than had previously been thought.

We have reviewed the findings in a consecutive series of 117 elbow arthroscopies performed on patients with elbow pain resistant to conservative treatments (age range 21–80 years: mean age 51 years). We documented established degenerative changes involving articular cartilage in 68 patients (59%). In this group we found that in 60 patients (88%) the degenerative changes were confined to the lateral compartment and contrasted with normal appearances of the articular cartilage of the medial compartment.

The findings presented in this work are in full agreement with previous work on the articular wear and biomechanics of the elbow joint. Previous studies which have been on cadaveric specimens, with findings of uncertain symptomatic relevance. To our knowledge, this finding has not previously been demonstrated in a symptomatic, young population. Unicompartmental lateral degeneration of the elbow is therefore a real clinical entity rather than a interesting post mortem finding. As such, it demands consideration in terms of investigation, diagnosis and treatment. It is likely that in the past, many patients have been misdiagnosed as having chronic lateral epicondylitis.

We consider that lateral compartment degenerative change is a distinct clinical entity. It begins in relatively young patients in whom the x ray appearance may be normal or near normal and is often diagnosed as lateral epicondylitis. Our observations taken together with the reported post mortem studies indicate that primary osteoarthritis of the elbow begins in the lateral compartment of the joint and may remain confined to the lateral compartment throughout life. We believe that new treatment strategies need to be developed specifically for patients with primary osteoarthritis as opposed to degenerative joint disease due to other causes.


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_I | Pages 96 - 96
1 Mar 2009
Heers G Grifka J Borisch N
Full Access

Abstract: Although the unconstrained pyrocarbon prosthesis (Ascension®) has been presented as a new alternative in the treatment of idiopathic arthritis of the proximal interphalangeal joint of the hand a few years ago, there is still a lack of studies analyzing the results of this implant.

In this study 10 patients (13 implants), that were tretated with this type of prosthesis between february 2002 and january 2005 were studied. All but one patient were satisfied with the postoperative situation and would agree to another operation.

A significant pain reduction was observed. The average ROM was 58degrees. Five patients demonstrated a free extension, two patients had a swan neck defomity, which could be actively compensated for, and the remaining six patients had an extension deficit of 30–45degrees. The average flexion was 76° (+/−12°).

X-ray examination was unremarkable in eight patients with a regular position of the endoprosthesis. However, in five patients significant radiolucent lines (> = 1mm) were observed. So far, a luxation of the prosthesis has not occurred and all implants are still in-situ. However, a dorsal tenoarthrolysis had to be performed in 3 patients.

The results of this study show a high rate of patient satisfaction with a significant pain reduction. The radiological results have to be closely monitored in the future.

Long-term results with a higher number of patients are necessary. A central registry for finger implants is recommended.


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 67 - 67
1 Jan 2003
Phillips N Ali A Stanley D
Full Access

The long term results of the ulnohumeral arthroplasty have not previously been reported using a recognised elbow scoring system.

Kashiwagi reported his results in 1986 but no validated scoring system was used in the publication. Morrey in 1992 evaluated his results using the Mayo Elbow Performance Score but the mean follow-up interval was only 33 months.

Between 1990 and 1996 twenty consecutive ulnohumeral arthroplasties were performed for primary degenerative disease of the elbow.

Outcome assessment using the DASH questionnaire and the Mayo Elbow Performance Score was taken at a mean follow-up of 75 months (range 58 to 132). Excellent or good results were identified in 85% (17/20) using the DASH questionnaire, and 65% (13/20) on assessment with the Mayo Elbow Performance Score (correlation coefficient 0.79).

Eighty percent (16/20) felt that the benefits of surgery had been maintained, and of those working at the time of surgery, 75% (12/16) were still employed in the same vocation.

There was no correlation between radiographic recurrence and the degree of fixed flexion deformity, flexion arc or elbow scores.


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 25 - 25
11 Apr 2023
Richter J Ciric D Kalchschmidt K D'Aurelio C Pommer A Dauwe J Gueorguiev B
Full Access

Reorientating pelvic osteotomies are performed to improve femoral head coverage and secondary degenerative arthritis. A rectangular triple pelvic innominate osteotomy (3PIO) is performed in symptomatic cases. However, deciding optimal screw fixation type to avoid complications is questionable. Therefore, this study aimed to investigate the biomechanical behavior of two different acetabular screw configurations used for rectangular 3PIO osteosynthesis. It was hypothesized that bi-directional screw fixation would be biomechanically superior to mono-axial screw fixation technique. A rectangular 3PIO was performed in twelve right-side artificial Hemi-pelvises. Group 1 (G1) had two axial and one transversal screw in a bi-directional orientation. Group 2 (G2) had three screws in the axial direction through the iliac crest. Acetabular fragment was reoriented to 10.5° inclination in coronal plane, and 10.0° increased anteversion along axial plane. Specimens were biomechanically tested until failure under progressively increasing cyclic loading at 2Hz, starting at 50N peak compression, increasing 0.05N/cycle. Stiffness was calculated from machine data. Acetabular anteversion, inclination and medialization were evaluated from motion tracking data from 250-2500 at 250 cycle increments. Failure cycles and load were evaluated for 5° change in anteversion. Stiffness was higher in G1 (56.46±19.45N/mm) versus G2 (39.02±10.93N/mm) but not significantly, p=0.31. Acetabular fragment anteversion, inclination and medialization increased significantly each group (p≤0.02) and remained non-significantly different between the groups (p≥0.69). Cycles to failure and failure load were not significantly different between G1 (4406±882, 270.30±44.10N) and G2 (5059±682, 302.95±34.10N), p=0.78. From a biomechanical perspective, the present study demonstrates that a bi-directional screw orientation does not necessarily advantageous versus mono-axial alignment when the latter has all three screws evenly distributed over the osteotomy geometry. Moreover, the 3PIO fixation is susceptible to changes in anteversion, inclination and medialization of the acetabular fragment until the bone is healed. Therefore, cautious rehabilitation with partial weight-bearing is recommended


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_7 | Pages 15 - 15
8 May 2024
Coetzee C Myerson M Anderson J McGaver RS
Full Access

Introduction. AlloStem/Cellular Bone Allograft and autologous bone graft are accepted methods for managing hindfoot degenerative arthritis. The purpose was to evaluate outcomes of AlloStem and autograft in subtalar arthrodesis and compare overall fusion rates. Methods. This study was conducted in IRB compliance. Patients between 18–80 years who qualified for a subtalar fusion were randomized 1:1 to AlloStem or autologous graft. The AOFAS hindfoot ankle scale, FFI-R and SF-12 were collected pre-operatively, 6 weeks, 3 & 6 months, 1 and 2 year. Weight-bearing 3-view ankle X-rays were done at the same intervals. A CT scan was obtained at 6 months. Results. 140 patients were enrolled; 124 patients had surgery(60-AlloStem and 64-Control). Withdrawals included 14 voluntarily before surgery and 2 intra-operative failures. 19 were lost to follow-up. Mean age for AlloStem was 56.69(20.3–79.6) and Autograft was 54.60(20.74–80.07). 59 AlloStem patients completed their 6 month visit and 45 completed 2 years. AOFAS score improved: 40.02 at pre-op to 72.16(6 mo) to 79.51 at 1 year and 80.38 at 2 year. SF-12 improved 58.29 at pre-op to 65.67 at 6 month and 71.59 at 2 year. FFI-R improved 236.88 at pre-op to 203.53 at 6 month 149.93 at 2 year.60 Autograft patients completed their 6 month visit and 51 patients completed their 2 year. AOFAS score improved 42.89 at pre-op to 75.67 (6 mo) to 79.75 at 1 year and 78.62 at 2 year. Autograft SF-12 improved 60.55 at pre-op to 70.40 at 6 month and 75.26 at 2 year. Autograft FFI-R improved 217.16 at pre-op to 166.77 at 6 month and 145.43 at 2 year. AlloStem patients had a mean posterior fusion rate of 28.9% at 6 months whereas the Autograft had 46.3%(p=.049). Non-union rates were AlloStem(9/57)(15.7%) whereas Autograft was 3/60(5%). Conclusion. AlloStem trended to be inferior to Autologous graft


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 107 - 107
2 Jan 2024
Park H
Full Access

The rotator cuff tendinopathy is one of the most common shoulder problems leading to full-thickness rotator cuff tendon tear and, eventually, to degenerative arthritis. Recent research on rotator cuff tendon degeneration has focused on its relationship to cell death. The types of cell death known to be associated with rotator cuff tendon degeneration are apoptosis, necrosis, and autophagic cell death. The increased incidence of cell death in degenerative tendon tissue may affect the rates of collagen synthesis and repair, possibly weakening tendon tissue and increasing the risk of tendon rupture. The biomolecular mechanisms of the degenerative changes leading to apoptotic cell death in rotator cuff tenofibroblasts have been identified as oxidative-stress-related cascade mechanisms. Furthermore, apoptosis, necrosis, and autophagic cell death are all known to be mediated by oxidative stress, a condition in which ROS (reactive oxygen species) are overproduced. Lower levels of oxidative stress trigger apoptosis; higher levels mediate necrosis. Although the signaltransduction pathway leading to autophagy has not yet been fully established, ROS are known to be essential to autophagy. A neuronal theory regarding rotator cuff degeneration has been developed from the findings that glutamate, a neural transmitter, is present in increased concentrations in tendon tissues with tendinopathy and that it induces rat supraspinatus tendon cell death. Recent studies have reported that hypoxia involved in rotator cuff tendon degeneration. Because antioxidants are known to scavenge for intracellular ROS, some studies have been conducted to determine whether antioxidants can reduce cell death in rotator cuff tendon-origin fibroblasts. The first study reported that an antioxidant has the ability to reduce apoptosis in oxidative-stressed rotator cuff tenofibroblasts. The second study reported that antioxidants have both antiapoptotic effects and antinecrotic effects on rotator cuff tendon-origin fibroblasts exposed to an oxidative stimulus. The third study reported that an antioxidant has antiautophagic-cell-death effects on rotator cuff tendon-origin fibroblasts exposed to an oxidative stimulus. The fourth study reported that glutamate markedly increases cell death in rotator cuff tendonorigin fibroblasts. The glutamate-induced cytotoxic effects were reduced by an antioxidant, demonstrating its cytoprotective effects against glutamate-induced tenofibroblast cell death. The fifth study reported that hypoxia significantly increases intracellular ROS and apoptosis. The hypoxia-induced cytotoxic effects were markedly attenuated by antioxidants, demonstrating their cytoprotective effects against hypoxia-induced tenofibroblast cell death. In conclusion, antioxidants have cytoprotective effects on tenofibroblasts exposed in vitro to an oxidative stressor, a neurotransmitter, or hypoxia. These cytoprotective effects result from antiapoptotic, antinecrotic, and antiautophagic actions involving the inhibition of ROS formation. These findings suggest that antioxidants may have therapeutic potential for rotator cuff tendinopathy. Further studies must be conducted in order to apply these in vitro findings to clinical situations


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_I | Pages 33 - 33
1 Mar 2006
Tibesku C Szuwart T Ocken S Skwara A Fuchs S
Full Access

Aim: Investigations on human hyaline cartilage of late stage degenerative arthritis showed that the vascular derived endothelian growth factor (VEGF) seems to play a role in the development of degenerative arthritis. The current study was designed to evaluate the expression of VEGF on chondrocytes of hyaline cartilage in the time course of degenerative arthritis. Methods: In twelve white new-zealand-rabbits the anterior cruciate ligament was resected to create an anterior instability of the knee. In twelve control rabbits only a sham operation without resection of the ACL was done. Another four animals have not been operated at all (0 weeks). Four animals of each group were sacrificed at three, six and twelve weeks each. After opening of the knee joint, the degenerative arthritis was macroscopically graded and the hyaline cartilage of the load bearing area was evaluated histologically according to Mankin and by immunostaining for VEGF. Results: The macroscopic and histological grade of degenerative arthritis according to Mankin showed a positive linear correlation to the time after surgery. The scores of the control group were constant in the time course. In the cartilage of the untreated animals (0 weeks) an average of 12 percent (SD 2.6) VEGF-positive chondrocytes were found. After 3 weeks the trial group (17.6%; SD 5.7) as well as the control group showed a significant increase (16.2%; SD 4.7). After 6 weeks the value in the control group dropped to normal (11.5%; SD 5.9) and remained constant after 12 weeks (11.6%; SD 3.3). In the trial group the percentage of VEGF positive chondrocytes rose steadily (19.4%; SD 4.6 after 6 weeks; 21.3%; SD 5.4 after 12 weeks). There was a positive linear correlation between the percentage of VEGF positive cells and the Mankin score (r=0.767; p< 0.01) and the macroscopic score (r=0.518; p=0.02). Conclusion: The current study shows for the first time an in-vivo increase of VEGF expression on chondrocytes in the time course of osteoarthritis, which is dependent on macroscopic and histological grades. Further studies are needed to evaluate whether this pattern applies to human beings and whether new treatment approaches could evolve from this knowledge


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_5 | Pages 49 - 49
1 Apr 2022
Birkenhead P Birkenhead P
Full Access

Introduction. Leg length discrepancy (LLD) is a common sequalae of limb reconstruction procedures. The subsequent biomechanical compensation can be directly linked to degenerative arthritis, lower back pain, scoliosis and functional impairment. It becomes particularly problematic when >2cm, established as a clinical standard. This two-arm experimental study assesses how reliable an iPhone application is in the measurement of LLD at different distances in control and LLD patients. Materials and Methods. 42 participants were included in the study, divided evenly into 21 control and 21 LLD patients. A standardised measurement technique was used to obtain TMM and iPhone application measurements, taken at a distance of 0.25m, 0.50m and 0.75m. Results. The mean discrepancy of iPhone-based measurements in the control group was 1.57cm, 1.59cm and 2.19cm at 0.25m, 0.50m and 0.75m respectively. This compares to measurements in the LLD cohort with a mean discrepancy of 1.71cm, 1.85cm and 2.19cm. The overall mean discrepancy of iPhone data was 1.78cm in the control cohort compared to 1.92cm in the LLD cohort. Conclusions. Results suggest that the iPhone application can be used to identify clinically significant leg length discrepancies. At 0.75 metres anomalous results become more prevalent and the accuracy of the application appears to decline. The results also suggest the application is slightly more accurate in the control group, nevertheless, in distances up to 0.50 metres the mean discrepancy sits within the 2cm standard of clinically significant LLD


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_IV | Pages 472 - 472
1 Apr 2004
Hazmy CW Angel K Dobson P
Full Access

Introduction This study was conducted in order to evaluate the patterns of utilization of arthroscopic knee debridement for the treatment of degenerative arthritis and the five years outcome following an initial arthroscopic procedure at our institution. Methods This is a retrospective study on all patients with degenerative arthritis of the knee who had their first arthroscopic debridement between 1992 and 1995, and had a follow-up of at least five years or ended up with total knee replacement (TKR). Patients with other prior surgery to the knee were excluded. The patients were divided into four groups based on the first arthroscopic finding using the Outerbridge grading system (Stage I: Softening, II: Fibrillation, III: Fragmentation, IV: Eburnation). The clinical status following the first arthroscopy and during the last follow-up were evaluated. The duration between the first arthroscopic debridement and TKR were also taken into account. Two hundred and two cases were included in the study which consists of 114 male and 88 female with mean age of 58.7 years. The mean follow-up was 5.4 years. There were 15 cases in stage I, 96 in stage II, 58 in stage III and 33 in stage IV. Results Following the first arthroscopic debridement, 93.7% of patients in stage I and II became asymptomatic compared to 26.4% in stage III and in IV where 60.4% still presented with recurrent symptoms. On the last follow-up, 18.9% in stage I and II had total knee replacement done compared to 78.0% in stage III and IV. The mean duration between the first arthroscopic debridement and TKR was 8.6 years in stage II, 3.3 years in stage III and 1.5 years in stage IV. Conclusions This study has shown that given the proper selection of patients and the correct stage of degenerative arthritis, arthroscopic debridement can still be a successful palliative, temporizing treatment for the osteoarthritic knee. It is of utmost importance that the patient’s pre-operative expectations have to be clearly objectified


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_15 | Pages 75 - 75
1 Mar 2013
Ichikawa R Funayama A Fujie A Kawasakiya S
Full Access

Introduction. Acetabular dysplasia is a common cause of osteoarthritis of the hip. Chiari pelvic osteotomy enables medialization of the center of the femoral head and improvement of coverage over the femoral head for hip dysplasia and prevents or delays progression of degenerative arthritis. We reviewed 104 patients after this augmentation procedure. Patients and methods. Between 1989 and 2000, 167 patients with developmental dysplasia of the hip had undergone the surgery at university hospital. Among them, 104 patients were able to be traced after surgery for more than 10 years. The mean follow-up period was 15.5 years. There were 96 women and 8 men with an average age of 34.3 years at surgery. The average angle of osteotomy was 6.6 degree craniad to the horizontal plane. Ratio of migration of the distal pelvis was 42%. Results. 8 hips were replaced by prosthesis. Setting total hip arthroplasty as an end point, 10-year, 15-year and 20-year survival rate was 99.0, 92.3 and 70.0% respectively. Patients with minimal grade of osteoarthritis at the time of osteotomy preserved 5.4 mm joint space on plain radiographs of last time follow-up. Patients with moderate or severe grade of osteoarthritis at the time of surgery had only 2.5 mm joint space at last. All patients with minimal grade of osteoarthritis could avoid total hip arthroplasty. Conclusion. Chiari pelvic osteotomy can prevent progression of degenerative arthritis in patients with minimal grade of osteoarthritis for more than 15 years


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 105 - 105
1 Sep 2012
Ferreira JF Cerqueira R Viçoso S Barbosa T Oliveira J Vasconcelos P
Full Access

Slipped capital femoral epiphysiolysis (SCFE) is a rare condition with a unknown aetiopathogenesis. An early diagnosis and treatment is essential to minimize premature degeneration of the joint. The authors reviewed the cases treated between 1980 and 2005 in our institution. This study was aimed at evaluating patients with hip epiphysiolysis surgically treated by canullated screws or pinning and previously controlled by short-term follow-up, in order to evaluate radiographic medium/ long term evolution, looking for evidence of degenerative arthritis or femoroacetabular impingement. We performed a retrospective review of the clinical notes and radiographs of all patients with slipped upper femoral epiphysis who were surgically treated at our institution between January 1980 and December 2005. These patients performed radiographs to detect evidence of osteonecrosis, chondrolysis, degenerative arthritis or femoroacetabular impingment. To grade the radiological osteoarthritic changes the grading system of Kellgren and Lawrence was used. These changes were correlated with the existence of femoroacetabular impingement. The radiological results were correlated with the Loder'sclassification of stability and the morphological classification. 43 patients were reviewed, corresponding to 47 treated hips. AP and Lowenstein x-ray views were taken in all patients. The alfa angle and the head-shaft angle were measured in the Lowenstein view (frog-leg). Of 16 patients with impingement only 1 patient didn't present pistol grip deformity. 4 contralateral hips also presented the deformity. The mean alfa angle was 99,4. 43% of the patients with unstable hips have impingment. In stable hips this percentage is of 35%. The Patrick test was positive in 30% of the hips with SCFE and only 17% of the unafected hips. The Kellgren and Lawrence scale was very diferent between trhe SCFE and control groups, with 43% grade 2, 17% grade 3 and 6% grade 4, versus 30% grade 2, 6% grade 3 and 0% grade 4. Some patients show bilateral pistol grip deformity and clinical signs of impingment, despite only having one hip with SCFE


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XL | Pages 135 - 135
1 Sep 2012
Park SE Kim SK
Full Access

Introduction. Patient demand for a less invasive surgical approach reducing the trauma induced to the joint has resulted in the development of Minimally Invasive Surgery (MIS). Although the length of the surgical incision is appealing to patients, the changes are not purely cosmetic. The surgery should not violate the extensor mechanism in any way. Incisions into the quadriceps tendon or into the vastus medialis muscle make the approach less difficult but this violation will slow the recovery and affect the ROM of the knee. In Asian knees, authors found the variation of VMO, which is essential in early functional recovery in TKA patient, is so much, so new clinical test for MIS QS should be needed to show location relationship between the upper pole of the patella and the insertion of VMO itself to avoid unnecessary injury of VMO during TKA. Purpose. The purpose of this comparison study was to verify whether MIS QS TKA can be a more functional and better method in treatment of advanced degenerative arthritis comparing with mini MIS TKA. Methods. Group I: MIS QS group were 50 knees (69.3±9.7 years) and follow up period of that were 28.8± 0.4 months. Group II: mini quad split MIS TKA were 200 knees knees (67.4±5.6 years) and follow up period of that were 34.2± 0.6 months. We did clinical and radiological assessment. Results. The length of incision of group I was 9.32±0.96 cm and that of group II was 10.9±0.5 cm. In clinical assessment, the postoperative pain score of group I was 47.5±2.74 points and that of group II was 47.4±3.27 points. The postoperative knee score of group I was 94.5±5.16 points and that of group II was 93.9±5.94 points. The postoperative knee functional score of group I was 90±8.94 points and that of group II was 93.4±6.73 points. The postoperative range of motion of group I was 122±16.9 degrees and that of group II was 116±23.5 degrees. In radiological assessment, The postoperative tibiofemoral angles of group I was 5±2.6 degrees and that of group II was 5.4±2.7 degrees. The α and β angle of group I was 95±3.5, 88±3.4 degrees and that of group II was 96±2.5, 89±2.4 degrees. The γ and δ angle of group I was 5.17±4.12, 85±1.4 degrees and that of group II was 3.96±3.1, 86±1.8 degrees. Conclusions. There were no significant differences in functions between two groups. Both MIS QS and mini Quad split TKA are an effective and safe method in treatment of advanced degenerative arthritis


Orthopaedic Proceedings
Vol. 102-B, Issue SUPP_8 | Pages 6 - 6
1 Aug 2020
Wilson I Gascoyne T Turgeon T Burnell C
Full Access

Total hip arthroplasty (THA) is one of the most successful and commonly performed surgical interventions worldwide. Based on registry data, at one-year post THA, implant survivorship is nearly 100% and patient satisfaction is 90%. A novel, porous coated acetabular implant was introduced in Europe and Australia in 2007. Several years after its introduction, warnings were issued for the system when used with metal-on-metal bearings due to adverse local tissue reaction, with one study reporting a 24% failure rate (Dramis et al. 2014). A subsequent 2018 study by Teoh et al. showed that the acetabular system had a survival rate of 98.9% at five years when used with conventional polyethylene or ceramic bearing surfaces. The current study was conducted to determine the safety and effectiveness of the acetabular system using standard highly-crosslinked polyethylene (XLPE) and ceramic liners at five-year follow-up. Our hypothesis was that the acetabular system would exhibit survivorship comparable to other acetabular components on the market at five-year follow-up. A prospective, non-randomized study was conducted from February 2009 to June 2017 at eight sites in Canada and the USA. One hundred fifty-five hips were enrolled and 148 hips analyzed after THA indicated for degenerative arthritis. At five-year follow-up, 103 subjects remained for final analysis. All patients received a zero, three, or multi-hole R3 acetabular shell with Stiktite porous coating (Smith & Nephew, Inc., Memphis, TN, USA). Standard THA surgical techniques were employed, with surgical approach and either of a XLPE or ceramic bearing surface chosen at the discretion of the surgeon. The primary outcome was revision at five-years post-op with secondary outcomes including the Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score (HOOS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), radiographic analysis, and post-operative adverse events. Data and outcomes were analyzed using summary statistics with 95% confidence intervals, t-tests, and Wilcoxon Rank tests. At five-year follow-up the overall success rate was 97.14% (95% CI: 91.88–100). When analyzed by liner type, the success rate was 96.81% (95% CI: 90.96–99.34) for polyethylene (n=94) and 100% (95% CI: 71.51–100) for ceramic (n=11), with no significant difference between either liner type (p=1). There were three revisions during the study (1.9%), two for femoral stem revision post fracture, and one for deep infection. The HHS (51.36 pre-op, 94.50 five-year), all 5 HOOS sub-scales, and WOMAC (40.9 pre-op, 89.13 five-year) scores all significantly improved (p < 0 .001) over baseline scores at all follow-up points. One (0.7%) subject met the criteria for radiographic failure at one-year post-op but did not require revision. Six (1.8%) of the reported adverse events were considered related to the study device, including four cases of squeaking, one bursitis, and one femur fracture. Results from this five-year, multicenter, prospective study indicate good survivorship for this novel, porous coated acetabular system. The overall survivorship of 97.14% at five-year follow-up is comparable to that reported for similar acetabular components and aligns with previous analyses (Teoh et al. 2018)


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_IV | Pages 580 - 580
1 Oct 2010
Kopylov P Abramo T Afendras G Tägil M
Full Access

Purpose: The management of Dorsal Fracture Dislocations of the PIP joint is challenging, especially for the unstable ones. Complications are common and often lead to functional disability. Many treatment methods have been described in the past, illustrating that no optimal solution has been found. In the Hemi-Hamate autograft technique, introduced by Hastings in 1999, a reconstruction of the volar lip joint surface and stabilization of the joint is achieved. This autograft can be seen as a model of a non vascularised bone-cartilage composite graft. The purpose of the present retrospective study was to evaluate the long term results of the hemi-hamate autograft technique in unstable PIP fracture-dorsal dislocations with special reference to posttraumatic degenerative arthritis common in non vascularized joint transfers. Materials and Methods: We report the results of 9 patients operated between November 2002 and March 2008 and with a minimum follow up of 26 months. The mean follow-up time was 56 months. There were 6 men and 3 women with a mean age at operation of 45 years (23–66). All fractures were unstable with comminution of the volar lip. In 3 patients the dominant hand was involved. The middle finger was injured in 4 patients, the ring finger in 4 and the little finger in 1 patient. All patients were treated with the operation technique described by Hastings and reanalyzed by Williams. The volar base of middle phalanx was debrided and reconstructed by a pre-sized autograft harvested from the dorsal side of the homolateral hamatum, and fixed with mini screws. A standard rehabilitation program was used postoperatively. Clinical (ROM, grip strength), radiographic and subjective outcomes (VAS) were examined in all patients. Results: At the last follow up, the injured finger had an average active ROM at the MCP joints of 97o (90o–115o) at the PIP 69 o (45 o –95 o) and at the DIP 59 o (30 o –90 o). The extension lag in the PIP joints were mean 10 o (0 o –30 o). Grip strength of the injured hand was mean 89% of the uninjured contralateral side. On radiographs, severe arthritis in the treated PIP was found in 2 of 9 patients. Another 2 patients had degenerative arthritis in several PIP. The average subjective score of patient’s satisfaction was 85 (20–100) in a scale 0–100 (100 best). Conclusions: The Hemi-Hamate autograft technique is a technically demanding operation but an alternative to arthrodesis or primary joint arthroplasty in the treatment of Fracture-Dorsal Dislocations of PIP joint. Our results are good and comparable to previously reported results (Williams 2001). Some deterioration will occur regarding joint osteoarthritis but a high degree of subjective patient satisfaction was found. Further studies and methods to decrease the osteoarthritis would be preferential


Orthopaedic Proceedings
Vol. 101-B, Issue SUPP_4 | Pages 95 - 95
1 Apr 2019
Osman A Tarabichi S Haidar F
Full Access

Introduction. Cementless Total Knee Replacement (TKR) was introduced to improve the longevity of implant; but has yet to be widely adopted because of reports of higher earlier failures in some series. The cementless TKR design has evolved recently and we have been using cementless component – both femoral and tibial on our patients. The long follow-up for fully TKR has been scarce in the literature. The purpose of this study isto investigate the minimum of ten years clinical and radiographic result of cementless titanium component and cementless tantalum component in primary TKR. Material & method. From 2008 to 2010 317 TKR underwent primary total knee with cementless femoral component titanium based (Zimmer Nexgen) and cementless tantalum component monoblock tibial component, The surgery was performed mainly on younger patients - average age was 48 yrs old ranging from 26 yrs old to 62 yrs old. All surgeries were performed by single surgeon. All patients were followed clinically and radiographically for a minimum of 8 yrs. Mean 7.8 years and range from 7 to 9 years. The underlying diagnosis for majority of the cases were degenerative arthritis in 97 of the cases and rheumatoid arthritis on the 3%. Result. We have revised 6 cases − 3 cases were for sepsis. They were revised in 2 stages. And we also revised 5 cases for loosening of femoral component. The tibial component revision for aseptic loosening or osteolysis for an end point for survivorship was a 100% for the tibia monoblock design. There was no radiographic evidence of tibial component loosening or subsidence, or migration at the time of the latest follow-up for tibia monoblock. On the femoral part we documented 16 cases other than those 4 revision for osteolysis, where limited osteolysis happened in some area of the tibial component but it did not affect stability and those has been followed up for a longer term. There was interesting phenomena in some of those cases where bone growth happened around the anterior cortex where it sealed the component entirely. Knee society scores improved from 51 pre-operatively to 94 pre-operatively on the last clinical visit. We had 32 cases where the patientswere able to regain their full mobility flexion of over 150 degrees. Conclusion. Our data clearly shows that the cementless TKR has excellent result as compared to the cemented with a good survival ship at 10 years. The tantalum tibial component shows an excellent survivorship. The femoral component also present reasonably good result but we still faced a few cases of loosening. The functional outcome for the implant with the surgery was satisfactory. With this result we strongly recommend using the cementless implant in young patients. We believe that cementless tibial is totally safe at this point as well as the femoral cementless prosthesis. However, we expect some improvement with the outcome with the femoral component when using the tantalum


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 89 - 89
1 Apr 2018
Kim S Jung Y Park Y Chang G Lee H
Full Access

Purpose. The purpose of this study is to compare the mid-term outcomes between rotating platform(RP) and posterior cruciate substitute(PS) bearings in LCS-total knee arthroplasty (TKA). Methods. This is a prospective randomized matched-pairs case–control study of patients who underwent primary TKAs with a minimum 2 years follow-up. The inclusion criteria was degenerative arthritis, and exclusion criteria was arthritis other than degeneration, previous operations such as osteotomy, body mass index (BMI) over 30 kg/m. 2. The matching criteria were set as age, BMI, preoperative ROM, gender, and the Knee Society (KS) and Hospital for Special Surgery (HSS) scores. After 1:1 matching, 50 cases involved the LCS RP bearing system as group 1 and 50 cases involved LCS PS bearing system group as group 2. Clinical and radiographic outcomes were evaluated. Results. The overall survival was 100% at final follow up. There were no complications between groups, such as infection, dislocation of bearing. The postoperative ROM was 122.3° ± 9.3 in group 1, 121.2° ± 9.7 in group 2. The KSKS scores were 93.5±7.2 in group 1, 92.8±3.6 in group 2 at final follow up. The KSFS scores were 87.5±7.7 in group 1, 86.9±6.8 in group 2 at final follow up. The HSS scores were 93.1±8.8 in group 1, 91.7±6.1 in group 2 at final follow up. There was no statistical difference in Hospital for Special Surgery Scores (HSS), Knee Society Scores (KSS) score evaluations between groups. However, the improvement of KSS and HSS scores was faster in group 1, the final scores were achieved at 3 to 6 months in group 1, at 6 to 1 year in group 2. Moreover, the KSFS scores were improved continuously until 2 years follow up. The postoperative mechanical axis was found as 1.2° ± 1.2 in group 1, 0.9° ± 0.9 in group 2. There were no statistical differences between groups in radiological evaluations including radiolucent lines. Conclusion. This study demonstrated that the PS-LCS prosthesis could provide satisfactory performance compared with that of the RP-LCS prosthesis with minimum 2-year follow-up, however, there could be disadvantages in PS-LCS prosthesis due to more bone loss in box cut in femur


Orthopaedic Proceedings
Vol. 97-B, Issue SUPP_1 | Pages 32 - 32
1 Feb 2015
McCarthy J
Full Access

There is an increased incidence of dislocation, dysplasia, slipped epiphysis, Perthes’ disease, and avascular necrosis leading to degenerative arthritis which occurs in up to 28% of Down's syndrome patients. As the life expectancy for patients with Down's syndrome has increased, so has the presence of hip disease. Hip replacement has been shown to have good results in this population. Special considerations include a high risk of postoperative dislocation and leg length inequality which often require large head THR or dual mobility type reconstruction to reduce these risks. Numerous spine deformities including scoliosis and C1-2 subluxation need to be taken into account-anesthesia consult