This paper presents the first report of a prospective study to assess the outcome of using coregistration localisation and selective arthrodesis in chronic midfoot
Purpose: The purpose of the study was to evaluate the clinical and radiological results of Copeland cementless surface replacement arthroplasty (CSRA) applied in patients with two main indications. Patients and Methods: The study was conducted on fifty shoulders in fifty patients between 2003 and 2005; 17 patients suffered from rotator cuff pathology. The patients were prospectively followed up clinically and radiologically for a mean of 12.7 months (range, 6–30 months). There were 30 female and 20 male shoulders. The mean age was 66.63 years (range, 21–85). The mean operative time was 44.6 minutes (range, 29–62 minutes). The clinical assessment was performed with the Constant score. Results: The constant score significantly improved from a mean of 15.52 points preoperatively to 57.02 points postoperatively. Of the patients, 96% considered the shoulder to be much better or better as a result of the operation. The Constant-Score improved in the group with
Arthritic knees requiring total knee replacement may present with additional deformities located along the femur or tibia away from the articular region. These deformities may be congenital, developmental, associated with metabolic bone disease, or acquired as a result of malunited fractures or previous advocated for arthritic knee with ipsilateral extra-articular deformity. We undertook retrospective study to evaluate the results of total knee arthroplasty in arthritic knee with extra-articular deformity in 26 knees (24 patients). Sixteen deformities were in tibia and ten deformities were in femur. All patients underwent total knee arthroplasty with intraarticular bone resection and soft tissue balancing.Introduction
Methods
Goodfellow &
Bullough (1968) first described the pattern of articular cartilage wear in the elbow. More recent post mortem studies have shown that advanced degenerative changes can develop in the radio-capitellar (lateral) compartment of elbow joints of elderly subjects in which the humero-ulnar (medial) compartment remains remarkably well preserved. The significance of this post-mortem findings,in an elderly population, with unknown elbow symptom logy, who died from diverse causes, is unknown. There has been no clinically based,in vivo,study of this subject. Our study would support these observations, but indicates that symptomatic degenerative change occurs at a much earlier age than had previously been thought. We have reviewed the findings in a consecutive series of 117 elbow arthroscopies performed on patients with elbow pain resistant to conservative treatments (age range 21–80 years: mean age 51 years). We documented established degenerative changes involving articular cartilage in 68 patients (59%). In this group we found that in 60 patients (88%) the degenerative changes were confined to the lateral compartment and contrasted with normal appearances of the articular cartilage of the medial compartment. The findings presented in this work are in full agreement with previous work on the articular wear and biomechanics of the elbow joint. Previous studies which have been on cadaveric specimens, with findings of uncertain symptomatic relevance. To our knowledge, this finding has not previously been demonstrated in a symptomatic, young population. Unicompartmental lateral degeneration of the elbow is therefore a real clinical entity rather than a interesting post mortem finding. As such, it demands consideration in terms of investigation, diagnosis and treatment. It is likely that in the past, many patients have been misdiagnosed as having chronic lateral epicondylitis. We consider that lateral compartment degenerative change is a distinct clinical entity. It begins in relatively young patients in whom the x ray appearance may be normal or near normal and is often diagnosed as lateral epicondylitis. Our observations taken together with the reported post mortem studies indicate that primary osteoarthritis of the elbow begins in the lateral compartment of the joint and may remain confined to the lateral compartment throughout life. We believe that new treatment strategies need to be developed specifically for patients with primary osteoarthritis as opposed to degenerative joint disease due to other causes.
In this study 10 patients (13 implants), that were tretated with this type of prosthesis between february 2002 and january 2005 were studied. All but one patient were satisfied with the postoperative situation and would agree to another operation. A significant pain reduction was observed. The average ROM was 58degrees. Five patients demonstrated a free extension, two patients had a swan neck defomity, which could be actively compensated for, and the remaining six patients had an extension deficit of 30–45degrees. The average flexion was 76° (+/−12°). X-ray examination was unremarkable in eight patients with a regular position of the endoprosthesis. However, in five patients significant radiolucent lines (>
= 1mm) were observed. So far, a luxation of the prosthesis has not occurred and all implants are still in-situ. However, a dorsal tenoarthrolysis had to be performed in 3 patients. The results of this study show a high rate of patient satisfaction with a significant pain reduction. The radiological results have to be closely monitored in the future. Long-term results with a higher number of patients are necessary. A central registry for finger implants is recommended.
The long term results of the ulnohumeral arthroplasty have not previously been reported using a recognised elbow scoring system. Kashiwagi reported his results in 1986 but no validated scoring system was used in the publication. Morrey in 1992 evaluated his results using the Mayo Elbow Performance Score but the mean follow-up interval was only 33 months. Between 1990 and 1996 twenty consecutive ulnohumeral arthroplasties were performed for primary degenerative disease of the elbow. Outcome assessment using the DASH questionnaire and the Mayo Elbow Performance Score was taken at a mean follow-up of 75 months (range 58 to 132). Excellent or good results were identified in 85% (17/20) using the DASH questionnaire, and 65% (13/20) on assessment with the Mayo Elbow Performance Score (correlation coefficient 0.79). Eighty percent (16/20) felt that the benefits of surgery had been maintained, and of those working at the time of surgery, 75% (12/16) were still employed in the same vocation. There was no correlation between radiographic recurrence and the degree of fixed flexion deformity, flexion arc or elbow scores.
Reorientating pelvic osteotomies are performed to improve femoral head coverage and secondary
Introduction. AlloStem/Cellular Bone Allograft and autologous bone graft are accepted methods for managing hindfoot
The rotator cuff tendinopathy is one of the most common shoulder problems leading to full-thickness rotator cuff tendon tear and, eventually, to
Aim: Investigations on human hyaline cartilage of late stage
Introduction. Leg length discrepancy (LLD) is a common sequalae of limb reconstruction procedures. The subsequent biomechanical compensation can be directly linked to
Introduction This study was conducted in order to evaluate the patterns of utilization of arthroscopic knee debridement for the treatment of
Introduction. Acetabular dysplasia is a common cause of osteoarthritis of the hip. Chiari pelvic osteotomy enables medialization of the center of the femoral head and improvement of coverage over the femoral head for hip dysplasia and prevents or delays progression of
Slipped capital femoral epiphysiolysis (SCFE) is a rare condition with a unknown aetiopathogenesis. An early diagnosis and treatment is essential to minimize premature degeneration of the joint. The authors reviewed the cases treated between 1980 and 2005 in our institution. This study was aimed at evaluating patients with hip epiphysiolysis surgically treated by canullated screws or pinning and previously controlled by short-term follow-up, in order to evaluate radiographic medium/ long term evolution, looking for evidence of
Introduction. Patient demand for a less invasive surgical approach reducing the trauma induced to the joint has resulted in the development of Minimally Invasive Surgery (MIS). Although the length of the surgical incision is appealing to patients, the changes are not purely cosmetic. The surgery should not violate the extensor mechanism in any way. Incisions into the quadriceps tendon or into the vastus medialis muscle make the approach less difficult but this violation will slow the recovery and affect the ROM of the knee. In Asian knees, authors found the variation of VMO, which is essential in early functional recovery in TKA patient, is so much, so new clinical test for MIS QS should be needed to show location relationship between the upper pole of the patella and the insertion of VMO itself to avoid unnecessary injury of VMO during TKA. Purpose. The purpose of this comparison study was to verify whether MIS QS TKA can be a more functional and better method in treatment of advanced
Total hip arthroplasty (THA) is one of the most successful and commonly performed surgical interventions worldwide. Based on registry data, at one-year post THA, implant survivorship is nearly 100% and patient satisfaction is 90%. A novel, porous coated acetabular implant was introduced in Europe and Australia in 2007. Several years after its introduction, warnings were issued for the system when used with metal-on-metal bearings due to adverse local tissue reaction, with one study reporting a 24% failure rate (Dramis et al. 2014). A subsequent 2018 study by Teoh et al. showed that the acetabular system had a survival rate of 98.9% at five years when used with conventional polyethylene or ceramic bearing surfaces. The current study was conducted to determine the safety and effectiveness of the acetabular system using standard highly-crosslinked polyethylene (XLPE) and ceramic liners at five-year follow-up. Our hypothesis was that the acetabular system would exhibit survivorship comparable to other acetabular components on the market at five-year follow-up. A prospective, non-randomized study was conducted from February 2009 to June 2017 at eight sites in Canada and the USA. One hundred fifty-five hips were enrolled and 148 hips analyzed after THA indicated for
Purpose: The management of Dorsal Fracture Dislocations of the PIP joint is challenging, especially for the unstable ones. Complications are common and often lead to functional disability. Many treatment methods have been described in the past, illustrating that no optimal solution has been found. In the Hemi-Hamate autograft technique, introduced by Hastings in 1999, a reconstruction of the volar lip joint surface and stabilization of the joint is achieved. This autograft can be seen as a model of a non vascularised bone-cartilage composite graft. The purpose of the present retrospective study was to evaluate the long term results of the hemi-hamate autograft technique in unstable PIP fracture-dorsal dislocations with special reference to posttraumatic
Introduction. Cementless Total Knee Replacement (TKR) was introduced to improve the longevity of implant; but has yet to be widely adopted because of reports of higher earlier failures in some series. The cementless TKR design has evolved recently and we have been using cementless component – both femoral and tibial on our patients. The long follow-up for fully TKR has been scarce in the literature. The purpose of this study isto investigate the minimum of ten years clinical and radiographic result of cementless titanium component and cementless tantalum component in primary TKR. Material & method. From 2008 to 2010 317 TKR underwent primary total knee with cementless femoral component titanium based (Zimmer Nexgen) and cementless tantalum component monoblock tibial component, The surgery was performed mainly on younger patients - average age was 48 yrs old ranging from 26 yrs old to 62 yrs old. All surgeries were performed by single surgeon. All patients were followed clinically and radiographically for a minimum of 8 yrs. Mean 7.8 years and range from 7 to 9 years. The underlying diagnosis for majority of the cases were
Purpose. The purpose of this study is to compare the mid-term outcomes between rotating platform(RP) and posterior cruciate substitute(PS) bearings in LCS-total knee arthroplasty (TKA). Methods. This is a prospective randomized matched-pairs case–control study of patients who underwent primary TKAs with a minimum 2 years follow-up. The inclusion criteria was
There is an increased incidence of dislocation, dysplasia, slipped epiphysis, Perthes’ disease, and avascular necrosis leading to