Advertisement for orthosearch.org.uk
Results 1 - 20 of 34
Results per page:
Bone & Joint Research
Vol. 13, Issue 11 | Pages 632 - 646
7 Nov 2024
Diaz Dilernia F Watson D Heinrichs D Vasarhelyi E

Aims. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against Staphylococcus aureus. Methods. We performed in vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10 µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated its sensitivity to killing, comparing wild type (WT) and CopAZB-deficient USA300 strains. Results. UAMS-1 demonstrated a greater sensitivity to SF compared to USA300 WT at 12 hours (p = 0.001) and 24 hours (p = 0.027). UAMS-1 died in statistically significant quantities at 24 hours (p = 0.017), and USA300 WT survived at 24 hours. UAMS-1 was more susceptible to the addition of copper at four (p = 0.001), 12 (p = 0.005), and 24 hours (p = 0.006). We confirmed a high sensitivity to killing with the addition of exogenous copper on both strains at four (p = 0.011), 12 (p = 0.011), and 24 hours (p = 0.011). WT and CopAZB-deficient USA300 strains significantly died in SF, demonstrating a MBC-Cu of 50 µM against USA300 WT (p = 0.011). Conclusion. SF has antimicrobial properties against S. aureus, and UAMS-1 was more sensitive than USA300 WT. Adding 10 µM of copper was highly toxic, confirming its bactericidal effect. We found CopAZB proteins to be involved in copper effluxion by demonstrating the high sensitivity of mutant strains to lower copper concentrations. Thus, we propose CopAZB proteins as potential targets and use exogenous copper as a treatment alternative against S. aureus


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_12 | Pages 78 - 78
1 Dec 2022
Dilernia FD Watson D Heinrichs D Vasarhelyi E
Full Access

Staphylococcus aureus is the most frequently isolated organism in periprosthetic joint infections. The mechanism by which synovial fluid (SF) kills bacteria has not yet been elucidated, and a better understanding of its antibacterial characteristics is needed. We sought to analyze the antimicrobial properties of exogenous copper in human SF against S. aureus. SF samples were collected from patients undergoing total elective knee or hip arthroplasty. Different S. aureus strains previously found to be sensitive and resistant, UAMS-1 and USA300 WT, respectively, were used. We performed in-vitro growth and viability assays to determine the capability of S. aureus to survive in SF with the addition of 10µM of copper. We determined the minimum bactericidal concentration of copper (MBC-Cu) and evaluated the sensitivity to killing, comparing WT and CopAZB-deficient USA300 strains. UAMS-1 evidenced a greater sensitivity to SF when compared to USA300 WT, at 12 (p=0.001) and 24 hours (p=0.027). UAMS-1 significantly died at 24 hours (p=0.017), and USA300 WT survived at 24 hours. UAMS-1 was more susceptible to the addition of copper at 4 (p=0.001), 12 (p=0.005) and 24-hours (p=0.006). We confirmed a high sensitivity to killing with the addition of exogenous copper on both strains at 4 (p=0.011), 12 (p=0.011), and 24 hours (p=0.011). Both WT and CopAZB-deficient USA300 strains significantly died in SF, evidencing a MBC-Cu of 50µM against USA300 WT (p=0.011). SF has antimicrobial properties against S. aureus, and UAMS-1 was more sensitive than USA300 WT. The addition of 10µM of copper was highly toxic for both strains, confirming its bactericidal effect. We evidenced CopAZB-proteins involvement in copper effluxion by demonstrating the high sensitivity of the mutant strain to lower copper concentrations. Thus, we propose CopAZB-proteins as potential targets and the use of exogenous copper as possible treatment alternatives against S. aureus


Bone & Joint Research
Vol. 12, Issue 9 | Pages 601 - 614
21 Sep 2023
Gu P Pu B Liu T Yue D Xin Q Li H Yang B Ke D Zheng X Zeng Z Zhang Z

Aims. Mendelian randomization (MR) is considered to overcome the bias of observational studies, but there is no current meta-analysis of MR studies on rheumatoid arthritis (RA). The purpose of this study was to summarize the relationship between potential pathogenic factors and RA risk based on existing MR studies. Methods. PubMed, Web of Science, and Embase were searched for MR studies on influencing factors in relation to RA up to October 2022. Meta-analyses of MR studies assessing correlations between various potential pathogenic factors and RA were conducted. Random-effect and fixed-effect models were used to synthesize the odds ratios of various pathogenic factors and RA. The quality of the study was assessed using the Strengthening the Reporting of Observational Studies in Epidemiology using Mendelian Randomization (STROBE-MR) guidelines. Results. A total of 517 potentially relevant articles were screened, 35 studies were included in the systematic review, and 19 studies were eligible to be included in the meta-analysis. Pooled estimates of 19 included studies (causality between 15 different risk factors and RA) revealed that obesity, smoking, coffee intake, lower education attainment, and Graves’ disease (GD) were related to the increased risk of RA. In contrast, the causality contribution from serum mineral levels (calcium, iron, copper, zinc, magnesium, selenium), alcohol intake, and chronic periodontitis to RA is not significant. Conclusion. Obesity, smoking, education attainment, and GD have real causal effects on the occurrence and development of RA. These results may provide insights into the genetic susceptibility and potential biological pathways of RA. Cite this article: Bone Joint Res 2023;12(9):601–614


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 66 - 66
2 Jan 2024
Nikody M Li J Koper D Balmayor E Habibovic P Moroni L
Full Access

Critical-sized bone defects remain challenging in the clinical setting. Autologous bone grafting remains preferred by clinicians. However, the use of autologous tissue is associated with donor-site morbidity and limited accessibility to the graft tissue. Advances in the development of synthetic bone substitutes focus on improving their osteoinductive properties. Whereas osteoinductivity has been demonstrated with ceramics, it is still a challenge in case of polymeric composites. One of the approaches to improve the regenerative properties of biomaterials, without changing their synthetic character, is the addition of inorganic ions with known osteogenic and angiogenic properties. We have previously reported that the use of a bioactive composite with high ceramic content composed of poly(ethyleneoxide terephthalate)/poly(butylene terephthalate) (1000PEOT70PBT30, PolyActive, PA) and 50% beta-tricalcium phosphate (β-TCP) with the addition of zinc in a form of a coating of the TCP particles can enhance the osteogenic differentiation of human mesenchymal stromal cells (hMSCs) (3). To further support the regenerative properties of these scaffolds, inorganic ions with known angiogenic properties, copper or cobalt, were added to the coating solution. β-TCP particles were immersed in a zinc and copper or zinc and cobalt solution with a concentration of 15 or 45 mM. 3D porous scaffolds composed of 1000PEOT70PBT30 and pure or coated β-TCP were additively manufactured by 3D fibre deposition. The osteogenic and angiogenic properties of the fabricated scaffolds were tested in vitro through culture with hMSCs and human umbilical vein endothelial cells, respectively. The materials were further evaluated through ectopic implantation in an in vivo mini-pig model. The early expression of relevant osteogenic gene markers (collagen-1, osteocalcin) of hMSCs was upregulated in the presence of lower concentration of inorganic ions. Further analysis will focus on the evaluation of ectopic bone formation and vascularisation of these scaffolds after implantation in a mini-pig ectopic intramuscular model


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 28 - 28
24 Nov 2023
De Vecchi E Balzano V Bottagisio M Gavioli L
Full Access

Aim. Antibacterial activity of coatings based on metal and metal oxide nanoparticles (NPs) often depends on materials and biotic targets resulting in a material-specific killing activity of selected Gram-positive and Gram-negative bacteria, including drug-resistant strains. In this perspective, the NPs loading amount, the relative elemental concentration inside the nanogranular building blocks and the deposition method are of paramount importance when the goal is to widen the antimicrobial spectrum, but at the same time to avoid high levels of metal content to limit undesired toxic effects. Aim of the present study was evaluation of the antimicrobial properties of two multielement nanogranular coatings composed of Titanium-Silver and Copper and of Magnesium-Silver and Copper. Method. Ti-Ag-Cu and Mg-Ag-Cu NPs were deposited on circular cover glasses (VWR) by Supersonic Cluster Beam Deposition. Biofilm-producer strains of Staphylococcus aureus (methicillin susceptible and resistant), Staphylococcus epidermidis (methicillin susceptible and resistant), Escherichia coli (fully susceptible and producer of extended spectrum beta lactamases), and Pseudomonas aeruginosa (susceptible and multidrug-resistant) were selected. The abilities of the selected strains to adhere, colonize and produce biofilm on the discs coated with Ti-Ag-Cu or Mg-Ag-Cu NPs were compared to uncoated circular cover glasses which were used as growth control. Cytotoxicity was also evaluated in order to assess the biocompatibility of the newly synthesized NPs. Results. In comparison to uncoated controls, both coatings showed significant anti-adhesive properties against S. aureus, S. epidermidis, and E. coli. Reduction in adhesion to Mg-Ag-Cu coated discs was observed also for P. aeruginosa isolates, although differences vs uncoated controls did not reach statistical significance. Biofilm formation was reduced on discs coated with Mg-Ag-Cu compared to Ti-Ag-Cu and, again, coatings had a milder effect on P. aeruginosa, probably due to its exceptional capability of attachment and matrix production. These results were confirmed by the evaluation of bacterial colonization on nanoparticles-coated discs by means of confocal laser scanning microscopy. A viability of 95.8% and 89.4% of cells cultured in the presence of Ti-Ag-Cu and Mg-Ag-Cu discs, respectively, when compared to negative controls was observed, thus excluding cytotoxic effects on eukaryotic cells. Conclusions. The newly synthesized Ti-Ag-Cu and Mg-Ag-Cu coatings are able to limit bacterial adhesion colonization and biofilm production, thus highlighting the safe use of multi-element families of NPs as new strategies against bacterial attachment to the surface of biomedical implants. However, further studies addressing activity against P. aeruginosa and including a wide number of isolates are warranted


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 121 - 121
1 Nov 2018
Jacobs A Renaudin G Vichery C Forestier C Charbonnel N Descamps S
Full Access

Biphasic calcium phosphates (BCP) are the most frequently used materials because of their mineral analogy with bio-mineral part of bones. Their chemical synthesis can be modulated by doping, in order to respond to the biological needs. We present here the biological responses induced by copper ions in solution, to characterize its cytotoxicity and antibacterial activity. We also investigate the antibacterial property of Cu-doped BCP (Ca10 Cu0.1 (PO4)6 (OH)1.8 O0.2) on a strain of clinical interest: S. aureus, compared to undoped BCP. The sol-gel route has been used to prepare the BCP ceramics. Human BMC (Bone Marrow Cells) were obtained from metaphysal cancellous bone collected during hip arthroplasty and used for cytotoxicity evaluations. A strain of Staphylococcus aureus isolated from an osteoarticular infection after total knee arthroplasty was used to evaluate antibacterial activities. Results indicate that 3 ppm of copper ions leads to the death of all cultured bacteria in 24 hours and 25 ppm caused the death of all cells in 15 days. Regarding BCP, the undoped bioceramics increased the bacterial growth compared to a control without bioceramic. After 16 hours of contact, the copper ions released by the Cu-doped BCP induced a significant decrease of the bacterial concentration, indeed no viable bacteria were found. These materials seem to be a promising alternative for the preparation of multifunctional bone substitutes


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_15 | Pages 98 - 98
1 Nov 2018
Ryan EJ Ryan AJ Philippart A Ciraldo FE Boccaccini AR Kearney CJ O'Brien FJ
Full Access

The bone infection osteomyelitis (typically Staphylococcus aureus) requires a multistep treatment process including: surgical debridement, long-term systemic high-dose antibiotics, and often bone grafting. With antibiotic resistance becoming increasingly concerning, alternative approaches are urgently needed. Herein, we develop a one-step treatment for osteomyelitis that combines local, controlled release of non-antibiotic antibacterials (copper) within a proven regenerative scaffold. To maximise efficacy we utilised bioactive glass – an established material with immense osteogenic capacity – as a copper ion delivery reservoir. Copper ions have also been shown to stimulate angiogenesis and induce MSC differentiation down an osteogenic lineage. To eliminate grafting requirements, the copper-doped BG was incorporated into our previously developed collagen scaffolds to produce multifunctional antibacterial, osteogenic, and angiogenic scaffolds. Scaffolds were fabricated by freeze-drying a co-suspension of collagen and bioactive glass particles (+/− copper doping, referred to as CuBG and BG, respectively) at a range of different concentrations (0–300% w/w bioactive glass/collagen). Scaffolds demonstrated a 2.7-fold increase in compressive modulus (300% CuBG vs. 0%; p≤0.01), whilst maintaining >98% porosity. The 300% CuBG scaffolds showed significant antibacterial activity against Staphylococcus aureus (p≤0.001). In terms of osteogenesis, both 100% and 300% CuBG scaffolds increased cell-mediated calcium deposition on the scaffolds at day 14 and 28 (p≤0.05 and p≤0.001), as confirmed by alizarin red staining. 100% CuBG scaffolds significantly enhanced angiogenesis by increased tubule formation (p≤0.01) and VEGF protein production (p≤0.001) (all ≥n=3). In summary, this single-stage, off-the-shelf treatment for osteomyelitis shows potential to minimise bone grafting and antibiotic dependence, while reducing hospital stays and costs


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_8 | Pages 47 - 47
11 Apr 2023
Kamphof R Pijls B Lima R Cama G
Full Access

Prosthetic Joint Infection (PJI) is a devastating complication that can occur after total joint replacement surgery. With increasing antimicrobial resistance, there is a need for non-antibiotic approaches to treat and prevent PJI. Doping calcium phosphates with antimicrobial ions shows promise for these purposes. This systematic review aims to search and summarise the evidence-base for the potential of calcium phosphates doped with different antimicrobial ions. A systematic review was conducted on PubMed, Embase, Web-Of-Science, Cochrane Library and Emcare of in vitro and animal studies on the antimicrobial activity of (co)substituted calcium phosphates according to PRIMSA guidelines.. The research protocol, listing search terms and in/exclusion criteria, was registered a priori at . https://doi.org/10.7910/DVN/HEP18U. Data was extracted regarding ions, micro-organisms and antimicrobial activity. The search retrieved 1017 hits of which 148 papers were included. The substitution of 33 different ions was reported. Silver (n= 46), zinc (n=39), copper (n=18) and magnesium (n=14) were the most commonly doped ions. 36 different micro-organisms were studied of which E. coli (n=109), S. aureus (n=99), and C. albicans (n=22) were the most common. 6 different outcomes were reported, most commonly the K-ratio (n=53), the log CFU (n=41) and the bacterial inhibition zone (n=39). A validated outcome for the evaluation of biofilm prevention was lacking. There was considerable heterogeneity in studied ions, micro-organisms and reported outcomes. A lack of clearly defined reporting guidelines in the field of antimicrobial materials has led to the use of clinically irrelevant micro-organisms and a general lack of consistency of the methods used and the reported results. Currently, there is no universally accepted measure for the effectiveness required from biomaterials for treatment and prevention of PJI


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_1 | Pages 114 - 114
2 Jan 2024
Maglio M Tschon M Sartori M Martini L Rocchi M Dallari D Giavaresi G Fini M
Full Access

The use of implant biomaterials for prosthetic reconstructive surgery and osteosynthesis is consolidated in the orthopaedic field, improving the quality of life of patients and allowing for healthy and better ageing. However, there is the lack of advanced innovative methods to investigate the potentialities of smart biomaterials, particularly for the study of local effects of implant and osteointegration. Despite the complex process of osseointegration is difficult to recreate in vitro, the growing challenges in developing alternative models require to set-up and validate new approaches. Aim of the present study is to evaluate an advanced in vitro tissue culture model of osteointegration of titanium implants in human trabecular bone. Cubic samples (1.5×1.5 cm) of trabecular bone were harvested as waste material from hip arthroplasty surgery (CE AVEC 829/2019/Sper/IOR); cylindrical defects (2 mm Ø, 6 mm length) were created, and tissue specimens assigned to the following groups: 1) empty defects- CTR-; 2) defects implanted with a cytotoxic copper pin (Merck cod. 326429)- CTR+; 3) defects implanted with standard titanium pins of 6 µm-rough (ZARE S.r.l) -Ti6. Tissue specimens were cultured in mini rotating bioreactors in standard conditions, weekly assessing viability. At the 8-week-timepoint, immunoenzymatic, microtomographic, histological and histomorphometric analyses were performed. The model was able to simulate the effects of implantation of the materials, showing a drop in viability in CTR+, differently from Ti6 which appears to have a trophic effect on the bone. MicroCT and histological analysis supported the results, with lower BV/TV and Tb.Th values observed in CTR- compared to CTR+ and Ti6 and signs of matrix and bone deposition at the implant site. The collected data suggest the reliability of the tested model which can recreate the osseointegration process in vitro and can therefore be used for preliminary evaluations to reduce and refine in vivo preclinical models. Acknowledgment: This work was supported by Emilia-Romagna Region for the project “Sviluppo di modelli biologici in vitro ed in silico per la valutazione e predizione dell'osteointegrazione di dispositivi medici da impianto nel tessuto osseo”


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_17 | Pages 30 - 30
24 Nov 2023
van Hoogstraten S Samijo S Geurts J Arts C
Full Access

Aim. Prosthetic joint infections pose a major clinical challenge. Developing novel material surface technologies for orthopedic implants that prevent bacterial adhesion and biofilm formation is essential. Antimicrobial coatings applicable to articulating implant surfaces are limited, due to the articulation mechanics inducing wear, coating degradation, and toxic particle release. Noble metals are known for their antimicrobial activity and high mechanical strength and could be a viable coating alternative for orthopaedic implants [1]. In this study, the potential of thin platinum-based metal alloy coatings was developed, characterized, and tested on cytotoxicity and antibacterial properties. Method. Three platinum-based metal alloy coatings were sputter-coated on medical-grade polished titanium discs. The coatings were characterized using optical topography and scanning electron microscopy with energy dispersive spectroscopy (SEM/EDS). Ion release was measured using inductively coupled plasma optical emission spectrometry (ICP-OES). Cytotoxicity was tested according to ISO10993-5 using mouse fibroblasts (cell lines L929 and 3T3). Antibacterial surface activity, bacterial adhesion, bacterial proliferation, and biofilm formation were tested with gram-positive Staphylococcus aureus ATCC 25923 and gram-negative Escherichia coli ATCC 25922. Colony forming unit (CFU) counts, live-dead fluorescence staining, and SEM-EDS images were used to assess antibacterial activity. Results. Three different platinum-based metal alloys consisting of platinum-iridium, platinum-copper, and platinum-zirconium. The coatings were found 80 nm thick, smooth (roughness average < 60 nm), and non-toxic. The platinum-copper coating showed a CFU reduction larger than one logarithm in adherent bacteria compared to uncoated titanium. The other coatings showed a smaller reduction. This data was confirmed by SEM and live-dead fluorescence images, and accordingly, ICP-OES measurements showed low levels of metal ion release from the coatings. Conclusions. The platinum-copper coating showed low anti-adhesion properties, even with extremely low metal ions released. These platinum-based metal alloy coatings cannot be classified as antimicrobial yet. Further optimization of the coating composition to induce a higher ion release based on the galvanic principle is required and copper looks most promising as the antimicrobial compound of choice. Acknowledgments. This publication is supported by the DARTBAC project (with project number NWA.1292.19.354) of the research program NWA-ORC which is (partly) financed by the Dutch Research Council (NWO); and the AMBITION project (with project number NSP20–1-302), co-funded by the PPP Allowance made available by Health-Holland, Top Sector Life Sciences & Health to ReumaNederland


Orthopaedic Proceedings
Vol. 104-B, Issue SUPP_14 | Pages 21 - 21
1 Dec 2022
Montesissa M Farè S Draghi L Rau J Gualandi C Focarete M Boi M Baldini N Graziani G
Full Access

Favoring osseointegration and avoiding bacterial contamination are the key challenges in the design of implantable devices for orthopedic applications. To meet these goals, a promising route is to tune the biointerface of the devices, that can regulate interactions with the host cells and bacteria, by using nanostructured antibacterial and bioactive coatings. Indeed, the selection of adequate metal-based coatings permits to discourage infection while avoiding the development of bacterial resistance and nanostructuring permits to tune the release of the antimicrobial compounds, allowing high efficacy and decreasing possible cytotoxic effects. In addition, metal-doped calcium phosphates-based nanostructured coatings permit to tune both composition and morphology of the biointerfaces, allowing to regulate host cells and bacteria response. To tune the biointerfaces of implantable devices, nanostructured coatings can be used, but their use is challenging when the substrate is heat-sensitive and/or porous. Here, we propose the use of Ionized Jet Deposition (IJD) to deposit metallic and ion-doped calcium phosphates materials onto different polymeric substrates, without heating and damaging the substrate morphology. 3D printed scaffolds in polylactic acid (PLA) and polyurethane (PU), and electrospun matrices in polycaprolactone (PCL) and PLA were used as substrates. Biogenic apatite (HA), ion doped (zinc, copper and iron) tricalcium phosphate (TCP) and silver (Ag) coatings were obtained on porous and custom-made polymeric substrates. Chemical analyses confirmed that coatings composition matches that of the target materials, both in terms of main phase (HA or TCP) and ion doping (presence of Cu, Zn or Fe ion). Deposition parameters, and especially its duration time, influence the coating features (morphology and thickness) and substrate damage. Indeed, SEM/EDS observations show the presence of nanostructured agglomerates on substrates surface. The dimensions of the aggregates and the thickness of the coating films increase increasing the deposition time, without affecting the substrate morphology (no porosity alteration or fibers damaging). The possible substrate damage is influenced by target and substrate material, but it can be avoided modulating deposition time. Once the parameters are optimized, the models show suitable in vitro biological efficacy for applications in bone models, regenerative medicine and infection. Indeed, HA-based coatings favor cells adhesion on printed and electrospun fibers. For antibacterial applications, the ion doped TCP coatings can reduce the bacterial growth and adhesion (E.coli and S.aureus) on electrospun matrices. To conclude, it is possible achieve different properties applying nanostructured coatings with IJD technique on polymeric substrates, modulating deposition conditions to avoid substrate damage


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_2 | Pages 132 - 132
2 Jan 2024
Rau J
Full Access

Over the last decades, biodegradable metals emerged as promising materials for various biomedical implant applications, aiming to reduce the use of permanent metallic implants and, therefore, to avoid additional surgeries for implant removal. However, among the important issue to be solved is their fast corrosion - too high to match the healing rate of the bone tissue. The most effective way to improve this characteristic is to coat biodegradable metals with substituted calcium phosphates. Tricalcium phosphate (β-TCP) is a resorbable bioceramic widely used as synthetic bone graft. In order to modulate and enhance its biological performance, the substitution of Ca2+ by various metal ions, such as strontium (Sr2+), magnesium (Mg2+), iron (Fe2+) etc., can be carried out. Among them, copper (Cu2+), manganese (Mn2+), zinc (Zn2+) etc. could add antimicrobial properties against implant-related infections. Double substitutions of TCP containing couples of Cu2+/Sr2+ or Mn2+/Sr2+ ions are considered to be the most perspective based on the results of our study. We established that single phase Ca3−2x(MˊMˊˊ)x(PO4)2 solid solutions are formed only at x ≤ 0.286, where Mˊ and Mˊˊ—divalent metal ions, such as Zn2+, Mg2+, Cu2+, Mn2+, and that in case of double substitutions, the incorporation of Sr2+ ions allows one to extend the limit of solid solution due to the enlargement of the unit cell structure. We also reported that antimicrobial properties depend on the substitution ion occupation of Ca2+ crystal sites in the β-TCP structure. The combination of two different ions in the Ca5 position, on one side, and in the Ca1, Ca2, Ca3, and Ca4 positions, on another side, significantly boosts antimicrobial properties. In the present work, zinc-lithium (Zn-Li) biodegradable alloys were coated with double substituted Mn2+/Sr2+ β-TCP and double substituted Cu2+/ Sr2+ β-TCP, with the scope to promote osteoinductive effect (due to the Sr2+ presence) and to impart antimicrobial properties (thanks to Cu2+ or Mn2+ ions). The Pulsed Laser Deposition (PLD) method was applied as the coating's preparation technique. It was shown that films deposited using PLD present good adhesion strength and hardness and are characterized by a nanostructured background with random microparticles on the surface. For coatings characterization, Fourier Transform Infrared Spectroscopy, X-ray Diffraction, and Scanning Electron Microscopy coupled with Energy Dispersive X-ray and X-ray Photoelectron Spectroscopy were applied. The microbiology tests on the prepared coated Zn-Li alloys were performed with the Gram-positive (Staphylococcus aureus, Enterococcus faecalis) and Gram-negative (Salmonella typhimurium, Escherichia coli) bacteria strains and Candida albicans fungus. The antimicrobial activity tests showed that Mn2+/Sr2+ β-TCP -coated and Cu2+/Sr2+ β-TCP coated Zn-Li alloys were able to inhibit the growth of all five microorganisms. The prepared coatings are promising in improving the degradation behavior and biological properties of Zn-Li alloys, and further studies are necessary before a possible clinical translation


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_III | Pages 248 - 248
1 Jul 2011
Innes M Tschirhart CE McErlain DD Holdsworth DW Gordon KD Hurtig M
Full Access

Purpose: The mechanical function and strain behavior of the knee meniscus is not fully understood, due to multiple tissues with disparate properties, as well as complex contact patterns and intricate loading mechanisms. More comprehensive understanding of joint mechanics may contribute to improved treatment options for patients with injuries and osteoarthritis. There is very limited information available on the 3D strain of the intact meniscus. The objective of this work was to use mCT with copper microsphere markers to quantify three-dimensional strain of the meniscus under physiologic loading. Method: Two healthy fresh frozen ovine knee specimens were harvested. Copper microspheres (0.5mm) were injected into anterior and posterior tetrahedral clusters in the medial meniscus using 20-gauge hypodermic needles. Needle cavities were sealed with ovine tendon tissue. Joints were loaded to 100% body weight in a 4 DOF CT-compatible pneumatically-driven device with flexion angles ranging from 62–98°. Images were acquired with an eXplore Locus Ultra mCT scanner and reconstructed with commercial software. A time series of images were acquired with the joint unloaded, during static loading, and at a reduced load (25% BW). Results: The average maximum principle strains in the anterior element of the two specimens at 62o of flexion increased by 21% during loading and decreased by 13% during unloading. The maximum principle strains were 28% larger in the anterior element than the posterior. The strains in the anterior element decreased by 6.5% with time following load application, and decreased by 16% with load reduction, yielding relatively low residual strain. Strains were 2% larger in the anterior portion with larger flexion angles. Conclusion: The objective of this work was to develop a reliable method for quantifying 3D strains in the meniscus. Results support the notion that mCT imaging with copper microspheres in the meniscus may be a viable technique for more comprehensive 3D strain analysis. The relatively low residual strains measured in this study indicate that copper microspheres are stable markers in this application. This technique may be useful in directing future studies aimed at understanding the impact of meniscal pathologies and the success of repair techniques


Orthopaedic Proceedings
Vol. 91-B, Issue SUPP_III | Pages 467 - 467
1 Sep 2009
Dawson S MacGillivray T Muir A Simpson A
Full Access

An uncomplicated, quantitative method of determining density from X-rays would be of extreme value to clinicians. In this study we perform a thorough assessment of applying a step wedge to grey level calibration method to X-rays obtained using Computed Radiography (CR). An Aluminium step wedge of ten, 5mm-thick steps was X-rayed with a Fuji CR system together with a knee phantom (3M) at various energy and Fuji processing settings. Automatic detection of the steps by means of the Hough transform was used to assess optimum CR settings. Background variation due to the anode Heel effect was evaluated by acquiring an “empty field” X-ray at different energy settings and with copper filtering. The effects of beam hardening were considered with a custom-made phantom which was also used to assess correcting for soft tissue and bone thickness. X-rays taken at higher energy settings and with wider windowing imaged the widest number of steps (nine) and gave the best accuracy in modelling the step thickness to grey level relationship. Fitting a straight line to the log of the net grey levels gives an excellent model of the data (R2 = 0.99). X-rays of copper sheeting show that automatic histogram analysis is performed by the Fuji CR system, which can have unpredictable effects on aluminium thickness to grey level relationship. Background variation in the anode-cathode direction due to the Heel effect was corrected with a 1D exponential model (R2 = 0.99), allowing position-independent measurements to be obtained. Correcting for bone thickness, soft tissue and beam hardening further improves measurement quality. Use of step wedge calibration to provide quantitative information on plain X-rays without altering their clinical quality is possible using digital radiography. However, a thorough assessment of the entire X-ray process is necessary to achieve accurate and comparable information


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_14 | Pages 118 - 118
1 Nov 2018
Bistolfi A
Full Access

The discussion will focus on new approaches to reduce bacterial adhesion on the surface of polymethylmethacrylate (PMMA) in contact with bone, comparing the clinical and engineering point of view. One possibility is to encourage and speed up direct interaction with the bone, for example by adding a bioactive phase in the cement (hydroxyapatite, glass and bioactive glass ceramic). A widespread strategy is also the addition of different types of antibiotics (gentamicin, tobramycin vancomycin, etc.), although they are known to have some drawbacks: not complete release, resistant strain development. Another strategy could be represented by the PMMA-based composite cements loaded with a completely inorganic filler consisting of a bioactive glass doped with ions whose bioactivity mechanism is well-known and encompasses a chemical and biological interaction with tissues promoting osteoinduction. Bioactive glasses can be doped with antibacterial ions (silver, copper, etc.) preserving their biocompatibility and bioactivity and, at the same time, acquiring antibacterial properties. Thus, it is possible to produce composite cements that combine the properties of the polymer matrix with those of the inorganic filler, overcoming the main problems associated with the use of antibiotics. An additional possibility is the addition of essential oils, vegetable oils with remarkable antibacterial properties


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_16 | Pages 93 - 93
1 Nov 2018
Martín-Saavedra FM Escudero-Duch C Prieto M Sánchez-Casanova S López D Arruebo M Voellmy R Santamaría J Vilaboa N
Full Access

As near-infrared (NIR) photothermal agents, copper sulfide nanoparticles (CuSNP) offer several advantages over plasmonic gold nanoparticles (GNP), the most widely used photothermal nanotransducers in biomedical applications. CuSNP exhibit strong optical absorption at NIR wavelengths (650–1100 nm) and convert it into heat due excitation of electronic transitions or plasmonic photoexcitation. In contrast with GNP, CuSNP are degradable, readily prepared, inexpensive to produce, efficiently cleared from the body and their photothermal efficiency is less sensitive to the dielectric constant of the surrounding medium. We explored the feasibility of CuSNP to function as degradable NIR nanotransducers within fibrin-based cellular scaffolds, paying great attention to the stability and photothermal efficiency of the composite. We tested in vitro and in vivo whether NIR-responsive fibrin hydrogels comprising CuSNP (CuSNP hydrogels) are reliable platforms for triggering transgene expression in cells harboring a gene circuit activatable by heat and dependent of rapamycin. NIR laser irradiation of the CuSNP hydrogels increased local temperature and, in the presence of rapamycin, triggers the gene switch based on the promoter of the highly heat-inducible HSP70B gene (HSPA7). After implantation of such a cell-containing CuSNP hydrogel, transgenic expression can be remotely triggered by NIR-irradiation. Interestingly, we found that CuSNP hydrogels induce remodeling activity in stem cells and stimulate an angiogenic response. In short, CuSNP hydrogels offer compelling features for tissue engineering applications, as fully degradable implants with enhanced integration capacity in host tissues that can provide for remote control in the deployment of therapeutic gene products


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_27 | Pages 22 - 22
1 Jul 2013
Ismael S Lewis J
Full Access

Graphene is a two-dimensional structure that is made of a single-atom-thick sheet of carbon atoms organised in hexagonal shapes. It is considered to be the mother of all graphite or carbon-based structures. It has shown exceptional physical and chemical properties which possess potential future applications. Graphene has an elasticity index similar to rubber and a hundred times tensile strength of steel and is even sturdier than diamonds. It is a very efficient biosensor with its exceptional electronic conductivity far greater than even copper. It is a potential future low cost material and its scalable production ability makes it even more attractive. The rediscovery of Graphene in 2008 saw few potential medical applications, specifically in the field of drug delivery, gene and cancer therapy. Nao graphene has extensive thermal conductivity and reflexivity, which can conceivably change imaging especially muskeloskeletal imaging and notably as a contrast material. It has been found to be a safe and a cheaper IV contrast agent in USA in 2012. Being an efficient biosensor especially in conducting electricity, it could assist in prosthetic and bionic limbs or prosthesis. Its durable stubborn properties, a composition which exceeds the strength of steel and light weight structure may create a potential material to develop into a new generation of a low profile internal fixing devices like plats. Most importantly, its scaffolding cell culturing assets could change the whole concept of prosthesis from mechanical press fit fixation to more dependence on bio adhesiveness


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_I | Pages 17 - 17
1 Jan 2011
Orpen N Shetty R Corner J Marshall R
Full Access

Decompression of the lumber spine for spinal stenosis is the most commonly performed spinal surgical procedure in patients over 60 years old. The aims of surgery are to relieve compression of the spinal nerves and retain integrity of the structural elements of the spinal column and its function as a supportive structure. In trying to avoid excessive removal of the posterior supportive structures of the spinal column without compromising full and safe decompression of the spinal nerves, techniques are being developed to reduce bone removal but also allow access to the spinal canal. One such micro-decompression involves a hemi-laminectomy and lateral recess decompression on the more symptomatic side followed by undercutting the spinous processes and decompressing the opposite side from within the canal aided by the use the operating microscope, a high speed burr and a copper moldable retractor to protect the dura and nerves. We have reviewed our first 100 consecutive patients who have had a spinal micro-decompression over a period of 5 years. 58 Female and 42 male patients are included in this series. Mean age was 65 years. Patients were assessed by a combination of clinical review and self-assessment questionnaires. After a follow-up period of up to five years (mean 3.5 years) we have seen symptomatic late instability develop in four patients requiring a further surgical procedure in two of these. Symptoms typically developed two years after the original operation following an initial improvement in radicular symptoms and back pain. This compares favourably with published results for wide decompression where re-operation rates of 18% are reported. We have analysed the cases of delayed instability in more detail to evaluate whether the late deterioration could have been predicted. Micro-decompression is shown to be safe with few complications and has advantages over wide decompression without compromising safety


Bone & Joint Research
Vol. 11, Issue 10 | Pages 700 - 714
4 Oct 2022
Li J Cheung W Chow SK Ip M Leung SYS Wong RMY

Aims

Biofilm-related infection is a major complication that occurs in orthopaedic surgery. Various treatments are available but efficacy to eradicate infections varies significantly. A systematic review was performed to evaluate therapeutic interventions combating biofilm-related infections on in vivo animal models.

Methods

Literature research was performed on PubMed and Embase databases. Keywords used for search criteria were “bone AND biofilm”. Information on the species of the animal model, bacterial strain, evaluation of biofilm and bone infection, complications, key findings on observations, prevention, and treatment of biofilm were extracted.


Orthopaedic Proceedings
Vol. 93-B, Issue SUPP_IV | Pages 567 - 567
1 Nov 2011
Antoniou J Petit A Nikolaou VS Papanastasiou C Mwale F Zukor DJ Huk OL
Full Access

Purpose: Several studies have shown elevated levels of metal ions in blood of patients with metal-on-metal (MM) total hip arthroplasty (THA). The outstanding question that remains is the clinical impact of these elevated ion levels. Even though it is well known that exposure to heavy metals such as lead, copper, mercury, nickel, and cadmium) may lead to significant alterations in human sperm morphology and motility, less is known on the effect of Co and Cr on semen parameters. The aim of the present study was to investigate the effect of metal ions on the semen of males of child fathering age with MM hip arthroplasty. Method: Semen was collected form 10 patients between 41 and 49 years old (mean = 45±6 years) by masturbation after 2–3 days of abstinence. Samples were examined within 1h after ejaculation for morphology, motility, and number of sperm cells following standard criteria from the World Health Organization (WHO). Co and Cr concentrations were measured in both the seminal plasma and in the blood of patients by inductively coupled plasma-mass spectroscopy (ICP-MS). Since spermatozoa membrane polyunsaturated fatty acids are vulnerable to attack by reactive oxygen species (leading to peroxide formation), peroxide concentrations were measured in both the seminal plasma and the blood of patients. Results: Results showed that the concentration of both Co and Cr ions was significantly lower in the seminal plasma than in the blood of the patients. Results also showed that the levels of peroxides were lower in the seminal plasma than in the blood plasma of these patients. Importantly, the ejaculate volume, the sperm density, the total sperm count, the pH, and the percentage of cells with normal morphology were in the range of the WHO criteria for fertile population and also in the range of reference patients in the city of measurements. However, the viability was a little bit lower than what was observed in a fertile population without prosthesis. Conclusion: The presence of Co and Cr ions in the blood of males of child fathering age with MM hip arthroplasty raised concerns about the quality of semen in these patients. Results of the present study strongly suggest that the raised of Co and Cr had no significant effect on sperm parameters of young patients with MM prosthesis. The methods used to identify potential normal and fertile semen samples are still contradictory and not exactly defined. Studies showed for example that only total numbers of sperm with progressive mobility are significantly different in the fertile than in sub-fertile men, while others suggested that the fertile population should be defined by sperm concentration or sperm morphology. In conclusion, results suggest that Co and Cr ions generated from MM prosthesis have no significant effect on the sperm parameters of young patients of child fathering age. Further longitudinal studies are however necessary to conclusively determine the effect of metal ions from MM prosthesis on sperm parameters