Abstract. Background. Aim of this study is to determine the difference between re-operation rates after conventional Methods of fixation of patella fractures using Metallic implants and novel technique of all suture fixation using Ethibond or fiber tape. Methods. This is a retrospective
Classifying trochlear dysplasia (TD) is useful to determine the treatment options for patients suffering from patellofemoral instability (PFI). There is no consensus on which classification system is more reliable and reproducible for the purpose of guiding clinicians’ management of PFI. There are also concerns about the validity of the Dejour Classification (DJC), which is the most widely used classification for TD, having only a fair reliability score. The Oswestry-Bristol Classification (OBC) is a recently proposed system of classification of TD, and the authors report a fair-to-good interobserver agreement and good-to-excellent intraobserver agreement in the assessment of TD. The aim of this study was to compare the reliability and reproducibility of these two classifications. In all, six assessors (four consultants and two registrars) independently evaluated 100 axial MRIs of the patellofemoral joint (PFJ) for TD and classified them according to OBC and DJC. These assessments were again repeated by all raters after four weeks. The inter- and intraobserver reliability scores were calculated using Cohen’s kappa and Cronbach’s α.Aims
Methods
The rise of multidrug-resistant bacteria and the decreasing efficacy of antibiotic therapy in successfully treating biofilm-associated infections are prompting the exploration of alternative treatment options. This study investigates the efficacy of different bioactive glass (BAG) formulations - alone or combined with vancomycin - to eradicate biofilm. Further, we study the influence of BAG on pH and osmotic pressure as important factors limiting bacterial growth. Different BAG-S53P4 formulations were used for this study, including (a) BAG-powder (<45 μm), (b) BAG-granules (500–800 μm), (c) a cone-shaped BAG-scaffold and (d) two kinds of BAG-putty containing granules, with no powder (putty-A) or with additional powder (putty-B), and a synthetic binder. Inert glass beads were included as control. All formulations were tested in a concentration of 1750 g/ml in Müller-Hinton-Broth. Targeted bacteria included methicillin-resistant To investigate the antibiofilm effect of BAG alone or combined with vancomycin, 3 hour-old MRSA or MRSE biofilms were formed on porous glass beads and exposed to BAG ± vancomycin for 24h, 72h and 168h. After co-incubation, biofilm-beads were deep-washed in phosphate-buffered saline and placed in glass vials containing fresh medium. Recovering biofilm bacteria were detected by measuring growth-related heat production at 37°C for 24h by isothermal microcalorimetry. Changes in pH and osmotic pressure over time were assessed after co-incubation of each BAG formulation in Müller-Hinton-Broth for 0h, 24h, 72h and 168h.Aim
Method
Aims. The metabolic variations between the cartilage of osteoarthritis (OA) and Kashin-Beck disease (KBD) remain largely unknown. Our study aimed to address this by conducting a
As patient data continues to grow, the importance of efficient and precise analysis cannot be overstated. The employment of Generative Artificial Intelligence (AI), specifically Chat GPT-4, in the realm of medical data interpretation has been on the rise. However, its effectiveness in comparison to manual data analysis has been insufficiently investigated. This quality improvement project aimed to evaluate the accuracy and time-efficiency of Generative AI (GPT-4) against manual data interpretation within extensive datasets pertaining to patients with orthopaedic injuries. A dataset, containing details of 6,562 orthopaedic trauma patients admitted to a district general hospital over a span of two years, was reviewed. Two researchers operated independently: one utilised GPT-4 for insights via prompts, while the other manually examined the identical dataset employing Microsoft Excel and IBM® SPSS® software. Both were blinded on each other's procedures and outcomes. Each researcher answered 20 questions based on the dataset including injury details, age groups, injury specifics, activity trends and the duration taken to assess the data. Upon comparison, both GPT-4 and the manual researcher achieved consistent results for 19 out of the 20 questions (95% accuracy). After a subsequent review and refined prompts (prompt engineering) to GPT-4, the answer to the final question aligned with the manual researcher's findings. GPT-4 required just 30 minutes, a stark contrast to the manual researcher's 9-hour analytical duration. This quality improvement project emphasises the transformative potential of Generative AI in the domain of medical data analysis. GPT-4 not only paralleled the accuracy of manual analysis but also achieved this in significantly less time. For optimal accurate results, data analysis by AI can be enhanced through human oversight. Adopting AI-driven approaches, particularly in orthopaedic data interpretation, can enhance efficiency and ultimately improve patient care. We recommend future investigations on large and more varied datasets to reaffirm these outcomes.
Classifying trochlear dysplasia (TD) is useful to determine the treatment options for patients suffering from patellofemoral instability (PFI). There is no consensus on which classification system is more reliable and reproducible for this purpose to guide clinicians in order to treat PFI. There are also concerns about validity of the Dejour classification (DJC), which is the most widely used classification for TD, having only a fair reliability score. The Oswestry-Bristol classification (OBC) is a recently proposed system of classification of TD and the authors report a fair-to-good interobserver agreement and good-to-excellent intra-observer agreement in the assessment of TD. The aim of this study was to compare the reliability and reproducibility of these two classifications. 6 assessors (4 consultants and 2 registrars) independently evaluated 100 magnetic resonance axial images of the patella-femoral joint for TD and classified them according to OBC and DJC. These assessments were again repeated by all raters after 4 weeks. The inter and intra-observer reliability scores were calculated using Cohen's kappa and Cronbach's alpha. Both classifications showed good to excellent interobserver reliability with high alpha scores. The OBC classification showed a substantial intra-observer agreement (mean kappa 0.628)[p<0.005] whereas the DJC showed a moderate agreement (mean kappa 0.572) [p<0.005]. There was no significant difference in the kappa values when comparing the assessments by consultants to those by registrars, in either classification systems. This large study from a non-founding institute shows both classification systems to be reliable for classifying TD based on magnetic resonance axial images of the patella-femoral joint, with the simple to use OBC having a higher intra-observer reliability score compared to the DJC.
Two-stage exchange arthroplasty is traditionally used to treat periprosthetic hip infection. Nevertheless, particularly in high-risk patients, there has been increased attention towards alternatives such as 1.5-stage exchange arthroplasty which takes place in one surgery. Therefore, we sought to compare (1) operative time, length-of-stay (LOS), transfusions, (2) causative organism identification and polymicrobial infection rates, (3) re-revision rates and re-revision reasons, (4) mortality, and determine (5) independent predictors of re-revision. Retrospective chart review of 71 patients who underwent either 1.5- (n=38) or 2-stage (n=33) exchange hip arthroplasty at a single institution (03/2019-05/2023). Demographics, surgical, inpatient, and infection characteristics were noted. Main outcomes evaluated were re-revision rates, re-revision reasons, mortality, and cause of death. Independent predictors of re-revision were assessed utilizing logistic regression. Mean follow: 675 days (range, 23–1,715). Demographics were not significantly different except for a higher proportion of 1.5-stage patients classified as American-Society-of-Anesthesiologists (ASA) status 3 or 4 (84.2 vs. 48.5%, p=0.002). Length of follow-up was significantly longer in the 2-stage group (924.4 vs. 458 days, p<0.001) as well as operative time (506 vs. 271 minutes, p<0.001). In the 1.5-stage group, there was a higher proportion of polymicrobial infections (23.7 vs. 3.0%, p=0.016), re-revision rates (28.9 vs. 9.1%, p=0.042) and periprosthetic infections as a cause of revision (90.9 vs. 0%, p=0.007). Mortality rates were not significantly different, and no patient died for causes related to infection. Type of surgery (1.5-stage vs. 2-stage) was the only independent predictor of re-revision (odds-ratio 4.0, 95% confidence-interval 1.02–16.16, p=0.046). Our data suggests that patients who undergo 1.5-stage exchange arthroplasty have a significantly higher re-revision rate (mostly due to infection) when compared to 2-stage patients. We acknowledge potential benefits of the 1.5-stage strategy, especially in high-risk patients since it involves single surgery. However, higher re-revision rates must be considered when counseling patients.
Kinematic variables have been identified as potential biomarkers for low back pain patients; however, an in-depth comparison between chronic (n=22), acute (n=15), and healthy controls (n=136) has not been done. This retrospective data analysis compared intervertebral lumbar motion parameters, angular range of motion, translation, maximum disc height, motion share inequality (MSI) and variability (MSV), and laxity, between these groups. Kinematic parameters were determined using video tracking techniques utilising quantitative fluoroscopy (QF), during both weight-bearing and recumbent controlled sagittal bending tasks. Data was analysed for normality, and appropriate statistical tests were applied to determine differences between groups. There were no significant differences between the groups for age, height, weight and sex. Whilst few differences were found between acute and healthy groups, differences were shown between both chronic and healthy, and acute and chronic groups for all six parameters. Of particular note were examples of differences in the motion share parameters between the acute and chronic populations, with an increased MSI in the chronic group during recumbent flexion, and MSV during recumbent extension, and inversely an increase in MSV in the acute group during weight-bearing flexion.Study purpose and background
Methods and results
Highly polished stems with force-closed design have shown satisfactory clinical results despite being related to relatively high early migration. It has been suggested that the minimal thickness of cement mantles surrounding the femoral stem should be 2 mm to 4 mm to avoid aseptic loosening. The line-to-line cementing technique of the femoral stem, designed to achieve stem press-fit, challenges this opinion. We compared the migration of a highly polished stem with force-closed design by standard and line-to-line cementing to investigate whether differences in early migration of the stems occur in a clinical study. In this single-blind, randomized controlled, clinical radiostereometric analysis (RSA) study, the migration pattern of the cemented Corail hip stem was compared between line-to-line and standard cementing in 48 arthroplasties. The primary outcome measure was femoral stem migration in terms of rotation and translation around and along with the X-, Y-, and Z- axes measured using model-based RSA at three, 12, and 24 months. A linear mixed-effects model was used for statistical analysis.Aims
Methods
The American Joint Replacement Registry (AJRR) is the largest registry of total hip and knee arthroplasty (THA and TKA) procedures performed in the U.S. The National (Nationwide) Inpatient Sample (NIS) is a public database containing demographic estimates based on more than seven million hospitalizations annually. The purpose of this study was to analyze whether AJRR data is representative of the national experience with TJA as represented in NIS Cohen's d effect sizes were computed to ascertain the magnitude of differences in demographics, hospital volume (in 50 patient increments), and geographic characteristics between the AJRR and NIS databases.Introduction
Methods
Unicameral bone cyst is a frequent benign lesion of the child’s skeleton of unclear ethopathology and scarce symptoms.Possible complications and limits in the child’s activities necessitate an active approach to management. Intracystic injection of corticosteroid depot, curettage of the cyst and bone grafting and osteoinduction procedures are three frequently used therapeutic procedures.Having in mind that attitudes regarding initial treatment are still heterogeneous, in period 1992–2001, we have conducted a study aimed at making a
This scientific work is a non-interventional, experimental and prospective comparative study of two very high-viscosity PMMA bone cements: Fast-setting PMMA bone cements are used in the endoprothetics of the patella and knee (in Australia) and are also used to cement an artificial acetabulum (in the UK). Are there any differences regarding the characteristics of the two fast-setting PMMA bone cements? All cements were mixed as specified by the manufacturer and analysed on the following parameters: handling properties (mixing, waiting, working and hardening phase), powder/liquid-ratio, mechanical properties (ISO 5833:2002 and DIN 53435), fatigue strength (ISO 16402) and elution profile. All tests were done in an acclimatised laboratory with temperatures set at 23.5°C ± 0.5°C and a humidity of >40%. Of two batch numbers, 11 units of each bone cement were tested.BACKGROUND
MATERIALS AND METHODS
Arthrodesis of the first metatarsophalangeal joint (MTPJ) is the most reliable surgical option, for hallux rigidus from end-stage osteoarthritis. The aim of the study was to compare the functional outcomes of memory nickel-titanium staples versus a compression plate with a cross screw construct for first MTPJ arthrodesis using the Manchester–Oxford Foot Questionnaire (MOXFQ). Patients who underwent MTPJ arthrodesis using either memory nickel-titanium staples or a compression plate with a cross screw construct were identified from the surgical lists of two orthopaedic consultants. Pre and post-operative MOXFQ questionnaire, a validated patient-reported outcome measure, was administered, and responses were analysed to derive the MOXFQ summary index. The study included 38 patients (staple group N=12 and plate and cross screw group N=26). 23 patients were female and 15 were male. Mean age was 64.8 years (SD 9.02; 40 to 82). Initial analysis showed no significant difference in preoperative MOXFQ scores between the groups (p = 0.04). Postoperatively, the staple group exhibited a mean improvement of 36.17, surpassing the plate group's mean improvement of 23. Paired t-test analysis revealed a statistically significant difference (t-score= 2.5, p = 0.008), favouring the use of staples. The findings indicate that the use of staples in MTPJ arthrodesis resulted in a significantly greater improvement in MOXFQ scores compared to plates. Further research is needed to explore the underlying factors contributing to this difference and to evaluate long-term effects on patient outcomes.
Objective: To evaluate the long term radiological and clinical outcome after posterior correction of adolescent right thoracic idiopathic scoliosis with Cotrel-Dubousset instrumentation (CDI) and Harrington rod instrumentation (HRI). Design: Retrospective
Background: context: In Adolescent Idiopathic Scoliosis (AIS), the correction of thoracic hypokyphosis with hooks instrumentation and also with pedicle screws system is moderate. Purpose: To compare radiographic results between two instrumentations with thoracic screws using two different. Methods: of reduction: cantilever reduction (CR group– MOSS-MIAMI system) versus simultaneous translation on two rods (ST group – PASSMED system). Study design: Retrospective
The aim of this study was to compare the results of Matti-Russe (MR) procedure and interpositional techniques (IT) in the management of scaphoid non-union. 50 scaphoid non-unions were included in this retrospective study. Demographics, initial management of fracture, location of non-union, time to surgery, procedure done and immobilisation time were recorded. Radiographs were analysed for union and deformity correction. Functional outcome was analysed using the Herbert's grading system. The mean age and time to surgery were 26.7 years and 15.9 months. Twenty-one patients had the MR procedure and twenty-nine patients had interpositional procedures with internal fixation. DISI was present in 17 patients. The mean postoperative change in the scapholunate angle with the MR procedure was 7.9° compared to 8.0° (p>0.05) for the IT procedures. Union rate was 76% for both procedures. The mean follow-up was 9.9 months. Functional results were Herbert 0 or 1 in 42 cases. The only significant prognostic variables were location of non-union and time to surgery. Similar deformity correction was achieved using both IT and MP procedures. MP procedure can be used in the management of scaphoid non-union even in the presence of deformity with good functional results.
Comparison between Aprotinin and Tranexamic acid on blood conservation in scoliosis surgery. There is no difference in the control of blood loss between 2 drugs.Purpose
Null hypothesis
Proper femoral component placement plays a key role in the success of a total knee replacement (TKR). Controversy exists on which technique should be used to ensure proper femoral component placement. This two-part study compares gap balancing (GB) and measured resection (MR) techniques used in TKR, investigating femoral component position and early clinical outcomes. Femoral component position was analyzed in 95 consecutive knees that underwent primary TKR. Both GB and MR cutting blocks from the same knee system were sequentially placed on the operative knee, marking the pin sits. A standardized photograph (Figure) was taken prior to making final femoral cuts. Relative rotation was determined based on measurements made from a commercially available software. Clinical comparison was made using 50 consecutive GB patients and 50 consecutive MR patients. Clinical outcome measures were Knee Society Scores (KSS), knee range of motion (ROM), functional ROM (FROM), tourniquet time, and patients having manipulations under anesthesia (MUA).Background
Methods
Search for optimal shape of hip implant have gone on from 70th’s. Different shapes of hip cups and methods of their implantation, which were created within those years, indicate, that long term results of cementless arthroplasty are still not satisfactory. The clinical and radiological results of cementless hip arthroplasty, which were performed with two types of shape cups (threaded spherical and threaded conical), were analyzed after at least 7 years follow up. Analysis was based on results 106 of cementless hip arthroplasties among 141, which were done during 1993 – 1996. The study concerned 58 threaded spherical cups (group A) and 48 conical (group B). Application of cups was randomized with respect to both sex and etiology of hip dysfunction and their implantation conditioned to possession of this type of implant on this moment. The mean age of 63 women and 35 men ( in 8 both side) in the moment of implantation were 48,9 years ( 10,6)and ranged from 28 to 76 years. Mean time of follow up was 8,2 years( 1,4) and ranged from 7 to 10 years. Pre- and postoperative clinical evaluation of hip function was carried out by means of Harris Hip Scale. Radiological evaluation was based on measurements of angle of inclination, horizontal and vertical migration of cup and radiolucent lines in DeLee-Charnley zones. Those measurements of last x-ray examination were compared with those, which were done immediately after arthroplasty. There were 80% of excellent and good results and 17% poor results in clinical evaluation of group A. In radiological evaluation of this group mean horizontal migration was 1mm, and vertical was 2,5mm. Clinical and radiological symptoms of cup loosening were confirmed in 10 hips. The revision procedures were performed in 9 hips. In group B excellent and good clinical results were in 98% and poor results only in 2 % of treated hips. Radiological evaluation also showed less migration of cups. Mean horizontal migration was 0,3mm, and vertical was 0,7mm. Clinical and radiological symptoms of loosening were in 1 hip, which were treated by revision procedure. Conclusion of our study is statement, that application of cementless threaded conical cup in hip arthroplasty give better clinical and radiological midterm results, than apllication of cementless threaded spherical cups.