Aim: To demonstrate that external þxation cannot be used alone to treat unstable distal radial fractures associated with a combination of dorsal and volar
The lack of a universal, consistent protocol for the subjective, objective and radiographic evaluation of these injuries has hampered the comparison of results. Methods. 45 patients with complex fractures of the calcaneus were included in this prospective study, which was undertaken from July 2003 to December 2005. The fracture classification of Essex-Lopresti was used. We also observed the extent of secondary fracture lines extending from the primary shear line (on axial and external oblique plain radiographs) to establish
Background: Numerous researchers have documented posterior
Objective: For humeral nonunions, plating is threatened by severe osteoporosis or
Purpose: Fractures o the distal radius remain a problem difficult to resolve. A post-operative displacement is observed in about half the cases. The displacement is generally a secondary shortening with mis- or unrecognized metaphyseal
Objectives. One commonly used rat fracture model for bone and mineral research
is a closed mid-shaft femur fracture as described by Bonnarens in
1984. Initially, this model was believed to create very reproducible
fractures. However, there have been frequent reports of comminution
and varying rates of complication. Given the importance of precise
anticipation of those characteristics in laboratory research, we
aimed to precisely estimate the rate of
In an attempt to formulate a classification that might facilitate prognostication of outcome and possibly dictate early intervention, we conducted a retrospective review of fractures in which the extent of diaphyseal
Aims. The purpose of this study was to compare reoperation and revision rates of double plating (DP), single plating using a lateral locking plate (SP), or distal femoral arthroplasty (DFA) for the treatment of periprosthetic distal femur fractures (PDFFs). Methods. All patients with PDFF primarily treated with DP, SP, or DFA between 2008 and 2022 at a university teaching hospital were included in this retrospective cohort study. The primary outcome was revision surgery for failure following DP, SP, or DFA. Secondary outcome measures included any reoperation, length of hospital stay, and mortality. All basic demographic and relevant implant and injury details were collected. Radiological analysis included fracture classification and evaluation of metaphyseal and medial
Aims. Low-energy distal radius fractures (DRFs) are the most common upper arm fractures correlated with bone fragility. Vitamin D deficiency is an important risk factor associated with DRFs. However, the relationship between DRF severity and vitamin D deficiency is not elucidated. Therefore, this study aimed to identify the correlation between DRF severity and serum 25-hydroxyvitamin-D level, which is an indicator of vitamin D deficiency. Methods. This multicentre retrospective observational study enrolled 122 female patients aged over 45 years with DRFs with extension deformity. DRF severity was assessed by three independent examiners using 3D CT. Moreover, it was categorized based on the AO classification, and the degree of articular and volar cortex
Classification systems for tibial plateau fractures suffer from poor interobserver agreement, and their value in preoperative assessment to guide surgical fixation strategies is limited. For tibial plateau fractures four major characteristics are identified: lateral split fragment, posteromedial fragment, anterior tubercle fragment, and central zone of
Aims. Several previously identified patient-, injury-, and treatment-related factors are associated with the development of nonunion in distal femur fractures. However, the predictive value of these factors is not well defined. We aimed to assess the predictive ability of previously identified risk factors in the development of nonunion leading to secondary surgery in distal femur fractures. Methods. We conducted a retrospective cohort study of adult patients with traumatic distal femur fracture treated with lateral locking plate between 2009 and 2018. The patients who underwent secondary surgery due to fracture healing problem or plate failure were considered having nonunion. Background knowledge of risk factors of distal femur fracture nonunion based on previous literature was used to form an initial set of variables. A logistic regression model was used with previously identified patient- and injury-related variables (age, sex, BMI, diabetes, smoking, periprosthetic fracture, open fracture, trauma energy, fracture zone length, fracture
With an aging population and increase in total knee arthroplasty, periprosthetic distal femur fractures (PDFFs) have increased. The differences between these fractures and native distal femur fractures (NDFF) have not been comprehensively investigated. The purpose of this study was to compare the demographic, fracture, and treatment details of PDFFs compared to NDFFs. A retrospective study of patients ≥ 18 years old who underwent surgical treatment for either a NDFF or a PDFF from 2010 to 2020 at a level 1 trauma center was performed. Demographics, AO/OTA fracture classification, quality of reduction, fixation constructs, and unplanned revision reoperation were compared between PDFF patients and NDFF patients using t-test and Fisher's exact test.
209 patients were identified with 70 patients having a PDFF and 139 patients having a NDFF. Of note, 48% of NDFF had a concomitant fracture of the ipsilateral knee (14%) or tibial plateau (15%). The most common AO/OTA classification for PDFFs was 33A3.3 (71%). NDFFs had two main AO/OTA classifications of 33C2.2 (28%) or 33A3.2. (25%). When controlling for patient age, bone quality, fracture classification, and fixation, the PDFF group had increased revision reoperation rate compared to NDFF (P < 0.05). PDFFs tend to occur in elderly patients with low bone quality, have complete metaphyseal
Femoral shaft fractures are potentially devastating injuries. Despite this, clinical studies of the biomechanics of this injury are lacking. We aimed to clinically evaluate bone behaviour under high and low energy trauma in paediatric, adult and older patients. Single-centre retrospective study identifying all diaphyseal femoral fractures between Feb 2015-Feb 2017. Peri-prosthetic and pathological fractures were excluded. Patients were subdivided into groups 1 (paediatric, <16yo), 2 (adult, 17–55yo) and 3 (older, >55yo) to reflect immature, peak bone age and osteoporotic bone respectively. Chi-Squared analysis assessed significance of bone age to degree of
Gunshot-induced fractures of the proximal femur typically present with severe
Abstract. INTRODUCTION. The anatomic distal femoral locking plate (DF-LCP) has simplified the management of supracondylar femoral fractures with stable knee prostheses. Osteoporosis and
The management of comminuted metaphyseal fractures is a technical challenge and satisfactory outcomes of such fixations often remain elusive. The small articular fragments and bone loss often make it difficult for standard fixation implants for proper fixation. We developed a novel technique to achieve anatomical reduction in multiple cases of comminuted metaphyseal fractures at different sites by employing the cantilever mechanism with the help of multiple thin Kirschner wires augmented by standard fixation implants. We performed a retrospective study of 10 patients with different metaphyseal fractures complicated by
Debate surrounds the optimum operative treatment of periprosthetic distal femoral fractures (PDFFs) at the level of well fixed femoral components; lateral locking plate fixation (LLP-ORIF) or distal femoral replacement (DFR). To determine which attributed the least peri-operative morbidity and mortality we performed a retrospective cohort study of 60 consecutive unilateral PDFFs of Su types II (40/60) and III (20/60) in patients ≥60 years; 33 underwent LLP-ORIF and 27 underwent DFR. The primary outcome measure was reoperation. Secondary outcomes included perioperative complications and functional mobility status. Kaplan Meier survival analysis was performed. Cox multivariable regression analysis identified risk factors for reoperation after LLP-ORIF. Mean length of follow-up was 3.8 years (range 1.0–10.4). One-year mortality was 13% (8/60). Reoperation rate was significantly higher following LLP-ORIF: 7/33 vs 0/27, p=0.008. For the endpoint reoperation, five-year survival was better following DFR: 100% compared to 70.8% (51.8 to 89.8 95%CI) (p=0.006). For the endpoint mechanical failure (including radiographic loosening) there was no difference at 5 years: ORIF 74.5% (56.3 to 92.7); DFR 78.2% (52.3 to 100), p=0.182). Reoperation following LLP-ORIF was independently associated with medial
Our study seeks to determine whether characteristics of radiographs taken post-reduction of a forearm fracture can indicate future risk of refracture or loss of reduction. We hypothesize that reducing forearm fractures too precisely may be counterproductive and provide less benefit than reductions left slightly offset prior to cast immobilization. We conducted a retrospective review of 1079 pediatric patients treated for forearm fractures between January 2014 and September 2021 in a 327 bed regional medical center. Percent fracture displacement, location, orientation,
Treatment of both simple and complex patella fractures is a challenging clinical problem. The aim of this study was to investigate the biomechanical performance of recently developed lateral rim variable angle locking plates versus tension band wiring used for fixation of simple and complex patella fractures. Twelve pairs of human anatomical knees were used to simulate either two-part transverse simple AO/OTA 34C1 or five-part complex AO/OTA 34C3 patella fractures by means of osteotomies, with each fracture model created in six pairs. The complex fracture pattern was characterized by a medial and a lateral proximal fragment, together with an inferomedial, an inferolateral, and an inferior fragment mimicking
Background. In fixation of the fibula in ankle fractures, AO advocate using a lag screw and one-third tubular neutralisation plate for simple patterns. Where a lag screw cannot be placed, bridging fixation is required. A local pilot service evaluation previously identified variance in use of locking plates in all patterns with significant cost implications. The FAIR study aimed to evaluate current practice and implant use across the United Kingdom (UK) and review outcomes and complication rates between different fibula fixation methods. Method. The study was supported by CORNET, the North East trainee research collaborative, and BOTA. Data was collected using REDCap from 22 centres in the UK retrospectively for a one-year period between 1. st. January 2019 and 31. st. December 2019 on injury mechanism, fracture characteristics, comorbidities, fixation and complications. Follow-up data was collected to at least two-years from the time surgery. Results. 1448 ankle fractures which involved fixation of the fibula were recorded; one-third tubular plate was used in 866 (59.8%) cases, a locking plate in 463 (32.0%) cases and other methods in 119 (8.2%) cases. There was significant difference between centres (p<0.001) in implant type used. Other factors associated with implant type were age, diabetes, osteoporosis, open fractures, fracture pattern and the presence of