Advertisement for orthosearch.org.uk
Results 1 - 20 of 172
Results per page:
Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_5 | Pages 55 - 55
1 Apr 2018
Pierrepont J Miller A Bruce W Bare J McMahon S Shimmin A
Full Access

Introduction

Appropriate prosthetic alignment is an important factor in maintaining stability and maximising the performance of the bearing after total hip replacement (THR). With a cementless component, the anteversion of the native femur has been shown to influence the anteversion of the prosthetic stem. However, the extent to which anteversion of a cementless stem can be adjusted from the native anteversion has seldom been reported. The aim of this study was to investigate the difference between native and stem anteversion with two different cementless stem designs.

Method

116 patients had 3-dimensional templating as part of their routine planning for THR (Optimized Ortho, Sydney). 96 patients from 3 surgeons (AS, JB, SM) received a blade stem (TriFit TS, Corin, UK) through a posterior approach. 18 patients received a fully HA-coated stem (MetaFix, Corin, UK) through a posterior approach by a single surgeon (WB). The anteversion of the native femoral neck was measured from a 3D reconstruction of the proximal femur. All patients received a post-operative CT scan which was superimposed onto the pre-op CT scan. The difference between native and achieved stem anteversion was then measured. As surgeons had differing philosophies around target stem anteversion, the differences amongst surgeons were also investigated.


Orthopaedic Proceedings
Vol. 95-B, Issue SUPP_34 | Pages 158 - 158
1 Dec 2013
Reimeringer M Nuño N
Full Access

Introduction. Modeling the press-fit that occurs in Total Hip Arthroplasty (THA) cementless implants is crucial for the prediction of micromotion using finite element analysis (FEA). Some studies investigated the effect of the press-fit magnitude and found a direct influence on the micromotion [1,2]. They assumed in their model that press-fit occurs throughout the prosthesis. However [3] found using computed tomography measurement that only 43% of the stem-bone interfaces is really in contact. The aim of this study is to investigate the press-fit effect at the stem-bone interface on the implant micromotion. Methods. Finite element analysis (FEA) was performed on a Profemur® TL implanted into a Sawbones®. The implant orientation was validated in a previous study [4]. All materials were defined as linear isotropic homogeneous. FEA was carried out for the static loading conditions defined by [5] simulating walking fastly. Frictional contact between the bone and the prosthesis was assumed all along the prosthesis with a coefficient μ set to 0, 63 for the plasma spray (Fig. 1a) and 0,39 for the polished surface (Fig. 1b) [6]. Firstly, FEA was performed without press-fit (Fig. 2a) and then press-fit was simulated with an interference of 0,05 mm [2] between stem and bone in specific areas: superior (Fig. 2b), intermediate (Fig. 2c), inferior (Fig. 2d), and cortical alone (Fig. 2e) and finally over the entire surface in contact with the bone. The press-fit effect at the stem-bone interface on the micromotion was investigated. Measurement of the micromotion was realised on different points located on the plasma spray surface by calculating the difference between the final displacement of the prosthesis and the final displacement of the bone. Results. When press-fit is applied along the entire stem-bone interface, micromotion is lower than 10 μm. In the case when no press fit is simulated, micromotion is in the range of 11 μm and 48 μm. When press-fit is included where only cortical bone is (small areas mid-way proximal and medial part), micromotion is in the range of 17 μm and 30 μm. When the press-fit is included where inferior cancellous bone is (more distal), micromotion is between 9 μm and 38 μm. When the press-fit is included in the intermediate cancellous bone (mid-way), micromotion is between 1 μm and 47 μm. Finally, when press-fit is involved in the superior cancellous bone (more proximal) alone, micromotion is in the range of 4 μm and 12 μm. The results are shown on Fig. 3. Discussion. The maximum stem-bone interface micromotions calculated in this study always remain lower than 50 μm. [7] shows that interfacial micromotion greater than 40 μm produces only partial ingrowth. This indicates that in our study, in all cases investigated the primary stability was not compromised. In general, press-fit increased the primary stability. Our results indicate that press-fit in the proximal area improves widely the primary stability of this prosthesis, especially if the implant is in direct contact with cortical and cancellous bone


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 281 - 281
1 May 2006
Glynn A Connolly P McCormack D O’Byrne J
Full Access

Introduction: Total hip arthroplasty for osteoarthritis secondary to developmental dysplasia of the hip (DDH) is technically difficult due to the abnormal anatomy involved. The use of a modular hip replacement system is advantageous in that its versatility allows for intra-operative adjustment to accommodate for final acetabular position and version.

Aim: The aim of this study was to assess our early results with the S-ROM hip (DePuy), a cementless modular femoral implant.

Methods and materials: We performed 22 total hip replacements on 20 patients with DDH over a three and a half year period. Nineteen patients were female and one was male. Ages ranged from 30 to 59 years (average 38.3 years). Ten patients had had previous osteotomies performed, including two of whom had Ganz periace-tabular osteotomies performed in our centre.

Nine patients had additional acetabular bone grafting with autologous femoral head, two patients had subtrochanteric osteotomy, and another patient had an adductor tenotomy performed at the time of their surgery. Follow-up ranged from 6 to 44 (mean 19.6) months.

Results: Harris hip scores improved from an average of 42 points pre-operatively to 90 points post-operatively. No radiographic evidence of osteolysis was seen around the femoral implant. Two patients required revision of their acetabular components. Both had satisfactory outcomes.

Conclusion: Our early results with the S-ROM femoral prosthesis correlate well with those from other studies involving arthroplasty for DDH. There were no complications related to the use of uncemented prostheses. Modularity makes this implant extremely versatile and easy to use in this complex patient population.


Bone & Joint Open
Vol. 5, Issue 4 | Pages 277 - 285
8 Apr 2024
Khetan V Baxter I Hampton M Spencer A Anderson A

Aims. The mean age of patients undergoing total knee arthroplasty (TKA) has reduced with time. Younger patients have increased expectations following TKA. Aseptic loosening of the tibial component is the most common cause of failure of TKA in the UK. Interest in cementless TKA has re-emerged due to its encouraging results in the younger patient population. We review a large series of tantalum trabecular metal cementless implants in patients who are at the highest risk of revision surgery. Methods. A total of 454 consecutive patients who underwent cementless TKA between August 2004 and December 2021 were reviewed. The mean follow-up was ten years. Plain radiographs were analyzed for radiolucent lines. Patients who underwent revision TKA were recorded, and the cause for revision was determined. Data from the National Joint Registry for England, Wales, Northern Island, the Isle of Man and the States of Guernsey (NJR) were compared with our series. Results. No patients in our series had evidence of radiolucent lines on their latest radiological assessment. Only eight patients out of 454 required revision arthroplasty, and none of these revisions were indicated for aseptic loosening of the tibial baseplate. When compared to data from the NJR annual report, Kaplan-Meier estimates from our series (2.94 (95% confidence interval (CI) 1.24 to 5.87)) show a significant reduction in cumulative estimates of revision compared to all cemented (4.82 (95% CI 4.69 to 4.96)) or cementless TKA (5.65 (95% CI 5.23 to 6.10)). Our data (2.94 (95% CI 1.24 to 5.87)) also show lower cumulative revision rates compared to the most popular implant (PFC Sigma Cemented Knee implant fixation, 4.03 (95% CI 3.75 to 4.33)). The prosthesis time revision rate (PTIR) estimates for our series (2.07 (95% CI 0.95 to 3.83)) were lower than those of cemented cases (4.53 (95% CI 4.49 to 4.57)) from NJR. Conclusion. The NexGen trabecular (tantalum) cementless implant has lower revision rates in our series compared to all cemented implants and other types of cementless implants, and its use in younger patients should be encouraged. Cite this article: Bone Jt Open 2024;5(4):277–285


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_16 | Pages 22 - 22
17 Nov 2023
van Duren B Firth A Berber R Matar H Bloch B
Full Access

Abstract. Objectives. Obesity is prevalent with nearly one third of the world's population being classified as obese. Total knee arthroplasty (TKA) is an effective treatment option for high BMI patients achieving similar outcomes to non-obese patients. However, increased rates of aseptic loosening in patients with a high BMI have been reported. In patients with high BMI/body mass there is an increase in strain placed on the implant fixation interfaces. As such component fixation is a potential concern when performing TKA in the obese patient. To address this concern the use of extended tibial stems in cemented implants or cementless fixation have been advocated. Extend tibial stems are thought to improve implant stability reducing the micromotion between interfaces and consequently the risk of aseptic loosening. Cementless implants, once biologic fixation is achieved, effectively integrate into bone eliminating an interface. This retrospective study compared the use of extended tibial stems and cementless implants to conventional cemented implants in high BMI patients. Methods. From a prospectively maintained database of 3239 primary Attune TKA (Depuy, Warsaw, Indiana), obese patients (body mass index (BMI) >30 kg/m²) were retrospectively reviewed. Two groups of patients 1) using a tibial stem extension [n=162] and 2) cementless fixation [n=163] were compared to 3) a control group (n=1426) with a standard tibial stem cemented implant. All operations were performed by or under the direct supervision of specialist arthroplasty surgeons. Analysis compared the groups with respect to class I, II, and III (BMI >30kg/m², >35 kg/m², >40 kg/m²) obesity. The primary outcome measures were all-cause revision, revision for aseptic loosening, and revision for tibial loosening. Kaplan-Meier survival analysis and Cox regression models were used to compare the primary outcomes between groups. Where radiographic images at greater than 3 months post-operatively were available, radiographs were examined to compare the presence of peri-implant radiolucent lines. Results. The mean follow-up of 4.8, 3.4, and 2.5 years for cemented, stemmed, and cementless groups respectively. In total there were 34 all-cause revisions across all the groups with revision rates of 4.55, 5.50, and 0.00 per 1000-implant-years for cemented, stemmed, and cementless groups respectively. Survival Analysis did not show any significant differences between the three groups for all-all cause revision. There were 6 revisions for aseptic loosening (5 tibial and 1 femoral); all of which were in the standard cemented implant group. In contrast there were no revisions in the stemmed or cementless implant groups, however, this was not significant on survival analysis. Analysis looking at class I, II, and III obesity also did not show any significant differences in survival for all cause revision or aseptic loosening. Conclusion. This retrospective analysis showed that there were no revisions required for aseptic loosening when either a cemented stemmed or cementless implant were used in obese patients. These findings are in line with other studies showing that cementless fixation or extended stem implants are a reasonable option in obese patients who represent an increasing cohort of patients requiring TKR. Declaration of Interest. (b) declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research reported:I declare that there is no conflict of interest that could be perceived as prejudicing the impartiality of the research project


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_16 | Pages 12 - 12
19 Aug 2024
Zagra L Ding B Sciamanna L D'Apolito R
Full Access

This study aimed to verify the hypothesis that an antibiotic loaded hydrogel, defensive antimicrobial coating (DAC), reduces overall complication and infection rates when used for high-risk primary and revision total hip arthroplasty (THA). This was a retrospective study matched cohort study of 238 patients, treated with cementless implants with and without DAC. A sub-group analysis of patients undergoing 2nd stage revision THA for prosthetic joint infection (PJI) was also conducted. Re-infection rates within 2 years, complications necessitating surgical intervention and radiographic analysis for aseptic loosening was assessed. The mean age was 68.3±11.5 years, with 39 (32.8%) Macpherson class A, 64 (53.8%) class B and 16 (13.4%) class C patients. 4 (3.4%) patients in the DAC group developed complications including 1 PJI and 1 delayed wound healing, while 13 (10.9%) patients in the control group developed complications including 5 PJIs and 3 delayed wound healing (p=0.032). PJI rates (p=0.136) and delayed wound healing rates (p=0.337) were not statistically significant. For 2nd stage revision THA for PJI there were 86 patients in the DAC group and 45 in the control group. 1 (1.2%) patient in the DAC group developed complications with no recurrences of infection or delayed wound healing, while 10 (22.2%) patients in the control group developed complications including 4 recurrent PJI and 1 delayed wound healing (p=0.003). Recurrent PJI rates were statistically significant (p=0.005) while delayed wound healing rates were not (p=0.165). Patients treated with DAC also had lower rates of aseptic loosening (0% vs 6.7%; p=0.015). Antibiotic impregnated hydrogel coatings on cementless implants showed decreased complication rates after complex primary or revision THA. In 2nd stage revision THA for PJI, it was associated with reduced risk of re-infection and aseptic loosening


Bone & Joint Open
Vol. 2, Issue 1 | Pages 48 - 57
19 Jan 2021
Asokan A Plastow R Kayani B Radhakrishnan GT Magan AA Haddad FS

Cementless knee arthroplasty has seen a recent resurgence in popularity due to conceptual advantages, including improved osseointegration providing biological fixation, increased surgical efficiency, and reduced systemic complications associated with cement impaction and wear from cement debris. Increasingly younger and higher demand patients are requiring knee arthroplasty, and as such, there is optimism cementless fixation may improve implant survivorship and functional outcomes. Compared to cemented implants, the National Joint Registry (NJR) currently reports higher revision rates in cementless total knee arthroplasty (TKA), but lower in unicompartmental knee arthroplasty (UKA). However, recent studies are beginning to show excellent outcomes with cementless implants, particularly with UKA which has shown superior performance to cemented varieties. Cementless TKA has yet to show long-term benefit, and currently performs equivalently to cemented in short- to medium-term cohort studies. However, with novel concepts including 3D-printed coatings, robotic-assisted surgery, radiostereometric analysis, and kinematic or functional knee alignment principles, it is hoped they may help improve the outcomes of cementless TKA in the long-term. In addition, though cementless implant costs remain higher due to novel implant coatings, it is speculated cost-effectiveness can be achieved through greater surgical efficiency and potential reduction in revision costs. There is paucity of level one data on long-term outcomes between fixation methods and the cost-effectiveness of modern cementless knee arthroplasty. This review explores recent literature on cementless knee arthroplasty, with regards to clinical outcomes, implant survivorship, complications, and cost-effectiveness; providing a concise update to assist clinicians on implant choice. Cite this article: Bone Jt Open 2021;2(1):48–57


Bone & Joint Open
Vol. 5, Issue 5 | Pages 401 - 410
20 May 2024
Bayoumi T Burger JA van der List JP Sierevelt IN Spekenbrink-Spooren A Pearle AD Kerkhoffs GMMJ Zuiderbaan HA

Aims. The primary objective of this registry-based study was to compare patient-reported outcomes of cementless and cemented medial unicompartmental knee arthroplasty (UKA) during the first postoperative year. The secondary objective was to assess one- and three-year implant survival of both fixation techniques. Methods. We analyzed 10,862 cementless and 7,917 cemented UKA cases enrolled in the Dutch Arthroplasty Registry, operated between 2017 and 2021. Pre- to postoperative change in outcomes at six and 12 months’ follow-up were compared using mixed model analyses. Kaplan-Meier and Cox regression models were applied to quantify differences in implant survival. Adjustments were made for patient-specific variables and annual hospital volume. Results. Change from baseline in the Oxford Knee Score (OKS) and activity-related pain was comparable between groups. Adjustment for covariates demonstrated a minimally greater decrease in rest-related pain in the cemented group (β = -0.09 (95% confidence interval (CI) -0.16 to -0.01)). Cementless fixation was associated with a higher probability of achieving an excellent OKS outcome (> 41 points) (adjusted odds ratio 1.2 (95% CI 1.1 to 1.3)). The likelihood of one-year implant survival was greater for cemented implants (adjusted hazard ratio (HR) 1.35 (95% CI 1.01 to 1.71)), with higher revision rates for periprosthetic fractures of cementless implants. During two to three years’ follow-up, the likelihood of implant survival was non-significantly greater for cementless UKA (adjusted HR 0.64 (95% CI 0.40 to 1.04)), primarily due to increased revision rates for tibial loosening of cemented implants. Conclusion. Cementless and cemented medial UKA led to comparable improvement in physical function and pain reduction during the initial postoperative year, albeit with a greater likelihood of achieving excellent OKS outcomes after cementless UKA. Anticipated differences in early physical function and pain should not be a decisive factor in the choice of fixation technique. However, surgeons should consider the differences in short- and long-term implant survival when deciding which implant to use. Cite this article: Bone Jt Open 2024;5(5):401–410


Bone & Joint Research
Vol. 13, Issue 6 | Pages 272 - 278
5 Jun 2024
Niki Y Huber G Behzadi K Morlock MM

Aims. Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model. Methods. Acetabular components (cups) were implanted into 1 mm nominal under-sized cavities in PU foams (15 and 30 per cubic foot (PCF)) using a vibratory implant insertion device and an automated impaction device for single blows. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods. Results. Impaction force was reduced by 89% and 53% for vibratory insertion in 15 and 30 PCF foams, respectively. Both methods positioned the component with polar gaps under 2 mm in 15 PCF foam. However, in 30 PCF foam, the vibratory insertion resulted in a clinically undesirable polar gap of over 2 mm. A higher lever-out moment was achieved with the consecutive single blow insertion by 42% in 15 PCF and 2.7 times higher in 30 PCF foam. Conclusion. Vibratory implant insertion may lower periprosthetic fracture risk by reducing impaction forces, particularly in low-quality bone. Achieving implant seating using vibratory insertion requires adjustment of the nominal press-fit, especially in denser bone. Further preclinical testing on real bone tissue is necessary to assess whether its viscoelasticity in combination with an adjusted press-fit can compensate for the reduced primary stability after vibratory insertion observed in this study. Cite this article: Bone Joint Res 2024;13(6):272–278


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 2 - 2
1 Nov 2021
Delaunay C
Full Access

Aim of this work is to critically analyze the current mandatory trend to adapt femoral cementless implant shape as to allow their use through mini-invasive anterior hip approach (MIS-AA). During decades, designers of cementless stems tried to adapt implant shapes to patient anatomy, that led to various classification systems (straight, curved, anatomic, etc …). Another way to classify cementless stems is according to their longevity, outcome quality and long-term results. This is the goal of the Orthopaedic Data Evaluation Panel (ODEP) that provided in 2017 an approved list of prostheses that meet at least the NICE 10y revision rate standard. In the last available ODEP 2020 issue, the best rating (13y experience “13”, with strong evidence “A” and < 6.5% rev rate “∗”) was achieved by only 10 cementless implant: Mallory-Head®, Taperloc®, Bimetric®, Accolade®, SL-Alloclassic®, Corail®, CLS Spotorno®, Furlong®, Synergy® & Versys Fibermetal®. All 10 are Ti straight tapers with large metaphyseal morphology in particular in Gruen Zone I. All these 10 ODEP 13A∗ cementless stems can universally be implanted through postero-lateral (PL), MIS-PL, lateral & conventional anterior approaches, but not safely through MIS-AA. Conversely, only new short and curved stems can be inserted safely through MIS-AA. Indeed, surgeons who promote MIS-AA cannot routinely use those successful femoral implants classified ODEP 13A∗. Obviously, surgical approach determines the choice of femoral component. Surgeons who promote MIAA can only bet/hope that these new short curved implants with currently very few clinical evidence will reach the same success and longevity that ODEP 13A∗ conventional straight tapers. Only future long-term studies will address that concern


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_12 | Pages 14 - 14
23 Jun 2023
Hooper G Thompson D Frampton C Lash N Sharr J Fulkner D Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMD. 119 patients were randomized to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years comparing the unoperated contralateral femur as a control. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% in the mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. Implant design was shown to impact BMD changes. All stems preserved bone at the metaphyseal level in early follow-up, which theoretically indicates favorable implant fixation. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_2 | Pages 77 - 77
10 Feb 2023
Hooper G Thompson D Lash N Sharr J Faulkner D Frampton C Gilchrist N
Full Access

Femoral stem design affects periprosthetic bone mineral density (BMD), which may impact long term survival of cementless implants in total hip arthroplasty (THA). The aim of this study was to examine proximal femoral BMD in three morphologically different uncemented femoral stems designs to investigate whether one particular design resulted in improved preservation of BMDMethods: 119 patients were randomised to receive either a proximally coated dual taper wedge stem, a proximally coated anatomic stem or a fully coated collarless triple tapered stem. All surgeries were performed via the posterior approach with mobilization on the day of surgery. Dual energy x-ray absorptiometry scans (Lunar iDXA, GE Healthcare, Madison, WI) assessed BMD across the seven Gruen zones pre-operatively, and post-operatively at 6-weeks, 1-year, and 2-years and compared to the unoperated contralateral femur as a control. Patient reported outcome measures of pain, function and health were also included at these corresponding follow-ups. BMD increased in zones one (2.5%), two (17.1%), three (13.0%), five (10%) and six (17.9%) for all stems. Greater preservation of BMD was measured on the lateral cortex (zone 2) for both the dual taper wedge and anatomic stems (p = 0.019). The dual taper wedge stem also demonstrated preservation of BMD in the medial calcar (zone 7) whilst the anatomic and triple taper stem declined in this region, however this was not statistically significant (p = 0.059). BMD decreased on average by 2.1% inthe mid-diaphysis region, distal to the stem tip (zone 4) for all implants. All stems performed equivalently at final follow-up in all patient reported outcome measures. This study demonstrated maintenance of femoral BMD in three different cementless femoral stem designs, with all achieving excellent improvements in patient reported outcomes. There was no significant stress shielding observed, however longer follow-up is required to elucidate the impact of this finding on implant survivorship


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_7 | Pages 129 - 129
4 Apr 2023
Adla P Iqbal A Sankar S Mehta S Raghavendra M
Full Access

Intraoperative fractures although rare are one of the complications known to occur while performing a total hip arthroplasty (THA). However, due to lower incidence rates there is currently a gap in this area of literature that systematically reviews this important issue of complications associated with THA. Method: We looked into Electronic databases including PubMed, Cochrane Central Register of Controlled Trials (CENTRAL), the archives of meetings of orthopaedic associations and the bibliographies of included articles and asked experts to identify prospective studies, published in any language that evaluated intra-operative fractures occurring during total hip arthroplasty from the year 1950-2020. The screening, data extraction and quality assessment were carried out by two researchers and if there was any discrepancy, a third reviewer was involved. Fourteen studies were identified. The reported range of occurrence of fracture while performing hip replacement surgery was found to be 0.4-7.6%. Major risk factors identified were surgical approaches, Elderly age, less Metaphyseal-Diaphyseal Index score, change in resistance while insertion of the femur implants, inexperienced surgeons, uncemented femoral components, use of monoblock elliptical components, implantation of the acetabular components, patients with ankylosing spondylitis, female gender, uncemented stems in patients with abnormal proximal femoral anatomy and with cortices, different stem designs, heterogeneous fracture patterns and toothed design. Intraoperative fractures during THA were managed with cerclage wire, femoral revision, intramedullary nail and cerclage wires, use of internal fixation plates and screws for management of intra operative femur and acetabular fractures. The main reason for intraoperative fracture was found to be usage of cementless implants but planning and timely recognition of risk factors and evaluating them is important in management of intraoperative fractures. Adequate surgical site exposure is critical especially during dislocation of hip, reaming of acetabulum, impaction of implant and preparing the femoral canal for stem insertion. Eccentric and increased reaming of acetabulum to accommodate a larger cup is to be avoided, especially in females and elderly patients as the acetabulum is thinner. However, this area requires more research in order to obtain more evidence on effectiveness, safety and management of intraoperative fractures during THA


Orthopaedic Proceedings
Vol. 106-B, Issue SUPP_6 | Pages 35 - 35
2 May 2024
Robinson M Wong ML Cassidy R Bryce L Lamb J Diamond O Beverland D
Full Access

The significance of periprosthetic fractures about a total hip arthroplasty (THA) is becoming increasingly important. Recent studies have demonstrated post-operative periprosthetic fracture rates are higher amongst cemented polished taper slip (PTS) stem designs compared to collared cementless (CC) designs. However, in the National Joint Registry, the rate of intra-operative periprosthetic femoral fractures (IOPFF) with cementless implant systems remains higher (0.87% vs 0.42%. p <0.001) potentially leading to more post-operative complications. This study identifies the incidence of IOPFF, the fracture subtype and compares functional outcomes and revision rates of CC femoral implants with an IOPFF to CC stems and PTS stems without a fracture. 5376 consecutive CC stem THA, carried out through a posterior approach were reviewed for IOPFF. Each fracture was subdivided into calcar fracture, greater trochanter (GT) fracture or shaft fracture. 1:1:1 matched analysis was carried out to compare Oxford scores at one year. Matching criteria included; sex (exact), age (± 1 year), American Society of Anaesthesiologists (ASA) grade (exact), and date of surgery (± 6 months). Electronic records were used to review revision rates. Following review of the CC stems, 44 (0.8%) were identified as having an IOPFF. Of these 30 (0.6%) were calcar fractures, 11 (0.2%) GT fractures and 3 (0.06%) were shaft fractures. There were no shaft penetrations. Overall, no significant difference in Oxford scores at one year were observed when comparing the CC IOPFF, CC non-IOPFF and PTS groups. There were no CC stems revised for any reason with either a calcar fracture or trochanteric fracture within the period of 8 years follow-up. IOPFF do occur more frequently in cementless systems than cemented. The majority are calcar and GT fractures. These fractures, when identified and managed intra-operatively, do not have worse functional outcomes or revision rates compared to matched non-IOPFF cases


Bone & Joint Research
Vol. 8, Issue 12 | Pages 604 - 607
1 Dec 2019
Konan S Abdel MP Haddad FS

There is continued debate as to whether cemented or cementless implants should be utilized in particular cases based upon chronological age. This debate has been rekindled in the UK and other countries by directives mandating certain forms of acetabular and femoral component fixation based exclusively on the chronological age of the patient. This editorial focuses on the literature-based arguments to support the use of cementless total hip arthroplasty (THA), while addressing potential concerns surrounding safety and cost-effectiveness. Cite this article: Bone Joint Res. 2019;8(12):604–607


Bone & Joint Open
Vol. 3, Issue 7 | Pages 589 - 595
1 Jul 2022
Joo PY Chen AF Richards J Law TY Taylor K Marchand K Clark G Collopy D Marchand RC Roche M Mont MA Malkani AL

Aims. The aim of this study was to report patient and clinical outcomes following robotic-assisted total knee arthroplasty (RA-TKA) at multiple institutions with a minimum two-year follow-up. Methods. This was a multicentre registry study from October 2016 to June 2021 that included 861 primary RA-TKA patients who completed at least one pre- and postoperative patient-reported outcome measure (PROM) questionnaire, including Forgotten Joint Score (FJS), Knee Injury and Osteoarthritis Outcomes Score for Joint Replacement (KOOS JR), and pain out of 100 points. The mean age was 67 years (35 to 86), 452 were male (53%), mean BMI was 31.5 kg/m. 2. (19 to 58), and 553 (64%) cemented and 308 (36%) cementless implants. Results. There were significant improvements in PROMs over time between preoperative, one- to two-year, and > two-year follow-up, with a mean FJS of 17.5 (SD 18.2), 70.2 (SD 27.8), and 76.7 (SD 25.8; p < 0.001); mean KOOS JR of 51.6 (SD 11.5), 85.1 (SD 13.8), and 87.9 (SD 13.0; p < 0.001); and mean pain scores of 65.7 (SD 20.4), 13.0 (SD 19.1), and 11.3 (SD 19.9; p < 0.001), respectively. There were eight superficial infections (0.9%) and four revisions (0.5%). Conclusion. RA-TKA demonstrated consistent clinical results across multiple institutions with excellent PROMs that continued to improve over time. With the ability to achieve target alignment in the coronal, axial, and sagittal planes and provide intraoperative real-time data to obtain balanced gaps, RA-TKA demonstrated excellent clinical outcomes and PROMs in this patient population. Cite this article: Bone Jt Open 2022;3(7):589–595


Orthopaedic Proceedings
Vol. 103-B, Issue SUPP_14 | Pages 25 - 25
1 Nov 2021
Alpaugh K Chiu Y Zlotnicki J Bendich I Della Valle A Bostrom M Gausden E
Full Access

Known risk factors for early periprosthetic femur fracture (PFF) following total hip arthroplasty (THA) include poor bone quality, surgical approach and cementless implants. The association between femoral component size and alignment and the risk of early PFF is not well described. We evaluated radiographic parameters of femoral component sizing and alignment as risk factors for early PFF. From 16,065 primary cementless THA, we identified 66 cases (0.41%) of early PFF (<90 days from index THA) at a single institution between 2016–2020. The stem was unstable and revised in all cases. We matched 60 cases of early PFFs (2:1) to 120 controls based on femoral component model, offset, surgical approach, age, BMI, and sex. Mean age was 67 years; 60% were female. Radiographic assessment of preoperative bone morphology and postoperative femoral component parameters including stem alignment, metaphyseal fill, and medial congruence with the calcar. A multivariable logistic regression was built to identify radiographic risk factors associated with early PPF. Markers of poor preoperative bone quality including canal calcar ratio (p=0.003), canal flare index (p<0.001), anteroposterior canal bone ratio (CBR) (p<0.001) and lateral CBR (p<0.001) were statistically associated with PFF. Valgus alignment (23% versus 12%) (p<0.001) was more prevalent in the PFF group compared to controls, as well as varus alignment of the implant (57% versus 43%). Distance between the medial aspect of the implant and the calcar was greater in cases of PFF (2.5 mm versus 1.4 mm) (p<0.001). Multivariate analysis demonstrated that valgus implant alignment (Odds Ratio (OR) 5) and medial implant-calcar incongruity (OR 2) increased the risk of early PFF. Medial implant-calcar incongruity and valgus alignment of the femoral component were risk factors for early PFF following cementless THA after controlling for age, sex, BMI, approach, proximal femoral morphology, and implant design


Bone & Joint Research
Vol. 9, Issue 7 | Pages 402 - 411
1 Aug 2020
Sanghani-Kerai A Coathup M Brown R Lodge G Osagie-Clouard L Graney I Skinner J Gikas P Blunn G

Aims. For cementless implants, stability is initially attained by an interference fit into the bone and osteo-integration may be encouraged by coating the implant with bioactive substances. Blood based autologous glue provides an easy, cost-effective way of obtaining high concentrations of growth factors for tissue healing and regeneration with the intention of spraying it onto the implant surface during surgery. The aim of this study was to incorporate nucleated cells from autologous bone marrow (BM) aspirate into gels made from the patient’s own blood, and to investigate the effects of incorporating three different concentrations of platelet rich plasma (PRP) on the proliferation and viability of the cells in the gel. Methods. The autologous blood glue (ABG) that constituted 1.25, 2.5, and 5 times concentration PRP were made with and without equal volumes of BM nucleated cells. Proliferation, morphology, and viability of the cells in the glue was measured at days 7 and 14 and compared to cells seeded in fibrin glue. Results. Overall, 2.5 times concentration of PRP in ABG was capable of supporting the maximum growth of cells isolated from the BM aspirate and maintain their characteristics. Irrespective of PRP concentration, cells in ABG had statistically significantly higher viability compared to cells in fibrin glue. Conclusion. In vitro this novel autologous gel is more capable of supporting the growth of cells in its structure for up to 14 days, compared to commercially available fibrin-based sealants, and this difference was statistically significant. Cite this article: Bone Joint Res 2020;9(7):402–411


Orthopaedic Proceedings
Vol. 100-B, Issue SUPP_12 | Pages 29 - 29
1 Oct 2018
Lawrie CM Schwabe M Pierce A Barrack RL
Full Access

Introduction. Cemented total knee arthroplasty (TKA) remains the gold standard with survivorship above 90% at greater than 10 years postoperatively. However, with younger, heavier, more active patients undergoing TKA at an increasing rate, cementless implants have the appeal of potential for improved implant fixation longevity and decreased rates of aseptic loosening. The cementless implants are more expensive than their cemented counterparts such that implant costs may create a barrier to utilization. However, such comparisons fail to consider the unavoidable additional costs of cementing, including the cost of operating room time, cement and cementing accessories. The purpose of this study is to compare the actual cost of cemented and cementless TKA. Methods. The TKA cost calculation included the cost of operative time, implants, cement and cementing accessories. The difference in operative time between cemented and cementless TKA was determined from a previously published study of 100 TKAs performed using a cemented (55) or press fit (45) implant of the same design performed at a single institution by four fellowship trained arthroplasty surgeons. The decision to use cemented or cementless design in these patients was made based on patient bone quality intraoperatively. Operative time was compared between groups using a Student's two-tailed T-test. The cost of operating room time was based on estimates in the recent literature. The cost of cement and cementing accessories was estimated based on publically available market data. The cost of implants was estimated from institutional data for multiple companies. Results. The cost comparison between cemented and cementless total knee arthroplasty is summarized in Table 1. Mean operative time for cemented TKA was 14.3 minutes longer than for cementless TKA (94.7 + 15.2 vs. 80.4 + 15.7, p<0.01). The estimated cost of one minute of operating room time in the literature ranges from $30 to $60. For our analysis, we used an estimate of $36 per minute obtained from a recently published multi-center study. This resulted in an average operating room time cost $3406 for cemented and $2894 for cementless TKA. Antibiotic cement costs an average of $250 per bag and antibiotic-free cement costs an average of $75 per bag. Cement mixing techniques vary across surgeons. Approximately 95% use a vacuum system and 5% use a mixing bowl. The cost of vacuum systems ranges from $80 for an enclosed bowl to $125 for a vacuum system that can be directly connected to a cement gun. The cost of a plastic mixing bowl and spatula is $20. The cost of the disposables from a cement injection kit is $25. The average cost of a primary TKA implant, including femoral, tibial and polyethylene liner components, is $3530 for cemented and $4659 for cementless designs. Patellar resurfacing is not routinely used at our institution and therefore was not included in implant cost. Based on our calculations, the average cost of a cementless TKA is $7553. Using the cheapest cementing technique with 2 bags of plain cement and a manual mixing bowl with spatula, the cost of a cemented TKA $7114. Using the most expensive cementing technique with 2 bags of antibiotic cement and a cement gun compatible vacuum mixer, the cost of a cemented TKA is $7564. Conclusion. Cemented TKA remains the gold standard and still accounts for most procedures. Cementless TKA is increasing in utilization and may decrease the rate of aseptic loosening, especially in the rapidly growing young, active population undergoing TKA. Although cementless implants remain more expensive than cemented implants at most institutions, the actual overall cost of the two procedures is similar if operative time, cement and cementing accessories are considered. For any figures or tables, please contact authors directly


Orthopaedic Proceedings
Vol. 105-B, Issue SUPP_9 | Pages 74 - 74
17 Apr 2023
Theodoridis K Hall T Munford M Van Arkel R
Full Access

The success of cementless orthopaedic implants relies on bony ingrowth and active bone remodelling. Much research effort is invested to develop implants with controllable surface roughness and internal porous architectures that encourage these biological processes. Evaluation of these implants requires long-term and costly animal studies, which do not always yield the desired outcome requiring iteration. The aim of our study is to develop a cost-effective method to prescreen design parameters prior to animal trials to streamline implant development and reduce live animal testing burden. Ex vivo porcine cancellous bone cylinders (n=6, Ø20×12mm) were extracted from porcine knee joints with a computer-numerically-controlled milling machine under sterile conditions within 4 hours of animal sacrifice. The bone discs were implanted with Ø6×12mm additive manufactured porous titanium implants and were then cultured for 21days. Half underwent static culture in medium (DMEM, 10% FBS, 1% antibiotics) at 37°C and 5% CO. 2. The rest were cultured in novel high-throughput stacked configuration in a bioreactor that simulated physiological conditions after surgery: the fluid flow and cyclic compression force were set at 10ml/min and 10–150 N (1Hz,5000 cycles/day) respectively. Stains were administered at days 7 and 14. Samples were evaluated with widefield microscopy, scanning electron microscopy (SEM) and with histology. More bone remodelling was observed on the samples cultured within the bioreactor: widefield imaging showed more remodelling at the boundaries between the implant-bone interface, while SEM revealed immature bone tissue integration within the pores of the implant. Histological analysis confirmed these results, with many more trabecular struts with new osteoid formation on the samples cultured dynamically compared to static ones. Ex vivo bone can be used to analyse new implant technologies with lower cost and ethical impact than animal trial. Physiological conditions (load and fluid flow) promoted bone ingrowth and remodelling