Aims. In metal-on-metal (MoM) hip arthroplasties and resurfacings, mechanically induced corrosion can lead to elevated serum metal ions, a local inflammatory response, and formation of pseudotumours, ultimately requiring revision. The size and diametral clearance of anatomical (ADM) and modular (MDM) dual-mobility polyethylene
Background. Published simulator studies for metal/UHMWPE
Aims. The rate of dislocation when traditional single bearing implants are used in revision total hip arthroplasty (THA) has been reported to be between 8% and 10%. The use of dual mobility
In metal-on-metal (MoM) hip replacements or resurfacings, mechanical induced corrosion can lead to a local inflammatory response, pseudo tumours and elevated serum metal ions, requiring revision surgery. The size and diametral clearance of Anatomic (ADM) and Modular (MDM) Dual Mobility
Expectations for ceramic-on-metal (COM)
Dual-mobility (DM)
Introduction. Previous registry studies of ceramic-on-polyethylene (C-PE) and ceramic-on-ceramic (COC) have focused on revision outcomes following primary surgery. Less is known about the effect of ceramic
Introduction and Aims. There are many surgical, implant design and patient factors that should be considered in preclinical testing of hip replacement which are not being considered in current standards. The aim of this study was to develop a preclinical testing method that consider surgical positioning, implant design and patient factors and predict the occurrence and severity of edge loading under the combination of such conditions. Then, assess the safety and reliability of the implant by predicting the wear, deformation and damage of the implant
Introduction. Previous studies of ceramic-on-polyethylene (C-PE) and ceramic-on-ceramic (COC) hip
Introduction. Looking for optimal solutions to wear risks evident in total hip arthroplasty (THA), silicon nitride ceramic
Acetabular rim damge due to rim impingement is frequently found on retrievals and may be associated with increased wear and contact stresses, instability, and implant loosening of total hip replacement devices. Large X3
Objectives. Third-body wear is believed to be one trigger for adverse results
with metal-on-metal (MOM)
Background. The CoCrMo large
Introduction. Are there really ‘conventional’
Introduction. Alternative
Introduction. Dislocation is one of the major factors for revision surgery. Current literature states that the usage of larger bearing couples (> 36 mm) have the potential of reducing the risk of dislocation. Smaller ceramic-on-ceramic bearing couples (< 36 mm) have demonstrated very low wear rates. But does the wear behaviour change with increasing diameter? Therefore, the aim of this study was to compare wear rates of larger ceramic-on-ceramic bearing couples for total hip arthroplasty. Materials and Methods. Wear tests according to ISO 14242 with 36, 40 and 44 mm zirconia platelet toughened alumina (ZPTA)
The extension of THR to younger and more demanding patients implies the need of
Summary Statement. The frictional torque of ceramic-on-ceramic
Introduction and Aims. The 21. st. Century has seen ceramic
Young patients are at increased risk of revision after primary THA (THA). The bearing surface may be of importance for the longevity of the joint. We aimed to compare the risk of revision of primary stemmed cementless THA with MoM and CoC with metal-on-highly-crosslinked-polyethylene (MoXLP)