header advert
Results 1 - 2 of 2
Results per page:
Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 509 - 509
1 Sep 2012
Thomas G Hossain M Monk A Gill H Glyn-Jones S Andrew J Murray D Beard D Epos Group N
Full Access

Introduction

Malalignment of some designs of stem is associated with an increased risk of aseptic loosening and revision. We investigated whether the alignment of the cemented polished, double-taper design adversely affected outcome, in a multicentre prospective study.

Methods

A multicentre prospective study of 1189 total hip replacements was undertaken to investigate whether there is an association between surgical outcome and femoral stem alignment. All patients underwent a primary THR with the Exeter femoral stem (Stryker Howmedica Osteonics, Mahwah, NJ) and a variety of acetabular components. The primary outcome measure was the Oxford hip score (OHS) and change in OHS at five years. Secondary outcomes included rate of dislocation and revision. Radiographic evaluation of the femoral component was also undertaken. The long axis of the Exeter femoral component and the long axis of the femoral canal were located, and the angle at the point of intersection measured. The cementing quality was determined as defined by Barrack et al. Radiolucent lines at the cement-stem and cement-bone interface in the five year radiographs were defined using the zones described by Gruen et al. Subsidence was measured as the vertical dimension of the radiolucency craniolateral to the shoulder of the stem in Gruen zone 1 as described by Fowler et al. Cement fractures were recorded.


Orthopaedic Proceedings
Vol. 94-B, Issue SUPP_XXXVII | Pages 584 - 584
1 Sep 2012
Grammatopoulos G Thomas G Pandit H Glyn-Jones S Gill H Beard D Murray D
Full Access

INTRODUCTION

The introduction of hard-on-hard bearings and the consequences of increased wear due to edge-loading have renewed interest in the importance of acetabular component orientation for implant survival and functional outcome following hip arthroplasty. Some studies have shown increased dislocation risk when the cup is mal-oriented which has led to the identification of a safe-zone1. The aims of this prospective, multi-centered study of primary total hip arthroplasty (THA) were to: 1. Identify factors that influence cup orientation and 2. Describe the effect of cup orientation on clinical outcome.

METHODS

In a prospective study involving seven UK centers, patients undergoing primary THA between January 1999 and January 2002 were recruited. All patients underwent detailed assessment pre-operatively as well as post-op. Assessment included data on patient demographics, clinical outcome, complications and further surgery/revision. 681 primary THAs had adequate radiographs for inclusion. 590 hips received cemented cups. The primary functional outcome measure of the study was the change between pre-operative and at latest follow up OHS (OHS). Secondary outcome measures included dislocation rate and revision surgery. EBRA was used to determine acetabular inclination and version.

The influence of patient's gender, BMI, surgeon's grade and approach on cup orientation was examined. Four different zones tested as possibly ± (Lewinnek Zone, Callanan's described zone and zones ± 5 and ±10 about the study's mean inclination and anteversion) for a reduced dislocation risk and an optimal functional outcome.