header advert
Results 61 - 66 of 66
Results per page:
Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 414 - 414
1 Jul 2010
Patel S Hossain FS Paton B Haddad FS
Full Access

Purpose: To determine if a multi-modal programme including non-operative measures of physiotherapy and education can improve the symptoms of osteoarthritis of the knee.

Methods/Results: 72 patients with osteoarthritis of the knee confirmed on radiographic or arthroscopic evidence were referred over a 13 month period (April 2007 – May 2008) for a lower limb programme. The programme consisted of 12 classes over 6 weeks of group physiotherapy and included education on osteoarthritis, diet and exercise.

The total number of knees affected was 98. The mean number of compartments affected was 1.2 with the medial and patellofemoral compartment most affected. The mean number of classes attended was 8.3. Pre-intervention, the mean WOMAC score was 64.7 and the mean Oxford knee score was 31.9. Post-intervention at a mean follow up of 12 months (range 7 – 22 months), the mean WOMAC score was 29.4 and the mean Oxford knee score 22.4. The change in scores following intervention was statistically significant (p < 0.05). Of the cohort, 9 patients were subsequently offered or went on to have knee joint arthroplasty.

Conclusions: At 12 months, a multi-modal programme consisting of non-operative interventions has an excellent impact upon osteoarthritis of the knee with improved patient reported scores. This modality should be considered for all patients with mild to moderate osteoarthritis in whom surgical options are not otherwise indicated. Further work is required to see which components most influenced patients’ outcomes, the impact of education and group classes on maintaining physiotherapy exercises in the long term, the benefits conferred even for those patients who subsequently undergo joint arthroplasty, and whether referral to the programme from a primary care setting will lower the number of referrals of knee osteoarthritis to orthopaedic units which are ultimately managed without surgical intervention.


Orthopaedic Proceedings
Vol. 92-B, Issue SUPP_III | Pages 407 - 407
1 Jul 2010
Hossain FS Patel S Tahmassebi J Haddad FS
Full Access

Aim: To ascertain if a medial rotation platform knee replacement design (MRK; Finsbury Orthopaedics) exhibits improved range of motion (ROM) and functional outcome compared to a conventional single radius condylar knee replacement system (PFC Sigma; Depuy) at one year.

Methods: Eighty patients undergoing total knee arthroplasty(TKA) were prospectively randomised and allocated to either receive the MRK or PFC Sigma pros-thesis. Patients were blinded to the choice of implant. Follow-up clinical and radiological evaluations were carried out by a single clinician so as to avoid interob-server error. Validated patient based scores including the Total Knee Function Questionnaire (TKFQ) were used to assess patient function.

Results: The average ROM in the MRK group was 108.53°. In the PFC Sigma group it was 94.16°. Statistical significance was demonstrated between the two groups.

The MRK group showed superior results in the TKFQ score which assesses activities of daily living as well as recreational and sporting activities. The movement and lifestyle component of the TKFQ, and the Knee Society Score were better in the MRK group with statistical significance.

No difference was demonstrated between the two groups with respect to radiological analysis, WOMAC Knee, Oxford Knee and SF-36 scores.

6 out of 40 patients in the MRK group compared to 5 out of 40 patients in the PFC group said that they had forgotten about their TKA at one year.

Conclusions: The medial rotation platform design confers increased ROM at one year with an associated benefit in movement and lifestyle and resultant patient satisfaction.


Orthopaedic Proceedings
Vol. 90-B, Issue SUPP_III | Pages 549 - 549
1 Aug 2008
Rayan F Dodd M Haddad FS
Full Access

Introduction: The incidence of post-operative peri-prosthetic fractures is increasing. This is a consequence of the larger number of revision cases being undertaken, the increase in the use of cementless implants and a number of patients who develop undetected osteolysis as a result of poor follow up. The Vancouver classification has been shown to be a valid and reliable method for determining the configuration of periprosthetic fractures. This is essential in directing the further management of periprosthetic fractures appropriately.

Methods: We have revalidated this classification system independently from the original authors at our institution. The radiographs from 30 patients with peri-prosthetic fractures were reviewed by 6 expert consultant surgeons, 6 non-experts at registrar level and 6 medical students, who had received no specialist training in this area, in order to assess intra and inter-observer reliability and reproducibility. Each observer read the radiographs on 2 separate occasions and classified the fracture according to its type (A, B1, B2, B3, and C).

Results: The results were subjected to weighted κ analysis and were: Intraobserver agreement 0.72 for experts,0.68 for non experts and 0.61 for medical students. Interobserver agreement was 0.63 for the first reading and 0.67 for the second reading. Validity analysis showed a κ value of 0.79 (substantial agreement).

Discussion: Our results confirm the reliability and reproducibility of this classification system. In addition we have shown that substantial agreement can even be found between individuals with no specialist training. This is a classification system that can be used by non-experts, between centres and across continents.


Orthopaedic Proceedings
Vol. 88-B, Issue SUPP_II | Pages 257 - 257
1 May 2006
Wardle NS Lee JKL Haddad FS Blunn GW
Full Access

Background And Aims: Total knee replacements provide a cost effective treatment for painful joint conditions such as osteoarthritis. Their long term performance is governed by ultra-high molecular weight polyethylene (UHMWPE) wear which produces wear debris and leads to osteolysis and aseptic loosening of the implant. Using a new material which is more scratch resistant than cobalt chrome it is hoped to reduce wear of UHMWPE and its subsequent complications.

Methods: Two total knee replacements made from cobalt chrome and two of oxidised zirconium were wear tested in a knee simulator. Surface roughness data from the femoral components was collected. Gravimetric and volumetric wear of the polyethylene inserts was measured. SEM analysis of the surfaces was also performed.

Results: Oxidised zirconium is significantly more scratch resistant than CoCr; Ra (mean average roughness) of 0.7μm compared to 0.43μm (p< < 0.01) at end of test, and confirmed by SEM analysis. This was accompanied by a 4 fold reduction in wear of UHMWPE 49.60mg to 12.48mg (p=0.02). Barium sulphate particles were found to be embedded in the surface of the CoCr implants.

Summary And Conclusions: Oxidised zirconium leads to a reduction in wear of UHMWPE due to its increased resistance to third body wear. It has the potential to increase the longevity of total knee replacements by reducing UHMWPE related complications.


Orthopaedic Proceedings
Vol. 86-B, Issue SUPP_I | Pages 78 - 78
1 Jan 2004
Patel RV Stygall J Harrington J Harrison MG Newman S Haddad FS
Full Access

Aims: To quantify the intraoperative cerebral microemboli load during primary total hip arthroplasty (THA) using transcranial Doppler ultrasound and to investigate whether a patent foramen ovale influences cerebral embolic load in general. The timing of the microemboli will be related to certain surgical activities to determine if a specific relationship exists.

Methods: Patients undergoing primary THA, with no history of stroke, TIA, ongoing CNS disease or alcoholism were included. All operations were carried out under a standardised general anaesthetic and performed by two consultant orthopaedic surgeons. Microemboli load was recorded, using transcranial Doppler ultrasound (TCD), onto VHS tape for subsequent playback and analysis. Patent foramen ovale detection was performed using bolus intravenous injection of agitated saline followed by valsalva manoeuvre technique and TCD. Timing of specific surgical steps was recorded for each operation and emboli load calculated for that period.

Results: 25 THA patients were studied (18 females, 7 males) 16 right and 9 left THA’s were performed. Cerebral microembolisation occurred in 10 patients (40%). Mean microembolic load was 5.52 per patient (range = 0–83). PFO was detected in 8 patients (32%). 37.5% of PFO positive patients displayed cerebral microemboli. However, 41.1% of PFO negative patients also displayed microemboli intraoperatively.

Insertion of the femoral component was associated with generating a larger microembolic load than the other phases of the operation.

Conclusion: Intraoperative cerebral microembolisation occurs in a significant proportion of patients during total hip arthroplasty. The presence of a patent foramen ovale does not appear to influence the incidence microemboli intraoperatively. Specific surgical activities are associated with generating greater embolic loads. These questions will be comprehensively assessed in the larger study currently underway..


Orthopaedic Proceedings
Vol. 85-B, Issue SUPP_I | Pages 61 - 61
1 Jan 2003
Saksena J Haddad FS Muirhead-Allwood SK
Full Access

Introduction: An increasing number of patients present for revision hip replacement with severe bone loss. The results of cemented revision in these cases are poor. This study was conducted to determine the medium term clinical and radiological outcome of 50 consecutive revision hip replacements performed using custom femoral stems.

Materials and Method: 50 consecutive hips (49 patients) performed by the senior author between 1992 and 1995 were identified. The indications for revision were aseptic loosening in 42 cases, infection in 7 cases (6 of which were revised using a two-stage technique), and dislocation in one case. The stems are manufactured on the basis of standardised measurement films using specially developed software. The design includes proximal macrogrooves with hydroxyapatite coating, an anterior flare, a lateral flare and a collar. The average follow up was 88.4 months (range 12–111 months). All patients were evaluated radiologically and using Harris, Oxford and WOMAC hip scores.

Results: The patients were assessed by an independent observer. All had severe bone loss according to AAOS and Paprosky classifications. 5 patients died due to causes unrelated to their hip replacement, 5 were lost to follow up or did not respond to questionnaires sent. The remaining patients had average preoperative scores of HHS 40.8 (range 8–87), Oxford 43.5 (range18–56) and WOMAC 82.5 (range 40–120) and had improved to HHS 74.4 (range 19–99), Oxford 25.5(range 12–51) and WOMAC 43.8 (range 13–89).

Conclusions: The use of customised revision stems allows the implant to be tailored to the patient’s bone stock and femoral anatomy. This technique avoids the massive inventory of implants and trials needed for highly modular revision systems, but nevertheless leads to excellent bone implant apposition and interface stability. The clinical results are excellent at medium term review, and the survivorship compares very favourably with other revision series.