header advert
Results 21 - 40 of 64
Results per page:
Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 65 - 65
1 Mar 2017
Vasarhelyi E Petis S Lanting B Howard J
Full Access

Introduction

Total hip arthroplasty (THA) is the most effective treatment modality for severe arthritis of the hip. Patients report excellent clinical and functional outcomes following THA, including subjective improvement in gait mechanics. However, few studies in the literature have outlined the impact of THA, as well as surgical approach, on gait kinetics and kinematics.

Purpose

The purpose of this study was to determine the impact of surgical approach for THA on quantitative gait analysis.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 10 - 10
1 Mar 2017
Sisko Z Teeter M Lanting B Howard J McCalden R Vasarhelyi E
Full Access

Purpose

Previous retrieval studies demonstrate increased tibial baseplate roughness leads to higher polyethylene backside wear in total knee arthroplasty (TKA). Micromotion between the polyethylene backside and baseplate is affected by the locking mechanism design and can further increase backside wear. This study's purpose was to examine modern locking mechanisms influence, in the setting of both polished and non-polished tibial baseplates, on backside tibial polyethylene damage and wear.

Methods

Five TKA models were selected with different tibial baseplate and/or locking mechanism designs. Six retrieval tibial polyethylenes from each TKA model were matched based on time in vivo (TIV), age at TKA revision, BMI, gender, number of times revised, and revision reason. Two observers visually assessed each polyethylene. Primary outcomes were visual damage scores, individual visual damage modes, and linear wear rates determined on micro-computed tomography (micro-CT) scan in mm/year. Demographics were compared by one-way ANOVA. Damage scores, damage modes, and linear wear were analyzed by the Kruskal-Wallis test and Dunn's multiple comparisons test.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 46 - 46
1 Mar 2017
Teeter M Howard J Vasarhelyi E Yuan X McCalden R Naudie D
Full Access

Background

Patient specific instrumentation (PSI) for total knee replacement (TKR) has demonstrated mixed success in simplifying the operation, reducing its costs, and improving limb alignment. Evaluation of PSI with tools such as radiostereometric analysis (RSA) has been limited, especially for cut-through style guides providing mechanical alignment. The primary goal of the present study was to compare implant migration following TKR using conventional and PSI surgical techniques, with secondary goals to examine whether the use of PSI reduces operative time, instrumentation, and surgical waste.

Methods

The study was designed as a prospective, randomized controlled trial of 50 patients, with 25 patients each in the PSI and conventional groups, powered for the RSA analysis. Patients in the PSI group received an MRI and standing 3-foot x-rays to construct patient-specific cut-through surgical guides for the femur and tibia with a mechanical alignment. All patients received the same posterior-stabilized implant, with marker beads inserted in the bone around the implants to enable RSA imaging. Intraoperative variables such as time, number of instrumentation trays used, and mass of surgical waste were recorded. Patients underwent supine RSA exams at multiple time points (2&6 weeks, 3&6 months and yearly) with 6 months data currently available. Migration of the tibial and femoral components was calculated using model-based RSA software. WOMAC, SF-12, EQ5D, and UCLA outcome measures were recorded pre-operatively and post-operatively.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 47 - 47
1 Mar 2017
Teeter M Perry K Yuan X Howard J Lanting B
Full Access

Background

Surgeons generally perform total knee replacement using either a gap balancing or measured resection approach. In gap balancing, ligamentous releases are performed first to create an equal joint space before any bony resections are performed. In measured resection, bony resections are performed first to match anatomical landmarks, and soft tissue releases are subsequently performed to balance the joint space. Previous studies have found a greater rate of coronal instability and femoral component lift-off using the measured resection technique, but it is unknown how potential differences in loading translate into component stability and fixation.

Methods

Patients were randomly assigned at the time of referral to a surgeon performing either the gap balancing or measured resection technique (n = 12 knees per group). Both groups received an identical cemented, posterior-stabilized implant. At the time of surgery, marker beads were inserted in the bone around the implants to enable radiostereometeric analysis (RSA) imaging. Patients underwent supine RSA exams at 0–2 weeks, 6 weeks, 3 months, 6 months, and 12 months. Migration of the tibial and femoral components including maximum total point motion (MTPM) was calculated using model-based RSA software. Knee Society Scores were also recorded for each group.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_6 | Pages 66 - 66
1 Mar 2017
MacLean C Lanting B Vasarhelyi E Naudie D McAuley J Howard J McCalden R MacDonald S
Full Access

Background

The advent of highly cross-linked polyethylene has resulted in improved wear rates and reduced osteolysis with at least intermediate follow-up when compared to conventional polyethylene. However, the role of alternative femoral head bearing materials in decreasing wear is less clear. The purpose of this study was to determine in-vivo polyethylene wear rates across ceramic, Oxinium, and cobalt chrome femoral head articulations.

Methods

A review of our institutional database was performed to identify patients who underwent a total hip arthroplasty using either ceramic or oxidized zirconium (Oxinium) femoral head components on highly cross-linked polyethylene between 2008 and 2011. These patients were then matched on implant type, age, sex and BMI with patients who had a cobalt chrome bearing implant during the same time period. RSA analysis was performed using the center index method to measure femoral head penetration (polyethylene wear). Secondary quality of life outcomes were collected using WOMAC and HHS Scores. Paired analyses were performed to detect differences in wear rate (mm/year) between the cobalt chrome cohorts and their matched ceramic and Oxinium cohorts. Additional independent group comparisons were performed by analysis of variance with the control groups collapsed to determine wear rate differences between all three cohorts.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 49 - 49
1 Feb 2017
Huey V Brenkel I Chang C Clatworthy M Hamilton W Howard J Kantor S Lesko J Nunley R Whittaker J Verdonk P
Full Access

Introduction

With the introduction of new technology in orthopaedics, surgeons must balance anticipated benefits in patient outcomes with challenges or complications associated with surgical learning curve for the technology. The purpose of this study was to determine whether the surgeon learning curve with a new multi-radius primary TKA system (primary TKA implant and instruments) designed for surgical team ease would impact clinical outcomes, surgical time and complications.

Materials & Methods

From November 2012 to July 2015, 2369 primary TKAs were prospectively enrolled in two multicenter studies across 50 sites in 14 countries with a new knee system (ATTUNE®) evenly balanced across four configurations: cruciate retaining or posterior stabilised with either fixed bearing or rotating platform (CRFB, CRRP, PSFB, PSRP). 2261 knees had a <1 year visit and 1628 had a greater than 1 year visit. These knees were compared to a reference dataset of 845 primary TKAs from three manufacturers in the same four configurations with currently available products (CURRENT-TKA). Demographics for ATTUNE and CURRENT-TKA were similar and typical for primary TKA. Operative times, clinical outcomes and a series of five patient reported outcomes were compared for ATTUNE vs. CURRENT-TKA. The first 10 ATTUNE subjects for each surgeon were defined as learning curve cases (N=520) and were compared to all later subjects (N=1849) and also with the CURRENT-TKA cases (N=845). Patient reported outcome measures and clinical outcome analyses were adjusted for covariates including patient demographics, pre-op assessment and days post-op.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 101 - 101
1 Feb 2017
Teeter M Van Citters D MacDonald S Howard J Lanting B
Full Access

Background

Fretting corrosion at the junction of the modular head neck interface in total hip arthroplasty is an area of substantial clinical interest. This fretting corrosion has been associated with adverse patient outcomes, including soft tissue damage around the hip joint. A number of implant characteristics have been identified as risk factors. However, much of the literature has been based on metal on metal total hip arthroplasty or subjective scoring of retrieved implants. The purpose of this study was to isolate specific implant variables and assess for material loss in retrieved implants with a metal on polyethylene bearing surface.

Methods

All 28mm and 32 mm femoral heads from a 12/14 mm taper for a single implant design implanted for greater than 2 years were obtained from our institutional implant retrieval laboratory. This included n = 56 of the 28 mm heads (−3: n = 10, +0: n = 24, +4: n = 13, and +8: n = 9), and n = 23 of the 32 mm heads (−3: n = 2, +0: n = 8, +4: n = 1, and +8: n = 6). There were no differences between groups for age, gender, BMI, or implantation time. A coordinate measuring machine was used to acquire axial scans within each head, and the resulting point clouds were analyzed with a custom Matlab program. Maximum linear wear depth (MLWD) was calculated as the maximum difference between the material loss and as-machined surface. Differences in MLWD for head length, head diameter, stem material, and stem offset were determined.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 143 - 143
1 Feb 2017
Matz J Lanting B Howard J Teeter M
Full Access

Introduction

Anterior knee pain following total knee arthroplasty continues to be prevalent and may result from abnormal loading of the patellofemoral joint. The kinematics and biomechanics of the patellofemoral joint are complex, and trochlear design likely plays a principle role in affecting patellofemoral contact. As such, understanding the implications of trochlear design on patellofemoral contact remains important. The goal of the present study was to characterize trochlear wear of retrieved femoral components, which may help elucidate the details regarding patellofemoral kinematics and contact properties in relation to design features.

Materials and Methods

Retrieved femoral components featuring a single design (cobalt-chrome, posterior stabilized, cemented components with fixed bearing design) were included in the study. Components were selected based on similar time-in-vivo, age, and BMI. The trochlea of femoral components was consistently divided into six equal zones. Trochlear wear and surface damage in each zone were assessed using visual inspection under low-magnification light microscopy and light profilometry.


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_3 | Pages 5 - 5
1 Feb 2017
Akindolire J Marsh J Howard J Lanting B Somerville L Vasarhelyi E
Full Access

Background

Total hip arthroplasty (THA) has become one of the most commonly performed elective procedures. Today, there are nearly 50 000 annual hospitalizations for hip replacement surgery in Canada. This number is projected to increase significantly with the aging population. Periprosthetic joint infection (PJI) is the 3rd leading cause of failure following THA and is reported to occur at an incidence of 1–3%. A two-stage revision THA is the current gold standard treatment and this has a tremendous economic impact on the healthcare system. The purpose of this study is to create an accurate cost estimate of two-stage revision THA and, in turn, evaluate the economic burden of PJI as it compares to primary THA in a Canadian healthcare context.

Methods

We conducted a retrospective review of primary THA cases and two-stage revision THA for PJI at our institution. Patients were matched for age and BMI. We recorded all costs associated with each procedure, including: OR time, equipment, length of hospital stay, readmission rates, and any other inpatient resource use. Unit costs were obtained using administrative data from the case costing department at London Health Sciences Centre. Billing fees associated with the procedure were obtained from the Ontario Schedule of Benefits. Descriptive statistics were used to summarize the demographic characteristics of patients, hospital costs and resource use data. Patients with PJI were compared to the matched cohort of primary THA using the t-test (for continuous variables), and the chi-square test (for categorical variables).


Orthopaedic Proceedings
Vol. 99-B, Issue SUPP_4 | Pages 144 - 144
1 Feb 2017
Matz J Lanting B Teeter M Howard J
Full Access

Introduction

Complications related to the patellofemoral joint continue to be a substantial source of patient morbidity, causing anterior knee pain, instability, and dysfunction following total knee arthroplasty. One of the principle factors affecting patellofemoral outcomes may be trochlear design. The optimal design is currently unknown. The purpose of the present study was to study patellofemoral joint contact by analysing areas of wear in retrieved femoral components of three modern designs.

Materials and Methods

Eighteen retrieved femoral components featuring three different designs (constant radius of rotation, multiple radii of rotation, and multiple radii of rotation with built-in external rotation design) were matched on the basis of time-in-vivo, age, BMI and gender. All implants were cobalt chrome, posterior stabilized, cemented components with fixed bearing design with a resurfaced patella. Trochlear wear and surface damage were assessed using visual inspection, low-magnification light microscopy, and light profilometry.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 62 - 62
1 Dec 2016
Matlovich N Lanting B MacDonald S Teeter M Howard J
Full Access

The concept of constitutional varus and controversy regarding placing the total knee arthroplasty (TKA) in a neutral versus physiologic alignment in varus osteoarthritic (OA) patients is an important current discussion. However, the physiologic mechanical alignment of a varus OA knee is unknown and the relative contribution of the femur and tibia to the mechanical axis is unknown. The goal of this study was to determine and analyse the physiologic mechanical axis of medial OA knees.

Plain radiographs of the knee and full-leg standing radiographs of 1558 patients were reviewed for inclusion criteria; 313 patients with a non-arthritic knee and a contralateral varus end-stage OA knee were analysed in the coronal plane. The Hip-Knee-Ankle (HKA), Condylar-Hip (CH)(femoral), Condylar-Plateau (CP) (intra-articular) and Plateau-Ankle (PA)(tibial) angles were measured for both the arthritic and non-arthritic/physiologic knee. The relationship and contribution of all angles was analysed for every 2° degrees of progressive varus: from 4° valgus to 8° varus. The proportion of patients with constitutional varus was also determined for the sample population and correlated with increasing HKA.

The mean CH (femoral) angle was valgus in all groups and decreased with progressive varus alignment (p< 0.0001), ranging from 3.8° ± 1.0° with HKA of 2–4° valgus, to 0.1° ± 1.5° with HKA of 6–8° varus. The mean PA (tibial) angle was varus in all groups and decreased from valgus to progressively varus alignment (p p<0.0001), ranging from 0.78° ± 1.4° with HKA 2–4° valgus, to 5.6° ± 1.9° with HKA 6–8° varus. The CP angle showed no difference between all groups (p=0.3). Forty five percent of males and 22% of females with arthritic HKA in varus alignment were found to have constitutional varus.

Correlation of unilateral arthritic knees to the unaffected, physiologic aligned knee using full-leg radiographs indicates that it may be possible to understand the patient's physiologic, pre-arthritic coronal plane alignment. The mechanical axis of physiologic knees in a unilateral varus OA population demonstrates a variable contribution of the femur (CH) and tibia (PA) from overall valgus to varus alignment. In addition, a significant proportion of the sample population possessed constitutional varus. This may provide important information regarding the placement of physiologic TKA's and direct future research questions.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 1 - 1
1 Dec 2016
Zomar B Muir S Bryant D Vasarhelyi E Howard J Lanting B
Full Access

The purpose of our study was to prospectively examine early functional differences in gait between the direct anterior and direct lateral surgical approaches for total hip arthroplasty over the first three months postoperatively.

Forty participants were prospectively enrolled to either the direct anterior (20 patients) or direct lateral group (20 patients) based on their surgeon's expertise. Outcome measures were collected preoperatively at their preadmission appointment and postoperatively at discharge from the hospital, two weeks, six weeks and three months. We used the GAITRite® system to measure gait velocity, stride length, single-limb support and single-limb support symmetry. We also had participants complete the Timed Up and Go test and a series of questionnaires at each visit: WOMAC, SF-12, Harris Hip Score, and pain VAS.

Our primary outcome, gait velocity, was significantly greater in the direct anterior group at discharge and six weeks postoperatively with adjusted mean differences of 0.12m/s and 0.17m/s respectively. Single-limb support symmetry was also significantly better in the direct anterior group at two weeks, six weeks and three months with adjusted mean differences of 0.10, 0.09 and 0.04 respectively. The direct anterior group also had significantly shorter times to complete the Timed Up and Go test at two and six weeks with adjusted mean differences of −9.02s and −2.64s. There were no differences between the groups at any time point for the WOMAC, SF-12, Harris Hip Score, or pain VAS.

Preliminary results of our expertise-based study have found the direct anterior approach to total hip arthroplasty offers better early functional outcomes than the direct lateral approach.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 55 - 55
1 Dec 2016
Lanting B Thoren J Yuan X McCalden R McAuley J MacDonald S Vasarhelyi E Howard J Naudie D Teeter M
Full Access

Adequate fixation of implant components is an important goal for all arthroplasty procedures. Aseptic loosening is one of the leading causes of revision surgery in total knee arthroplasty. Radiostereometric analysis (RSA) is an imaging technique to measure implant migration, with established migration thresholds for well-fixed, at risk, and unacceptably migrating components. The purpose of the present study was to examine the long-term fixation of a cemented titanium fixed bearing polished tibial baseplate.

Patients enrolled in a previous two-year prospective trial were recalled at ten years. All patients received a cemented, posterior-stabilised total knee replacement of the same design implanted by one of three surgeons. Of the original 35 patients, 16 were available for long-term follow-up, with one patient lost to follow-up, nine patients deceased, and a further nine patients unwilling to return to the clinic. Each patient underwent RSA imaging in a supine position using a conventional RSA protocol. Migration of the tibial component in all planes as well as maximum total point motion (MTPM) was compared between all time points (baseline, six weeks, three months, six months, one year, two years) up to the ten year follow-up visits. Outcome scores including the Knee Society Score (KSS), WOMAC, SF-12, and UCLA Activity Score were recorded.

At ten years, the mean migrations of the tibial component were less than 0.1 mm and 0.1 degree in all planes relative to the post-operative RSA exam. There was no significant difference in tibial component migration between time points. However, MTPM increased significantly over time (p = 0.002), from 0.23 ± 0.18 mm at six weeks to 0.42 ± 0.20 mm at ten years. At one year, 13 patients had an acceptable MTPM level, three patients had an ‘at risk’ level, and no patient had an ‘unacceptable’ level. No patients were revised at ten years. WOMAC and KSS were significantly improved (p < 0.0001) at the latest follow-up compared to pre-operatively, but there was no difference in SF-12. The median UCLA Activity Score at latest follow-up was six (range, two to eight).

The tibial baseplate demonstrated solid fixation at ten years. No patients had an unacceptable MTPM level at one year and no patients were revised at ten years, supporting the use of RSA to predict long-term loosening risk. The low level of tibial baseplate migration found in the present study correlates to the low rate of revision for this implant as reported in individual studies and in joint replacement registries.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 84 - 84
1 Dec 2016
Nyland M Lanting B Somerville L Vasarhelyi E Naudie D McAuley J McCalden R MacDonald S Howard J
Full Access

Infection following total hip arthroplasty (THA) represents a devastating complication and is one of the main causes for revision surgery. This complication may be treated by irrigation and debridement with head and polyethylene exchange (IDHPE) or a two-stage revision (2SR). Previous studies have reported on the eradication success rates but few have reported patient outcome scores. The purpose of this study was to report patient outcome scores for both IDHPE and 2SR and compare these to a non-infected matched cohort. We hypothesised that both cohorts would have worse outcomes than the control group, and that those who failed an initial IDHPE and required a 2SR would have a worse outcome than those treated initially with a 2SR.

A retrospective review identified 137 patients from our institutional arthroplasty database who had an infected primary THA between 1986–2013. We excluded patients with less than one-year follow-up. Mean follow-up was 60 months (12–187 months). A control cohort was identified and matched according to age and Charlton Comorbidity Index (CCI). Harris Hip Scores, Short Form 12 and WOMAC scores were compared between our control group and our infected cohort.

Sixty-eight patients were treated with a 2SR and 69 patients were treated with an IDHPE. There was a 59% success rate in eradicating the infection with an IDHPE. All of the 28 patients who failed an IDHPE later went on to a 2SR. Outcome scores for the 2SR cohort were significantly worse than the non-infected controls (p0.05). There was no difference in outcome scores when comparing our 2SR cohort to our failed IDHPE (p>0.05).

Previous studies have focused on eradication rates. However, it is important to consider patient outcome scores when deciding the best treatment. Infected patients treated with a successful IDHPE had similar outcomes to non-infected patients. Patients that failed IDHPE and went onto 2SR had similar outcomes to those that had a 2SR alone. IDHPE should still be considered in the treatment algorithm of infected THA.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_21 | Pages 59 - 59
1 Dec 2016
Sisko Z Teeter M Lanting B Howard J McCalden R Naudie D MacDonald S Vasarhelyi E
Full Access

Previous retrieval studies demonstrate increased tibial baseplate roughness leads to higher polyethylene backside wear in total knee arthroplasty (TKA). Micromotion between the polyethylene backside and tibial baseplate is affected by the locking mechanism design and can further increase backside wear. The purpose of this study was to examine modern locking mechanisms, in the setting of both roughened and polished tibial baseplates, on backside tibial polyethylene wear.

Five TKA models were selected, all with different tibial baseplate and/or locking mechanism designs. Six retrieval tibial polyethylenes from each TKA model were matched based on time in vivo (TIV), age at TKA revision, BMI, gender, number of times revised, and revision reason. Two observers scored each polyethylene backside according to a visual damage score and individual damage modes. Primary outcomes were mean damage score and individual damage modes. Demographics were compared by one-way ANOVA. Damage scores and modes were analysed by the Kruskal-Wallis test and Dunn's multiple comparisons test.

There were no differences among the groups based on TIV (p=0.962), age (p=0.651), BMI (p=0.951), gender, revision number, or reason for revision. There was a significant difference across groups for mean total damage score (p=0.029). The polished tibial design with a partial peripheral capture locking mechanism and anterior constraint demonstrated a significantly lower score compared to one of the roughened tibial designs with a complete peripheral-rim locking mechanism (13.0 vs. 22.1, p=0.018). Otherwise, mean total damage scores were not significant between groups. As far as modes of wear, there were identifiable differences among the groups based on abrasions (p=0.005). The polished design with a tongue-in-groove locking mechanism demonstrated a significantly higher score compared to both groups with roughened tibial baseplates (5.83 vs. 0.83, p=0.024 and 5.83 vs. 0.92, p=0.033). Only the two designs with roughened tibial baseplates demonstrated dimpling (5.67 and 8.67) which was significant when compared against all other groups (p0.99). No other significant differences were identified when examining burnishing, cold flow, scratching, or pitting. No polyethylene components exhibited embedded debris or delamination.

Total damage scores were similar between all groups except when comparing one of the polished TKA design to one of the roughened designs. The other TKA model with a roughened tibial baseplate had similar damage scores to the polished designs, likely due to its updated locking mechanism. Dimpling wear patterns were specific for roughened tibial baseplates while abrasive wear patterns were identified in the design with a tongue-in-groove locking mechanism. Our study showed even in the setting of a roughened tibial baseplate, modern locking mechanisms decrease backside wear similar to that of other current generation TKA designs.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 59 - 59
1 Nov 2016
Goyal P Yuan X Teeter M McCalden R MacDonald S Vasarhelyi E McAuley J Naudie D Lanting B Howard J
Full Access

Studies that have previously examined the relationship between inclination angle and polyethylene wear have shown increased wear of conventional polyethylene with high inclination angles. To date, there have been no long term in vivo studies examining the correlation between cup position and polyethylene wear with highly crosslinked polyethylene.

An institutional arthroplasty database was used to identify patients who had metal-on-highly crosslinked polyethylene primary total hip arthroplasty (THA) using the same component design with a minimum follow up of 10 years ago. A modified RSA examination setup was utilised, recreating standard anteroposterior (AP) and cross-table lateral exams in a single biplane RSA acquisition. Three dimensional head penetration was measured using the centre index method. The same radiographs were used to measure inclination angle and anteversion. Spearman correlation was used to show an association between the parameters of acetabular position and wear rate.

A total of 43 hips were included for analysis in this study. Average follow-up was 12.3 ± 1.2 years. The average linear wear rate was calculated to be 0.066 ± 0.066 mm/year. Inclination angle was not correlated with polyethylene wear rate (p=0.82). Anteversion was also not correlated with polyethylene wear rate (p=0.11). There was no statistical difference between wear rates of hips within Lewinnek's “safe zone” and those outside this “safe zone” (p=0.11). Males had a higher wear rate of 0.094 ± 0.089 mm/year compared to females with a wear rate of 0.046 ± 0.032 mm/year (p=0.045).

At long term follow up of greater than 10 years, highly cross linked polyethylene has very low wear rates. This excellent tribology is independent of acetabular position, but gender did impact wear rates. Due to the low wear rates, follow-up of even longer term is suggested to examine variables affecting wear.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 87 - 87
1 Nov 2016
Matz J Morden D Teeter M McCalden R MacDonald S Vasarhelyi E McAuley J Naudie D Howard J Lanting B
Full Access

Complications involving the patellofemoral joint are a source of anterior knee pain, instability, and dysfunction following total knee arthroplasty. “Overstuffing” the patello-femoral joint refers to an increase in the thickness of the patellofemoral joint after a total knee replacement compared to the preoperative thickness. While biomechanical studies have indicated that overstuffing the patellofemoral joint may lead to adverse clinical outcomes, limited clinical evidence exists to support this notion. The purpose of this study is to evaluate the effect of changing the thickness of the patellafemoral joint on functional outcomes following total knee arthroplasty.

Our institutional arthroplasty database was used to identify 1347 patients who underwent a primary total knee arthroplasty between 2006 and 2012 with the same component design. Standard preoperative and postoperative anteroposterior, lateral, and skyline radiographs were collected and measured for patello-femoral overstuffing. These measurements included anterior patellar displacement, anterior femoral offset, and anteroposterior femoral size. These measurements were correlated with patient outcome data using WOMAC, KSS scores, and postoperative range of motion. Multiple linear regression analysis was used to assess the association between stuffing and functional outcomes.

A total of 1031 patients who underwent total knee arthroplasty were included. Increased anterior patellar displacement, a measure of patellofemoral joint thickness, was associated with decreased WOMAC scores (p=0.02). Anterior femoral offset (p=0.210) and anteroposterior femoral size (p=0.091) were not significantly associated with patient functional outcomes. Postoperative range of motion (ROM) was not associated with patellofemoral stuffing (p=0.190).

The current study demonstrated that functional outcomes are adversely affected by patellofemoral overstuffing. Based on these results, caution is encouraged against increasing the thickness of the patellofemoral joint, particularly on the patellar side of the joint.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 56 - 56
1 Nov 2016
Nadeau R Howard J Ralley F Somerville L Naudie D
Full Access

Tranexamic acid (TEA), an antifibrinolytic agent, is routinely used for reduction of blood loss in total hip arthroplasty (THA). However, use of intravenous (IV) TEA has been questioned due to safety concerns and a lack of biochemical data in the arthroplasty literature. Tranexamic acid given topically as a periarticular solution is a promising alternative route of administration. The purpose of this study is to identify differences in systemic absorption for intravenous and topical TEA administered during primary THA.

In a blinded randomised controlled trial of patients undergoing primary cementless total hip arthroplasty, 29 participants received a weight-based bolus infusion of intravenous TEA (20 mg/kg) 10 minutes prior to skin incision. Conversely, 15 participants received a 1.5 g bolus dose of TEA administered topically into the periarticular region of the operative hip at the time of arthrotomy closure. A blood sample was drawn one hour post-administration for measurement of serum TEA concentration (µg/mL) by tandem mass spectrometry. In addition to comparing mean concentration levels for both treatment arms, each sample concentration was referenced to a pre-determined TEA concentration threshold of 10 µg/mL, a value known to represent 80% tissue plasminogen activator (tPA) inhibition in vivo.

Those participants receiving topical TEA had four-fold lower TEA levels at one hour postoperatively (mean 12.44 ± 17.59 versus 52.54 ± 23.94 µg/mL, p<0.05).

These results demonstrate significantly lower circulating TEA at one hour after topical administration. Intravenous TEA must travel through the intravascular compartment in order to reach the operative hip. Topical administration of TEA targets bleeding tissues within the surgical field without necessitating parenteral administration. This results in less inhibition of tPA away from the operative site, potentially decreasing the risk of developing a pro-thrombotic state postoperatively. Correlating these results with outcomes from clinical efficacy trials comparing intravenous and topical TEA use in THA will further clarify optimal dosing strategies.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 95 - 95
1 Nov 2016
Howard J Vijayashankar R Sogbein O Ganapathy S Johnston D Bryant D Lanting B Vasarhelyi E MacDonald S
Full Access

Pain immediately following total knee arthroplasty (TKA) is often severe and can inhibit patients' rehabilitation. Recently, adductor canal blocks have been shown to provide adequate analgesia and spare quadriceps muscle strength in the early postoperative period. We devised a single injection motor sparing knee block (MSB) by targeting the adductor canal and lateral femoral cutaneous nerve with a posterior knee infiltration under ultrasound. Our primary objective was to evaluate the analgesia duration of the MSB in comparison to a standard periarticular infiltration (PAI) analgesia using patients' first rescue analgesia as the end point. Secondary outcomes measured were quadriceps muscle strength and length of stay.

We randomised 82 patients scheduled for elective TKA to receive either the preoperative MSB (0.5% ropivacaine, 2.5ug/ml epinephrine, 10mg morphine, and 30mg ketorolac) or intraoperative periarticular infiltration (0.3% ropivacaine, 2.5ug/ml epinephrine, 10mg morphine, and 30mg ketorolac). Duration of analgesia, postoperative quadriceps power, and length of stay were evaluated postoperatively.

Analgesic duration was found to be significantly different between groups. The MSB had a mean duration of 18.06 ± 1.68 hours while the PAI group had a mean duration of 9.25 ± 1.68 hours for a mean difference of 8.8 hours (95% CI 3.98 to 13.62), p<0.01. There were no significant differences between groups in quadriceps muscle strength power at 20 minutes (p=0.91) or 6 hours (p=0.66) after block administration. Length of stay was also not significantly different between the groups (p=0.29).

Motor sparing blocks provide longer analgesia than patients receiving periarticular infiltration while not significantly reducing quadriceps muscle strength or increasing length of hospital stay.


Orthopaedic Proceedings
Vol. 98-B, Issue SUPP_20 | Pages 86 - 86
1 Nov 2016
Burkhart T Perry K Dobbin E Herman B Howard J Lanting B
Full Access

The purpose of this study was to determine the effect of sectioning the relevant soft tissues and a TKA on the medial and lateral knee joint gap.

Twelve intact lower extremity cadaveric specimens (mean (SD) age 76.5 (11.6) years) were tested. A custom designed knee tensioner was developed that allowed the separate application of forces to the medial and lateral components of the knee. The distance between the bottom of the load cell and the top of a compression rod was measured with digital calipers (precision = 0.1mm). Loads of 100N and 200N were then applied to each compartment and the resulting displacement was measured. The two loads were applied to the knee in the following conditions: i) All soft tissues intact; ii) an arthrotomy; iii) ACL sectioned; iv) PCL sectioned; v) release of the mid-coronal tissues; and vi) TKA. Finally, tensions were applied for all conditions from 90° to 0° of knee flexion in 30° increments.

There was a significant effect of soft tissue release on the magnitude of the gap at the 100N load application, such that there was an increase in the when the mid-coronal MCL release was performed compared to the intact (2.2mm) and arthrotomy (1.75mm) conditions. With respect to the 200N load application there was a statistically significant tissue release effect, where differences were detected between the mid-coronal MCL release and intact (3.04mm) and arthrotomy conditions (2.31mm). At the 100N load there was a significance increase in the gap compared to the intact knee. There was also a significant condition by knee angle interaction where the gap was approximately 4mm larger following the TKA compared to the intact condition when the knee was flexed at 90°. Furthermore, there was a statistically significant 4.8mm and 3.8mm difference between 90° and 0° and 60° and 0° of knee flexion respectively, for the TKA condition only. At the 200N load application the gap width increased significantly by 2.5mm following the TKA. Finally, there was a significant condition by knee angle interaction where the change in gap width increased significantly from the intact (7.54mm) to the TKA condition (13.88mm) at 90° of knee flexion. There was a statistically significant difference in the TKA condition between 60° and 0° of knee flexion.

Releasing the soft tissues increases the gap between the tibia and femur, when compared to the intact condition, with significance occurring only following the mid-coronal release. Furthermore, the TKA did not return the knee to its intact state as was evident by the significant difference between the TKA and intact conditions. This suggests that the resulting kinematics may not accurately match those pre-surgery resulting in un-physiological motion patterns and the possibility of early failure and revision.