Advertisement for orthosearch.org.uk
Results 1 - 10 of 10
Results per page:
Bone & Joint Open
Vol. 3, Issue 7 | Pages 573 - 581
1 Jul 2022
Clement ND Afzal I Peacock CJH MacDonald D Macpherson GJ Patton JT Asopa V Sochart DH Kader DF

Aims

The aims of this study were to assess mapping models to predict the three-level version of EuroQoL five-dimension utility index (EQ-5D-3L) from the Oxford Knee Score (OKS) and validate these before and after total knee arthroplasty (TKA).

Methods

A retrospective cohort of 5,857 patients was used to create the prediction models, and a second cohort of 721 patients from a different centre was used to validate the models, all of whom underwent TKA. Patient characteristics, BMI, OKS, and EQ-5D-3L were collected preoperatively and one year postoperatively. Generalized linear regression was used to formulate the prediction models.


The Bone & Joint Journal
Vol. 104-B, Issue 5 | Pages 541 - 548
1 May 2022
Zhang J Ng N Scott CEH Blyth MJG Haddad FS Macpherson GJ Patton JT Clement ND

Aims

This systematic review aims to compare the precision of component positioning, patient-reported outcome measures (PROMs), complications, survivorship, cost-effectiveness, and learning curves of MAKO robotic arm-assisted unicompartmental knee arthroplasty (RAUKA) with manual medial unicompartmental knee arthroplasty (mUKA).

Methods

Searches of PubMed, MEDLINE, and Google Scholar were performed in November 2021 according to the Preferred Reporting Items for Systematic Review and Meta-­Analysis statement. Search terms included “robotic”, “unicompartmental”, “knee”, and “arthroplasty”. Published clinical research articles reporting the learning curves and cost-effectiveness of MAKO RAUKA, and those comparing the component precision, functional outcomes, survivorship, or complications with mUKA, were included for analysis.


Bone & Joint Research
Vol. 10, Issue 1 | Pages 22 - 30
1 Jan 2021
Clement ND Gaston P Bell A Simpson P Macpherson G Hamilton DF Patton JT

Aims

The primary aim of this study was to compare the hip-specific functional outcome of robotic assisted total hip arthroplasty (rTHA) with manual total hip arthroplasty (mTHA) in patients with osteoarthritis (OA). Secondary aims were to compare general health improvement, patient satisfaction, and radiological component position and restoration of leg length between rTHA and mTHA.

Methods

A total of 40 patients undergoing rTHA were propensity score matched to 80 patients undergoing mTHA for OA. Patients were matched for age, sex, and preoperative function. The Oxford Hip Score (OHS), Forgotten Joint Score (FJS), and EuroQol five-dimension questionnaire (EQ-5D) were collected pre- and postoperatively (mean 10 months (SD 2.2) in rTHA group and 12 months (SD 0.3) in mTHA group). In addition, patient satisfaction was collected postoperatively. Component accuracy was assessed using Lewinnek and Callanan safe zones, and restoration of leg length were assessed radiologically.


The Bone & Joint Journal
Vol. 102-B, Issue 4 | Pages 434 - 441
1 Apr 2020
Hamilton DF Burnett R Patton JT MacPherson GJ Simpson AHRW Howie CR Gaston P

Aims

There are comparatively few randomized studies evaluating knee arthroplasty prostheses, and fewer still that report longer-term functional outcomes. The aim of this study was to evaluate mid-term outcomes of an existing implant trial cohort to document changing patient function over time following total knee arthroplasty using longitudinal analytical techniques and to determine whether implant design chosen at time of surgery influenced these outcomes.

Methods

A mid-term follow-up of the remaining 125 patients from a randomized cohort of total knee arthroplasty patients (initially comprising 212 recruited patients), comparing modern (Triathlon) and traditional (Kinemax) prostheses was undertaken. Functional outcomes were assessed with the Oxford Knee Score (OKS), knee range of movement, pain numerical rating scales, lower limb power output, timed functional assessment battery, and satisfaction survey. Data were linked to earlier assessment timepoints, and analyzed by repeated measures analysis of variance (ANOVA) mixed models, incorporating longitudinal change over all assessment timepoints.


Bone & Joint Research
Vol. 9, Issue 1 | Pages 15 - 22
1 Jan 2020
Clement ND Bell A Simpson P Macpherson G Patton JT Hamilton DF

Aims

The primary aim of the study was to compare the knee-specific functional outcome of robotic unicompartmental knee arthroplasty (rUKA) with manual total knee arthroplasty (mTKA) for the management of isolated medial compartment osteoarthritis. Secondary aims were to compare length of hospital stay, general health improvement, and satisfaction between rUKA and mTKA.

Methods

A powered (1:3 ratio) cohort study was performed. A total of 30 patients undergoing rUKA were propensity score matched to 90 patients undergoing mTKA for isolated medial compartment arthritis. Patients were matched for age, sex, body mass index (BMI), and preoperative function. The Oxford Knee Score (OKS) and EuroQol five-dimension questionnaire (EQ-5D) were collected preoperatively and six months postoperatively. The Forgotten Joint Score (FJS) and patient satisfaction were collected six months postoperatively. Length of hospital stay was also recorded.


The Bone & Joint Journal
Vol. 99-B, Issue 2 | Pages 218 - 224
1 Feb 2017
Hamilton DF Loth FL Giesinger JM Giesinger K MacDonald DJ Patton JT Simpson AHRW Howie CR

Aims

To validate the English language Forgotten Joint Score-12 (FJS-12) as a tool to evaluate the outcome of hip and knee arthroplasty in a United Kingdom population.

Patients and Methods

All patients undergoing surgery between January and August 2014 were eligible for inclusion. Prospective data were collected from 205 patients undergoing total hip arthroplasty (THA) and 231 patients undergoing total knee arthroplasty (TKA). Outcomes were assessed with the FJS-12 and the Oxford Hip and Knee Scores (OHS, OKS) pre-operatively, then at six and 12 months post-operatively. Internal consistency, convergent validity, effect size, relative validity and ceiling effects were determined.


Bone & Joint Research
Vol. 4, Issue 8 | Pages 137 - 144
1 Aug 2015
Hamilton DF Giesinger JM Patton JT MacDonald DJ Simpson AHRW Howie CR Giesinger K

Objectives

The Oxford Hip and Knee Scores (OHS, OKS) have been demonstrated to vary according to age and gender, making it difficult to compare results in cohorts with different demographics. The aim of this paper was to calculate reference values for different patient groups and highlight the concept of normative reference data to contextualise an individual’s outcome.

Methods

We accessed prospectively collected OHS and OKS data for patients undergoing lower limb joint arthroplasty at a single orthopaedic teaching hospital during a five-year period. T-scores were calculated based on the OHS and OKS distributions.


The Bone & Joint Journal
Vol. 97-B, Issue 1 | Pages 64 - 70
1 Jan 2015
Hamilton DF Burnett R Patton JT Howie CR Moran M Simpson AHRW Gaston P

Total knee arthroplasty (TKA) is an established and successful procedure. However, the design of prostheses continues to be modified in an attempt to optimise the functional outcome of the patient.

The aim of this study was to determine if patient outcome after TKA was influenced by the design of the prosthesis used.

A total of 212 patients (mean age 69; 43 to 92; 131 female (62%), 81 male (32%)) were enrolled in a single centre double-blind trial and randomised to receive either a Kinemax (group 1) or a Triathlon (group 2) TKA.

Patients were assessed pre-operatively, at six weeks, six months, one year and three years after surgery. The outcome assessments used were the Oxford Knee Score; range of movement; pain numerical rating scales; lower limb power output; timed functional assessment battery and a satisfaction survey. Data were assessed incorporating change over all assessment time points, using repeated measures analysis of variance longitudinal mixed models. Implant group 2 showed a significantly greater range of movement (p = 0.009), greater lower limb power output (p = 0.026) and reduced report of ‘worst daily pain’ (p = 0.003) over the three years of follow-up. Differences in Oxford Knee Score (p = 0.09), report of ‘average daily pain’ (p = 0.57) and timed functional performance tasks (p = 0.23) did not reach statistical significance. Satisfaction with outcome was significantly better in group 2 (p = 0.001).

These results suggest that patient outcome after TKA can be influenced by the prosthesis used.

Cite this article: Bone Joint J 2015;97-B:64–70.


The Bone & Joint Journal
Vol. 96-B, Issue 10 | Pages 1339 - 1343
1 Oct 2014
Hamilton DF Burnett R Patton JT Howie CR Simpson AHRW

Instability is the reason for revision of a primary total knee replacement (TKR) in 20% of patients. To date, the diagnosis of instability has been based on the patient’s symptoms and a subjective clinical assessment. We assessed whether a measured standardised forced leg extension could be used to quantify instability.

A total of 25 patients (11 male/14 female, mean age 70 years; 49 to 85) who were to undergo a revision TKR for instability of a primary implant were assessed with a Nottingham rig pre-operatively and then at six and 26 weeks post-operatively. Output was quantified (in revolutions per minute (rpm)) by accelerating a stationary flywheel. A control group of 183 patients (71 male/112 female, mean age 69 years) who had undergone primary TKR were evaluated for comparison.

Pre-operatively, all 25 patients with instability exhibited a distinctive pattern of reduction in ‘mid-push’ speed. The mean reduction was 55 rpm (sd 33.2). Post-operatively, no patient exhibited this pattern and the reduction in ‘mid-push’ speed was 0 rpm. The change between pre- and post-operative assessment was significant (p < 0.001). No patients in the control group exhibited this pattern at any of the intervals assessed. The between-groups difference was also significant (p < 0.001). This suggests that a quantitative diagnostic test to assess the unstable primary TKR could be developed.

Cite this article: Bone Joint J 2014;96-B:1339–43.


The Bone & Joint Journal
Vol. 96-B, Issue 5 | Pages 622 - 628
1 May 2014
Hamilton DF Lane JV Gaston P Patton JT MacDonald DJ Simpson AHRW Howie CR

Satisfaction with care is important to both patients and to those who pay for it. The Net Promoter Score (NPS), widely used in the service industries, has been introduced into the NHS as the ‘friends and family test’; an overarching measure of patient satisfaction. It assesses the likelihood of the patient recommending the healthcare received to another, and is seen as a discriminator of healthcare performance. We prospectively assessed 6186 individuals undergoing primary lower limb joint replacement at a single university hospital to determine the Net Promoter Score for joint replacements and to evaluate which factors contributed to the response.

Achieving pain relief (odds ratio (OR) 2.13, confidence interval (CI) 1.83 to 2.49), the meeting of pre-operative expectation (OR 2.57, CI 2.24 to 2.97), and the hospital experience (OR 2.33, CI 2.03 to 2.68) are the domains that explain whether a patient would recommend joint replacement services. These three factors, combined with the type of surgery undertaken (OR 2.31, CI 1.68 to 3.17), drove a predictive model that was able to explain 95% of the variation in the patient’s recommendation response. Though intuitively similar, this ‘recommendation’ metric was found to be materially different to satisfaction responses. The difference between THR (NPS 71) and TKR (NPS 49) suggests that no overarching score for a department should be used without an adjustment for case mix. However, the Net Promoter Score does measure a further important dimension to our existing metrics: the patient experience of healthcare delivery.

Cite this article: Bone Joint J 2014;96-B:622–8.