Reconstruction of soft tissues and preservation of the extensor mechanism integrity provide a major challenge following resection of the proximal tibia tumours. We propose a novel surgical technique for neopatellar ligament reconstruction using hamstring tendon in proximal tibia tumour cases. This study details the surgical technique, early clinical and radiological outcomes, and the potential long-term benefits of this innovative reconstructive approach following proximal tibia megaprosthesis implantation. This study included 15 patients with proximal tibia tumours treated at orthopaedic oncology unit in Gujarat Cancer and Research Institue (GCRI), Ahmedabad, India. Surgical procedures included resecting the proximal tibia tumour, implanting a megaprosthesis, and using hamstring tendons to reconstruct the extensor mechanism by the neopatellar ligament. Autologous hamstring tendons (gracilis and semitendinosus) harvested from the ipsilateral leg were used and these tendons were braided together with a nonabsorbable suture and threaded through the remaining patellar tendon. The braided tendons were then secured to the holes in the tibial tuberosity of the proximal tibia megaprosthesis implant XLO (Ortho Life Systems, India) using nonabsorbable fibre wire sutures FiberWire (Arthrex, USA). The tension in the tendons was optimized and the sutures were tightened with the knee in full extension and the implant with neopatellar ligament were covered by medial gastrocnemius muscle flap. The mean follow-up period was 19 months (13 to 24), the mean age of the study group was 24.6 years (14 to 44), and it included 11 males and four females.Aims
Methods
Paediatric pelvic ring fractures are rare but severe injuries, presenting significant treatment challenges. This study aimed to analyze patient characteristics and explore trends in incidence, treatment methods, and mortality associated with these injuries. This multicentre, retrospective cohort study analyzed paediatric patients (aged ≤ 18 years) with pelvic ring fractures treated between 2001 and 2021 at two level 1 trauma centres. Data on patient demographics, injury characteristics, treatment approaches, and outcomes were collected, and visual trend analysis was conducted to identify patterns.Aims
Methods
Nonunion occurs when a fracture fails to heal permanently, often necessitating surgical intervention to stimulate the bone healing response. Current animal models of long-bone nonunion do not adequately replicate human pathological conditions. This study was intended as a preliminary investigation of a novel rat nonunion model using a two-stage surgical intervention, and to evaluate the efficacy of a selective prostaglandin E2 receptor 4 agonist (AKDS001) as a novel nonunion therapeutic agent compared with existing treatments. Initially, Sprague-Dawley rats underwent intramedullary Kirschner wire (K-wire) fixation of a femoral fracture with the interposition of a 2 mm-thick silicon disc. After three weeks, the silicon disc was removed, and the intramedullary K-wire was replaced with plate fixation while maintaining the 2 mm defect. Contrary to the control group (1) that received no treatment, the following therapeutic interventions were performed at injury sites after freshening: (2) freshening group: no grafting; (3) iliac bone (IB) group: IB grafting; (4) AKDS group: AKDS001-loaded microspheres (MS) combined with IB (0.75 mg/ml); and (5) bone morphogenetic protein (BMP) group: grafting of a BMP-2-loaded collagen sponge (10 μg; 0.10 mg/ml). After six weeks, micro-CT (μCT) and histological analysis was performed.Aims
Methods
To evaluate patient-reported outcomes three months after treatment of metacarpal and phalangeal fractures or dislocations, and to identify factors that are associated with worse patient-reported outcomes. This cross-sectional, multicentre snapshot study included all adult patients with metacarpal and phalangeal fractures or dislocations during a three-month period between August and October 2020. The primary outcome was the Michigan Hand Outcomes Questionnaire (MHQ) three months after injury. The MHQ scores were compared to normative MHQ scores of 90 points of the affected hand of patients who sustained unilateral trauma derived from a previous study. Subgroup analyses were performed for the most common injury types. Multivariable linear regression was used to study associations between patient characteristics and worse MHQ scores.Aims
Methods
Aims. Osseous invasion exhibited in
To develop a multidisciplinary health research agenda (HRA) utilizing expertise from various disciplines to identify and prioritize evidence uncertainties in orthopaedics, thereby reducing research waste. We employed a novel, structured framework to develop a HRA. We started by systematically collecting all evidence uncertainties from stakeholders with an interest in orthopaedic care, categorizing them into 13 sub-themes defined by the Dutch Orthopaedic Association (NOV). Subsequently, a modified two-phased Delphi study (two rounds per phase), adhering to the Conducting and REporting DElphi Studies (CREDES) guideline, was conducted. In Phase 1, board members assessed the collected evidence uncertainties on a three-point Likert scale to confirm knowledge gaps. In Phase 2, diverse stakeholders, including orthopaedic surgeons, rated the confirmed knowledge gaps on a seven-point Likert scale. Panel members rated one self-selected sub-theme and two randomly assigned sub-themes. The results from Phase 2 were ranked based on the overall average score for each uncertainty. Finally, a focus group discussion with patient associations’ representatives identified their top-ranked uncertainty from a predefined consensus process, leading to the final HRA. An advisory board, the Federation of Medical Specialists, and the NOV research coordinator oversaw the process.Aims
Methods
The conversion of previous hip fracture surgery to total hip arthroplasty (CTHA) can be surgically challenging with unpredictable outcomes; reported complication rates vary significantly. This study aimed to establish the medium-term survival and outcomes of CTHA performed following a previous hip fracture surgery. All CTHAs performed at our tertiary orthopaedic institution between January 2008 and January 2020 following previous ipsilateral hip fracture surgery were included. Patients were followed up clinically using Oxford Hip Scores (OHS), and radiologically until death or revision surgery. Postoperative complications, radiological implant failure, and indications for revision surgery were reviewed.Aims
Methods
Revision hip arthroplasty for femoral stem loosening remains challenging due to significant bone loss and deformities requiring specialized revision stems. The aim of this study was to evaluate the clinical and radiological outcomes, and survival, of a consecutive series of femoral revisions performed using a primary cementless stem with tapered geometry and rectangular cross-section at medium-term follow-up. We retrospectively evaluated 113 patients (115 hips) with intraoperative Paprosky type I (n = 86) or II (n = 29) defects, who underwent femoral revision with Alloclassic Zweymüller SL stem for one-stage aseptic revision or two-stage septic revision from January 2011 to December 2020. The mean follow-up was 77.9 months (SD 33.8). Nine patients were lost to follow-up (deceased or not available), leaving 104 patients (106 hips) for the clinical and radiological analysis. Clinical assessment was performed with Harris Hip Score (HHS) and visual analogue scale (VAS) before surgery and at final follow-up.Aims
Methods
This study aimed to investigate whether the use of CT-based navigation enhances: 1) the accuracy of cup placement; and 2) the achievement rate of required range of motion (ROM). Additionally, we investigated the impact of using a large femoral head and dual-mobility liner on the achievement rates. This retrospective study analyzed 60 manual and 51 CT-based navigated primary total hip arthroplasties performed at a single facility. Postoperative CT scans and CT-based simulation software were employed to measure the cup orientation and to simulate the ROM. We compared the absolute errors for radiological inclination (RI) and radiological anteversion (RA) between the two groups. We also examined whether the simulated ROM met the required ROM criteria, defined as flexion > 110°, internal rotation > 30°, extension > 30°, and external rotation > 30°. Furthermore, we performed simulations with 36 mm femoral head and dual-mobility liner.Aims
Methods
Sagittal lumbar pelvic alignment alters with posterior pelvic tilt (PT) following total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH). The individual value of pelvic sagittal inclination (PSI) following rebalancing of lumbar-pelvic alignment is unknown. In different populations, PT regresses in a linear relationship with pelvic incidence (PI). PSI and PT have a direct relationship to each other via a fixed individual angle ∠γ. This study aimed to investigate whether the new PI created by acetabular component positioning during THA also has a linear regression relationship with PT/PSI when lumbar-pelvic alignment rebalances postoperatively in patients with Crowe type III/IV DDH. Using SPINEPARA software, we measured the pelvic sagittal parameters including PI, PT, and PSI in 61 patients with Crowe III/IV DDH. Both PSI and PT represent the pelvic tilt state, and the difference between their values is ∠γ (PT = PSI + ∠γ). The regression equation between PI and PT at one year after THA was established. By substituting ∠γ, the relationship between PI and PSI was also established. The Bland-Altman method was used to evaluate the consistency between the PSI calculated by the linear regression equation (ePSI) and the actual PSI (aPSI) measured one year postoperatively.Aims
Methods
Over time, the locking mechanism of Modular Universal Tumour and Revision System (MUTARS) knee arthroplasties changed from polyethylene (PE) to polyether-ether-ketone Optima (PEEK) and metal-on-metal (MoM) in an attempt to reduce the risk of mechanical failure. In this study, we aimed to assess the cumulative incidence of locking mechanism revision for symptomatic instability by type of material, and assess potential associated risk factors. The MUTARS Orthopaedic Registry Europe was used for a retrospective review of 316 patients (54% male (n = 170), median age 44 years (IQR 23 to 61)) who underwent a MUTARS knee arthroplasty for oncological indications between December 1995 and January 2023. The minimum follow-up was 12 months, and the median follow-up was 7.9 years (IQR 3.3 to 13.0). A competing risk model was used to estimate the cumulative incidence of first locking mechanism revision with death and revision for any other reason as competing events. Possible risk factors were assessed employing a univariate cause-specific hazards regression model.Aims
Methods
The Birmingham Orthopaedic Oncology Meeting (BOOM), held in January 2024, convened 309 delegates from 53 countries to discuss and refine 21 consensus statements on the optimal management of chondrosarcoma. With representation from Europe (43%; n = 133), North America (17%; n = 53), South America (16%; n = 49), Asia (13%; n = 40), Australasia (5%; n = 16), the Middle East (4%; n = 12), and Africa (2%; n = 6), the combined experience of treating bone sarcomas among attendees totalled approximately 30,000 cases annually, equivalent to 66 years of experience in the UK alone. The meeting’s process began with the formation of a local organizing committee, regional leads, and a scientific committee comprising representatives from 150 specialist units across 47 countries. Supported by major orthopaedic oncology organizations, the meeting used a modified Delphi process to develop consensus statements through online questionnaires, thematic groupings, narrative reviews, and anonymous pre-meeting polling.Aims
Methods
Hip fractures commonly occur in older patients, with high levels of frailty and comorbidity. Many of these patients have limited mobility before their fracture, and even after surgery, their mobility may remain limited. It is therefore not surprising that they are at a high risk of developing pressure sores, particularly on their heels, and a variety of devices and interventions have been proposed to reduce this risk. Foam or air mattresses, designed to reduce contact pressure on the patient’s whole body, are now routinely used in many healthcare systems. However, there is wide variation in their design. We developed the WHiTE 14;PRESSURE 3 trial to address the lack of evidence in this area. This is a three-arm multicentre randomized trial including health economic evaluation and recruiting patients from NHS hospitals in the UK. The trial compares standard strategies for the prevention of pressure sores with standard care plus a constant low-pressure device and with standard care plus a heel off-loading device. This annotation describes the development of this trial. Cite this article:
Aims. The aim of the present study was to analyze the oncological and neurological outcome of patients undergoing interdisciplinary treatment for primary malignant bone and
Aims. The aim of this study was to report long-term clinical outcomes of a modern convertible metal-backed glenoid (MBG) in total shoulder arthroplasty (TSA). Methods. After a minimum of 15 years, a previously studied cohort of 35 patients who received a modern convertible MBG during the period 1996 to 2005 was contacted for clinical and radiological follow-up. At last follow-up, patients were evaluated radiologically and clinically according to the Constant Score, Simple Shoulder Test, and visual analogue scale for pain. Complications and revisions were recorded, and survival analysis was performed. Results. At the last follow-up, 20 patients were contacted. Of these, 15 patients had experienced at least one complication, and ten underwent revision surgery. The mean time to revision was 13.8 years (7 to 20). Cuff failure was the most common complication. Conversion to reverse shoulder arthroplasty, while maintaining the baseplate, was possible in five cases, with good results. In patients in whom the baseplate was removed, revision was performed significantly later (18.4 vs 11.1 years; p = 0.016). The general revision-free survival was 73% (95% CI 49.5 to 87.3) at 15 years and 38% (95% CI 11.8% to 64.3%) at 20 years, while MBG revision-free survival was 96.0% (95% CI 74.8% to 99.4%) at 15 years and 54% (95% CI 16.2% to 80.8%) at 20 years. Clinical scores showed a negative trend over time, although not statistically significant. Radiologically, polyethylene wear was observed in all cases and was complete in 12 out of 19 cases, and five glenoids were ‘at risk’ for loosening. Conclusion. At long-term follow-up, convertible MBG-TSA revealed a high rate of complications and revision surgery, mainly due to
Periacetabular osteotomy (PAO) is well established for acetabular reorientation and has shown successful improvement in patient-reported outcome measures (PROMs). Nevertheless, studies focusing on postoperative outcomes related to patient individual factors are still underrepresented. Therefore, this study aimed to analyze the functional outcome and activity level in relation to patient sex with a minimum follow-up of two years after PAO for mild to severe hip dysplasia. A single-centre study was conducted, enrolling patients undergoing PAO and completing a preoperative and postoperative radiological and clinical outcome assessment. The PROMs were assessed using the modified Harris Hip Score (mHHS), the Hip disability and Osteoarthritis Outcome Score (HOOS) with the subscales for pain, sport, activities of daily living (ADL), and quality of life (QoL), and the University of California, Los Angeles (UCLA) activity score. Kendall’s tau were calculated for correlation analyses.Aims
Methods
The aim of this study was to evaluate the radiological outcome of patients with large bone defects in the femur and tibia who were treated according to the guidelines of the diamond concept in our department (Centre for Orthopedics, Trauma Surgery, and Paraplegiology). The following retrospective, descriptive analysis consists of patients treated in our department between January 2010 and December 2021. In total, 628 patients were registered, of whom 108 presented with a large-sized defect (≥ 5 cm). A total of 70 patients met the inclusion criteria. The primary endpoint was radiological consolidation of nonunions after one and two years via a modified Lane-Sandhu Score, including only radiological parameters.Aims
Methods
Around the world, the emergence of robotic technology has improved surgical precision and accuracy in total knee arthroplasty (TKA). This territory-wide study compares the results of various robotic TKA (R-TKA) systems with those of conventional TKA (C-TKA) and computer-navigated TKA (N-TKA). This is a retrospective study utilizing territory-wide data from the Clinical Data Analysis and Reporting System (CDARS). All patients who underwent primary TKA in all 47 public hospitals in Hong Kong between January 2021 and December 2023 were analyzed. Primary outcomes were the percentage use of various robotic and navigation platforms. Secondary outcomes were: 1) mean length of stay (LOS); 2) 30-day emergency department (ED) attendance rate; 3) 90-day ED attendance rate; 4) 90-day reoperation rate; 5) 90-day mortality rate; and 6) surgical time.Aims
Methods
The primary aims of this study were to determine the time to sonographic correction of decentred hips during treatment with Pavlik harness for developmental dysplasia of the hip (DDH) and investigate potential risk factors for a delayed response to treatment. This was a retrospective cohort study of infants with decentred hips who underwent a comprehensive management protocol with Pavlik harness between 2012 and 2016. Ultrasound assessments were performed at standardized intervals and time to correction from centring of the femoral head was quantified. Hips with < 40% femoral head coverage (FHC) were considered decentred, and hips with > 50% FHC and α angles > 60° were considered corrected. Survival analyses using log-rank tests and Cox regression were performed to investigate potential risk factors for delayed time to correction.Aims
Methods