Abdelaal A Munigangaiah S Trivedi J Davidson N

Aims. Magnetically controlled growing rods (MCGR) have been gaining popularity in the management of early-onset scoliosis (EOS) over the past decade. We present our experience with the first 44 MCGR consecutive cases treated at our institution. Methods. This is a retrospective review of consecutive cases of MCGR performed in our institution between 2012 and 2018. This cohort consisted of 44 children (25 females and 19 males), with a mean age of 7.9 years (3.7 to 13.6). There were 41 primary cases and three revisions from other rod systems. The majority (38 children) had dual rods. The group represents a mixed aetiology including idiopathic (20), neuromuscular (13), syndromic (9), and congenital (2). The mean follow-up was 4.1 years, with a minimum of two years. Nine children graduated to definitive fusion. We evaluated radiological parameters of deformity correction (Cobb angle), and spinal growth (T1-T12 and T1-S1 heights), as well as complications during the course of treatment. Results. The mean Cobb angles pre-operatively, postoperatively, and at last follow-up were 70° (53 to 103), 35° (15 to 71) and 39° (15 to 65) respectively (p < 0.001). Further, there was a mean of 14° (-6 to 27) of additional Cobb angle correction upon graduation from MCGR to definitive fusion. Both T1-T12 and T1-S1 showed significant increase in heights of 27 mm and 45 mm respectively at last follow-up (p < 0.001). Ten children (23%) developed 18 complications requiring 21 unplanned operations. Independent risk factors for developing a complication were single rod constructs and previous revision surgery. Conclusion. MCGR has the benefit of avoiding multiple surgeries, and is an effective tool in treatment of early-onset scoliosis. It also maintains the flexibility of the spine, allowing further correction at the time of definitive fusion. Cite this article: Bone Joint Open 2020;1-7:405–414


Abstract

MAGnetic Expansion Control (MAGEC) rods are used in the surgical treatment of children with early onset scoliosis. The magnetically controlled lengthening mechanism enables rod distractions without the need for repeated invasive surgery. The CE certification of these devices was suspended in March 2021 due, primarily, to performance evidence gaps in the documents provided by the manufacturer to regulators and notified bodies. MAGEC rods are therefore not permitted for use in countries requiring CE marking. This was a survey of 18 MAGEC rod surgeons in the UK about their perception of the impact of the CE suspension on the clinical management of their patients. Unsurprisingly, virtually all perceived a negative impact, reflecting the complexity of this patient group. Reassuringly, these surgeons are highly experienced in alternative treatment methods.

Cite this article: Bone Jt Open 2022;3(2):155–157.