Aims. The aim of this study was to evaluate the survival of a collarless, straight, hydroxyapatite-coated femoral stem in
Aims. The aim of this study was to evaluate the reliability and validity of a patient-specific algorithm which we developed for predicting changes in sagittal pelvic tilt after
Aims. Despite higher rates of revision after
Aims. Sagittal lumbar pelvic alignment alters with posterior pelvic tilt (PT) following
Aims. The aim of this study was to determine whether
The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA). A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size.Aims
Methods
Aims. Although periarticular injection plays an important role in multimodal pain management following
Aims. The most frequent indication for revision surgery in
Aims. The aim of this study was to identify the effect of the manufacturing characteristics of polyethylene acetabular liners on the survival of cementless and hybrid
Aims. Modular dual mobility (DM) prostheses in which a cobalt-chromium liner is inserted into a titanium acetabular shell (vs a monoblock acetabular component) have the advantage of allowing supplementary screw fixation, but the potential for corrosion between the liner and acetabulum has raised concerns. While DM prostheses have shown improved stability in patients deemed ‘high-risk’ for dislocation undergoing
Aims. To determine ten-year failure rates following 36 mm metal-on-metal
(MoM) Pinnacle
In this review, we discuss the evidence for patients returning to sport after hip arthroplasty. This includes the choices regarding level of sporting activity and revision or complications, the type of implant, fixation and techniques of implantation, and how these choices relate to health economics. It is apparent that despite its success over six decades, hip arthroplasty has now evolved to accommodate and support ever-increasing patient demands and may therefore face new challenges. Cite this article:
Aims. The aim of this study was to investigate the association between fracture displacement and survivorship of the native hip joint without conversion to a
Aims. Periprosthetic proximal femoral fractures (PFFs) are a major complication after
Aims. Isolated acetabular liner exchange with a highly crosslinked polyethylene (HXLPE) component is an option to address polyethylene wear and osteolysis following
Aims. The aim of this study was to estimate the 90-day periprosthetic joint infection (PJI) rates following total knee arthroplasty (TKA) and
Aims. The aim of our study was to investigate the effect of asymmetric crosslinked polyethylene liner use on the risk of revision of cementless and hybrid
Aims. We compared the clinical outcomes of curved intertrochanteric varus osteotomy (CVO) with bone impaction grafting (BIG) with CVO alone for the treatment of osteonecrosis of the femoral head (ONFH). Methods. This retrospective comparative study included 81 patients with ONFH; 37 patients (40 hips) underwent CVO with BIG (BIG group) and 44 patients (47 hips) underwent CVO alone (CVO group). Patients in the BIG group were followed-up for a mean of 12.2 years (10.0 to 16.5). Patients in the CVO group were followed-up for a mean of 14.5 years (10.0 to 21.0). Assessment parameters included the Harris Hip Score (HHS), Oxford Hip Score (OHS), Japanese Orthopaedic Association Hip-Disease Evaluation Questionnaire (JHEQ), complication rates, and survival rates, with conversion to
Worldwide controversy exists on the optimal treatment of stable dysplastic hips. The most common treatment options are abduction brace treatment and active surveillance. The primary aim of this study was to assess the effect of active surveillance in stable hip dysplasia, by investigating the percentage of Graf IIb stable dysplastic hips that recover spontaneously without abduction brace treatment. The second aim was to identify prognostic factors for spontaneous recovery of stable dysplastic hips. A single-centre, prospective cohort study was conducted at the Máxima Medical Center between 1 March 2019 and 1 March 2023. Infants aged three to 4.5 months at the first outpatient clinic visit, diagnosed with Graf IIb hip dysplasia, and treated with active surveillance were included. Spontaneous recovery was defined as infants who had a normalized hip on ultrasound (α-angle ≥ 60°) after six weeks of active surveillance without receiving abduction brace treatment. Baseline infant characteristics and ultrasound measurements were used as potential predictor variables for spontaneous recovery in logistic regression analyses.Aims
Methods
Aims. Various surgical techniques have been described for