The primary outcome was investigating differences in wear, as measured by femoral head penetration, between cross-linked vitamin E-diffused polyethylene (vE-PE) and cross-linked polyethylene (XLPE) acetabular component liners and between 32 and 36 mm head sizes at the ten-year follow-up. Secondary outcomes included acetabular component migration and patient-reported outcome measures (PROMs) such as the EuroQol five-dimension questionnaire, 36-Item Short-Form Health Survey, Harris Hip Score, and University of California, Los Angeles Activity Scale (UCLA). A single-blinded, multi-arm, 2 × 2 factorial randomized controlled trial was undertaken. Patients were recruited between May 2009 and April 2011. Radiostereometric analyses (RSAs) were performed from baseline to ten years. Of the 220 eligible patients, 116 underwent randomization, and 82 remained at the ten-year follow-up. Eligible patients were randomized into one of four interventions: vE-PE acetabular liner with either 32 or 36 mm femoral head, and XLPE acetabular liner with either 32 or 36 mm femoral head. Parameters were otherwise identical except for acetabular liner material and femoral head size.Aims
Methods
Many surgeons choose to perform total knee arthroplasty (TKA) surgery with the aid of a tourniquet. A tourniquet is a device that fits around the leg and restricts blood flow to the limb. There is a need to understand whether tourniquets are safe, and if they benefit, or harm, patients. The aim of this study was to determine the benefits and harms of tourniquet use in TKA surgery. We searched MEDLINE, EMBASE, Cochrane Central Register of Controlled trials, and trial registries up to 26 March 2020. We included randomized controlled trials (RCTs), comparing TKA with a tourniquet versus without a tourniquet. Outcomes included: pain, function, serious adverse events (SAEs), blood loss, implant stability, duration of surgery, and length of hospital stay.Aims
Methods
The aims of this study were to validate the outcome of total elbow arthroplasty (TEA) in patients with rheumatoid arthritis (RA), and to identify factors that affect the outcome. We searched PubMed, MEDLINE, Cochrane Reviews, and Embase from between January 2003 and March 2019. The primary aim was to determine the implant failure rate, the mode of failure, and risk factors predisposing to failure. A secondary aim was to identify the overall complication rate, associated risk factors, and clinical performance. A meta-regression analysis was completed to identify the association between each parameter with the outcome.Aims
Methods
The aim of this study was to identify the effect of the manufacturing characteristics of polyethylene acetabular liners on the survival of cementless and hybrid total hip arthroplasty (THA). Prospective cohort study using linked National Joint Registry (NJR) and manufacturer data. The primary endpoint was revision for aseptic loosening. Cox proportional hazard regression was the primary analytical approach. Manufacturing variables included resin type, crosslinking radiation dose, terminal sterilization method, terminal sterilization radiation dose, stabilization treatment, total radiation dose, packaging, and face asymmetry. Total radiation dose was further divided into G1 (no radiation), G2 (> 0 Mrad to < 5 Mrad), G3 (≥ 5 Mrad to < 10 Mrad), and G4 (≥ 10 Mrad).Aims
Methods
The number of arthroplasties being performed
increases each year. Patients undergoing an arthroplasty are at
risk of venous thromboembolism (VTE) and appropriate prophylaxis
has been recommended. However, the optimal protocol and the best
agent to minimise VTE under these circumstances are not known. Although
many agents may be used, there is a difference in their efficacy
and the risk of bleeding. Thus, the selection of a particular agent relies
on the balance between the desire to minimise VTE and the attempt
to reduce the risk of bleeding, with its undesirable, and occasionally
fatal, consequences. Acetylsalicylic acid (aspirin) is an agent for VTE prophylaxis
following arthroplasty. Many studies have shown its efficacy in
minimising VTE under these circumstances. It is inexpensive and
well-tolerated, and its use does not require routine blood tests.
It is also a ‘milder’ agent and unlikely to result in haematoma
formation, which may increase both the risk of infection and the
need for further surgery. Aspirin is also unlikely to result in persistent
wound drainage, which has been shown to be associated with the use
of agents such as low-molecular-weight heparin (LMWH) and other
more aggressive agents. The main objective of this review was to summarise the current
evidence relating to the efficacy of aspirin as a VTE prophylaxis
following arthroplasty, and to address some of the common questions
about its use. There is convincing evidence that, taking all factors into account,
aspirin is an effective, inexpensive, and safe form of VTE following
arthroplasty in patients without a major risk factor for VTE, such
as previous VTE. Cite this article:
Controversy about the use of an anatomical total shoulder arthroplasty
(aTSA) in young arthritic patients relates to which is the ideal
form of fixation for the glenoid component: cemented or cementless.
This study aimed to evaluate implant survival of aTSA when used
in patients aged < 60 years with primary glenohumeral osteoarthritis (OA),
and to compare the survival of cemented all-polyethylene and cementless
metal-backed glenoid components. A total of 69 consecutive aTSAs were performed in 67 patients
aged < 60 years with primary glenohumeral OA. Their mean age
at the time of surgery was 54 years (35 to 60). Of these aTSAs,
46 were undertaken using a cemented polyethylene component and 23
were undertaken using a cementless metal-backed component. The age, gender,
preoperative function, mobility, premorbid glenoid erosion, and
length of follow-up were comparable in the two groups. The patients
were reviewed clinically and radiographically at a mean of 10.3
years (5 to 12, Aims
Materials and Methods
Total knee arthroplasty (TKA) is a major orthopaedic
intervention. The length of a patient's stay has been progressively
reduced with the introduction of enhanced recovery protocols: day-case
surgery has become the ultimate challenge. This narrative review shows the potential limitations of day-case
TKA. These constraints may be social, linked to patient’s comorbidities,
or due to surgery-related adverse events (e.g. pain, post-operative
nausea and vomiting, etc.). Using patient stratification, tailored surgical techniques and
multimodal opioid-sparing analgesia, day-case TKA might be achievable
in a limited group of patients. The younger, male patient without
comorbidities and with an excellent social network around him might
be a candidate. Demographic changes, effective recovery programmes and less invasive
surgical techniques such as unicondylar knee arthroplasty, may increase
the size of the group of potential day-case patients. The cost reduction achieved by day-case TKA needs to be balanced
against any increase in morbidity and mortality and the cost of
advanced follow-up at a distance with new technology. These factors
need to be evaluated before adopting this ultimate ‘fast-track’
approach. Cite this article:
There is conflicting evidence about the benefit
of using corticosteroid in periarticular injections for pain relief
after total knee arthroplasty (TKA). We carried out a double-blinded,
randomised controlled trial to assess the efficacy of using corticosteroid
in a periarticular injection to control pain after TKA. A total of 77 patients, 67 women and ten men, with a mean age
of 74 years (47 to 88) who were about to undergo unilateral TKA
were randomly assigned to have a periarticular injection with or
without corticosteroid. The primary outcome was post-operative pain
at rest during the first 24 hours after surgery, measured every
two hours using a visual analogue pain scale score. The cumulative
pain score was quantified using the area under the curve. The corticosteroid group had a significantly lower cumulative
pain score than the no-corticosteroid group during the first 24
hours after surgery (mean area under the curve 139, 0 to 560, and
264, 0 to 1460; p = 0.024). The rate of complications, including
surgical site infection, was not significantly different between
the two groups up to one year post-operatively. The addition of corticosteroid to the periarticular injection
significantly decreased early post-operative pain. Further studies
are needed to confirm the safety of corticosteroid in periarticular
injection.
Cite this article: