Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

Children's Orthopaedics

ACCEPTABILITY OF MANIPULATION OF PAEDIATRIC FOREARM FRACTURES IN THE EMERGENCY DEPARTMENT

The British Society for Children' s Orthopaedic Surgery (BSCOS) and the Swedish Paediatric Orthopaedic Society (SBOF), Combined Meeting, March 2017



Abstract

Purpose

This study evaluated the acceptability of performing manipulations with intranasal diamorphine and inhaled Entonox to parents of children presenting to our Emergency Department.

Method

65 fractures were manipulated in the Emergency Department in a 4-month timespan. Parents were invited to complete a questionnaire to indicate their experience with the procedure. Fracture position post-reduction was calculated as well as conversion rate to surgery. 32 patients who were admitted and had their forearm fractures managed in theatre were also asked to complete the questionnaire as a comparison group.

Results

Overall response rate was 82% . 100% of parents of children who had a manipulation in the emergency department would recommend the treatment to parents of children with similar injuries.

Relative risk of perceived distress to parents was 2.42 (0.8–7.2) with manipulation in the emergency department compared to theatre management. Relative risk of distress to the child was 1.45 (0.7–3.3) with manipulation in the emergency department compared to theatre management. This was not statistically significant.

Mean (S.D.) fracture displacement was 29.2 (13.0)° pre reduction and 5.8 (5.9)° post reduction. Mean (S.D.) length of stay was 5.5 (3.2) hours from time of injury to discharge for patients receiving manipulation in the Emergency Department and 27.9 (14.3) hours for patients receiving procedures in theatre (p< 0.001).

Overall, parents and children were satisfied about manipulations in the Emergency Department. Operative re-intervention rate was 2% when protocol violations were excluded. Reduction was as effective as previous reports and within acceptable treatment limits.

Conclusion

Manipulation of paediatric forearm fracture is an effective and acceptable technique when performed with a diamorphine and Entonox protocol.