Advertisement for orthosearch.org.uk
Orthopaedic Proceedings Logo

Receive monthly Table of Contents alerts from Orthopaedic Proceedings

Comprehensive article alerts can be set up and managed through your account settings

View my account settings

Visit Orthopaedic Proceedings at:

Loading...

Loading...

Full Access

A1035. METAPHYSEAL ENGAGING SHORT STEM FREMORAL IMPLANTS: A TWO-YEAR FOLLOW-UP



Abstract

Despite the clinical success of uncemented femoral stems of various types, current issues continue to require repeated examination:

  1. proximal-distal mismatch

  2. optimization of load transfer and preservation of femoral bone and

  3. facilitation of MIS (minimally-invasive surgery) exposures, particularly an anterior approach.

A previous study demonstrated that a custom-made (based on CT-scan) short metaphyseal engaging femoral stem design provided stable fixation and reliable bony ingrowth at four-year follow-up. The purpose of this study is to present the minimum two-year clinical and radiographic results obtained with an off-the-shelf metaphyseal filling stem.

An uncemented, metaphyseal engaging femoral stem was inserted in 194 consecutive hips in 181 patients, whose average age was 70 years (range 32–95) and BMI of 28 (range 19–63). The implant, which averaged 94 millimeters in length (range 91–105), was made of titanium alloy with a hydroxyapatite coating on a titanium plasma-spray in the third of the stem.

The average Harris hip score (HHS) was 52 (range 10–80) preoperatively and 91 (range 70–100) postoperatively and no patients experienced thigh pain. Preoperative WOMAC scores averaged 48, compared to a postoperative average of 4. There were no fractures or other complications related to the prosthesis, no radiographic evidence of subsidence, and all stems were radiographically stable on most recent radiographs. The typical pattern of bony ingrowth was that of bone bridging and endosteal condensation at the proximal portion of the stem.

This study demonstrated that the use of an off-the-shelf short femoral stem designed to fit and fill the metaphysis provides reliable clinical and radiographic results at a minimum two-year (average 31 months) follow-up. Short stems may be particularly helpful to surgeons performing total hip arthroplasty using a MIS anterior approach.

Correspondence should be addressed to Diane Przepiorski at ISTA, PO Box 6564, Auburn, CA 95604, USA. Phone: +1 916-454-9884; Fax: +1 916-454-9882; E-mail: ista@pacbell.net