Abstract
Introduction: Limb lengthening with external fixators has been associated with many complications including pin tract infections, damage to neurovascular structures, joint stiffness, delayed consolidation, and pain. These can lead to a detrimental functional outcome and psychological upset with a consequent negative impact on patients’ quality of life. The Intramedullary Skeletal Kinetic Distractor (ISKD) is a fully implantable device that may offer a better functional and psychological outcome. The aim of this study therefore was to evaluate the functional and psychological outcome in a series of patients undergoing femoral lengthening with the ISKD.
Methods: Twenty patients underwent intramedullary lengthening via ISKD. Eighteen of these had lost femoral bone length secondary to trauma, and two were affected by congenital limb shortening (one had both femora lengthened at different time intervals). Patients completed Toronto Extremity Salvation Score (TESS) (to evaluate subjective physical disability), and Short Form 36 (SF36) questionnaires pre and post-operatively.
Results: Patients’ post operative TESS scores demonstrated a significant improvement in patient perception of their physical disability. SF36 responses after surgery improved in several areas including physical functioning, role limitation due to emotional problems, social functioning, mental health, pain experienced and change in health; the greatest improvements seen in role limitation due to emotional problem, social functioning, mental health, pain, and change in health.
Discussion: These results indicate that limb lengthening with the ISKD improves patients’ overall quality of life decreasing post operative pain, improving their social functioning and mental health, overall ISKD lengthening improves how the patients perceive their health and physical disability.
Correspondence should be addressed to BLRS c/o BOA, at the Royal College of Surgeons, 35–43 Lincoln’s Inn Fields, London, WC2A 3PE, England.