Abstract
Clinical experience has shown the needs for high flexion. The aim of this study was to evaluate the clinical and radiological results of a fixed bearing high flexion posterior stabilized (PS) total knee arthroplasty (TKA).
Between July 2001 and December 2005, 422 TKAs in 288 patients were performed with high flexion PS prosthesis and 378 knees of 258 patients had been followed up for 2 to 6.5 years (mean: 3 years 11 months). We evaluated range of motion (ROM), Knee rating system of the Hospital for Special Surgery (HSS) and Knee Society (KS) score, and radiological results.
The mean flexion improved from 110.1 degrees to 126.7 degrees at the latest follow-up. 333 knees (88 %) showed more than 120 degrees of flexion, 105 knees (28 %) more than 140 degrees of flexion. The mean KS clinical score improved from 39 to 93 points (p< 0.01) and KS function score, from 40 to 85.4 points (p< 0.01). The mean HSS score improved from 41.2 to 86.3 points (p< 0.01). In 28 knees, radiolucent line of 1–2 mm in width was observed at zone 1 without symptoms. Aseptic loosening in 4 knees, Mid-flexion instability in 2 knees, superficial infection in 3 knees and deep infection in 3 knees were observed.
Total knee arthroplasty with high flexion PS prosthesis showed good ROM and satisfactory early clinical results. Complication rate was similar to those of other series. Close observation and serial radiological evaluation are needed for long term results.
Correspondence should be addressed to ISTA Secretariat, PO Box 6564, Auburn, CA 95604, USA. Tel: 1-916-454-9884, Fax: 1-916-454-9882, Email: ista@pacbell.net